Operating Instructions
|
|
- Sherman Nelson Hood
- 6 years ago
- Views:
Transcription
1 Operating Instructions Preparation for Start-up 1. If the computer system is logged off, log into the computer system. Log into the operator account on the computer. Please ask your TA for username and password. Click DeltaV Operate on the menu in the center of the screen 2. Check the fluid level in the reboiler using either the sight glass or the sensor data in the control system. The level should be around 50-70%. If the level is too high or too low, seek assistance from the TA/Lab Assistant. 3. Mix the contents of the reboiler: a. Close the transfer valve (see Figure 1). b. Open the recirculation valves (see Figure 1) c. Use the computer control system to turn on the reboiler mixing pump (see Figure 1). Let it mix for about 10 minutes. Figure 1. Overview of the East Column (EC) system on the 1 st floor. 4. While you are waiting: a. Check that the manual bypass valves on the distillate and reflux lines are closed (see Figure 2). 3-1
2 b. Check that the following control valves are set to the closed position in the control system: Distillate (2 nd floor, see Figure 2) Steam (1 st floor). c. Use the computer system to fully open the reflux control valve (see Figure 2). d. If you will be running at partial reflux conditions, check that the EC distillate tank located on the 1 st floor is empty (see Figure 1). If not, ask the TA to help you transfer content of the distillate tank to the reboiler. 5. Take a sample of the batch in the reboiler from the reboiler sample port (see Figure 1). 6. Use a Gas Chromatograph (GC) to determine composition of the reboiler content. Figure 2. Overview of the EC system on the 2 nd floor. 3-2
3 Note: Start-up The column should always be started at total reflux. It can be switched to partial reflux after it has reached a steady-state at total reflux. The sequence of turning on the utilities is the following: 1. Compressed air (low cost), required for operating pneumatic control valves. 2. Cooling water (somewhat expensive), required to prevent system from overheating. 3. Steam (highly expensive). The sequence will be reversed while turning the utilities off. Do not leave the column unattended. If a pneumatic valve malfunctions, use its corresponding manual bypass and notify the lab supervisor. Starting-up at Total Reflux 1. Manually open the air valves on the 1 st and 2 nd floors. 2. Manually open the main water valves on the 1 st and 2 nd floors. Water is needed for cooling the steam condensate (1 st floor) and condensing the top product (2 nd floor). 3. Use the control system to open the steam valve. Recommended steam flow rate is about 100 lb/hr. The temperature of the liquid in the reboiler should now be slowly rising. 4. While you are waiting for the column to warm up on Day 1, perform GC calibration. 5. After about minutes, you should see flow of the distillate from the condenser. The flow can be directly observed through a glass standpipe connected to the condenser (see Figure 2). 6. Allow a stable liquid level to be attained in the standpipe. If the standpipe starts overfilling, use the control system to turn on the reflux pump (see Figure 2) for a few seconds to drain the excess liquid. Reduce the steam flow rate to prevent recurring overfilling of the standpipe. 7. Start taking product samples to check whether the system has reached a steady-state. It is recommended to use reflux samples for this purpose, since the reflux sample port is located on the 2 nd floor and is close to the control room. Take samples at regular time intervals (10 minutes is recommended). It takes about an hour to reach a steady-state. Switching to Partial Reflux (Week 2) 1. Open and close appropriate manual valves to send distillate from the condenser on the 2 nd floor to the distillate tank on the 1 st floor. In particular, make sure that correct valves are open and closed around the EC distillate tank (see Figure 3). Note that valves with red tags should be kept closed while the column is operated at partial reflux. 3-3
4 2. Open the distillate control valve and adjust the reflux control valve to achieve a desired reflux ratio. Note that, in order to initialize flow through the distillate line, you may need to briefly turn on the reflux pump after you have opened the distillate valve. This is necessary to flush air out of the piping. Figure 3. East reboiler and distillate tanks (1st floor) 3. Take samples and measure the composition of the distillate and the bottoms at regular time intervals. 4. Periodically adjust the reflux and distillate valves to maintain constant reflux ratio (the valves need to be adjusted due to changes in the product composition over time, which leads to the change of the vapor flow rate). 5. At the end of each run, pump the material from the distillate tank back into the reboiler to ensure that the initial concentration for the next run is the same as in the pervious run. This makes comparison between different runs more meaningful. To transfer the content of the distillate tank back to the reboiler: a. Open the transfer valve (see Figure 1). b. Close the recirculation valves (see Figure 1). c. Ensure that appropriate valves are open and closed to enable fluid flow from the EC distillate tank (see Figure 3) to the transfer pump (located behind the distillate tank) and then to the reboiler. d. Use the computer control system to turn on the transfer pump. e. Stop the pump when the level in the distillate tank reaches zero. 3-4
5 Shutting Down 1. Use the computer system to close the steam control valve. Important: Use the manual mode of the valve control to ensure that it is fully closed (i.e. it is 0% open). This is necessary because the automatic mode is not guaranteed to fully close the valve, even if you set the flow rate to 0. The automatic valve controller stops closing the valve as soon as the steam flowmeter reads zero. Since the vortex steam flowmeter in our system is not designed to work at low flow rates, it is likely to read zero even when the valve is still slightly open. 2. Turn off the reboiler mixing pump. 3. If the system is running at partial reflux, return it to the total reflux: a. Open the reflux control valve to 100%. b. Close the distillate control valve. 4. Close the manual water and air valves on the 1 st floor. 5. Wait until the liquid flow in the standpipe is negligible. Use the reflux pump to drain any standing liquid from the standpipe. 6. Close the manual water and air valves on the 2 nd floor. 3-5
1. Study the performance of a binary distillation column operated in batch mode.
Goals for batch distillation using the East distillation column: 1. Study the performance of a binary distillation column operated in batch mode. 2. Determine the overall and local efficiency of the column
More informationManual for continuous distillation
Manual for continuous distillation 1. Week 1: Objectives: Run the column at total reflux. When steady state is reached, take the sample from the top and bottom of the column in order to determine the overall
More informationArmfield Distillation Column Operation Guidelines
Armfield Distillation Column Operation Guidelines 11-2016 R.Cox Safety SAFETY GLASSES ARE REQUIRED WHEN OPERATING THE DISTILLATION COLUMN Wear gloves when mixing alcohol feedstock The column will become
More informationOperating Instructions
Operating Instructions Before operating the thin film evaporator, please be aware of all safety concerns associated with this experiment: Burn hazard from the column and steam lines, Chemical hazards associated
More informationThe Discussion of this exercise covers the following points:
Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring
More informationCHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation
CHE 4115 Chemical Processes Laboratory 2 Experiment 1 Batch Distillation BACKGROUND Distillation is one of the most commonly used unit operations in chemical engineering. In general, a distillation operation
More informationOPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N
OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...
More informationCPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM
Faculty of Chemical Engineering CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM SUBMISSION DATE: 1 OCT. 2012 Question 1 Name the following equipments based on standard P&ID
More informationDynamics and Control of Chemical Processes Solution to Lab #8 Shutdown of C4-C5 separation section
Prof. Davide Manca Politecnico di Milano Dynamics and Control of Chemical Processes Solution to Lab #8 Shutdown of C4-C5 separation section RUN A DISTILLATION COLUMN USING HYSYS/UNISIM IN DYNAMIC MODE
More informationSomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings
SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.
More information2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.
Goals for Gas Absorption Experiment: 1. Evaluate the performance of packed gas-liquid absorption tower. 2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate. 3. Consider
More informationOperating Instructions
Operating Instructions Note: 1. Never let the centrifugal pump run dry. 2. Make sure that there is at least one open path for water flow in the pipe network before turning the pump on. Never run the pump
More informationExercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.
Exercise 5-2 Bubblers EXERCISE OBJECTIVE Learn to measure the level in a vessel using a bubbler. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Bubblers How to measure
More informationR E D I C O N T R O L S
R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature
More informationQuickHeat TM Packaged Heat Exchanger Solutions
4831999/1 IM-P483-03 CH Issue 1 QuickHeat TM Packaged Heat Exchanger Solutions Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
More informationOPERATING MANUAL LO-CROSS-FLOW CF M
VA FILTRATION USA 110 Dodd Court American Canyon, CA 94503 Tel : (707) 552 2616 Fax :(707) 552 3871 Web : www.vafiltration.com OPERATING MANUAL LO-CROSS-FLOW CF8-2-200M January, 2017 TECHNICAL SPECIFICATIONS
More informationCover Page for Lab Report Group Portion. Head Losses in Pipes
Cover Page for Lab Report Group Portion Head Losses in Pipes Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 February 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section
More informationCover Page for Lab Report Group Portion. Pump Performance
Cover Page for Lab Report Group Portion Pump Performance Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 March 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:
More informationOperating Procedures for Metal Evaporator I
Operating Procedures for Metal Evaporator I Metal Evaporator I is intended as a tool and a training device. Understanding the operation of this equipment should give you a basic knowledge of vacuum and
More informationTitle: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016
Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Xactix XeF2 Etcher. All users are expected to have read and understood this document.
More informationNavigator 600 Silica analyzers
ABB MEASUREMENT & ANALYTICS INFORMATION INF09/020 REV. B Navigator 600 Silica analyzers Troubleshooting Measurement made easy Navigator 600 silica analyzers 1 Introduction This publication details troubleshooting
More informationFlow meter. bellow vaporizer. APL valve. Scavenging system
Introductory Lecture Series: The Anesthesia Machine PORNSIRI WANNADILOK Objectives Anesthesia Machine Ventilators Scavenging Systems System Checkout 1 Flow meter ventilator bellow vaporizer Corrugated
More informationSpirax Compact FREME Flash Recovery Energy Management Equipment
IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.
More informationReverse Osmosis System Installation Guide and Operation Manual.
Reverse Osmosis System Installation Guide and Operation Manual. Table of Contents 1 Introduction...2 2 Installation...3 2.1 Feed water connection...3 2.2 Permeate and concentrate plumbing...3 2.3 Electrical
More informationGAS DEHYDRATION SYSTEM
GAS DEHYDRATION SYSTEM High pressure and compressed gases flow to the Glycol Contactor (MAF-3110). In the Contactor, gas flows through trays, contacting the lean glycol that is flowing across the trays
More informationMOL LNG Transport (Europe) Ltd File: 02 Checklists 6 pages Rev. No. 1 Loading Plan Part Two (2) (Line UP) Loading Plan Part Two (2) (Line Up)
Loading Plan Part Two (2) (Line Up) Arm Cool Down; Line Cool Down Line Up: Set up the port manifold as follows:. Open 20% No.1 tank filling valve CL100 Open 20% No. 2 tank filling valve CL200 Open 20%
More informationBy: Eng. Ahmed Deyab Fares - Mobile:
Distillation Column 1 Workshop Separation of light products is present in any Hydrocarbons operations. In this module, a column will be modeled to separate Light and heavy components from each other using
More informationGAM.org Score Posting How-to Guide
This guide will give you step-by-step instructions on how to post a score from www.gam.org on your computer or laptop. 1. Open the internet browser on your computer/laptop. 2. Go to www.gam.org. 3. Log
More informationSSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA
Page 1 of 9 SSI Solaris 150 RTA The Solaris 150 RTA is a rapid thermal annealing system capable of handling sample sizes up to 100mm (4 diameter) or smaller. The system can anneal in N 2 and Forming gas
More information5890II GC Standard Operating Procedure 9/2/2005
5890II GC Standard Operating Procedure 9/2/2005 This procedure is for the analysis of natural gas using the HP 5890II GC with the Restek ShinCarbon column. Detector Type: TCD Column Type: Restek Micropacked,
More information1.2 Example 1: A simple hydraulic system
Note: It is possible to use more than one fluid in the Hydraulic library. This is important because you can model combined cooling and lubrication systems of a library. The hydraulic library assumes a
More informationUBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions
Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM
More informationLaboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.
Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography
More informationCHE 306 Stagewise Operations
CHE 306 Stagewise Operations Fall 2010 Introduction ti to Column Distillation Instructor: Dr. Housam Binous KFUPM, Dhahran 1 Over 90% of separations are done using distillation Over 40 000 distillation
More informationKIV-SACS Safe automatic calibration system:
KIV-SACS Safe automatic calibration system: LOK: g:\prosjekter\calibration_system\kiv safe calibration system.doc Page: 1 of 14 Parts description:... 4 Wash extractors:... 6 Tunnel washers:... 5 Test valve:...
More informationStart up XXX from normal shutdown Introduction
Start up XXX from normal shutdown Introduction This procedure describes how to start a XXX after it has been shutdown normally, meaning there is a liquid and gas inventory in the unit. Task Criticality
More informationHigh-Pressure Boiler Inspection Procedures: A Complete Checklist
High-Pressure Boiler Inspection Procedures: A Complete Checklist Inspecting high-pressure boilers is a complex process requiring preparation, planning, and a multitude of safety precautions. Regular inspections
More informationGas Diluter Portable Gas Dilution System User s Manual
Gas Diluter Portable Gas Dilution System User s Manual Defiant Technologies, Inc. 2015 Vol.1 This page is intentionally left blank. Gas Diluter Portable Gas Dilution System User s Manual Defiant Technologies,
More informationfor Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)
for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity This is a Pilot operated pressure reducing valve. It is suitable to install in the steam lines with the
More informationPetrospace. User Manual. Desktop Refinery Simulation
Petrospace Desktop Refinery Simulation User Manual 1. Introduction 2. System requirements (minimum hardware specifications) 3. Installing the Petrospace software 4. Getting started 4.1 Refinery overview
More informationBoyle s Law: Pressure-Volume Relationship in Gases
Boyle s Law: Pressure-Volume Relationship in Gases The primary objective of this experiment is to determine the relationship between the pressure and volume of a confined gas. The gas we will use is air,
More informationLaboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.
Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions
More informationEZ-Boom 2010 Automated Application Control System Quick Reference Card INTRODUCTION
INTRODUCTION This figure shows the front panel of the EZ-Boom 2010 automated application control system. Status indicator Rate switch Rate Adjustment (Inc/Dec) switch Master switch Boom section switches
More informationAPI MPMS Chapter 17.6 Guidelines for Determining the Fullness of Pipelines between Vessels and Shore Tanks
API MPMS Chapter 17.6 Guidelines for Determining the Fullness of Pipelines between Vessels and Shore Tanks 1. Scope This document describes procedures for determining or confirming the fill condition of
More informationIn Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure
PPMS Service Note 1099-412 In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure Introduction: Loss of electricity to the PPMS EverCool II should not cause damage to
More informationGAS DEHYDRATION SYSTEM
GAS DEHYDRATION SYSTEM High pressure gases from the Gas Compressors (CBA-4070/4020) flow to the Glycol Contactor (MAF-1150). In the Contactor, gas flows through trays, contacting the lean glycol that is
More informationAdsorption Unit Operating Procedures: CO2 Adsorption on to Activated Carbon
Adsorption Unit Operating Procedures: CO2 Adsorption on to Activated Carbon Background Safety Concerns Description of the Unit Switching the Unit On Preparation of the Unit Configuration of the Unit for
More informationUSER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM
USER MANUAL OPERATION AND THE USE OF A CAR WITH Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM Page 2 / 8 Table of csontents 1. STARTING THE ENGINE... 3 2. CONTROL PANEL... 3 2.1 Indication of the current
More informationUniversity of Minnesota Nano Center Standard Operating Procedure
University of Minnesota Nano Center Standard Operating Procedure Equipment Name: Controlled Atmosphere Glove Box Model: Labconco Protector Location: PAN 185 Badger Name: Not on Badger Revision Number:
More informationCalibration of a GC955
Calibration of a GC955 1 Contents of the power point instructions Standard calibration Automatic validation methods and calibration of multi component mixes Autolinearisation: test of the linearity of
More informationTechnical Bulletin, Communicating with Gas Chromatographs
Last Updated: 13- July-2010 TB-080000C Technical Bulletin, Communicating with Gas Chromatographs OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land, Texas 77478 United States
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed
More informationGas Absorption Draft Standard Operating Procedure
Gas Absorption Draft Standard Operating Procedure R.C. 9-14 Scope Page 1 Equipment Overview Page 1 Safety Page 2 Operating Procedure Page 4 Equipment Description Page 16 Gas Absorption Experiment Draft
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationReduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology
Reduce Turnaround Duration by Eliminating H 2 S from Flare Gas Utilizing VaporLock Scrubber Technology Jim Woodard Vice President of Sales Bryant Woods Lead Project Engineer 4/3/18 Page 1 Objectives Impact
More informationRunning the LiCor 6400 Infra Red Gas Analyzer (IRGA) with 4 whole-plant cuvettes attached
Running the LiCor 6400 Infra Red Gas Analyzer (IRGA) with 4 whole-plant cuvettes attached Note: You must read the Primer manual Sections 1-6 before using the IRGA. The manual is located in the wall cabinet
More informationAKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:
1 AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by: Materials/Reagents/Equipment Vendor 1. 0.2 um filtered Water + 0.05% sodium azide 2. 0.2 um filtered
More informationIWCF Equipment Sample Questions (Surface Stack)
IWCF Equipment Sample Questions (Surface Stack) 1. During a well control operation 4000 psi was shut in below the middle pipe rams. Ram type BOP data: Model: Cameron U type Rated Working Pressure: 15000
More informationUser Manual for the Mars Calibration Bench
User Manual for the Mars Calibration Bench Fall 2013 Table of Contents Table of Contents Table of Contents... iii Introduction... v Chapter 1: The Mars Calibration Bench... 1 What Is the Mars Calibration
More informationHEATEC TEC-NOTE. Setting Siemens Pressure Transmitter. Used on Heatec Vertical Asphalt Tanks. Publication No , Revised
HEATEC TEC-NOTE, Revised 1-5-15 Setting Siemens Pressure Transmitter Used on Heatec Vertical Asphalt Tanks This document provides information on setting Siemens pressure transmitters used on Heatec vertical
More informationGAS DEHYDRATION SYSTEM
GAS DEHYDRATION SYSTEM High pressure and compressed gases flow through the Gas Scrubber (MBF-4540) to the Glycol Contactor (MAF-0900). In the Contactor, gas flows through trays, contacting the lean glycol
More informationVertical Tube Heat Exchanger (VTHX) or The Heat Exchanger Network (HEN) Control Process. Operating Manual
Vertical Tube Heat Exchanger (VTHX) or The Heat Exchanger Network (HEN) Control Process Operating Manual 1/17 9/4/2013 1. Background Heat exchangers are ubiquitous in the industrial world with millions
More informationAX5000 Operational Manual
MIYACHI AMERICA CORPORATION The World Leader in Hermetic Sealing Systems AX5000 Operational Manual 0 Document #107-00092-001 Dec, 2013 AX5000 Operational Manual Miyachi America Corporation 1820 S. Myrtle
More informationQUICK START GUIDE TO DRINKING WATER MONITORING
APPENDIX F QUICK START GUIDE TO DRINKING WATER MONITORING Introduction: This Quick Start guide is designed to allow users who are already familiar with the basic use of YSI 6-series sondes for surface
More informationDigital Level Control One and Two Loops Proportional and Integral Control Single-Loop and Cascade Control
Digital Level Control One and Two Loops Proportional and Integral Control Single-Loop and Cascade Control Introduction This experiment offers a look into the broad field of process control. This area of
More informationTD45 Thermodynamic Steam Trap Installation and Maintenance Instructions
0685255/1 IM-P068-47 ST Issue 1 TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operation
More informationQuantitative Analysis of Hydrocarbons by Gas Chromatography
Quantitative Analysis of Hydrocarbons by Gas Chromatography Introduction Gas-liquid chromatography (GLC) accomplishes a separation by partitioning solutes between a mobile gas phase and a stationary liquid
More informationLevel Process Control. Penn State Chemical Engineering
Level Process Control Penn State Chemical Engineering Revised Spring 2015 1 Table of Contents LEARNING OBJECTIVES... 3 EXPERIMENTAL OBJECTIVES AND OVERVIEW... 3 Pre-lab study... 3 Experiments in the lab...
More informationRevised: June 7, 2017
LC Technologies Thermal Evaporator Standard Operating Procedure Faculty Supervisor: Prof. Robert White, Mechanical Engineering (x72210) Safety Office: Peter Nowak x73246 (Just dial this directly on any
More informationOPERATION MANUAL NTF-15
OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE
More informationCoriolis Mass Flow Meter
Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;
More informationAutomatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
More informationAutomatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
More informationApplication Worksheet
Application Worksheet All dimensions are nominal. Dimensions in [ ] are in millimeters. Service Conditions Medium Through Valve: Required C v : Temperature Maximum: Minimum: Normal: Flow Maximum: Minimum:
More informationPRAHER PLC-MP AQUASTAR MANAUL 2009
PRAHER PLC-MP AQUASTAR MANAUL 2009 1. Copyrights This Operating Manual contains copyright-protected information. All rights reserved to Praher Kunststofftechnik GmbH. This Operating Manual is designed
More informationOPERATION MANUAL NTF-60 Plus
OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)
More informationFX134, FX1234, FX3030 Problem and Solutions
FX134, FX1234, FX3030 Problem and Solutions Unit Will Not Power Up Turn the power switch on. The unit LCD will display revision program and filter life within 3 to 5 seconds after turning on unit. If this
More informationDesign DSA Steam-Atomized Desuperheater
Instruction Manual DSA Desuperheater Design DSA Steam-Atomized Desuperheater Contents Introduction............................... 1 Scope of Manual......................... 1 Description..............................
More informationThe Discussion of this exercise covers the following points: Range with an elevated or suppressed zero Suppressed-zero range Elevated-zero range
Exercise 4-3 Zero Suppression and Zero Elevation EXERCISE OBJECTIVE In this exercise, you will learn the effect that mounting a pressure transmitter above or below the reference level has on the hydrostatic
More informationDri-Line Mk3 Monnier Compressed Air Drain Trap
5044050/2 IM-P504-24 CH Issue 2 Dri-Line Mk3 Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and Operation
More informationStandard Operating Procedure
Page 1 of 10 Vigor Glove Box Standard Operating Procedure Lab: ESB 154 Department: Materials Science and Engineering PI: Paul V. Braun Written By: Subing (Alan) Qu Section 1: Overview Type of SOP: Process
More information6800 Maintenance Instruction System Flush Procedure
Equipment Required FA74005 FA65318 FA900005 FA900003 Damper Drain Tube 6800 Cover Removal Tool Beaker 0.25 Litre Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves
More informationTABLE OF CONTENT
Page : 1 of 22 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia S) TABLE OF CONTENT SCOPE 2 VESSELS
More informationInstallation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914
Installation, Operating and Maintenance Instructions V914 Cast Iron Flanged Swing Check Valve V914 THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC and CE MARKING The Pressure Equipment Regulations 1999 (SI 1999/2001)
More informationInjection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS
TM INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS When the HI-FLO Metering Head is attached to a tank, the tank will be pressurized to the same pressure as the irrigation system. Before
More informationUNIVERSITY OF WATERLOO
UNIVERSITY OF WATERLOO Department of Chemical Engineering ChE 524 Process Control Laboratory Instruction Manual January, 2001 Revised: May, 2009 1 Experiment # 2 - Double Pipe Heat Exchanger Experimental
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are
More informationFisher DVI Desuperheater Venturi Inline
Instruction Manual DVI Desuperheater Fisher DVI Desuperheater Venturi Inline Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Installation... 3 Operating Instructions...
More informationDISTILLATION PRESSURE CONTROL TROUBLESHOOTING THE HIDDEN PITTFALLS OF OVERDESIGN
Distillation Absorption 2010 A.B. de Haan, H. Kooijman and A. Górak (Editors) All rights reserved by authors as per DA2010 copyright notice DISTILLATION PRESSURE CONTROL TROUBLESHOOTING THE HIDDEN PITTFALLS
More informationDischarge Relief Valve Operation & Maint.
Relief Valve Operation & Maint. CZ Series Centrifugal Fire Relief svalve Operation and Maintenance Instructions 1410 Operation and Maintenance Form No. F-1031 Section 2302.6 2111 Issue Date 04/90 11/95
More informationFire & Rescue Service Equipment Manual Branch - Foam Chubb FB5X Foam Making Branch Table of Contents 1 General Description Primary Function...
Fire & Rescue Service Equipment Manual! Branch Foam Chubb FB5X! 3 PREMIX 6 Fire & Rescue Service Equipment Manual Branch - Foam Chubb FB5X Foam Making Branch Table of Contents 1 General Description...
More information6900 Maintenance Instruction System Flush
Equipment Required FA74005 Damper Drain Tube FA16005 Cover Removal Tool FA900005 Beaker 0.25 Litre FA900003 Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves Latex
More informationCover Page for Lab Report Group Portion. Boundary Layer Measurements
Cover Page for Lab Report Group Portion Boundary Layer Measurements Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 30 March 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section
More informationCOMPRESSOR REPLACEMENT PROCEDURE (R-134A)
372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 COMPRESSOR REPLACEMENT PROCEDURE (R-134A) [ ] If possible operate the compressor with proper charge for 5 minutes
More informationDISTILLATION COLUMN PROCESS CONTROL STRATEGIES
DISTILLATION COLUMN PROCESS CONTROL STRATEGIES Satyajit Deshmukh 1, Salil Rajwade 2, Atharva Pundalik 3, Anil Ranveer 4 ABSTRACT 1,2,3,4 Chemical Engineering Department, Datta Meghe College of Engineering,
More informationREACTOR 40 MECHANICAL Configuration Guide
REACTOR 40 MECHANICAL Configuration Guide Important Safety Information WARNING See the Important Safety and Product Information guide in the product box for product warnings and other important information.
More informationTraining Title IDENTIFY OPERATIONAL UPSETS, REVIEW & VALIDATE IN OIL & CHEMICAL PLANTS
Training Title IDENTIFY OPERATIONAL UPSETS, REVIEW & VALIDATE IN OIL & CHEMICAL PLANTS Training Duration 5 days Training Venue and Dates Identify Operational Upsets, Review & Validate in Oil & Chemical
More information#LZ400 LEAKALYZER. Water Loss Sensor INSTRUCTION MANUAL Country Dr. #190 St. Paul, MN
#LZ400 LEAKALYZER Water Loss Sensor INSTRUCTION MANUAL 2885 Country Dr. #190 St. Paul, MN 55117 800-348-1316 www.leaktools.com Your Partner in Swimming Pool Water Conservation Product Purpose: 2 The Leakalyzer
More informationFRDS GEN II SIMULATOR WORKBOOK
FRDS GEN II SIMULATOR WORKBOOK Trotter Control Inc 2015 Document# Revision Revised 9001-0038 FRDS GEN II Simulator Workbook E 02/15/2015 by DC FRDS GEN II Simulator Workbook This workbook is a follow-on
More informationP-03 MAINTENANCE MECHANIC TRAINING SKILL DEVELOPMENT GUIDE
P-03 MAINTENANCE MECHANIC TRAINING SKILL DEVELOPMENT GUIDE Duty P: Steam Systems P-03: Perform Startup and Shutdown Procedures Issued 01/01/99 Perform Startup and Shutdown Procedures Task Preview Startup
More information