CentriFlow Meter Integrated Air Entrainment System

Similar documents
Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Pressure Dump Valve Service Kit for Series 2300 Units

GM Series Dual-Block Multi-Function Gas Control Valves

Electropneumatic Transducer (I/P) Installation, Operation and

HP10168 & HP10169 KITS HP10152 / HP10154 / HP10156

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Model 130M Pneumatic Controller

Pressure Dump Valve Service Kit for Series 3000 Units

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Related Products: Auto Drain Valve. Model/Specifications. Model

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Section 3- Repair and Calibration Procedures

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Air Intake Snorkel Kit

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

GILMONT ACCUCAL FLOWMETERS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

3/8" Dr. Air Butterfly Impact Wrench

Yoke Block Instruction Manual

Installation, Operation, and Maintenance Manual

INSTRUCTION MANUAL & PARTS

INSTALLATION & MAINTENANCE INSTRUCTIONS

Air Operated Hydraulic Pumping Systems to 50,000 psi

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Adjustment & Calibration Instructions

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Poppetted Coaxial Drop Tube Assembly for use with Auto Limiter II. Installation Instructions

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

Model VR6 System. Installation, Operation & Maintenance

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

TWO POST RAM PACKAGE 55 GALLON

Baby Booster Manual. KISS Rebreather, LLC. MSL Jetsam/ Baby Booster Manual R.2

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

CS150 CAP STAPLER OWNER S MANUAL

Installation Instructions

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

RG1200 Service and Repair Manual

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

CSA Sample Draw Aspirator Adapter Operator s Manual

1 DRIVE INDUSTRIAL IMPACT WRENCH

Steel Spring Driven Reel Instruction Manual

SIMPLAIR PIPING TOOL. JXT Company

TECHNICAL DATA. Trimpac 244a. September 16, 2013

ATD LBS. PRESSURE BLASTER INSTRUCTION MANUAL

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Anti-flood device Model B-1

Agilent Auxiliary Gas Module AGM 2. User s Guide

AIRLINE-SERIES HELMET AIR FILTER

Parts List. Description. Additional Considerations. Installation Instructions. Dual/Elite Hydraulic Treadmill Kit (supplied by EPI)

JARVIS. Model CPE Hock and Neck Cutter EQUIPMENT... TABLE OF

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Interface Devices, Inc. Hydraulic Mini Mule

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

Instruction Manual Updated 7/26/2011 Ver. 2.2

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

CentriFlow Meter Specification Drawings Type II Configuration

Operating Instructions for Cobra and Lynx Duct Leakage Testers

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

TECHNICAL DATA CAUTION

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Build Your Own Flamethrower Step-by-step Manual

Side-of-Pole Mount for 1 Module (SPM1) For Module Type C

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Model 40H Nullmatic Pressure Regulators

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

RC 195 Receiver-Controller

BS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website:

Techcon Systems TS1258 Pressure Pot

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

FX134, FX1234, FX3030 Problem and Solutions

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

ModelsEZU-15 & EZU-15-R. BISHAMON INDUSTRIES CORPORATION 5651 East Francis Street Ontario, California 91761, USA (909) (800)

QBS Electronic Pressure Regulator

VOLUMATIC WATER REGULATOR

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Natural Gas to L.P. Gas Conversion Kit

Halsey Taylor Owners Manual

VRS Assembly & Operating Instructions

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Natural Gas to L.P. Gas Conversion Kit

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

SIGNATURE DEF REELS Models: Bare Reel Reel Reel Reel

PANACEA P100 LOW PRESSURE USER MANUAL

Transcription:

CentriFlow Meter Integrated Air Entrainment System INSTALLATION & OPERATION MANUAL January 2004 Revision 021-4 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website: www.easterninstruments.com Page 1 of 1

CentriFlow Meter Series IAE - 6, 12, 24, 36, 48 (Integrated Air Entrainment System) Installation Guide Purpose: The IAE system was designed to deliver an even stream of air to the CentriFlow Meter s. The use of this air is intended to aid in the cleaning of the. Its continuous, dry air should reduce buildup and assist in the flow of product on the measurement surface without affecting the measurement readings. Requirements: Included Components: Integrated Air Entrainment Device Oil Removal Filter Pressure Regulator & Gauge Seal Plate and Seal (as required for Type II installation) ½ NPT x 8 long Pipe Nipple ½ NPT x 2 long Pipe Nipple Hole Template (as required for Type II installation) Sheet Metal Screws (as required for Type II installation) IAE Mounting Hardware (Four ¼ -20 Head Screws) Also Required, Not Supplied:! Hex Key, 3/16! Screwdriver, Flat Blade! Air Tubing (Metal or Plastic see below)! Air Fittings (based on Table 1) with ½ NPT thread! Pipe Tape Compressed Air Line Sizes: Compressed air lines should be sized to hold pressure drops to a minimum (see Table 1). Do not use restrictive fittings or undersized lines that can starve the Integrated Air Entrainment system by causing excessive line pressure drop. If compressed air hose is used, always go one size larger than the recommended pipe size due to the smaller I.D. of hose. Recommended Infeed Pipe Sizes Single Installation Infeed Pipe Size, Length of run IAE Length 10' 50' 100' 6 1/4" 3/8" 1/2" 12 3/8" 1/2" 3/4" 24 1/2" 3/4" 1" 36 3/4" 1" 1-1/4" 48 3/4" 1" 1-1/4" Table 1 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website: www.easterninstruments.com Page 2 of 2

Installation: Depending on the configuration of the CentriFlow (i.e. Type I or Type II), the installation of the IAE system will vary. Follow the instructions closely to ensure a proper fit and to maximize the performance. Install the Shipping Locks to the CentriFlow Meter before anything else is done (See your CFM Manuals for help). Product flow must be turned off and access to the Assembly and is needed (see Figure 1). Use all precautions to care for the meter s. It should never come in contact with anything, including hands. The meter should be recalibrated after the installation of the IAE system is complete to compensate for the new flow conditions. Steps: 1. Install Shipping Locks as per CentriFlow manual. 2. Gain access to Assembly and (see Figure 1). For Type II, remove the meter from Type II enclosure. This can be accomplished by leaving the meter mounted and removing the enclosure or by leaving the enclosure mounted (if it can be held in place) and removing the meter. Refer to Removing the Type II enclosure document attached with this manual. 3. Remove the Guides and Liner by removing the Guide Mounting Hardware (see Figure 2) using a 3/16 hex key or screwdriver, depending on the hardware type. Keep in mind that once the hardware is removed from each Guide the Liner will be released. Ensure that Arm is not hit hard from side, top, or bottom during this step. Again, it is highly important that the Shipping Locks be in place before proceeding so as not to damage the Transducer, Flexures, or Column Wire. 4. Once the Liner is removed the Plate is exposed along with the Plate Mounting Hardware. Remove the Plate by using a screwdriver to remove the screws mounting the Plate to the (see Figure 3). Be careful not to drop the Plate on the. 5. Install the Integrated Air Entrainment system on the meter by mounting it to the using the hardware removed from the previous step. Using a screwdriver tighten the screws firmly so as to ensure that the IAE is attached to the spacers (see Figure 4). It is recommended that thread sealant be used on these screws to ensure that they do not come loose and get entrained into the product flowing through the meter. Be careful not to drop or rest the Integrated Air Entrainment System on the. 6. Attach the Guides using the Guide Mounting Hardware that were removed in step 3 (see Figure 5) using a 3/16 hex key or screwdriver, depending on the hardware type. 7. Connect 8-inch long ½ Pipe Nipple to ½ Street Elbow attached to the IAE Air Chamber located on the backside of the IAE system. For a Type I, this would be easily accessed behind the newly installed IAE and below the (see Figure 6). For a Type II, an access hole should be cut into the enclosure to allow the pipe nipple to be screwed into the street elbow through the wall of the enclosure (see Figure 7). A template has been provided to help in locating this EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website: www.easterninstruments.com Page 3 of 3

access hole (see Figure 10). To seal this opening to the outside a seal plate, seal and hardware are supplied. After the pipe nipple is firmly in place, place the seal over the pipe nipple and push it to the outside of the enclosure. Then place the seal plate over the nipple and push it to the seal. Then drill 1/8 holes by using the seal plate as a template to allow the seal assembly to be fastened to the enclosure with the provided hardware. Fasten the hardware to the enclosure with a wrench or screwdriver (see Figure 8). 8. Connect regulator and filter to the pipe nipple. The air being supplied to Integrated Air Entrainment system must be clean, dry, and debris free. Regulator specified will accept 100-psi inlet pressure, is adjustable to 50 psi, and the filter is 10-micron. Connect the outlet from the regulator to the ½ NPT connection (see Figure 9) by screwing the regulator to the nipple. Connect the 2-inch long ½ nipple to the inlet of the regulator and then screw the outlet of the filter to the other end of this nipple. 9. Connect air supply to regulator and filter assembly. Use table on page 2 of this manual to ensure that correct supply pipe is being used. 10. Turn on supply to regulator and adjust regulator to 10 psi. Ensure that airflow is felt at exit of Integrated Air Entrainment system, along flow path of, and at the discharge of the. If not, then contact Eastern Instruments. If air exiting Integrated Air Entrainment system is not enough to clear, than adjust regulator. However, if adjustment still does not get desired results even after it reaches 20 psi, then contact Eastern Instruments. 11. With air flowing, ensure that Manual Zero is adjust correctly according to CentriFlow Meter Electronics manual and follow Static Calibration procedure. Be aware that if the inlet pressure to the Integrated Air Entrainment system changes, this requires that the Manual Zero be rechecked or adjusted. 12. Check to see that Manual Zero is not changing due to airflow and then the system is ready for product. If Manual Zero is shifting, then contact Eastern Instruments. 13. The installation is now completed. Notes: The Integrated Air Entrainment system requires dry air and must remain clean to operate at peak levels. The purchased system doesn t contain an oil/water separator and the customer must ensure that the air is clean (provide their own separator). The supply line should be piped to a separator and then to the filter/regulator and then on to the IAE system. These should be installed as close to the IAE system as possible to reduce any condensation that could happen. EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website: www.easterninstruments.com Page 4 of 4

The graph below (Graph 1) shows the typical air consumption in SCFM vs. the inlet pressure in PSI into the Integrated Air Entrainment system. To determine the air consumption first look for the size of the Integrated Air Entrainment system in the legend, on the right side, and then follow the graph for the pressure setting on the regulator. 70.00 IAE Air Consumption Air Consumption (SCFM) 60.00 50.00 40.00 30.00 20.00 10.00 6 12 24 36 0.00 0.00 5.00 10.00 15.00 20.00 25.00 Pressure (PSI) Graph 1 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website: www.easterninstruments.com Page 5 of 5

Liner Guides Guide Mounting Hardware Figure 1 Page 6 of 6

Guide Mounting Hardware (6 Places - 3 per Guide) Liner Guides Hex Key (3/16") or Screwdriver Plate Figure 2 Page 7 of 7

Plate Mounting Hardware (4 places) Screwdriver Plate Figure 3 Page 8 of 8

IAE Mounting Hardware (4 places) Screwdriver Integrated Air Entrainment System Align Holes in IAE with Figure 4 Page 9 of 9

Guide Mounting Hardware (6 Places - 3 per Guide) Integrated Air Entrainment System Guides Hex Key (3/16") or Screwdriver Figure 5 Page 10 of 10

Integrated Air Entrainment System 1/2" NPT Street Elbow IAE Air Chamber Guides 1/2" NPT Pipe Nipple Integrated Air Entrainment System Figure 6 Guides Page 11 of 11

Ø 0.125 in 3.18 mm Typical (4 X) 1.937 in 49.20 mm 7.771 in 197.37 mm Ø 1.250 in 31.75 mm Figure 7 Page 12 of 12

Seal Plate Mounting Hardware (4 places) Screwdriver Type II Enclosure Pipe Nipple Seal Plate Seal Pre-Drilled 1/8" holes for sheet metal screws Figure 8 Page 13 of 13

Supply Air Line Inlet Regulator 1/2" NPT Pipe Nipple Filter 1/2" NPT Pipe Nipple Figure 9 Integrated Air Entrainment System Page 14 of 14

Template for cutting through hole for Pipe nipple in Type II Enclosure Figure 10 Page 15 of 15