Decommissioning Ageing Infrastructure: Abandoning or Re-Routing Hydrocarbon Pipelines. Dave Vernon - Director of Isolation Services
|
|
- Sandra George
- 5 years ago
- Views:
Transcription
1 Decommissioning Ageing Infrastructure: Abandoning or Re-Routing Hydrocarbon Pipelines Dave Vernon - Director of Isolation Services
2 Overview Abandonment and Decommissioning Pipeline Disconnection Pipeline Rerouting Pipeline Abandonment Riser Isolation Flow Line Plugging The 130 metre high Brent Delta topside heading for Hartlepool, UK Photo: Shell / Allseas STATS GROUP Slide: 2
3 Typical Mature Field Overview Decommissioned In Decommissioning Image: TAQA Bratani STATS GROUP Slide: 3
4 Hub Platform Configuration Several pipelines in the image are scheduled for disconnection in the near future Image: TAQA Bratani STATS GROUP Slide: 4
5 Why Double Block and Bleed Isolation Equipment? Pipeline Diver Safety Positive Pressure Diver Safety Negative Pressure Environmental Protection Reduced Diver Time Reduced Flushing and Purging Operations Downstream production unaffected (upstream too with pre-installed bypass) STATS GROUP Slide: 5
6 Equipment for Isolation and Abandonment Abandonment and Decommissioning Remote Tecno Plug Tethered Tecno Plug BISEP Pipeline Connector (Sleeve or Adaptor) Pipe End Plugs STATS GROUP Slide: 6
7 Secondary Seal Integrity Test: Leak-Off Test 1) Pressure locked in the annulus 2) Pressure behind (inboard) vented Secondary seal tested with full differential pressure in correct direction. STATS GROUP Slide: 7
8 Primary Seal Integrity Test: Build-Up Test 1) Pipeline pressure in front (outboard) 2) Annulus pressure vented and locked in Primary seal tested with full differential pressure in correct direction. STATS GROUP Slide: 8
9 Dual Redundancy Activation: Fail-Safe Self-energisation (Self-Locking) feature maintains a safe isolation while differential pressure (above the verified minimum pressure) exists across the tool. The isolation plug has two separate activation mechanisms Dual Redundant Activation. The isolation tool is activated and held in place by internal hydraulics AND energised and mechanically locked by the differential pressure. Both separate activation mechanisms need to be removed to unset the plug. NOTE: Permanent abandonment plugs include an additional mechanical lock which removes long term reliance on the hydraulics STATS GROUP Slide: 9
10 Passive Unset: Fail-Safe Passive Unset feature ensures the Tecno Plug is always recoverable upon job completion. Fail-safe in unlikely event of communication system issues. Passive Unset happens when tail pressure is equalised with the head pressure. This de-latches the locked in hydraulic pressure; open circuited to return. Equalising the pressure across the plug removes self energisation force. Once equalised the plug will then passively unset without any active control input. NOTES: Isolation cannot be unset until the breaking containment operation is completed and the pressure behind the plug is raised to pipeline isolated pressure. If the pressure is equalised, the plug will become unset unless it is actively commanded not to unset. The passive unset is done in a safe and controlled manner only when the pressure is equalised across the tool. STATS GROUP Slide: 10
11 Case Study: Pipeline Disconnect & Abandonment Abandonment and Decommissioning 8 Triple BISEP Pipeline Bypass STATS GROUP Slide: 11
12 Case Study: Pipeline Disconnect & Abandonment STATS GROUP Slide: 12
13 Case Study: Pipeline Disconnect & Abandonment Disconnect and Abandonment Final Pipeline Configuration STATS GROUP Slide: 13
14 Case Study: Subsea Platform Bypass STATS GROUP Slide: 14
15 Animation: Subsea Platform Bypass Animation 1 STATS GROUP Slide: 15
16 Thank You For Your Attention Questions? for more information visit STATS GROUP Slide: 16
17 Copyright & Disclaimer Copyright Copyright of all published material including photographs, drawings and images in this document remains vested in STATS (UK) Ltd and third party contributors as appropriate. Accordingly, neither the whole nor any part of this document shall be reproduced in any form nor used in any manner without express prior permission and applicable acknowledgements. No trademark, copyright or other notice shall be altered or removed from any reproduction. Disclaimer Although STATS Group believes that the Presentation and the references therein are based upon reasonable assumptions, it can give no assurance that the actual results will be as set out in the Presentation. STATS Group is making no representation or warranty, expressed or implied, as to the accuracy, reliability or completeness of the Presentation or the data referenced therein, and neither STATS (UK) Ltd nor any of its directors, officers or employees will have any liability to you or any other persons resulting from your use. STATS Group consists of many legally independent entities, constituting their own separate identities. STATS Group is used as the common brand or trade mark for most of these entities. In this presentation we may sometimes use STATS, we or us when we refer to STATS Group companies in general or where no useful purpose is served by identifying any particular STATS Group company. STATS GROUP Slide: 17
Trine Risøy, Bergen,
part of Aker The Installation of Subsea Structures without Offshore Crane Vessel Trine Risøy, Bergen, 04.06.2008 2008 Aker Solutions AKER MARINE CONTRACTORS (AMC) 35 years experience worldwide: Subsea
More informationEMERGENCY PIPELINE REPAIR SYSTEMS DEVELOPED TO FACILITATE PIPELINE REPAIR OF UNPIGGABLE DEFECTS. By: Dale Millward, STATS Group, United Kingdom
EMERGENCY PIPELINE REPAIR SYSTEMS DEVELOPED TO FACILITATE PIPELINE REPAIR OF UNPIGGABLE DEFECTS By: Dale Millward, STATS Group, United Kingdom Introduction The term Double Block and Bleed is mostly used
More informationEmergency Pipeline Repair Isolation System
Emergency Pipeline Repair Isolation System Isolation technology developed to facilitate pipeline repair of unpiggable defects Author: Dale Millward BEng (Hons) Director, EPRS & Subsea Services Introduction
More informationSubsea Safety Systems
Subsea Safety Systems The ELSA-HP has been developed to service the high pressure horizontal tree completion and intervention market. With systems designed and qualified up to 15,000 psi, 250 degf and
More informationSuccess Paths: A Risk Informed Approach to Oil & Gas Well Control
API Winter E&P Standards Conference, Austin January 18, 2017 Success Paths: A Risk Informed Approach to Oil & Gas Well Control Dr. Dan Fraser Director, Strategic Alliances for Global Energy Solutions,
More informationValve Replacement: Using Non-Intrusive Isolation Technology to Minimize Production Downtime
CASE STUDY CS15-02 >> Valve Replacement: Using Non-Intrusive Isolation Technology to Minimize Production Downtime What s Inside:» Explore Double Block & Monitor» Increase Operational Safety» Achieve Double
More informationBarrier Philosophy for Wells on Gas lift and Ways of Reducing HSE Risks. Alan Brodie Feb 2011 For more info visit
Barrier Philosophy for Wells on Gas lift and Ways of Reducing HSE Risks Alan Brodie Feb 2011 For more info visit www.ptc.as Introduction Gas Lifted Well Integrity Management Incremental HSE risks Case
More informationTAM Single SeT inflatable
TAM Single SeT inflatable ReTRievAble PAckeRS Sets with pressure only Releases with straight pull or rotate Ideal for horizontal applications Sets in casing or open hole Runs on tubing, coiled tubing,
More informationSDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual
SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual 8 Executive Drive P.O. Box 2105 Toms River, NJ 08754 (732) 244-0010 (800) 337-3762 fax (732) 244-8140 www.permapure.com info@permapure.com
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification
More informationDesign DSA Steam-Atomized Desuperheater
Instruction Manual DSA Desuperheater Design DSA Steam-Atomized Desuperheater Contents Introduction............................... 1 Scope of Manual......................... 1 Description..............................
More informationSHELL FLAGS INSPECTION CASE STUDY
SHELL FLAGS INSPECTION CASE STUDY J. Nonemaker, Solution Engineer, ROSEN T. Steinvoorte, Business Development, ROSEN R. Subramanian, Pipelines & Subsea Technical Support Engineer, Shell U.K. Limited Introduction
More informationCATALOGUE // The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification. Fort Vale Engineering Ltd. 2009
CATALOGUE // 20 19 18 16 17 The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification 15 14 Fort Vale Engineering Ltd. 2009 THIS PAGE IS INTENTIONALLY BLANK HYDROGEN PEROXIDE EQUIPMENT
More informationTalk 2 Tree & Wellhead Valve Testing Leak Rate Acceptance. Talk 3 DHSV Control Line hydrocarbon Ingress measurement & acceptability
Talisman energy COIN Virtual Meeting # 17 26 th January 2011 Darren Bewick Graeme Douglas Martin Forbes David McGuckien Matt Morrison Martin Mosley Talisman Energy UK Ltd (TLMUK), Aberdeen 1 Presentations
More informationInstallation, Operation & Maintenance Manual
Original Instructions Installation, Operation & Maintenance Manual Sentry VREL Control Valve Pressure Conditioning S-SW-IOM-00277-15 1-17 Table of Contents Safety Information... 3 General Safety Precautions...
More informationFRAGMENTATION INSTRUCTION & OPERATION HANDBOOK
FRAGMENTATION INSTRUCTION & OPERATION HANDBOOK Doc. Jordair FRAGMENTATION-MANUAL WARNING! HIGH PRESSURE UNITS Under no circumstances should the fill stations be operated with the safety relief valves removed
More informationWeatherford Inverse Gas Lift System (IGLS)
36 th Gas-Lift Workshop Stavanger, Norway February 4 8, 2013 Weatherford Inverse Gas Lift System (IGLS) Jerry Sutton Senior Applications Engineer 2013 Gas-Lift Workshop Contents Why is IGLS needed? What
More informationWelker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct
More informationTECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.
Foam 302 a 1. DESCRIPTION (Refer to Figure 1 on page 302 e.) The Viking Low-Flow Foam/Water Proportioning System is a UL Listed and FM Approved system, for use with 3M and Viking brand foam concentrate.
More informationInstallation Operation Maintenance
682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description
More informationFisher DSA Steam-Atomized Desuperheater
Instruction Manual DSA Desuperheater Fisher DSA Steam-Atomized Desuperheater Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Installation... 2 Operating Instructions...
More information92831 TEL: (714) FAX:
Document N0. 1800-03 Copyright 2010 Terra Universal Inc. All rights reserved. Revised Sept. 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:
More informationGlobal Gas Lift Optimization Using WellTracer Surveys
36 th Gas-Lift Workshop Stavanger, Norway February 4 8, 2013 Global Gas Lift Optimization Using WellTracer Surveys Tony Hord, Mike Johnson ExxonMobil Production Company 2013 Gas-Lift Workshop 1 WellTracer
More informationFisher DVI Desuperheater Venturi Inline
Instruction Manual DVI Desuperheater Fisher DVI Desuperheater Venturi Inline Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Installation... 3 Operating Instructions...
More informationabc INSTALLATION, OPERATING & MAINTENANCE MANUAL FOR HYDRAULIC EXTRACTOR
abc INSTALLATION, OPERATING & MAINTENANCE MANUAL FOR HYDRAULIC EXTRACTOR This Jiskoot Product is designed to provide outstanding service if correctly installed, used and maintained recognising the effects
More informationHill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide
Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide Secondary Coolant System Start-Up Procedures June 2006 Produced by the Hill PHOENIX Learning Center DISCLAIMER This
More informationWeatherford Inverse Gas Lift System (IGLS)
Gas Well Deliquification Workshop Sheraton Hotel, February 17 20, 2013 Weatherford Inverse Gas Lift System (IGLS) Norman Strachan Product Manager (IGLS) Renaissance Systems Contents Why is IGLS needed?
More informationSubsea Tree Valve Actuator Permanent Reinstatement Systems. Dr Lev Roberts-Haritonov General Manager, Subsea Engineering
Subsea Tree Valve Actuator Permanent Reinstatement Systems Dr Lev Roberts-Haritonov General Manager, Subsea Engineering Introduction Problem Overview Temporary Fix Neptune Permanent Tree Valve Actuator
More informationStatus Date Prepared Reviewed Endorsed Approved
Discipline Engineering Standard NSW Category Signalling Title Reference Number SMP 08 (RIC Standard: SC 00 52 00 08 SI) Document Control Status Date Prepared Reviewed Endorsed Approved Issue 1 Revision
More informationSafe hydraulics for hydroforming presses. more finished product to be created from less raw material.
profile Drive & Control Safe hydraulics for hydroforming presses Safety Standard Guidelines for Hydraulic Presses In several western regions, safety standards exist that describe how to achieve safe control
More informationTroubleshooting Gas-lift Wells Using Dual Shot Acoustic Technique
2018 Artificial Lift Strategies for Unconventional Wells Workshop Cox Convention Center, Oklahoma City, OK February 4 7, 2018 Troubleshooting Gas-lift Wells Using Dual Shot Acoustic Technique Shea Province
More informationLockout / Tag out Program
Lockout / Tag out Program Presented by DOSHTI www.doshti.com You will learn Purpose of Lockout- Tag out Requirements for LOTO Types of Hazardous Energy Procedures for LOTO The OSHA Standard for the Control
More informationVeriforce TG CCT 661OP. Training Guide
Training Guide Directions: This training guide is to be used by a Veriforce Authorized Evaluator/Trainer and Trainee during on-thejob training (OJT) or prior to an evaluation as a resource. (S) Indicates
More informationINSTALLATION GUIDE Gas Rangetops
INSTALLATION GUIDE Gas Rangetops Contents Wolf Gas Rangetops........................... 3 Safety Instructions............................ 4 Gas Rangetop Specifications.................... 5 Gas Rangetop
More informationCOSASCO 6000 PSI DOUBLE ISOLATION SERVICE VALVE MAINTENANCE
COSASCO 6000 PSI DOUBLE ISOLATION SERVICE VALVE MAINTENANCE 11841 Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com Page: 2 of 28 Revision History
More informationRiskTopics. Lockout/Tagout October 2017
RiskTopics Lockout/Tagout October 2017 This Risktopic is designed to outline guidelines for lockout/tagout and provide assistance in developing a management program to reduce the risk of injury from unintended
More informationRECOMMENDATION FOR INTERCHANGEABLE FLANGED DRILLING CHOKE DIMENSIONS
RECOMMENDATION FOR INTERCHANGEABLE FLANGED DRILLING CHOKE DIMENSIONS TECHNICAL REPORT TR0601 AWHEM publications may be used by anyone desiring to do so. Every effort has been made by the Association to
More informationCOSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE
COSASCO 6000 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE 11841 Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com Page: 2 of 26 Revision
More informationGE Oil & Gas. Mooney * Flowgrid * Slam Shut Regulator. Delivering accuracy, performance and protection
GE Oil & Gas Mooney * Flowgrid * Slam Shut Regulator Delivering accuracy, performance and protection Industries Gas transmission Gas distribution Midstream gas Gas processing Applications Gas pipelines
More informationCovered Task 614OP Training Guide Purging Pipeline Facilities with Air or Inert Gas
Directions This training guide is to be used by a Subject matter expert (SME) authorized Evaluator/Trainer and Trainee during on-thejob training (OJT) or prior to an evaluation as a resource. (S) Indicates
More informationHPHT Annular Casing Packer. Obex Annular Casing Packer
HPHT Annular Casing Packer Obex Annular Casing Packer Industry Challenge Casing packer to support second stage cement Reduce hydrostatic pressure on formation Get cement to surface Annular gas migration
More informationHIPPS Development Project
Hydraulic HIPPS HIPPS Development Project This presentation describes the Energy Equipment Corporation Hydraulic HIPPS control development project, and gives: Brief background information about Energy
More informationInstallation, Operation & Maintenance Manual
Original Instructions Installation, Operation & Maintenance Manual Sentry Cobra FV Sampler Low Emission Samplers S-MS-IOM-00543-0 08-18 Table of Contents Safety Information... 3 General Safety Precautions...
More informationCase History. North Sea Platform Wellhead Isolation Tubing Hanger Body Seals Locking Device 20-3/4 x 13-3/8 Mandrel Neck Seal
Case History North Sea Platform Wellhead Isolation Tubing Hanger Body Seals Locking Device 20-3/4 x 13-3/8 Mandrel Neck Seal History / Introduction: Failed test issues as reported in 2001(SBMS-II, S Seal)
More information256 Pneumatic Pressure Indicator
256 Pneumatic Pressure Indicator 51425699 Copyright 2002 Slope Indicator Company. All Rights Reserved. This equipment should be installed, maintained, and operated by technically qualified personnel. Any
More informationIsolation Lockout and Tagging
PURPOSE To define the minimum system requirements for isolation of plant and equipment from hazardous substances, mechanical, electrical or other energy sources to protect all workers from personal injury
More informationWhat Geologists Need to Know about Drilling
INTEGRITY RESPECT ACCOUNTABILITY SAFETY RESILIENCE SUCCESS What Geologists Need to Know about Drilling Wayne Pengelly 27 March 2018 newhopegroup.com.au Introduction Teamwork Only need one Crew to achieve
More informationModel 106 DPI "Micro-switch" Installation and Operating Instructions
Mid-West Instrument Model 106 DPI "Micro-switch" Installation and Operating Instructions BULLETIN NO. IM116DPImicro/09A Replaces --- INSPECTION Before installation carefully check the Model Number on each
More informationLockout Tagout Policy
Office of Environmental Health & Safety www.moreheadstate.edu/ehs 606-783-2584 Lockout Tagout Policy PURPOSE To establish procedures for the de-energization and isolation of energy sources or the lockout
More informationTECHNICAL DATA. than the water inlet pressure to the concentrate
Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler
More informationLOCKOUT SYSTEM AND POLICIES
LOCKOUT SYSTEM AND POLICIES Lockout System Purpose Employees health and safety takes top priority. Isolating hazardous energy to prevent sudden and unexpected energisation of machines, equipment, and processes
More informationManual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation
FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator For inflating aircraft tires and all types of other vehicle tires and air operated devices Manual The Fresh Aero Group Where Imagination Meets
More informationMULTI-DIAMETER, BI-DIRECTIONAL PIGGING FOR PIPELINE PRE-COMMISSIONING
MULTI-DIAMETER, BI-DIRECTIONAL PIGGING FOR PIPELINE PRE-COMMISSIONING By: Magne Andreas Vik, StatoilHydro; Alf Åge Kristiansen, StatoilHydro Simon Sykes, FTL Seals Technology; Steve Hutcheson, Pipeline
More informationSpirax Compact FREME Flash Recovery Energy Management Equipment
IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.
More informationPPC2+ BG0002. Operation and Maintenance Manual (Use with PPC2+ Operation and Maintenance Manual) 2001 DH Instruments, Inc.
PPC2+ BG0002 Operation and Maintenance Manual (Use with PPC2+ Operation and Maintenance Manual) High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be
More informationAbandonment Program for Paramount Fort Liard F 36
Abandonment Program for Paramount Fort Liard F 36 Well Name: Paramount et al Liard F 36 Area: 60 0 10 N, 123 0 15 W Location: Latitude: 60 0 05 27 Longitude: 123 0 22 00 UWI: 300F366010123150 WID: 1841
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions
More informationWet pipe low flow foam/water system
December 6, 2010 Foam 14a 1. The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with Viking supplied foam concentrates. This system consists of a standard
More informationAlkylphosphines. Storage and Handling Recommendations
Alkylphosphines Storage and Handling Recommendations 2 The Phosphine Specialties Group has been producing phosphine and phosphine derivatives on a large scale for a number of years and the handling procedures
More informationIWCF Equipment Sample Questions (Surface Stack)
IWCF Equipment Sample Questions (Surface Stack) 1. During a well control operation 4000 psi was shut in below the middle pipe rams. Ram type BOP data: Model: Cameron U type Rated Working Pressure: 15000
More informationOctober 10, 2018 Annual Seminar New England Pipeline Safety Representatives Meredith, New Hampshire Randy Knepper Director of Safety, NHPUC
SOFT OFFs Safety and Convenience Considerations October 10, 2018 Annual Seminar New England Pipeline Safety Representatives Meredith, New Hampshire Randy Knepper Director of Safety, NHPUC Some years ago,
More informationINSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:
PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)
More informationHYDROGEN PEROXIDE Railcar Unloading by Self-Priming Pump Technical Data Sheet
HYDROGEN PEROXIDE RAILCAR UNLOADING BY SELF-PRIMING PUMP INTRODUCTION All equipment used for storage and handling of hydrogen peroxide must be dedicated exclusively to hydrogen peroxide service and must
More informationURC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports
URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT 2013 Universal Remote Control, Inc. The information in this Owner s Manual is copyright protected.
More informationLockout/Tagout Training Overview. Safety Fest 2013
Lockout/Tagout Training Overview Safety Fest 2013 Purpose of Lockout/Tagout The standard covers the servicing and maintenance of machine and equipment in which the unexpected energization or start up of
More informationSPE The paper gives a brief description and the experience gained with WRIPS applied to water injection wells. The main
SPE 102831 Online Water-Injection Optimization and Prevention of Reservoir Damage Bjørn Øyvind Bringedal, Svein Arne Morud, Nicolas Alexander Hall, ABB; Gary Huseman, Shell Copyright 2006, Society of Petroleum
More informationAPI 682 Mechanical Seals. Swagelok Eastern Australia & New Zealand
API 682 Mechanical Seals Swagelok Eastern Australia & New Zealand API 682 Mechanical Seals Overview Previous projects completed o Plan 53A o Plan 72 / 76 o Plan 74 API 682 Mechanical Seals Overview What
More informationCompact Triple Cabinet Outlet Station Model B Installation and Operating Instructions
PORTER Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 Compact Triple Cabinet Outlet Station Model
More informationCompact Triple Cabinet Outlet Station Model Installation and Operating Instructions
Compact Triple Cabinet Outlet Station Model 6258-1 Installation and Operating Instructions The Porter Compact Triple Outlet Station (6258-1) provides a quick, safe, and reliable method of connection to
More informationInstallation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07
Installation, Operation and Maintenance Manual TSV Temperature Shut-off Valve SPD 13.1.2 Rev. 6 10/07 SENTRY EQUIPMENT CORP PO Box 127 Oconomowoc, WI 53066 USA Phone: 262.567.7256 Fax: 262.567.4523 Email:
More information12V Mini Air Compressor
INSTRUCTIONS FOR 12V Mini Air Compressor Stock No.80999 Part No.DA12/250B IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION This
More informationOverview EUSDSG3.12. Install gas meters and regulators (2.5 to 16.0m3/hr)
Overview This national occupational standard is for gas engineerswho are required to install and exchange meters and regulators (2.5 to 16.0m3/hr) on low pressure and medium pressure gas systems. This
More informationTAQA North Ltd. Well Blowout W4M June 8, 2009
TAQA North Ltd. Well Blowout 10-10-28-29W4M June 8, 2009 ERCB Investigation Report January 11, 2010 Report prepared by Brian Temple (Incident Investigator), Rondine Cabot (Field Surveillance), Mark R.
More informationCOSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE
COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com
More informationUNIVERSAL TUBE HOLDER SYSTEM
UNIVERSAL TUBE for Constant Low Flow & Constant-Pressure (Multi-Flow) Operation INSTRUCTION MANUAL 16333 Bay Vista Dr. Clearwater, Florida 33760 (800) 451-9444 (727) 530-3602 (727) 539-0550 [FAX] Revision
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves Instruction Manual PLEASE NOTE: This instruction manual provides information and instructions
More informationTESCOM 50-4X Series Safety, Installation & Start-Up Procedures
Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this
More informationEMERGING AUTOMOTIVE, CRUDE OIL, AND CHEMICALS SUPPLY CHAINS IN THE US SOUTHEAST
SEPTEMBER 2015 EMERGING AUTOMOTIVE, CRUDE OIL, AND CHEMICALS SUPPLY CHAINS IN THE US SOUTHEAST Presentation to the Southeast Association of Rail Shippers 2015 Fall Conference, Orlando, Florida Christopher
More informationFPD175 Compact orifice carrier assembly
ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION FPD175 Compact orifice carrier assembly The smart solution for remote applications. Measurement made easy Installation, commissioning and operating / maintenance
More informationVLI Visible Level Interface Operation & Maintenance Manual
VLI Visible Level Interface Operation & Maintenance Manual All rights reserved. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted
More informationCONTROL OF HAZARDOUS ENERGY (LOCKOUT/TAG OUT PROGRAM) Washington State University Tri-Cities (all departments)
CONTROL OF HAZARDOUS ENERGY (LOCKOUT/TAG OUT PROGRAM) Washington State University Tri-Cities (all departments) PURPOSE This program establishes the general and specific requirements for the control of
More informationrepair & earn a free bike?
Want to learn to repair & earn a free bike? SIGN UP FOR A FUN, FREE, AFTER-SCHOOL CLASS! W HE N: 4-6 pm* Wed & Thurs * Except on these ACT days [9/20, 10/4, 10/18] when class is from 2:45-5 pm. W H ER
More informationCaptain Wellhead & Tree
North Sea Platform 13-3/8 Casing Hanger Annulus Pack-off Product & Procedure Overview Ref: AB374RM 04-07-2007 The following is based on limited information available at the time of this evaluation History:
More informationFisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves
Instruction Manual D103319X012 Lever-Lock Handlever Actuator Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves Contents Introduction................................. 1 Scope of Manual.........................
More informationThe Practical Guide To Long Range Hunting Cartridges
The Long Range Hunting Series The Practical Guide To Long Range Hunting Cartridges (2nd Edition) Nathan Foster Copyright Information Copyright 2017 - Nathan Foster, New Zealand - All rights reserved. All
More informationSAFETY FEATURES OF PORTABLE CRYOGENIC LIQUID CONTAINERS FOR INDUSTRIAL AND MEDICAL GASES
SAFETY FEATURES OF PORTABLE CRYOGENIC LIQUID CONTAINERS FOR INDUSTRIAL AND MEDICAL GASES AIGA 016/04 Asia Industrial Gases Association 298 Tiong Bahru Road, #20-01 Central Plaza, Singapore 168730 Tel :
More informationGAS SUPPLY DESIGN GUIDE
GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14
More informationGas Lift Valve Testing
36 th Gas-Lift Workshop Stavanger, Norway February 4 8, 2013 Gas Lift Valve Testing Angel Wileman, Research Engineer Southwest Research Institute, Fluid Dynamics Feb. 4 8, 2013 2013 Gas-Lift Workshop 1
More informationVenting Atmospheric and Low-pressure Storage Tanks API STANDARD 2000 SEVENTH EDITION, MARCH 2014
Venting Atmospheric and Low-pressure Storage Tanks API STANDARD 2000 SEVENTH EDITION, MARCH 2014 Special Notes API publications necessarily address problems of a general nature. With respect to particular
More informationDeepwater Horizon Incident Internal Investigation
Not all Information has been verified or corroborated. Subject to review based on additional information or analysis. Deepwater Horizon Incident Internal Investigation 1 Areas of Discussion Investigation
More informationField Development & Construction
Field Development & Construction Michael Cowie Technical Director Ecosse Subsea Systems Ltd Ambient Lifting: A Real Alternative to Heavy Lift Vessels 4 th February 2016, AECC, Michael Cowie Presentation
More informationQUESTIONS AND ANSWERS ON AUDIT PARTNER ROTATION REQUIREMENTS IN MALAYSIA
QUESTIONS AND ANSWERS ON AUDIT PARTNER ROTATION REQUIREMENTS IN MALAYSIA Audit partner rotation requirements will change for periods beginning on or after 15 December 2018. The changes will affect Key
More informationCommissioning of Subsea Hydraulic Systems
Commissioning of Subsea Hydraulic Systems DISCLAIMER This Discussion Paper does not purport to contain all of the information that may be required to evaluate the Business and any intending investor and
More informationA record Quarter and Year for the Group
14 January 2019 2018 and FY18 Trading Update Steve Ingham Kelvin Stagg Chief Executive Officer Chief Financial Officer A record Quarter and Year for the Group LSE: PAGE.L Website: http://www.page.com/investors
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFT LINE CUTTER SL55 PRODUCT CODE No. 980504 INSTRUCTIONS FOR INSTALLATION,
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationSECTION P4 SEPARATION SYSTEMS
SEPARATION SYSTEMS The platform has a Separation System which consists of a Test Separator (MBD-100). The gas, oil and water discharges to the Departing Bulk Oil Pipeline (KAH-1200). Rev: 1 Date: 7/31/12
More informationCOSASCO 3600 PSI SINGLE SERVICE VALVE MAINTENANCE
COSASCO 3600 PSI SINGLE SERVICE VALVE MAINTENANCE 11841 Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 Revision History Record www.cosasco.com Page: 2 of
More informationM03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC
Before you start: Check the manifold box contents against the list below. Check the contents Flow gauges 1. Bar assembly with manual return valves 2. 2 x Auto air vent & drain hose attachments Optional
More informationContinuous Injection of Hydrate Inhibitor in Gas Lift Gas to Mitigate Downtime Due to Downhole Annular Plugging
32 nd Gas-Lift Workshop The Hague, The Netherlands February 2-6, 2009 Continuous Injection of Hydrate Inhibitor in Gas Lift Gas to Mitigate Downtime Due to Downhole Annular Plugging John R. Cliver and
More information