PyroCouple Series Operators Guide

Similar documents
OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Model PDT Dewpoint Transmitter

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Climatic Independent Level Sensor LAR

JUMO dtrans p30 Pressure Transmitter

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Pre-Calibrated Models

Ultrasonic level transmitter and indicator

Further technical information is available on

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

MODEL GT820 OXYGEN SENSOR

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

Expert Hydrostatic Level Transmitters

Infrared Linescanners

BS12 Piezoresistive OEM Pressure Sensor

Best Practice Guide, Servomex 2700

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

IP65 Air Differential Pressure Switch

Design Features. General Description

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

PURA. Pure Gas Dewpoint Transmitter. Users Guide

BS12N Piezoresistive OEM Pressure Sensor

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Climatic Independent Level Sensor LAR

Prewired position switches FA series

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

MODELS (2 foot Version) (4 foot Version)

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Position switches FP series

I/P Transducer Positioner Module

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Climatic Independent Level Sensor LAR

HI 2314 HI 2315 HI 23151

Climatic Independent Level Sensor LAR

SPD310/SPD360 Air Differential

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

EC214 EC215 - EC215R Bench Conductivity Meters

3.0 Pressure Transmitter Selection

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

FLAMMABLE GAS SENSOR/TRANSMITTER

Ultrasonic Wind Sensor

Transmitter CS 21 Operation Manual

Pressure Transmitters 36 F-27839

SITRANS P measuring instruments for pressure

FTC130 Transmitter. Operating Manual

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Precision pressure sensor Basic version Model CPT6020

Air Differentail Pressure Switch

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

OPTIBAR P 1010 C Technical Datasheet

EASIDEW TRANSMITTER with Current Source Output

Transmitter CS 21 Operation Manual

Pressure Transmitter P41

Bourdon tube pressure gauges for chemical applications EN 837-1

L3 Pressure and Level transmitter

AMT-Ex Dewpoint Transmitter

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

P900. P900, Datenblatt Seite 1 DESCRIPTION

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

Mass Flow Meter (MFM) for gases

PM105 PRESSURE METER USER S MANUAL

Pressure transmitter PASCAL Ci4

SonoMeter 30 Energy Meters

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

INSTALLATION & MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

Zirconia Oxygen Sensors. Model 1230 Series

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Digital Flow Switch. Series PFM7

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Mass Flow Meter (MFM) for Gases

Pressure Measurement Single-range transmitters for general applications

User s Guide Temperature Sensor Converter TSC-599

GasSense NDIR User Manual

Operating Instructions

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Visualize Nitrogen Gas Consumption

High-performance submersible pressure transmitter For level measurement Model LH-20

User Manual V14.1 IP68 LED FLEX NEON

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Ultrasonic Wind Sensor

Mass Flow Controller (MFC) for Gases

EGL-12 OIL-LESS COMPRESSOR

Operating Instructions

OXYGEN MONITORING SYSTEM OMS

Transcription:

PyroCouple Series Operators Guide

english PyroCouple, non-contact infrared sensors measure temperatures from -20 C to 500 C and provide either a linear 4 to 20mA output, a voltage output or a thermocouple output. This range of output signals is compatible with almost any indicator, controller, recorder, data logger etc., without the need for special interfacing or signal conditioning. They are suitable for most materials such as food, paper, textiles, plastics, leather, tobacco, pharmaceuticals, chemicals, rubber, coal and asphalt; but not materials with a low emissivity, for example polished metals. PyroCouple sensors are available as either two-wire or four-wire units. Two-wire PyroCouple sensors transmit the target temperature as a 4-20 ma output and offer a simple solution for most non-contact temperature measurement applications. Four-wire PyroCouple sensors transmit the target temperature as a 0-50 mv or thermocouple output (type J, K or T) plus the internal sensor temperature as a 4-20 ma output. This second output can be used to ensure that the sensor is being operated within the correct ambient temperature limits and prevent damage caused by overheating or overcooling. It can also be used to give an approximate indication of the air temperature surrounding the sensor. SPECIFICATION Temperature Range vs Field-of-View table Field of View -20ºC to 100ºC 0ºC to 250ºC 0ºC to 500ºC 2:1 PC21LT-X PC21MT-X - 15:1 PC151LT-X PC151MT-X PC151HT-X 30:1 PC301LT-X PC301MT-X PC301HT-X ø5mm @ 100mm PCCFLT-X PCCFMT-X PCCFHT-X Output table Model-X Target Temperature Output Sensor Temperature Output -0 4-20 ma Not available -1 0-50 mv 4-20 ma -2 Type T thermocouple 4-20 ma -3 Type J thermocouple 4-20 ma -4 Type K thermocouple 4-20 ma GENERAL Accuracy ±1% of reading or ±1 C whichever is greater Repeatability ±% of reading or ± C whichever is greater Emissivity 0.95 (fixed) Response Time 240ms (90% response) Spectral Response 8 to 14µm Supply Voltage 24Vdc (28Vdc max.) Sensor Voltage 6Vdc min. Maximum Loop Impedance 900 Ohms (4-20mA output) Output Impedance 56 Ohms (voltage/thermocouple output) MECHANICAL Construction Stainless Steel Dimensions 18mm diameter x 103mm Cable Length 1m Weight with Cable 95g ENVIRONMENTAL Environmental Rating IP65 Ambient Temperature Range 0 C to 70 C Relative Humidity 95% maximum non-condensing 2 SEN TRONIC AG Produkte, Support und Service

M16 x 1mm english 1000 12 103 18 ACCESSORIES A range of accessories to suit different applications and industrial environments is available. These may be ordered at any time and added on-site. The accessories consist of the following parts. Fixed mounting bracket Adjustable mounting bracket Air purge collar Laser sighting tool OPTIONS The following options are available. Options are factory installed and must be ordered with the PyroCouple. Air/water cooled housing Certificate of calibration Longer cable (30m max.) OPTICAL CHART The optical chart below indicates the nominal target spot diameter at any given distance from the sensing head and assumes 90% energy. 0 4 8 4.4 2.4 0 19.7 39.4 3.1 1.8 0 19.7 39.4 1.8 1.1 0 3.9 0.20 7.9 0.49 D:S 2:1 D:S 15:1 45.2 61.9 78.6 1 0 100 200 0 500 1000 PC21 PC151 D:S 30:1 28.6 45.2 0 500 1000 PC301 5.0 12.5 0 100 200 PCCF INSTALLATION The installation process consists of the following stages: Preparation Mechanical installation Electrical installation Please read the following sections thoroughly before proceeding with the installation. PREPARATION Ensure that the sensor is positioned so that it is focused on the target only. Sensor Target greater than spot size BEST Target equal to spot size GOOD Target smaller than spot size INCORRECT Background 3

english DISTANCE AND SPOT SIZE The size of the area (spot size) to be measured determines the distance between the sensor and the target. The spot size must not be larger than the target. The sensor should be mounted so that the measured spot size is smaller than the target. AMBIENT TEMPERATURE The sensor is designed to operate in ambient temperatures from 0 C to 70 C. For ambient temperatures above 70 C, an air/water-cooled housing will be required. Avoid thermal shock. Allow 20 minutes for the unit to adjust to large changes in ambient temperature. ATMOSPHERIC QUALITY Smoke, fumes or dust can contaminate the lens and cause errors in temperature measurement. In these types of environment the air purge collar should be used to help keep the lens clean. ELECTRICAL INTERFERENCE To minimise electromagnetic interference or noise, the sensor should be mounted away from motors, generators and such like. WIRING Check the distance between the sensor and the indicating/controlling device. If necessary, the PyroCouple sensor can be ordered with a longer cable attached. POWER SUPPLY Be sure to use a 24Vdc, (25mA) power supply. MECHANICAL INSTALLATION All sensors come with a 1m cable and a mounting nut. The sensor can be mounted on brackets or cut outs of your own design, or you can use the fixed and adjustable mounting bracket accessories which are shown below. Note: The sensor housing must be connected to earth at one point, either the cable shield termination or the sensor housing. Fixed Bracket Adjustable Bracket Ø16.0 15.0 12.0 9.0 60 Rotation 45.0 40.0 50.0 25.0 50.0 25.0 48.0 2 x Mounting Holes M4 Clearance 2 x Mounting Holes M4 Clearance 24.0 9.0 24.0 9.0 60 Rotation 60 Rotation 4 SEN TRONIC AG Produkte, Support und Service

AIR/WATER COOLED HOUSING The air/water cooled housing shown below allows the sensor to withstand high ambient temperatures. It is equipped with two 1/8 BSP fittings. Water temperature should be 10 C to 27 C for efficient cooling. Chilled water below 10 C is not recommended. To avoid condensation, the air purge collar should be used with the water-cooled housing. Water flow rate should not be more than to 1.5 litres/min. english 1/8 BSP water/air connections M16 x 1mm 19 63 103 21 40.0 AIR PURGE COLLAR The air purge collar below is used to keep dust, fumes, moisture, and other contaminants away from the lens. It must be screwed in fully. Air flows into the 1/8 BSP fitting and out of the front aperture. Air flow should be no more than 5 to 15 litres/min. Clean or instrument air is recommended. 1/8 BSP Air connection 25 APSW (PC21) 50 APSN (PC151, PC301, PCCF) 20 29 40 5

english ELECTRICAL INSTALLATION Two-wire units (option 0) PWR+ Power Supply + - - Display/Controller PWR- 4-20mA + 4-20mA = Target Temperature Four-wire units (options 1 to 4) Power Supply PWR+ + - - Display/Controller PWR- 4-20mA + 4-20mA = Sensor Temperature OP- OP+ - + Display/Controller mv/tc = Target Temperature OPERATION Once the sensor is in position and the appropriate power, air, water, and cable connections are secure, the system is ready for continuous operation by completing the following simple steps: 1. Turn on the power supply 2. Turn on the meter, chart recorder or controller 3. Read / monitor the temperature IMPORTANT Be aware of the following when using the sensor: If the sensor is exposed to significant changes in ambient temperature (hot to cold, or cold to hot), allow 20 minutes for the temperature to stabilise before taking or recording measurements. Do not operate the sensor near large electromagnetic fields (e.g. around arc welders or induction heaters). Electromagnetic interference can cause measurement errors. Wire must be connected only to the appropriate terminals. 6 SEN TRONIC AG Produkte, Support und Service

MAINTENANCE Our customer service representatives are available for application assistance, calibration, repair, and solutions to specific problems. Contact our Service Department before returning any equipment. In many cases, problems can be solved over the telephone. If the sensor is not performing as it should, try to match the symptom below to the problem. If the table does not help, call Calex for further advice. english Troubleshooting Symptom Probable Cause Solution No output No power to sensor Check power supply Erroneous temperature Incorrect wire connection Check wire colour codes Erroneous temperature Faulty sensor cable Verify cable continuity Erroneous temperature Field of view obstruction Remove obstruction LENS CLEANING Keep the lens clean at all times. Any foreign matter on the lens would affect measurement accuracy. Blow off loose particles (if not using the air purge accessory) with an air puffer. GUARANTEE Calex guarantees each instrument it manufactures to be free from defect in material and workmanship under normal use and service for the period of two years from the date of purchase. This guarantee extends only to the original buyer according to Calex terms and conditions of Sale. 7