Instruction and Maintenance Manual

Similar documents
Instruction and Maintenance Manual

Columbus Instruments

Technical Data Sheet MF010-O-LC

FTC130 Transmitter. Operating Manual

Transmitter CS 21 Operation Manual

GasSense NDIR User Manual

Mass Flowmeters. Mass Flowmeters for Gases

Datasheet: K-30 ASCII Sensor

Installation and Operation Manual

Model 601CV. Mass Flow Controller. Product Features:

Model PDT Dewpoint Transmitter

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

ACV-10 Automatic Control Valve

Transmitter CS 21 Operation Manual

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

INSTALLATION & MAINTENANCE INSTRUCTIONS

ISM-3 User Manual PBI D 04/2013

Sensoric 4-20 ma Transmitter Board Operation Manual

MANUAL KPS Pressure Control Valve

O3 3E 1 F Gas Sensor Module

This test shall be carried out on all vehicles equipped with open type traction batteries.

Mass Flow Controller (MFC) for Gases

AMT-Ex Dewpoint Transmitter

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Mass Flow Meter (MFM) for Gases

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

UNDERSTANDING, ACCELERATED

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Installation, operating and maintenance Instructions for Seemag bypass level indicator

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Mass Flow Controller (MFC) for Gases

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

SX150A. Features. Typical Applications. Description

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

BS12 Piezoresistive OEM Pressure Sensor

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Manual Oxygen Analyzer A4009T

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

EPP4 Pressure Regulator Basic G 1/4"

AMS 6916 Board mount pressure sensor with ratiometric analog output

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Constant Pressure Inlet (CCN) Operator Manual

Electrochemical Sensor

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Mass Flow Controller (MFC) for Gases

Specifications of Oxygen Sensor Module V-8344A

The Univentor 1250 Anaesthesia Unit

FLAMMABLE GAS SENSOR/TRANSMITTER

OXY 3690 MP. Measuring transducer for air oxygen

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

[Instruments for vacuum measurement, checking and adjustment] 3

BS12N Piezoresistive OEM Pressure Sensor

User manual CF8-D/W-IN

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

86BSD Backside Digital Output

Installation and Operation Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Technical Information Conducal CLY421

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Manual of SF6 Comprehensive Tester

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Electrochemical Sensor

Highest Quality. Gas Chlorination Systems

ME3-HCL Electrochemical sensor

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

HBLT-A1 LIQUID LEVEL SENSOR

Advanced Test Equipment Rentals ATEC (2832)

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

SITRANS P measuring instruments for pressure

ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

RAM Operation Manual

Precision pressure sensor Basic version Model CPT6020

SPECIFICATIONS ATTENTION

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

Simrad GD10P Extended On-site Maintenance

RAM 4021-DPX Operation Manual

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Mass Flow Meter (MFM) for gases

Overview. Front Panel: Keypad and Display

BUBBLER CONTROL SYSTEM

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

RAM 4021 Operation Manual

Generating Calibration Gas Standards

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

AMS 2710 PCB pressure sensor module with V output

Oxygen Measurement Systems High Reliability and Wide Application Coverage

SonoMeter 30 Energy Meters

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Design Features. General Description

AMS 6915 Board mount pressure sensor with digital output (I²C)

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Transcription:

Instruction and Maintenance Manual GRYF OXY ZM 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 www.gryf.eu ver.: 11.2.2015

OEM module for measuring oxygen concentration with the ZrO2 sensor Technical parameters Supply voltage 24 V/dc ± 10% Supply current 500 ma Output signal 4 20 ma Oxygen concentration range 0.2 100% Sensitivity 0.01% (0.2 5%) 0.1% (0.2 100%) Accuracy ± 0.5 % (0.2 100%) ± 0.2 % (0.2 5%) Warm-up time 60 s Temperature stabilization after start-up Signal READY Measured gas flow Inlet pressure Maximum allowable pressure - PS Operating temperature Dimensions min. 5 minutes 24V, max. 100mA 0.2 0.3 l / min 1 bar ± 0.1bar 2 bar -10 C 50 C [14 F 122 F] 167 x 130 x 65 mm 2 / 8

This device is designed to detect oxygen concentration levels in gas. The device is designed to be incorporated into the oxygen gas concentrators. This device will be installed in a control cabinet. For this reason, the device does not have a separate box, only a front panel on which buttons, switches and lights are located. The output measurement is in a 4-20mA current loop. The measured gas is fed through a tube into the measuring chamber with the sensor (the sensor and chamber are included). The inlet pressure is about 1 bar, in the measuring chamber pressure is comparable to the atmospheric pressure, the measured gas is then discharged into the atmosphere. The gas flow is about 0.3l/min. Sensor must be used only for clean, dry gases and gas mixtures. Sensor is not suitable for measurements of mixtures containing flammable gases such as H2, CO, CH4, NH3. Sensor is also not suitable for mixtures containing halogen and sulfur compounds, such as F2, Cl2, HCl, HF, SO2, H2S, CS2, Freon. Note: also pay close attention to the silicone seals which are not to be in contact with the measured gas. This will all reduce the life of the sensor. Lifetime The zirconia sensor lifetime should be at least 3 years if it is fully used in accordance with this manual. Also the sensor lifetime is strongly affected should it not be used in specified oxygen concentrations. The sensor is sovered by a 6 moths manufacturer s warranty. Controls: ON ERR1 ERR2 CAL Buttons: DOWN UP START operation signal sensor heater failure measurement error (oxygen concentrations too low or sensor failure) calibration process signalization change of calibration constant change of calibration constant calibration initiation and conrmation Rotary switches: RANGE change of the measuring range, test codes TYPE calibration type setting 3 / 8

GRYF OXY ZM 02/100/2 Measurements can be performed in four predefined measuring ranges. This corresponds to the current output signal 4-20mA. Setting the measurement range is performed by the rotary switch (RANGE) which is located on the front panel. Position 1 example: 4 ma... 0 % 20 ma... 100 % Description of the rotary switch codes RANGE: 1 - range 0.2-100.0% 2 - range 20.9-100.0% 3 - range 0.20-5.00% 4 - range 0.20-2.00% Test codes: 0 - output 0mA 7 - output 10mA 5 - output 4mA 8 - output 16mA 6 - output 8mA 9 - output 20mA 4 / 8

Function: After turning on the power supply, the power supply indicator light (ON) will start flashing at 0.5 sec. intervals. This indicates the warming of the sensor which lasts 60 seconds. When the sensor reaches the correct temperature, the light will stay lit and will turn off each time the oxygen concentration level is being measured. This period lasts about 0.5-20 sec. and is proportional to the oxygen concentration (2-100%). The READY signal indicates measuring readiness. When the device is ready for measuring and the output current is valid, the READY signal value is 24V DC (same value as the supply voltage). Calibration can be performed on pre-selected concentration of oxygen. The type of calibration is selected by the rotary switch (TYPE) located on the front panel. The selected calibration gas must then be entered into the inlet of the meter. Calibration is started by pressing START. After pressing the button, the CALIBRATION indicator light will light up green. After the signal has stabilized, the result can be confirmed by pressing START. After pressing START, the CALIBRATION light will flash green to confirm. Should the CALIBRATION light start flashing red, the calibration has been performed incorrectly or other calibration problems occurred. The calibration constants are out of range. This can be due to attendant error or sensor failure. Calibration example using dry air: connect the dry air to the inlet of the analyzer. The input pressure should be 1bar using the type switch, select position 1. Begin the calibration by pressing the START button. After pressing the button, the CALIBRATION indicator light will light up green. After the signal has stabilized, press START to confirm the result. After pressing START, the CALIBRATION light will flash green to confirm. To obtain the best measuring accuracy, choose a calibration gas with oxygen concentration levels resembling the anticipated measured concentration. Recomended calibration cycle is 6 months. Description of the rotary switch codes TYPE: 0. calibration ban 1. dry air, concentration 20.9% - slope 2. concentration 97% - slope 3. concentration 80% - slope 4. concentration 5% - slope 5. edit slope with buttons Down, Up 6. concentration 0.5% - zero 7. edit zero with buttons Down, Up 5 / 8

1 - +24V 2 - GND 3 - READY 4 - LIN OUT 5 - LIN GND 1 5 1 8 1 LIN OUT 6 READY 7 LIN GND 6 / 8

Purity of inlet gas: In terms of purity, the inlet gas mus not carry particles larger then 10 micrometers. Analyzer installation: This analyzer is not equipped with IP protection and is therefore designed to be installed in a cabinet or case. This analyzer is also recommended to be installed in a vertical position, hose connection on the bottom, terminal plate for power input facing upward. Use the four holes in each corner to install the analyzer to a board or cabinet. Diameter of the holes is 4.3mm. Connect a 4mm hose with the input gas mixture into the INLET line, located on the right side of the front panel. Output gas is diverted via a 4mm hose. The output hose is connected to the OUTLET line, located on the left side of the front panel. If the cabinet or case is well ventilated, it is not necessary to connect a hose to the OUTLET line. To ensure the instrument s correct functioning the output air flow should not be reduced. This is because of balancing the pressure level in the measuring chamber with the ambient air. WARNING!!! The output absolute pressure cannot exceed1.2 bar. The terminal plate for the input voltage and the current loop is located in the upper part of the analyzer. While looking at the back of the analyzer, the following clips are numbered (from left): 1 - +24V 2 - GND 3 - READY 4 - LIN OUT 5 - LIN GND The READY signal and the current loop are jointed, furthermore, they are also accessible on the 8-pin connector with a lock. The pins are also numbered from the left when looking at the back of the analyzer: 1 -LIN OUT 6 - READY 7 - LIN GND The GND and LIN GND signals is connected with a front panel (ground). 7 / 8

Manufacturer of Measuring Instruments