LSG Single Point Failure Analysis

Similar documents
Installation and Operation Manual

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

Solenoid Valves used in Safety Instrumented Systems

BAPI Pressure Line of Products - FAQs

Improving distillation tower operation

Radar, Ultrasonic and RF Level Transmitters

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

GOLFER. The Golf Putting Robot

LEA_EN_PZL Dynamometric Scale. Instruments and Systems for Geotechnical and Structural Monitoring

AHE58/59 AC Servo System

Model 601CV. Mass Flow Controller. Product Features:

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

PEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review

Fail Operational Controls for an Independent Metering Valve

Partial Stroke Testing. A.F.M. Prins

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

Sensoric 4-20 ma Transmitter Board Operation Manual

Instrumentation & Data Acquisition Systems

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Aspects of gravimeter calibration by time domain comparison of gravity records

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE

Level MEASUREMENT 1/2016

Precision level sensing with low-pressure module MS

TH-1800-T TRX-700-CNG Converter

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Constant Pressure Inlet (CCN) Operator Manual

Next Generation Quartz Pressure Gauges

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors

IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications

Differential Pressure Transmiter

Specify the Right Remote Diaphragm Seal Solution for Vacuum Applications

Commissioning and safety manual

Electronic Volume Correctors

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Hitachi Differential Pressure/Pressure Transmitter

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

Technical Data Sheet MF010-O-LC

Roller AC Servo System

TSE Blood Pressure Monitor Invasive series

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

AMS 6916 Board mount pressure sensor with ratiometric analog output

Advanced Pump Control for Irrigation Applications

Cover Page for Lab Report Group Portion. Pump Performance

RC 195 Receiver-Controller

GATE 2 Part No

These Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1.

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE

M-System s I/P and P/I Transducers

LPG DRIVER ATTENDED TRANSPORT LOADING

SHORT COMMUNICATION A SIMPLE, SENSITIVE AND VERSATILE SOLID-STATE PRESSURE TRANSDUCER

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Space Simulation MARYLAND U N I V E R S I T Y O F. Space Simulation. ENAE 483/788D - Principles of Space Systems Design

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

VLT 2000 Series. How to size your VLT

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Ultima. X Series Gas Monitor

Quadair. Air Hockey Table Owners Manual. Assembly operation and care instuctions. Serial # Distributed By. Sales Person. Technical Service #

MIL-STD-883G METHOD

Model 4000 Pressure Controller

MODEL 60 DC BRUSHLESS ROTARY ACTUATAOR

Selecting the right pressure sensor for your application

ASDX Series Silicon Pressure Sensors

Lifespan Improvements Available in the Industry

Long term stability tests of INO RPC prototypes

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Air Compressor Control System for Energy Saving in Manufacturing Plant

Anemometry. Anemometry. Wind Conventions and Characteristics. Anemometry. Wind Variability. Anemometry. Function of an anemometer:

GAS FUEL VALVE FORM AGV5 OM 8-03

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

[Instruments for vacuum measurement, checking and adjustment] 3

AMS 6915 Board mount pressure sensor with digital output (I²C)

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

A4s Operation Manual

RP series Rotor Pumps

MODEL 20 DC BRUSHLESS ROTARY ACTUATAOR

PropaGator Autonomous Surface Vehicle

Design Features. General Description

1999 Microcomponents Technology SLYA017A

Section 2 Proportional Quick Exhaust

Project Title: Pneumatic Exercise Machine

SINGLE VALVE WITH LOW-FLOW BYPASS

SEC Signature DIR Process Monitor

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

Cryomodule Maintenance Workshop Maintenance, Repair Strategies, and Fault Scenarios. J. Ozelis Senior SRF Coordinator

Built-in Purge Control Functions

Gas Network Craftsperson

Instruction Manual Differential Pressure Transmitter

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

INSTALLATION & MAINTENANCE INSTRUCTIONS

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

AN31E Application Note

Space Simulation MARYLAND U N I V E R S I T Y O F. Space Simulation. ENAE 483/788D - Principles of Space Systems Design

Transcription:

NO. I RIEV. NC j ATM-929 1._&11..1 DATE 5/18/71 The purpose of this ATM is to comment on the results of the single point failure analysis conducted on the lunar surface gravimeter experiment. It is to be noted that this ATM does not include single point failure analysis on the La Coste and Romberg sensor. Approved by: S. J. Ellison, Manager A LSEP Reliability

I NO. ~REV. N( j.;:a...,.,...i.;l... -... o..,:;2;..; 0 ;...l J3 2 OF_ _ oate 5/18/71 INTRODUCTION This Single Point Failure Summary identifies those potential modes constituting single point failures or critical failures peculiar to the Lunar Surface Gravimeter. The reliability of the Lunar Surface Gravimeter is: Criticality I=. 92781, Criticality I plus II=. 92084, Criticality I plus II plus III==. 91220 (for two years mission). Failure modes listed in the following analysis are limited only to modes which: a. Cause the loss of all scientific data (criticality rank == I) b. Cause the loss of power (criticality rank = I) c. Cause the loss of housekeeping data (criticality rank = III) d. Cause the loss of the heater control system (criticality rank = I) e. Partial loss of scientific data (criticality rank= II) Failure modes with a criticality rank of "I" are termed LSG system single point failure modes. Those with a ranking of "II" are termed "critical". Failure modes with criticality rank III are less serious since scientific data is being returned. Critical failures are defined as those causing operational degradation of the LSG. SUMMARY The summary of the Single Point Failure is as follows: Criticality I = 24 Criticality II = 6 Criticality III = 1

NO.! REV. HO. ~ j A TM -9_2_9_t :r;,_ 3 6 OF- DATE 5/18/71 CONCLUSIONS Single point failures with rating of Criticality I, can only be eliminated by the use of redundancy. The fact is that power, weight, and volume budgets requirements are a constraint to the use of redundancy, but by the use of excellence in Quality Procedures, improvements in inspection and manufacturing processes, the application of high reliability component parts and accepted materials, and by the use of highly reliability design techniques, a high degree of confidence exists for successfully operating on the moon for 2 years. ANALYSIS 1. Fixed Gain Preamplifier - Failure will cause loss of the capability to obtain the sensor output. (Criticality I) 2. Post-amplifier - Failure will cause the loss of further amplification of the sensor output signal. (Criticality I} 3. Oscillator Bridge - Failure will result in the loss of the balanced AC voltage to the two fixed plates of the differential sensor, as well as the reference signal for later phase sensitive detection of the sensor A C output signal. (Criticality I) 4. Demodulator - Failure will result in the loss of capability to convert the AC input signal to the DC output signal. This signal is proportional to the sensor displacement and its polarity indicates the direction of the displacement. All scientific data will be lost (tidal, lunar free oscillation, lunar seismic activity, and the drift of the lunar gravin1eter sensor). Criticality I) 5. Integrator -Failure will result in the loss of capability of supplying a feedback voltage to restore the beam to a null position and is the output signal for lunar tidal variations. It will result in inability to record the effects of inherent gravimeter drift. (Criticality I) 6. Free modes filter - Failure will result in the anibility to accept the integrator output for filtering and further amplification. The sdentific data output from the filter represents the lunar free tnodes of oso...illation. (Criticality II}

NO. ~ ~fv. NC 'j 4 B DATE 5/18/71 7. Seismic Amplifier and Filter - Failure will result in inability to accept the seismic phase sensitive detector output in the demodulator. In a, degraded mode seismic information can be measured at the output of the Seismic Buffer. The scientific data output from this filter represents the seismic information. {Criticality II) 8. Tilt servo - Failure will result in the inability to provide means of making small changes in the angular alignment of the gravimeter sensor in order to affect the sensitivity of the sensor. The fine adjustment of gravimeter sensitivity will most likely be used in conjunction with the screw servo to optimize gravimeter performance. (Criticality I) 9. Screw servo - Failure will result in the inability to position the sensor beam to a null, Failure of the screw servo motors will cause this effect. The failure will be catastrophic in nature if it occurs before initial adjustments and set up on the lunar surface. (Criticality I) 10. Mass change servo - Failure will result in the inability to power the motors which operate the mass change mechanism within the gravimeter. The failure will be catastrophic in nature if it occurs prior to initial set up on the lunar surface. (Criticality I) 11. Caging Control - Catastrophic failure will result in the inability to uncage the sens0r beam. (Criticality I) 12. Shaft Encoder Electronics - Failure will result in the loss of data as to the position of the servo screw and loss of the relative of measurement. (Criticality II) 13. Temperature and Pressure Monitoring - Failure will result in the inability to monitor the gravimeter temperature and pressure. (If the gravimeter temperature cannot be held constant (50 oc) then the failure of the temperature monitor is cataloged as criticality I). 14. Instrument Housing Temperature Controller - Failure will result in the inability to control the current in a heater coil mounted on the external surface of the instrument housing so as to maintain the 0. 5" ± 0. 05 oc temperature differential between external surfaces of the h~ater box and instrument hok sing. (Criticality I)

NO. I REV. NO ATM-92Q j B 5 OF!:_ DATE 5/18/71 15. Heater Box Temperature Controller - Failure will result in the inability to control the current to the heater coil so as to maintain the set point within control limits. (Criticality I) 16. Power Converter - Failure will result in the inability to provide the required regulation, interference control, and isolation of all power functions within the LSC. Failure will be catastrophic in nature. (Criticality I) 17. Analog Multiplexer and A/D Converter - A failure of the analog multiplexer will result in the loss of capability to select any of the four signals. (Seismic, tide, free modes and temperature data). A failure of the A/D converter will result in the loss of capability to digitize the analog signal selected by the analog multiplexer when it is demanded. (Criticality I). 18. Digital Multiplexer and Ten-Bit Shift Register - Failure will result in the loss of capability to control and gate the flow of information from the four possible sources of data (from the A/D converter) into the shift register and then to the Central Station (ALSEP). (Criticality I) 19. Analog Output Buffers - Failure will result in the loss of ability to transmit to the ALSEP Central Station a portion of the ten analog data channels. (Criticality III) 20. Command Register, Decoder and Driver - Failure will result in the loss of capability of remotely programming the LSG to perform a specific operation. (Criticality I). 21. Digital Line Buffers and Receivers - Failure will result in the loss of buffering of the ALSEP command signals and timing and control pulses to LSG and the loss of command logics to the command counter, command decoder and driver and the loss of fan out capability of the timing and control pulses to all experiment functions. (Criticality I) 22. Conectors - Serves as electrical link between the electronics package and EEE parts internal to the instrument housing. Must withstand pressure between outside environment and instrument housing environment, failure of the counectors will result in the LSG failure (Criticality I)

NO. I R!V. MO. ATM-Q2Q I R PAGI 6 OP /l\erospace rstems Division DA Tl 5/1 8 I 71 6 23. Arrestment Drive - Provides caging service for sensor. Must operate to start experiment. If failure occur prior to uncaging the LSG experiment it will be catastrophic (Criticality I} 24. Mass Changing Drive - Provides three discrete balance points. Connects for local "g" level. Must operate initially for set-up. May be called upon to correct for changes in local "g'' level during experiment. Failure will result in the inability to change mass resulting in LSG catastrophic failure (Criticality I) 25. Potentiometer - Provides three position indicators for mass changing/ balance system. Failure will be catastrophic to LSG and result in inability to change mass. (Criticality I). 26. Screw Drive (Coarse) - Provides coarse balance point positioning. Servo loop control thru electro-static beam position output. Failure will be catastrophic to the LSG (Criticality I). 27. Screw Drive (fine) - Provides fine balance point positioning otherwise same as in item 26. Failure willbe catastrophic to LSG (Criticality I). 28. Leveling Drive - Provides a total of ::t: 6 minutes of arc connection to align with gravity vector. Failure will be l..ess el"' than critical. ( Criticality II). 29. Gimbal Suspension - Provides ::t: 3 o of pendulous freedom permitting sensor to align with gravity vector. Subject to stiction and wire torque restrictions. Failure will be greater than 6 minutes catastrophic to the LSG operation (Criticality I). 30. Thermal Control - Provides stable temperature environment for sensor. Failure will result in the inability to maintain temperature environment. It will compromise experimental results (Criticality I). 31. Pressure System - Consits of the instrument housing seals, and pressure monitoring sensor. Failure will compromise sensor data (Criticality II). 32. Encoder - Provides means of converting source sensor data into binary form for transmittal back to earth receiving station. Failure will be critical to LSG operation (Criticality II).