GALISO SOAP OPTION FOR PCT-ADW-D

Similar documents
LCR-6-PT LARGE CYLINDER ROLLER PNEUMATIC WITH TOUCHSCREEN CONTROLLER INSTRUCTION MANUAL MANUAL NUMBER Rev A Issued September 2014

GCI CYLINDER INVERTER

ISB SERIES INTERNAL SHOT BLASTING MACHINES INSTRUCTION MANUAL MANUAL NUMBER

LCR-6-WT-EPP CYLINDER ROLLER EXPLOSION PROOF SERIES INSTRUCTION MANUAL MANUAL NUMBER Rev A Issued November 2011

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Model ASSEMBLY and OPERATING INSTRUCTIONS

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

J Air and Water Kit Instructions Part# 02584

D Series Air and Water Kit Part# 02550

LSA-BAWMBL. Wall-Mounted Boom Arm INSTRUCTIONS

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

92831 TEL: (714) FAX:

ROPV R40 E Series User Manual

CF-SERIES HIGH FLOW REGULATORS

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Ambient Weather TransformaFence User Manual

Parts Manual. Frusheez Machines

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

AIR INLINE METAL SHEAR

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Interface Devices, Inc. Hydraulic Mini Mule

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

92831 TEL: (714) FAX:

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

SC HYDRAULIC ENGINEERING CORPORATION

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

RG3100 and RG3100Ice Regulator System

PERSONAL AIR BREATHING UNIT

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

FLOW CONTROL & AIR PILOT SWITCH VALVES

INSTRUCTION MANUAL GAS TRAK

CSA Sample Draw Aspirator Adapter Operator s Manual

453 Series Steam Heated Vaporizing Regulator

Model Series 62 Constant Differential Relay

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Installation, Operation, and Maintenance Manual

Pressure Injection Cell Operator s Manual

RADROVER REAR RACK INSTALLATION MANUAL

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Sterile Visual Flow Indicator

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

FLANGED TWO-PIECE BALL VALVES

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Gas and Vacuum Tubing Connection Kit for Manual Operation, No

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Yoke Block Instruction Manual

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Multi-Probe Sampling System User Guide & Manual

GAS FRYER Instruction Manual Model #5099NS

FLANGED TWO-PIECE BALL VALVES

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

OPERATOR'S MANUAL GRASS CATCHER GC-4D

AUTOMATED INDUSTRIAL MACHINE, INC TOGGLE-AIRE DIVISION

Index Table. Model 794. Installation, Operating and Maintenance Instructions

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

TactAir PCP Fill Kit/Adapter. Operation Manual

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Gemini Owner s Manual

AUTOMATED INDUSTRIAL MACHINE, INC

Speed control assembly model A-1


Yoke Block Instruction Manual

RAM 4021 Operation Manual

FLANGED MULTI-PORT BALL VALVES

Installation and Operating Manual

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

RG2200 BC Integrated Octopus

Constant Pressure Crude Oil Container Model CPCCP

PCT-ADW-D SERIES AUTOMATIC CYLINDER INVERTER/DRIER INSTRUCTION MANUAL MANUAL NUMBER Issued November 2011

RK-IR Sample Draw Aspirator Adapter Operator s Manual

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

INSTRUCTIONS FOR SINGLE STAGE LECTURE BOTTLE REGULATORS

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

AIR/OVER HYDRAULIC JACK 20 TON

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

Sample Pro Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

GILMONT ACCUCAL FLOWMETERS

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

OPERATOR S MANUAL. Fabric Grass Catcher PART NO PRINTED 1/2011 PRINTED IN USA

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

INSTALLATION & MAINTENANCE INSTRUCTIONS

OPERATOR'S MANUAL. MODEL GC-F4 Fabric Grass Catcher P/N 9055 GRASS CATCHER GC-F4. PART Rev.2 SC301G

Transcription:

GALISO SOAP OPTION FOR PCT-ADW-D Installation and Operation Instructions MANUAL NUMBER 21-11-1008 Issued March 2016 Rev B 09/26/2018 Copyright 2016 - Galiso, Incorporated 22 Ponderosa Ct., Montrose, CO 81401 (970) 249-0233 (800) 854-3789 www.galiso.com

!!!DANGER!!! DO NOT USE THIS EQUIPMENT TO PURGE TOXIC OR FLAMMABLE GAS AND DO NOT USE THIS EQUIPMENT UNDER FLAMMABLE, VOLATILE OR TOXIC ENVIRONMENTAL CONDITIONS

TABLE OF CONTENTS Section/Title Page 1.0 Kit Parts... 1-1 2.0 Installation... 2-1 ILLUSTRATIONS Title Page Soap Option Kit, Parts... 1-1 Item A: Valve and Hex Bushing... 2-1 Item B: Bronze Piston Valve Assembly... 2-1 Item C: Check Valve, Hex Bushing and Tube Fitting... 2-2 Item D: Soap Option Valve... 2-2 Item E: 3/32 O.D. Tubing... 2-3

Read all instructions before attempting to install or operate this machine. GALISO, INCORPORATED IS NOT RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY UNSAFE USE, MAINTENANCE, APPLICATION, MODIFICATION OR IMPROPER INSTALLATION OF THIS MACHINE. Please contact Galiso, Inc.at 1-800-854-3789 for guidance when you are in doubt as to the proper safety precautions to be taken when installing or operating this machine. Receiving and Placement A. Carefully unpack the Soap Option Kit and inspect the items for any damage or missing parts. Report any issues to Galiso, incorporated before installing on the PCT. 1.0 Kit Parts A. Valve and hex Bushing B. Bronze Piston Valve Assembly C. Hex Bushing, Check Valve and Tube Fitting D. Soap Option Valve E. 5/32 O.D. green Tubing (18 Length) F. Soap Probe Item A Clean Air Supply, (Red) ¼ Tubing Item F Soap Probe Assembly ¼ x 5/32 NPT Fitting Valve with Hex Bushing Item B Bronze Piston Valve Assembly ¼ x ¼ NPT Fitting Probe Detergent Out, (Yellow) 5/32 Tubing Item E (Green Tube) Item C Item D Soap Option Valve Check Valve with Hex Bushing and Tube Fitting 21-11-1008 Section 1 1

2.0 Installation A. Install the Valve and Hex Bushing (item A) onto the left side of the PCT enclosure where indicated. Item A B. Install the Bronze Piston Valve Assembly (item B) on the inside of the enclosure. Item B Section 2-1 21-11-1008

1 2 3 4 2.0 Installation, continued C. Remove the plug from the bottom of the Brass Cross and replace with item C (Hex Bushing, Check Valve and Tube Fitting). Item C D. Remove the Valve Stack Cover. Locate the Blank located in slot two and loosen the single Mounting Screw. The Blank should now lift out easily. Replace with the Soap Option Valve (item D). Remove label and the blank. Replace the blank with Item D 21-11-1008 Section 2 2

2.0 Installation, continued E. Remove the 5/32 plug from the Valve Stack Port for slot two. Insert the free end of the 5/32 O.D. green tube (item E) into this Port. Remove the T plug and insert Item E. F. Fill the Cylinder with a suitable, oxygen compatible detergent or cleaning solution. The level of the detergent should be 6 below the bottom of the threads in the Cylinder Neck. Use an oxygen compatible, liquid degreaser, water soluble soap such as SD-13. SD-13 is available from Galiso, Incorporated at (800) 854-3789 or visit the website at www.galiso.com. NOTE: Certain types of detergents and cylinder cleaning solutions are not compatible with aluminum cylinders. Galiso, Inc. recommends using a steel cylinder as the Detergent Reservoir. Put Teflon tape around the threads on the Probe and screw into the neck of the Detergent Reservoir Cylinder. G. Install the Soap Probe (item F) into a clean, low pressure Cylinder with a ¾ NPT neck opening. The bottom of the Dip Tube may need to be trimmed prior to installation. The length of the Dip Tube should allow approximately 3 between the end of the Dip tube and the bottom of the cylinder (after fully installed in the Cylinder Neck). Section 2-3 21-11-1008

2.0 Installation, continued H. Fill the Cylinder with a suitable, oxygen compatible detergent or cleaning solution. The level of the detergent should be 6 below the bottom of the threads in the Cylinder Neck. Use an oxygen compatible, liquid degreaser, water soluble soap such as SD-13. SD-13 is available from Galiso, Incorporated at (800) 854-3789 or visit the website at www.galiso.com. I. Put Teflon tape around the threads on the Probe and screw into the neck of the Detergent Reservoir Cylinder. J. Make certain the Soap/Water Control Valve and the Air In Control Valve, on the probe, are in the closed position. K. Connect the Clean Air In Tubing (Red) on the Probe to a clean, filtered air source. This air source should have a contaminant level less than 0.03 parts per million. The Detergent Reservoir Clean Air Supply Line can originate from the clean air source supplying the PCT. A filter system is available from Galiso, Inc. which will clean the air to a contaminant level of 0.01 parts per million. The Detergent Reservoir Clean Air Supply Line should be equipped with a regulator, set at 80 psi. L. Connect the Detergent Out Supply Line (Yellow) on the Probe, to the Detergent In Port on the side of the PCT Shroud. M. Open the Air In Control Valve and allow the Detergent Reservoir to build pressure. Open the Soap/Water Control Valve on the Probe. NOTE: It may be necessary to adjust the amount of detergent flow for the size of cylinders that are being serviced. If the cylinders are consistently dirty after cleaning, open the Soap/Water Control Valve slightly. If a detergent residue remains after rinsing, slightly close the Soap/Water Control Valve. N. With the power to the PCT turned on and a Cylinder loaded into the Clamp Arms, select Manual Mode (F5), then Clamp (F1), and then Invert (F4). 21-11-1008 Section 2 4

2.0 Installation, continued O. After the Cylinder has been inverted, the following menu will show: P. Press Soap (or F2) to begin the Soap (Detergent/Water mix) spray into the Cylinder. When in Manual Mode, each selection is a toggle switch either ON or OFF. Press Soap or F2 to turn on and off the Soap Injection. NOTE: At any point when SOAP is selected, a combination of both detergent and hot water will be injected. Only the word SOAP is displayed. Q. Proceed with standard PCT operations, referring to instruction manual 21-11- 1009 for digital versions or 21-11-1007 for older units with a keypad. Section 2-5 21-11-1008

PRODUCT WARRANTY 1. DURATION: Galiso provides a one-year warranty from date of purchase, to the original purchaser, for standard products, unless otherwise specified. For all spare parts purchases, Galiso provides a 90-day warranty unless otherwise specified. Soft goods such as our speed seals, and O-rings, which are subject to wear in the normal course of operation, are not covered under this warranty. 2. COVERAGE: Galiso manufactured equipment is warranted against defective materials or workmanship. THIS WARRANTY IS VOID IF: A) THE EQUIPMENT HAS BEEN DAMAGED BY ACCIDENT OR UNREASONABLE USE, IMPROPER SERVICE/MAINTENANCE, IMPROPER INSTALLATION, ABNORMAL OPERATING CONDITIONS, NEGLECT, REPAIR BY ANY PERSON NOT AUTHORIZED BY GALISO, INC. OR OTHER CAUSES NOT RELATED TO MATERIAL DEFECTS OR WORKMANSHIP. B) THE SERIAL NUMBER HAS BEEN ALTERED OR DEFACED. 3. PERFORMANCE: Galiso reserves the right to make warranty determination only after inspecting the item at the Galiso manufacturing facility. If the warranty determination indicates that the defective item is covered under warranty, the item will be repaired or replaced with the same parts/items or parts/items of equivalent quality, at the option of Galiso. In the event of replacements, the replacement unit will continue under the original equipment warranty or carry a 90-day warranty, whichever is longer. No charge will be made for warranty repairs, and/or replacements. All freight charges to and from Galiso Inc. or a Galiso Inc. authorized repair facility, are the responsibility of the customer requesting warranty service. If the warranty determination indicates that the item is not covered by warranty, a repair/replacement cost estimate will be submitted to the customer/purchaser for approval prior to initiating any repair work. 4. CLAIMS: In the case of equipment malfunction, notify Galiso (1-800-854-3789) and provide the Model Name, Model Number, Serial Number and a description of the problem. Return Authorization Number, shipping and/or service information will be provided on receipt of the required information. 5. SERVICE EQUIPMENT: Galiso attempts to make available, whenever possible, a limited amount of service equipment at a minimal use charge, plus freight expense, for those customers wishing to avoid downtime during repair of their equipment. Such items are available on a first come, first served basis and are billable at the specific service charge applying with a one-month minimum. 6. MODEL CHANGES: Galiso reserves the right to make changes in materials and specifications, without notice. Galiso may offer, for a stipulated fee, the opportunity to upgrade your equipment to the latest configuration. 7. DISCLAIMERS: Galiso provides technical data and assistance to aid customers in the selection and use of our products. There are no implied warranties of merchantability nor suitability for a particular purpose associated with the transmittal of technical data and/or customer assistance. Galiso does not assume liability for any consequential, incidental, or special damages. Liability under this warranty is limited to repairing, or replacing Galiso equipment items returned to the factory or an authorized facility. 8. COMPUTER AND NETWORK VIRUS PROTECTION: Galiso Inc. equipment, which utilizes internet access, comes equipped with a subscription to virus protection software. It is the responsibility of the equipment owner to maintain this virus protection subscription or other virus protection at their cost. Current virus subscriptions are mandatory to maintain the benefits of this warranty. Galiso does not assume liability for any or all damages related to or are the result of internet or network failure or malware or computer viruses or any other type of internet or network malfunction or attack. GSO9102-1E 05/31/12 Supersedes: 01/07/02