GAS DEHYDRATION SYSTEM

Similar documents
GAS DEHYDRATION SYSTEM

GAS DEHYDRATION SYSTEM

SECTION P4 SEPARATION SYSTEMS

SEPARATION SYSTEMS. The Separation Systems consists of the Test Header (GAY-0302) and the Test Separator (MBD-4501).

SEPARATION SYSTEMS. Separator (MBD-1600) or the Wet Oil Tank, (ABJ-1800). Water is

SECTION P4 SEPARATION SYSTEMS

SECTION P4 SEPARATION SYSTEMS

GAS COMPRESSION SYSTEM

WELLHEADS, FLOWLINES & GAS LIFT INJECTION SYSTEMS

NORMAL OPERATING PROCEDURES Operating Parameter Information

From the Choke KO drum, the gas passes through another gas/gas exchanger - the 'LTS Pre-cooler'.

Start up XXX from normal shutdown Introduction

OPERATING PROCEDURES

Optimizing Effective Absorption during Wet Natural Gas Dehydration by Tri Ethylene Glycol

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Shell & Tube. JATCO Inc. Operating Manual

Digester Processes. 1. Raw Sludge Pumping System

Offshore Equipment. Yutaek Seo

Operating Instructions

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

PTRT 2470: Petroleum Data Management 3 - Facilities Test 4 (Spring 2017)

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Overview. OPIPOH10 - SQA Unit Code HG Operate an Oil and Gas Process ( Gas Treatment)

Lockout - Tagout. Control of Hazardous Energy OSHA Standard

Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Cycle Isolation Monitoring

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Hydraulic Reliability & Preventive Maintenance Report

Standard Operating Procedures

SHOP WELDED TANKS STANDARD CONNECTIONS

1. Study the performance of a binary distillation column operated in batch mode.

FlashCO2, CO2 at 23 $/ton

INTEROFFICE MEMORANDUM MODIFICATIONS TO DEW POINT CONTROL PROCESS

Spirax Compact FREME Flash Recovery Energy Management Equipment

Operating Instructions

Air Eliminators and Combination Air Eliminators Strainers

DEHYDRATION OF ACID GAS PRIOR TO INJECTION Eugene W. Grynia, John J. Carroll, Peter J. Griffin, Gas Liquids Engineering, Calgary, Canada

SAMSON SOLUTIONS Energy and Power (Critical Applications)

Reliability, Availability and Maintainability Report addressing sparing, RRM and turndown

F All types of inert gas systems are to comply with the following:

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

Bobtail DOT 407 / 412 Vacuum

HYDROGEN UNIT CHAPTER-4 UTILITY SYSTEM DESCRIPTIION

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Manual for continuous distillation

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents

Pressure Regulators. Operating Instructions. Instrumentation

GeQuip Joule Thomson Plant. Process Description (see Figure 1) Standard Control Instrumentation

Successful Implementation of Dry Gas Seal in High Pressure Recycle gas Compressor at Hydrocracker & Effect of Gas composition on DGS Performance

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435

OIL AND GAS SEPARATION DESIGN MANUAL

Portable Oil Lube Air Compressors

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

R E D I C O N T R O L S

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Avenger Model 33M Installation & Operation Instructions

TABLE OF CONTENT

Pressure Reducing Valve for Steam Type 2333 A

VENDOR SUPPLIED EQUIPMENT: ENSURING PSV DESIGN MEETS PSV SPEC

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

PHA and What-If Checklist Questions

Heat Pump Connections and Interior Piping

Armfield Distillation Column Operation Guidelines

OIL AND GAS PROCESSES AND EMISSIONS

Genie Supreme TM Model 123HP Installation & Operation Instructions

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Thermocirc Installation and Maintenance Instructions

QuickHeat TM Packaged Heat Exchanger Solutions

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Training Title IDENTIFY OPERATIONAL UPSETS, REVIEW & VALIDATE IN OIL & CHEMICAL PLANTS

Reclaim Basic Set Up

OPERATION MANUAL NTF-15

VT-0017 CWH OVERVIEW. intended provide PARTS NEEDED. a cryogenic tank. avoid gas from. proper PPE tanks & testing. LNG. Review.

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

TECHNICAL DATA. than the water inlet pressure to the concentrate

OPERATION AND MAINTENANCE MANUAL

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

TECHNICAL INFORMATION

OPERATION MANUAL NTF-60 Plus

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

2 Sentry MVS Installation, Operation & Maintenance

Eaton Filtration, LLC

Data Sheet Issue A

FAQs about Directive 017

2 Sentry MCL Installation, Operation & Maintenance

BACK PRESSURE / SUSTAINING

Wet scrubbers can be used for controlling. Wet Scrubbers for Dry Dust? Absolutely.

Journal of Chemical and Pharmaceutical Research, 2016, 8(5): Research Article

Type , , S2.20 Specialized test procedure Procedure for testing LPG bulk meters using a vapour displacement prover

Technical Information

Proper Pump Installation Practices

Transcription:

GAS DEHYDRATION SYSTEM High pressure and compressed gases flow through the Gas Scrubber (MBF-4540) to the Glycol Contactor (MAF-0900). In the Contactor, gas flows through trays, contacting the lean glycol that is flowing across the trays and down within the Contactor. The lean glycol, having a greater affinity for water than the gas, absorbs the water. The dehydrated gas then supplies the Fuel Gas System and Bi-Directional Gas Lift/Supply Pipeline, with excess being sold down the Departing Sales Gas Pipeline (KAH- 0701). Liquids scrubbed from the gas flow stream in the Gas Scrubber are dumped to the L.P. Separator (MBD-4530). Rich Glycol from the bottom of the Glycol Contactor flows through the Glycol/Glycol Heat Exchanger (HBG-0960) before entering the Glycol Flash Separator (MBD-0920). The Glycol Separator uses a pressure control valve to maintain backpressure with flash gas and there is a pressure control valve for Make-up Gas from the Fuel Gas System if needed. The Separator separates the gas, condensate, and glycol. The gas is vented to Vent Scrubber (MBF-4000). The condensate is dumped to the Emergency Oil Storage Tank (ABJ-3910). Glycol from the separator is dumped through the Glycol Sock Filter (MAJ-0930), Charcoal Filter (MAJ-0940), Glycol/Glycol Heat Exchanger (HBG-0950), into the Glycol Reboiler (BBC-0910). The Reboiler uses the Heat Medium System to supply sufficient heat to strip the absorbed water, which is vented out the top of the still column as steam. The lean glycol is collected in the Reboiler and then flows through both shell sides of the Glycol/Glycol Heat Exchangers to the suction of the electric motor driven Glycol Pumps (PBA-0970/0980). The lean glycol is finally pumped back into the top of the Glycol Contactor by the Glycol Pumps. The Glycol Pumps pump lean glycol through the Glycol/Gas Heat Exchanger (HBG-0900) back into the Glycol Contactor (MAF-0900). Rev: 1 Date: 7/26/12 Page 1 of 9 SS 182 A, A-Aux & C

A. PRE-STARTUP PROCEDURES NOTICE: Refer to Preliminary Considerations in SECTION 3, PART A before beginning any start-up procedures. GAS SCRUBBER & GLYCOL CONTACTOR: 1. Evaluate the situation and determine whether or not the Glycol Contactor should be bypassed a. Bypass the Gas Scrubber & Contactor if the facility is being started up and the Glycol Re-concentration System is not in service b. Bypass the Gas Scrubber & Contactor if the facility is being started up and approval is granted to send wet gas to the Gas Sales Pipeline (due to extended Glycol Re-concentration System shutdown) NOTICE: The Glycol Re-concentration System should be circulating glycol through the Contactor before gas is allowed to flow through the Contactor. 2. Verify that all vent and drain valves are closed on the system components a. Gas Scrubber, MBF-4540 b. Glycol Contactor, MAF-0900 3. Verify manual control valves are aligned to correctly direct flow a. If Scrubber/Contactor are bypassed, verify all valves are aligned so that only inlet/outlet and bypass valves need to be opened/closed when ready for startup (Note: it may be necessary to leave the inlet valve open during bypass for dump pressure) b. Verify gas flow stream is directed through the Gas Scrubber to the Contactor c. Verify gas flow stream is directed from the Contactor to the Departing Gas Pipeline Rev: 1 Date: 7/26/12 Page 2 of 9 SS 182 A, A-Aux & C

4. Verify that the liquid level controllers, pressure controllers, temperature controllers and control valves are ready for flow a. Gas Scrubber Liquid dump LC/LCV b. Glycol Contactor Back Pressure Valve PC/PCV H.P. Gas System relief PC/PCV (Note: this valve causes gas flaring) Glycol dump LC/LCV 5. Reset the Gas Scrubber/Glycol Contactor safety devices a. Verify that no safety devices are bypassed beyond those that must be bypassed for start-up (flag device as appropriate) on the Operator Interface b. Reset Gas Scrubber Safety Devices on the Operator Interface c. Reset Glycol Contactor Safety Devices on the Operator Interface d. Monitor and place safety devices in service as they clear WARNING: Any operating parameter that is monitored by a safety device must be continuously monitored at all times while the safety device(s) are in bypass. The bypassed safety devices (indicators) must be flagged while in bypass and reset as they come in-service. REFER TO: Section 3 Part A for further details on bypassed devices. Rev: 1 Date: 7/26/12 Page 3 of 9 SS 182 A, A-Aux & C

B. START-UP PROCEDURES GLYCOL RE-CONCENTRATION SYSTEM: WARNING: THERE ARE ALSO HEALTH HAZARDS ASSOCIATED WITH COMING INTO CONTACT WITH GLYCOL AND SOME OF THE HYDROCARBONS THAT MAY HAVE BEEN ABSORBED BY THE GLYCOL. AVOID CONTACT WITH GLYCOL AND CONSULT THE MSDS CAS #112-27-6 FOR DETAILED INFORMATION. 1. Verify that all vent and drain valves are closed through-out system a. Glycol Flash Separator, MBD-0920 b. Glycol Sock Filter, MAJ-0930 c. Glycol Charcoal Filter, MAJ-0940 d. Glycol Reboiler, BBC-0910 e. Glycol Pumps, PBA-0970/0980 2. Verify manual valves are open or closed as necessary to correctly direct flow through the system a. Verify glycol dump SDV from the Contactor remains closed until ready for circulation b. Verify that the flow path is open from downstream of Glycol Contactor dump SDV through the Glycol/Glycol Heat Exchanger, into the Glycol Flash Separator c. Verify that the Glycol Flash Separator condensate dump is open to the Emergency Oil Storage Tank d. Verify that the Glycol Flash Separator glycol outlet is open through the Glycol Filters and into the Glycol Reboiler e. Verify that the flow path is open from the Reboiler through the Heat Exchangers to the Glycol Pumps f. Verify that the flow path from Glycol Pumps discharge into the Glycol Contactor is open Rev: 1 Date: 7/26/12 Page 4 of 9 SS 182 A, A-Aux & C

3. Verify that the liquid level controllers, temperature controllers and control valves are ready for flow a. Glycol Flash Separator Blanket Gas PC/PCV Flash gas relief PC/PCV Condensate dump LC/LCV Glycol dump LC/LCV (downstream of Glycol Filters) b. Glycol Reboiler Heat Media Supply TC/TCV 4. Verify that the level in the Glycol Reboiler/Surge Tank is sufficient to avoid tripping the LSL WARNING: Do not overfill surge tank with glycol. Expansion of glycol as it is heated will cause the system to overflow. 5. Reset the Glycol Unit Shutdown Group a. Verify that no safety devices are bypassed beyond those that must be bypassed for start-up (flag device as appropriate) on the Operator Interface b. Reset Glycol Unit Safety Devices on the Operator Interface c. Pull the local manual reset relay to open Heat Media inlet to Glycol Reboiler Exchanger d. Monitor and place safety devices in service as they clear WARNING: Any operating parameter that is monitored by a safety device must be continuously monitored at all times while the safety device(s) are in bypass. The bypassed safety devices (indicators) must be flagged while in bypass and reset as they come in-service. REFER TO: Section 3 Part A for further details on bypassed devices. Rev: 1 Date: 7/26/12 Page 5 of 9 SS 182 A, A-Aux & C

6. Start-up the Glycol Pumps a. Verify that no safety devices are bypassed beyond those that must be bypassed for start-up (flag device as appropriate) on the Operator Interface b. Reset Glycol Pumps Safety Devices on the Operator Interface c. Verify Contactor glycol outlet SDV is open d. Press Start for the desired pump on the Operator Interface e. Monitor and place safety devices in service as they clear WARNING: Any operating parameter that is monitored by a safety device must be continuously monitored at all times while the safety device(s) are in bypass. The bypassed safety devices (indicators) must be flagged while in bypass and reset as they come in-service. REFER TO: Section 3 Part A for further details on bypassed devices. 7. Monitor the Reboiler temperature as it heats up to normal operating temperature (verify temperature controls are operational) 8. Monitor and reset any bypassed safety devices as they come inservice 9. Monitor Contactor glycol level and verify that the Contactor glycol dump is functioning 10. Verify glycol flow through the system by monitoring pressure differential across filters 11. Monitor Glycol Separator levels and verify that the dumps are functioning 12. Monitor the Reboiler to verify the temperature stabilizes at normal operating range 13. Continue to monitor the glycol level in the Reboiler to avoid tripping LSL 14. Continue facility start-up REFER TO: SECTION 3, PART B (step 28) Rev: 1 Date: 7/26/12 Page 6 of 9 SS 182 A, A-Aux & C

GLYCOL CONTACTOR: 15. If the Contactors are not bypassed, continue to monitor as facility is restored to full production 16. Take the Scrubber and Contactor out of bypass a. If necessary, SLOWLY open the inlet valve to the Scrubber/Contactor b. Open the gas discharge on Contactor c. SLOWLY close bypass valve to isolate flow to Scrubber/Contactor WARNING: Care should be taken to start the gas flow through the Contactor slowly. Flow surges will cause glycol to exit the Contactors out the gas outlet. 17. Continue to monitor the Glycol Re-concentration System 18. Once facility is at full production, and the Glycol Re-concentration System is at full operational temperature, verify there is adequate glycol level in the Reboiler 19. Immediately begin using the Normal Operating Procedures to continue to monitoring the system REFER TO: SECTION 5, PART I Rev: 1 Date: 7/26/12 Page 7 of 9 SS 182 A, A-Aux & C

C. SHUT-DOWN PROCEDURES NOTICE: Refer to Preliminary Considerations in SECTION 4, PART A before beginning any shut-down procedures. 1. If shutdown of the Gas Dehydration System will result in unapproved wet gas sales, facility shutdown may be required REFER TO: SECTION 4 (Facility Shutdown Procedure) NOTICE: Shutting down the Gas Dehydration System will result in gas sales with higher moisture content than may be allowed by contract requirements. 2. Place the Gas Scrubber & Glycol Contactor in bypass a. Open the Gas bypass valve b. Close the gas outlet valve from the Contactor 3. Close relay at the TCV for the Glycol Reboiler to divert flow and stop heating the Reboiler 4. Monitor the system as Glycol continues to circulate and cool down a. Monitor all system levels to ensure safe operating parameters 5. Close the inlet valve to Gas Scrubber 6. Place the Gas Scrubber in bypass (flag device as appropriate) on the Operator Interface 7. Shutdown the system and close the Contactor glycol dump on the Operator Interface 8. Isolate systems a. Close the manual valves on Contactor glycol inlets and outlets b. Close the manual valves on Glycol Flash Separator glycol and condensate dump lines Rev: 1 Date: 7/26/12 Page 8 of 9 SS 182 A, A-Aux & C

9. Open manual vent and drain valves as necessary to vent and drain components NOTE: If it is necessary to drain glycol from the system, store the glycol in clean containers for re-use. NOTICE: If shut-down was performed as preparation for maintenance work, or if the cause of the shutdown requires corrective action/repair, continue with Lock Out/Tag Out (LO/TO) Procedures REFER TO: Fieldwood Safe Work Practices for LO/TO (Section D Chapter 5) (can be found on the Fieldwood SEMS Portal) Rev: 1 Date: 7/26/12 Page 9 of 9 SS 182 A, A-Aux & C