MODEL GENERA PURGE TURBINE INSTR DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

Similar documents
Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

OPERATING INSTRUCTIONS FOR MODEL

OPERATING INSTRUCTIONS FOR PRO HE HELIUM ANALYZER DANGER

RAM Operation Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021 Operation Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-DPX Operation Manual

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

RGC-IR Remote Gas Calibrator for IR400

Columbus Instruments

Thermal Conductivity Analyzer DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MODEL TURBO 2 TURBO 2 P PORTABLE TRACE OXYGEN ANALYZER INSTRUCTION MANUAL

ABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators

AK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators

INSTALLATION & MAINTENANCE INSTRUCTIONS

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

CSA Sample Draw Aspirator Adapter Operator s Manual

DPC-30 DPC-100. Reference Manual

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

RK-IR Sample Draw Aspirator Adapter Operator s Manual

311XL SERIES. 0-2 PPM Full Scale Trace Oxygen Analyzer DANGER

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

Digital Vacuum Regulator

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Overview. Front Panel: Keypad and Display

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

TECHNICAL INFORMATION

Constant Pressure Inlet (CCN) Operator Manual

Transmitter CS 21 Operation Manual

HumiSys HF High Flow RH Generator

92831 TEL: (714) FAX:

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

OEM Manual. MODEL ½ Digit DRUM SCALE

Workhorse-15 Oxygen Generator

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

MODEL 400 CLD INSTRUCTION MANUAL

MODEL GT820 OXYGEN SENSOR

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

Transmitter CS 21 Operation Manual

T EK-SUB 4800C 19 mm Submersible Level Transmitter

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

THE INSIDE STORY OF THE F-SERIES:

ACV-10 Automatic Control Valve

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Rosemount Analytical MODEL 755R OXYGEN ANALYZER INSTRUCTION MANUAL

Nitrogen Generation Systems

Operating Instructions

with O 2 Controller Instruction Manual

Mass Flow Controllers

TELEDYNE HASTINGS INSTRUMENTS PRELIMINARY BULLETIN. Models HFM-D-301 & 305, HFC-D-303 & 307

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Model EXAxt AV550G. Averaging Oxygen Analyzer

GasLab SAN-102 Micro Oxygen Monitor User Manual

! Warning, refer to accompanying documents.

BGA244 Binary Gas Analyzer

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

TECHNICAL INFORMATION

TELEDYNE HASTINGS INSTRUMENTS MODEL 40 POWER SUPPLY INSTRUCTION MANUAL

GAS FUEL VALVE FORM AGV5 OM 8-03

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Best Practice Guide, Servomex 2700

Operating Instructions Part No

Technical Information

Instruction Manual BA90 Precision Barometer

N2-14, N2-22, N2-35, N2-14A, N2-22A, N2-35A

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

Rosemount Analytical MODEL 755 OXYGEN ANALYZER INSTRUCTION MANUAL J

TECHNICAL INFORMATION

GasSense NDIR User Manual

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

KJL-205A. Operation Manual YOU MUST READ THIS MANUAL BEFORE USE

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Cover Page for Lab Report Group Portion. Pump Performance

FTC130 Transmitter. Operating Manual

Instruction and Maintenance Manual

Spirax Compact FREME Flash Recovery Energy Management Equipment

DIGIVAC 22W Series INSTRUCTION MANUAL. Wide Range Linearized Vacuum Transmitter and Controller YOU MUST READ THIS MANUAL BEFORE USE

In Vivo Scientific, LLC INSTRUCTION MANUAL

Model 356WA. Trace Oxygen Analyzer Instruction Manual DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

Model 106 DPI "Micro-switch" Installation and Operating Instructions

TECHNICAL INFORMATION

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Transcription:

275R MODEL 275R POR ORTABLE TURBINE GENERA ENERATOR PURGE GAS ANAL NALYZER INSTR NSTRUCTION MANU ANUAL AL DANGER HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM. PERSONAL PROTECTIVE EQUIPMENT MAY BE REQUIRED WHEN SERVICING THIS SYSTEM. HAZARDOUS VOLTAGES EXIST ON CERTAIN COMPONENTS INTERNALLY WHICH MAY PERSIST FOR A TIME EVEN AFTER THE POWER IS TURNED OFF AND DISCONNECTED. ONLY AUTHORIZED PERSONNEL SHOULD CONDUCT MAINTENANCE AND/OR SERVICING. BEFORE CONDUCTING ANY MAINTENANCE OR SERVICING CONSULT WITH AUTHORIZED SUPERVISOR/MANAGER. P/N M51353 03/29/01 ECO # 01-0115

Copyright 1999 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne Analytical Instruments, 16830 Chestnut Street, City of Industry, CA 91749-1580. Warranty This equipment is sold subject to the mutual agreement that it is warranted by us free from defects of material and of construction, and that our liability shall be limited to replacing or repairing at our factory (without charge, except for transportation), or at customer plant at our option, any material or construction in which defects become apparent within one year from the date of sale, except in cases where quotations or acknowledgements provide for a shorter period. Components manufactured by others bear the warranty of their manufacturer. This warranty does not cover defects caused by wear, accident, misuse, or neglect. We assume no liability for direct or indirect damages of any kind and the purchaser by the acceptance of the equipment will assume all liability for any damage which may result from its use or misuse. We reserve the right to employ any suitable material in the manufacture of our apparatus, and to make any alterations in the dimensions, shape or weight of any parts, in so far as such alterations do not adversely affect our warranty. Important Notice This instrument is intended to be used a tool to gather valuable data. The information provided by the instrument may assist the user in eliminating potential hazards caused by the process that the instrument is intended to monitor; however, it is essential that all personnel involved in the use of the instrument or its interface with the process being measured be properly trained in the process itself, as well as all instrumentation related to it. The safety of personnel is ultimately the responsibility of those who control process conditions. While this instrument may be able to provide early warning of imminent danger, it has no control over process conditions, and can be misused. In particular, any alarm or control system installed must be tested and understood, both as they operate and as they can be defeated. Any safeguards required such as locks, labels, or redundancy must be provided by the user or specifically requested of Teledyne. The purchaser must be aware of the hazardous conditions inherent in the process(es) he uses. He is responsible for training his personnel, for providing hazard warning methods and instrumentation per the appropriate standards, and for ensuring that hazard warning devices and instrumentation are maintained and operated properly. TAI, the manufacturer of this instrument, cannot accept responsibility for conditions beyond its knowledge and control. No statement expressed or implied by this document or any information disseminated by the manufacturer or his agents is to be construed as a warranty of adequate safety control under the user's process conditions.

Table of Contents 1.0 INTRODUCTION 1.1 Features... 1.1 2.0 OPERATIONAL THEORY 2.1 Thermal Conductivity... 2.1 2.2 Electronic Components... 2.2 3.0 OPERATIONS 3.1 Front Panel... 3.1 3.1.1 Function Switch... 3.1 3.1.2 Zero Control... 3.1 3.1.3 Span Control... 3.1 3.1.4 Cell Temperature... 3.1 3.1.5 Flowmeter... 3.1 3.1.6 Analog Meter... 3.2 3.1.7 Analog Output... 3.2 3.2 Start-Up... 3.2 3.2.1 Preliminary... 3.2 3.2.2 Flowrates... 3.2 3.2.3 Calibration... 3.2 4.0 INSTALLATION 4.1 Locations... 4.1 4.2 Electrical Connections... 4.1 4.3 Gas Connections... 4.2 4.3.1 Gases... 4.2 4.3.2 Vent Lines... 4.2 4.4 Pressure Regulation... 4.3 5.0 MAINTENANCE & TROUBLESHOOTING... 5.1 6.0 Appendix Specifications... A.1 Calibration Data... A.2 Spare Parts List... A.3

Drawing List... A.4 CAUTION Do not connect the instrument to a pressure source greater than 30 psig. This is a measurement instrument, NOT a safety instrument. This instrument is NOT explosion-proof or intrinsically safe and MUST NOT be used in hazardous areas.

Introduction 1.0 Introduction In order to help you make maintenance purging of turbine generators safer, Teledyne Analytical Instruments has developed the 275R Turbine Generator Purge Gas Analyzer. During maintenance of hydrogen-cooled turbine generators, the cooling gas (H 2 ) is systematically replaced with carbon dioxide (CO 2 ) and then air. The 275R accurately measures H 2 concentrations during the replacement process by comparing the difference in thermal conductivities between a sealed reference gas (helium) and the atmosphere undergoing replacement. Since air leaks reduce the purity of H 2 used in cooling, which increases viscosity and reduces heat conduction, the 275R has a H 2 -in-air range in order to assist in monitoring H 2 and impurity concentrations for optimum efficiency during normal operations. 1.1Features The Model 275R analyzer has three ranges for purge and normal generator operation, with zero and span potentiometers for each. Each range also has its own scale on the meter face. Efficient insulation around the cell block enables quick restarts so that the instrument can be carried from one generator to the next without a lengthy warm-up period. Periodic calibration is all the maintenance necessary. Installation is just a matter of connecting sample inlet and outlet lines. The reference cell is sealed; thus, no other gas connections are necessary. Electronic temperature control in the cell block insures optimum accuracy in measurement. 1.1

1.0 Introduction 1.2

Operational Theory 2.0 Operational Theory The Model 275R Turbine Generator Purge Gas Analyzer can measure either the concentration of one component in a binary stream of gas, or the purity of a sample stream containing a composite mixture of impurities. 2.1Thermal Conductivity The ability of a substance to conduct heat is called thermal conductivity. A good heat conductor has a large thermal conductivity (as in the case of hydrogen and helium, which have nearly identical thermal conductivities); a small thermal conductivity (as in chlorine and carbon dioxide gas) indicates that the substance may be a better insulator than conductor. Operation of the 275R analyzer is based on being able to detect the difference in thermal conductivity between the gas being monitored and the known reference (which, in this case, is helium). Thermal conductivity measurements are non-specific by nature, which imposes certain limitations and requirements. If the analyzer is to detect a specific component in a sample stream, the sample must be composed of the component of interest and one other gas in order to be accurate. If, on the other hand, the user is primarily interested in the purity of a process stream, and does not require specific identification of the impurity, the analyzer can be used on more complex mixtures. Because analysis by thermal conductivity is not an absolute measurement, standardizing gases of known compositions will be required to zero and span the analyzer. The detector cell is divided into two halves, with the reference gas (helium) sealed into one chamber, and the other through which the sample flows. The difference in thermal conductivity between the reference gas and the sample is sensed by hot wire elements, which protrude into the chambers. Each pair of elements is wired into an electrical circuit known as a Wheatstone bridge. 2.1

2.0 Operational Theory During calibration, the bridge circuit is balanced with the reference gas; the zero of each range is set with its zero gas and the high end of the range is adjusted with span gas. The intervening points along the range (or ranges) of interest will produce a DC electrical signal representative of the analysis. 2.2 Electronic Components The temperature of the measuring and reference cell block is regulated to within 0.1 C by means of an electronic proportional controller circuit. The cell block is mounted on an aluminum heater block and insulated. A thermistor is used in the circuit to keep the heater block at a predetermined temperature. A regulated current supply of approximately 100 milliamperes supplies stable temperature-independent power to the sensor elements in the chambers. Since the elements are connected to the four arms of the Wheatstone bridge, a gas with a thermal conductivity different from the reference creates an imbalance in the bridge in proportion to the thermal conductivity of the sampled gas. This signal is amplified and displayed. The output of the final buffer amplifier is normally 1 volt full scale, and is powered by a standard TAI power supply unit of +15V and -15V.

Operations 3.0 Operations 3.1 Front Panel 3.1.1 Function Switch This switch is used to select the gas mixture range to agree with the composition of the sample. Gas compositions for which your analyzer is intended are hydrogen and carbon dioxide (0-100% H 2 in CO 2 ), or air and carbon dioxide (0-100% air in CO 2 ), or purity of hydrogen (e.g. 90-100% H 2 with 0-10% impurities). 3.1.2 Zero Control The zero control potentiometers are used to adjust the zero reading for each range when a zero gas is introduced into the analyzer. See Appendix: Specifications for the recommended zero gas. 3.1.3 Span Control The span control potentiometers are used to adjust the meter to read the known concentration of a span gas present in the measuring chamber. See Appendix: Specifications for the recommended span gas. * 3.1.4 Cell Temperature Generally the cell temperature is stable within 30 minutes of switching on the analyzer. The indicator lamp on the front panel shows when the heater is on, and when it is flashing the cell is up to its operating temperature. 3.1.5 Flowmeter The flowmeter is used to control and adjust the sample (or span or zero) gas flow through the measuring chamber. 3.1

3.0 Operations 3.1.6 Analog Meter The meter has three scales: 0-100% H 2 in CO 2 (green). 0-100% air in CO 2 background (black). 90-100% H 2 in air (red). The output of the circuitry for the 0-100% H 2 in CO 2 scale is nonlinear with the most sensitive area being at the low end. The other two scales are almost linear. A special meter dial is provided with markings located to accommodate these non-linearities so that extrapolation is not required. 3.1.7 Analog Output A 0-1 VDC output is provided. This output is non-linear and must be interpreted using the curves in the Appendix. The load on this signal must be less than 10,000 Ω to ensure that it will not cause error in the output signal. 3.2 Start-Up 3.2.1 Preliminary 1. Check that the inlet and outlet lines have been connected to the proper ports in the rear of the analyzer, and that all the lines are leak-free. 2. Plug the power cord in. 3. Turn the analyzer power switch ON. The switch is located on the lower left-hand corner of the front panel. 4. Allow the analyzer to warm up until the lamp starts flashing. Allow 15 more minutes of warm-up. 3.2.2 Flowrate The gas flowrate should be approximately 0.1 SCFH, at 10 psi pressure. 3.2.3 Calibration 1. With 100% CO 2 flowing through the cell, adjust the zero control potentiometer so that the meter reads zero for Range 1 and Range 2 of the analyzer. 3.2

Operations 3.0 2. With a mixture of 90% H 2 and 10% N 2 flowing through the analyzer, adjust the zero control potentiometer to read zero on the meter for Range 3. 3. With 100% H 2 flowing through the cell, adjust the span controls to read full scale output in Ranges 1 and 3. 4. With air flowing through the cell, adjust the span control to read full scale output in Range 2. After calibration has been successfully concluded, connect the sample gas to the analyzer, and adjust the flow to approximately 0.1 SCFH. 3.3

3.0 Operations 3.4

Installation 4.0 Installation 4.1 Location WARNING: This instrument is not explosion-proof or intrinsically safe, and MUST NOT be used in hazardous areas. The instrument should be installed where it will not be subjected to: direct sunlight. drafts. shock and vibration. temperatures below 30 F or above 110 F. The analyzer should be placed as close as possible, subject to the above conditions, to the sample point, to minimize the effects of sample line lag time on the analysis. An outline diagram showing the location and identification of the gas and electrical connections, as well as the physical dimensions of the analyzer case, is included in the drawings at the rear of the manual. 4.2 Electrical Connections. A source of single phase, 50 or 60 Hz, 110 to 120 volt power, capable of delivering 1 ampere of current continuously, is required to operate the analyzer. 220 volt is available upon special order. The primary power connection is made by connecting the line cable to the receptacle at the back of the instrument. Use 2-conductor shielded cable (nominally #22 ga. wire size) to interconnect the analyzer output signal with any recording equipment. The shield should be terminated on the appropriate terminal (see interconnection diagram) at the analyzer, and be left disconnected at the recorder. 4.1

4.0 Installation 4.3 Gas Connections The gas inlet and outlet connections are 1/8" tube fittings located on the upper left-hand corner of the rear panel. NOTE: Reducing-type pressure regulators will have to be installed at all gas supply sources. * 4.3.1 Gases Air, hydrogen, carbon dioxide and a mixture of 10% nitrogen in hydrogen are needed to calibrate the unit. WARNING: Hydrogen is a highly flammable gas. Care should be taken not to store it near flames or flammmable materials. The output from the analyzer should be purged to a remote space, away from ignition and ignitable sources. 4.3.2 Vent Lines The selected gas introduced into the sample path of the cell is vented through the gas outlet fitting. If it is desirable to carry the outlet gas to an area remote from the analyzer to vent it, the following precautions must be observed in vent line installation: a) The vent line should be constructed of tubing of sufficient diameter so that no appreciable back pressure resulting from restricted flow is experienced by the analyzer. b) The sample line must be vented into an area where the ambient pressure is the same as that of the analyzer. c) The ambient pressure in the vent area must undergo no more than normal barometric pressure changes. d) The vent line must be installed so that water cannot accumulate in it. 4.2

Installation 4.0 4.4 Pressure Regulation The following precautions must be observed for the incoming gas lines: a) The incoming gas line should be equipped with a pressure regulator. b) The sample line pressure regulator should be installed as close to the sample point as possible, to minimize sample line lag time. c) Sample pressure should be set somewhere between 5 and 30 psig; 10 psig is nominal. d) To minimize flowrate adjustments, the pressure regulators on the supporting gas supply cylinders should be adjusted to provide the same output pressure as the sample line regulator. NOTE: When installing pressure regulators on supply cylinders, open the cylinder valves slightly so that gas is flowing during installation. Using this procedure will eliminate the diffusion of air trapped during assembly back into the cylinder, the most common cause of standardization gas contamination. 4.3

4.0 Installation 4.4

Maintenance & Troub oubleshooting 5.0 Maintenance & Troub oubleshooting Since no moving parts are used in the analyzer, no routine maintenance is required, other than checking the gas flow rate periodically. Symptom 1. No output. 2. Output drifting very slowly. 3. Output goes high slowly when the instrument is first turned on. Cause a) Bad fuse. b) The power supply of +15V and -15V may be defective. c) The bridge power supply (100 ma) may be defective. a) Blocked vent may be causing back-pressure in the measurement cell, resulting in high cell pressure, erratic readings, and a constricted flow. a) The temperature controller may not be working. What To o Do a) Check and replace fuse. b) If faulty, change the power supply board. c) Measure it, and if faulty, change the voltage regulator/amplifier board. a) Clean the vent. a) Check that the bulb above the power switch is flashing, and if the bulb is not flashing, change the temperature controller board. b) If the temperature controller is working, perform the same checks as in #2 above. 5.1

5.0 Maintenance & Troub oubleshooting 5.2

Appendix Appendix Specifications Ranges: 0 100% H 2 in CO 2 0 100% air in CO 2 90 100% H 2 in air Sealed reference gas: Zero drift: Accuracy: Response time: Sample flowrate: Area classification: Signal output: Meter readout: Operating temperature: Electrical requirements: Approximate dimensions: Approximate weight: Helium <1% per day ±5% of full scale or better, depending on the range selected. 90% in 50 seconds. 0 to 0.5 SCFH. General purpose (non-hazardous) areas. 0 to 1 VDC. mvdc output also available. Integral analog meter. +32 to +125 F (0 to +52 C). 115 VAC, 60 Hz, 115 Watts. 100 or 220 VAC, 50/60 Hz also available. H W D 9 " 10 " 14 " 230 mm 250 mm 360 mm analyzer: 10.5 lbs. (4.8 kg). power cord: 0.7 lbs. (0.3 kg). A.1

Appendix Calibration Data Serial Number: Ranges: 0-100% H 2 in CO 2 0-100% air in CO 2 90-100% H 2 in air Output Signal: 0-1 VDC Recommended Zero Gases: 100% CO 2 90% H 2 with 10% N 2 Recommended Span Gases: 100% H 2 100% air Reference Gas: Sealed helium reference A.2

Appendix Recommended Spare Parts List P/N QTY. DESCRIPTION C-51407 1 PC board, measurement B-30927 1 PC board, amplifier A-9306 1 PC board, power supply B-73363 1 Cell block assembly F9 5 Fuse, 1 amp H158 1 Heater, 18 watt cartridge type A minimum charge of $150.00 is applicable to spare parts orders. IMPORTANT: Orders for replacement parts should include the part number (if available) and the model and serial number of the system for which the parts are intended. Send orders to: Teledyne Analytical Instruments 16830 Chestnut Street City of Industry, CA 91748-1580 Telephone: (626) 961-9221 TWX: (910) 584-1887 TDYANYL COID FAX: (626) 961-2538 EASY LINK: 62831862 or contact your local representative A.3