Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

Similar documents
Directional Control Valves

Directional Control Valves

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

1 0,1 0,1-70 0, , , , Cylinder bore <

Pressure regulators Manually operated Fine setting valves. Brochure

Panel-mounted valves Series T, Ø 22.5 mm

Valves, manually operated

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

Valves, manually operated

Hand lever valves VHER

Wide opening parallel grippers Series CGLN

Series MX pressure regulators 3/

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

4/2 way Pneumatic Solenoid Valve

safety Shut-Off Valve HON 721

SPECIAL PURPOSE DIRECTIONAL AND PRESSURE CONTROL AIR VALVES MOBILE, OILFIELD AND MARINE

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series

Pneumatic valve islands

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Type 4708 Supply Pressure Regulator

Bores: ø 10, 16, 20, 25, 32 mm

Proportional pressure regulators VPPE

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Pressure Sensing Valve - Model 4023

Precision pressure regulators LRP/LRPS

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Precision and Instrument Regulators 1/4" port size

Type 4708 Supply Pressure Regulator

Flow control valves Series RFU - RFO 2/

Precision Pressure Regulators

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Bike holder with three-point-support for mounting stand

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Hydraulic Punch Drivers

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

zkratka označení: PAL* technický list výrobku vytvořeno :13 1/6 pneumatický pohon série RE > tvrdý anodizovaný hliník NBR

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Heavy Metal Stainless Steel Valves

Two-port valves, male threaded, PN25

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Type 4708 Supply Pressure Regulator

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

180 Series Rotary Shear Directional Control Valve

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Series V47 Temperature Actuated Modulating Valves

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Pilot Check Valve: Metal Body Type

Pneumatic Grippers Swivel Modules

shutoff valves 900 Series psig Manual Shutoff Valves

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

2-port seat valves PN25 with externally threaded connections

Cylinder Controls. Operating information. For ATEX specific products contact Sales Office. 2/2 Blockers. PDE2600PNUK Parker Pneumatic

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:

Installation, operation & maintenance manual - original version

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

ATM 322 Basic Pneumatics H.W.6 Modules 5 7

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

ALF400 to 900, ALT-5/-9

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

64 Series Pressure Reducing Regulators

HEAVY DUTY KNIFE GATE VALVE

OP11 OVERALL SPECIFICATIONS

Basic Pneumatics. Module 7: Time delay valve and sequence control systems. Academic Services PREPARED BY. January 2013

AVP-F. p setting range (bar) Code No. 003H6200

Dival 600. Pressure Regulators

Technical information for hinges

DICTATOR "DIREKT" Gate Closer

Norval Pressure Regulators

3-Way Safety Block DSV

Hydraulic Punch Drivers

TECHNICAL DATA OBSOLETE

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

Series CGZT three-jaw grippers with T-guide

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

TECHNICAL DATA. Q = C v P S

HERZ-Motorised flow controler

Technical Information Cleanfit CUA451

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4

Pneumatic spool valve islands

Pressure balanced valves (PN 25)

EXH. Specifications. Descriptions. Min. working pressure MPa

CROSS REFERENCE PARTS LIST T & S

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C

VACUUM REGULATORS CONTENTS

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

Air-service devices, Series MU1

Direct Operated Precision Regulator Modular Style. Standard Specifications

B74G - EXCELON Modular System General purpose filter/regulator

R84G - Excelon Plus Modular System Pressure regulators

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

Transcription:

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8 Catalogue 9127003472GB-ul

VA13 and VA15 Directional Control Valves Robust 3- and 5-port valves with brass bodies and stainless steel O-ring sealed spools. Substantial actuating levers and knobs which can be operated by gloved hands. Pneumatically, manually, foot or mechanically actuated valves in a wide choice types. Suitable for panel mounting or direct mounting via integral mounting holes. Most of the VA13 valves can be connected either as normally closed or normally open as required, by connecting the primary air supply to Port 1 or Port 3. VA13 and VA15 3- and 5-port valves, size G1/8 The VA13/15 valve range consists of spool valves of extremely robust design, incorporating a wide range of manual, mechanical and pilot-operated actuators. The robust design, coupled with good corrosion resistance, makes the valves suitable for a wide range of applications. Manually operated valves are suitable for industrial and transport applications. The stable and ergonomically designed actuators make the valves easy to operate even with heavy working gloves. The valve bodies and caps are made of brass. Stainless steel is used in the spools and the mechanical actuating devices. Versions intended for panel mounting have chromium-plated steel actuators and panel bezels. Ordering example VA13-HIS4 Valve type, VA Valve size 1 = G1/8 Number of ports, 3 or 5 Supplementary code X = 5/3 valve with exhausted centre position Type of actuation Type of return Type of installation 4 = panel mounted Products specially suitable for the transport industry. 2

VA13 and VA15 Directional Control Valves Installation Correctly mounted valves require only a minimum of maintenance. For maximum life, follow the instructions with regard to actuation directions, actuation speeds, angles and adjustments. Panel mounting Mount the valves in a 40,5 mm diameter hole (thread M40 x 1,5). The panel-mounting collars have a flange on the front of the panel and a retaining nut behind the panel, for simple installation and clean and attractive appearance. W UW Fitting adjustable roller actuators The rest position of the actuating arm can be arranged at any required angle on the actuator shaft (360 ). The length of the arm is adjustable, and it can also be rotated through 180. Note, however, that the roller must always be parallel to the valve body. The arm can also be positioned on the other side of the valve by removing the actuating mechanism, turning it through 180 and reassembling it. Actuation Maximum actuation distance (X), i.e. the maximum spool stroke lenght, is 4 mm. Valves are fully open after 3,5 mm travel. Type UW toggle cam actuators permit a vertical motion in toggle direction of up to 10 mm. WG Actuation by adjustable roller Actuation can be arranged in both directions if the arm is set as shown above. The arm needs to be moved through only 5 to make the valve change over, although a travel range of up to 90 can be accepted. α, β Actuation speed as a function of actuation angle Optimum valve life will be obtained if the shape of actuation cams is matched to the method of actuation employed. The principle is that the higher the speed of the actuating motion, the smaller the incident angle. The characteristic curve shown here plots the incident angle against speed of the actuating stroke. Material specifications Valve bodys, end covers, spring guides Brass Spools Polished stainless steel Seals Nitrile rubber Screws, nuts, washers Zinc plated steel Balls Steel Push-buttons, knobs Acetal plastic Levers Chrome-plated steel Pedals Phosphatized cast-iron I-plunger Hardened stainless steel Rollers Acetal plastic IMPORTANT Before servicing, make sure that the valve is depressurised. Disconnect the primary air hose to ensure that the air supply is safely interrupted before removing valves. 3

VA13 Hand actuated Data Working temperature: -20 C to +70 C Working pressure: max 10 bar Flow (acc. to ISO 6358) C: 0,9 Nl/s, bar Qn (P1=6 bar, p=1 bar): 3,6 l/s Qmax: 6,3 l/s Cv: 0,21 Dimensions see page 10 Symbol Actuator Return Mounting Changeover Weight Order code force at 6 bar kg Push-button Spring Panel mounted 32,5 N 0,37 VA13-HIS4 Push-button Spring Panel mounted 32,5 N 0,37 VA13-HIS4A06* Black Push-button Air signal Panel mounted 6 N** 0,37 VA13-HIA4 Hand lever Hand lever Panel mounted 8 N 0,52 VA13-HB24 Held in two positions Side mounted 8 N 0,35 VA13-HB2 Knob Knob Panel mounted 3 N 0,48 VA13-KL24 Two positions Side mounted 3 N 0,31 VA13-KL2 Knob Spring Panel mounted 31,5 N 0,49 VA13-KS4 Side mounted 31,5 N 0,32 VA13-KS Knob Knob/ Panel mounted 6 N** 0,49 VA13-KL2A4 Air signal Two positions Side mounted 6 N** 0,33 VA13-KL2A * Panel holder in black anodized aluminium. ** Without signal pressure. Signal pressure min 3 bar at 6 bar supply pressure. Accessories for VA13/15HI... series valve Description Weight Order code kg Diaphragm Mounting ring Diaphragm, black 0,01 9127 3593-31 Diaphragm, yellow 0,01 9127 3593-32 Mounting ring 0,02 9127 3593-34 All VA13 valves (except VA13-WGR and VA13- RWG) can be connected either as normally closed 3/2 valve (NC) or normally open 3/2 valve (NO) as required, by connecting the primary air supply to Port 1 or Port 3. 4

VA15 Data Working temperature: -20 C to +70 C Working pressure: max 10 bar Flow (acc. to ISO 6358) C: 0,9 Nl/s, bar Qn (P1=6 bar, p=1 bar): 3,6 l/s Qmax: 6,3 l/s Cv: 0,21 Hand actuated Dimensions see page 11 Symbol Actuator Return Mounting Changeover Weight Order code force at 6 bar kg Push-button Spring Panel mounted 34,5 N 0,46 VA15-HIS4 Hand lever Hand lever Panel mounted 9 N 0,63 VA15-HB24 Held in two positions Side mounted 9 N 0,45 VA15-HB2 Hand lever Hand lever Panel mounted 9 N 0,63 VA15-HB34 Held in three positions Closed centre position Hand lever Hand lever Panel mounted 9 N 0,63 VA15-XHB34 Held in three positions Exhausted centre position Hand lever Hand lever Panel mounted 9 N 0,63 VA15-HC4 Three positions Closed centre self-centring position Hand lever Hand lever Panel mounted 9 N 0,63 VA15-XHC4 Three positions Exhausted centre self-centring position Knob Knob Panel mounted 5 N 0,58 VA15-KL24 Two positions Side mounted 5 N 0,42 VA15-KL2 Knob Spring Panel mounted 34,5 N 0,60 VA15-KS4 Knob Knob/Air signal Panel mounted 8 N* 0,61 VA15-KL2A4 Two positions *Without signal pressure. Signal pressure min 3 bar at 6 bar supply pressure. 5

VA13, VA15 Foot actuated Data Working temperature: -20 C to +70 C Working pressure: max 10 bar Flow (acc. to ISO 6358) C: 0,9 Nl/s, bar Qn (P1=6 bar, p=1 bar): 3,6 l/s Qmax: 6,3 l/s Cv: 0,21 VA13 Dimensions see page 12 Symbol Actuator Return Mounting Changeover Weight Order code force at 6 bar kg Pedal Spring Foot mounted 23,5 N 1,14 VA13-FS All VA13 valves (except VA13-WGR and VA13- RWG) can be connected either as normally closed 3/2 valve (NC) or normally open 3/2 valve (NO) as required, by connecting the primary air supply to Port 1 or Port 3. VA15 Dimensions see page 12 Symbol Actuator Return Mounting Changeover Weight Order code force at 6 bar kg Pedal Spring Foot mounted 24,5 N 1,25 VA15-FS 6

VA13, VA15 Pneumatically actuated Data Working temperature: -20 C to +70 C Working pressure: max 10 bar Flow (acc. to ISO 6358) C: 0,9 Nl/s, bar Qn (P1=6 bar, p=1 bar): 3,6 l/s Qmax: 6,3 l/s Cv: 0,21 VA13 Dimensions see page 13 Symbol Actuator Return Mounting Signal Weight Order code pressure Kg min, bar at 6 bar actu./return Air signal Air signal Side mounted 3/3 0,33 VA13-AA Air signal Spring Side mounted 4/- 0,32 VA13-AS Air signal Air signal Side mounted 3/4 0,32 VA13-ADA with priority VA15 Dimensions see page 13 Symbol Actuator Return Mounting Signal Weight Order code pressure Kg min, bar at 6 bar actu./return Air signal Air signal Side mounted 3/3 0,33 VA15-AA Air signal Spring Side mounted 4/- 0,32 VA15-AS Air signal Air signal Side mounted 3/4 0,32 VA15-ADA with priority 7

VA13 Mechanically actuated Data Working temperature: -20 C to +70 C Working pressure: max 10 bar max 8 bar for WGR and RWG Flow (acc. to ISO 6358) C: 0,9 Nl/s, bar Qn (P1=6 bar, p=1 bar): 3,6 l/s Qmax: 6,3 l/s Cv: 0,21 Dimensions see page 14 Symbol Actuator Return Mounting Changeover Weight Order code force at 6 bar kg Plunger Spring Side mounted 32,5 N 0,30 VA13-IS Plunger Plunger Side mounted 3 N 0,30 VA13-II Two positions Plunger Air signal Side mounted 6 N* 0,30 VA13-IA Roller Spring Side mounted 20,5 N 0,33 VA13-UWS one way trip Roller Spring Side mounted 32,5 N 0,33 VA13-WS Roller Internal air Side mounted 0,6 N 0,41 VA13-WGR on an arm min 4 bar Normally closed min Roller Internal air Side mounted 0,6 N 0,41 VA13-RWG on an arm min 4 bar Normally open min * Without signal pressure. Signal pressure min 3 bar at 6 bar supply pressure. All VA13 valves (except VA13-WGR and VA13- RWG) can be connected either as normally closed 3/2 valve (NC) or normally open 3/2 valve (NO) as required, by connecting the primary air supply to Port 1 or Port 3. 8

VA15 Mechanically actuated Data Working temperature: -20 C to +70 C Working pressure: max 10 bar max 8 bar for WGR Flow (acc. to ISO 6358) C: 0,9 Nl/s, bar Qn (P1=6 bar, p=1 bar): 3,6 l/s Qmax: 6,3 l/s Cv: 0,21 Dimensions see page 15 Symbol Actuator Return Mounting Changeover Weight Order code force at 6 bar kg Plunger Spring Side mounted 34,5 N 0,40 VA15-IS Plunger Plunger Side mounted 5 N 0,40 VA15-II Two positions Roller Spring Side mounted 21,6 N 0,43 VA15-UWS one way trip Roller Spring Side mounted 34,5 N 0,44 VA15-WS Roller Internal air Side mounted 0,6 N 0,46 VA15-WGR on an arm min 4 bar min 9

VA13 Hand actuated Dimensions KL24 HB24 10

VA15 Hand actuated Dimensions KL24 HB24 VA15- VA15-X 11

VA13, VA15 Foot actuated Dimensions VA13-FS VA15-FS 5 12

VA13, VA15 Pneumatically actuated Dimensions A S A AD 22 20* Ø20 Ø18* 32 * Dimension on A-end at AD actuation A S A AD 22 20* Ø20 Ø18* 32 * Dimension on A-end at AD actuation 13

VA13 Mechanically actuated Dimensions 14

VA15 Mechanically actuated Dimensions 15