Fluke Europe B.V. P.O. Box BD Eindhoven The Netherlands

Similar documents
P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

GBK-50M / GBK-110M. Booster. Instructions. Introduction. How to Contact Fluke Calibration

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

CSA Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Pressure Injection Cell Operator s Manual

Pressure Dump Valve Service Kit for Series 3000 Units

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Pressure Dump Valve Service Kit for Series 2300 Units

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

TactAir PCP Fill Kit/Adapter. Operation Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

J Air and Water Kit Instructions Part# 02584

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

D Series Air and Water Kit Part# 02550

KJ4000 Operating Instructions & Parts Manual NSN

Pressure Automated Calibration Equipment

Freedom8 ShoeBox Compressor Manual

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Speed control assembly model A-1

BS Series Basket Strainer

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

FLANGED TWO-PIECE BALL VALVES

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

DPC-30 DPC-100. Reference Manual

Yoke Block Instruction Manual

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

VLI Visible Level Interface Operation & Maintenance Manual

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

453 Series Steam Heated Vaporizing Regulator

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

MPG2-H and MPG2-H-HV Manual Pressure Generator/Controller for Hydraulic Pressure Operation and Maintenance Manual

Operation Manual Piston Sensed Gas Pressure Regulators

CP10 Sensor Installation and Maintenance Instructions

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

LRS(H)4 Pressure-Reducing Regulator User Manual

Yoke Block Instruction Manual

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

1 DRIVE INDUSTRIAL IMPACT WRENCH

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Pressure Relief Valve Instruction Manual

Contents. Overview Setup Safety Instructions Operating Instructions Connection Diagram Specifications...

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Techcon Systems TS1254 Pressure Pot

GILMONT ACCUCAL FLOWMETERS

BCV31 DN40 - Blowdown Control Valve

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

MPC1-D-1000/MPC1-D-3000 Manual Pressure Controller for Differential Pressure User s Manual

P3800 Series. Users Manual. High Pressure Hydraulic Deadweight Tester

Geotech 1.66 Auto-Reclaimer Installation and Operation

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

RGC-IR Remote Gas Calibrator for IR400

100C Air Compressor Kit

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

2K 600mL Dispense Guns with Built-In Retainers

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

FLANGED TWO-PIECE BALL VALVES

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Techcon Systems TS1258 Pressure Pot

Model ASSEMBLY and OPERATING INSTRUCTIONS

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

RG2200 BC Integrated Octopus

PV4 and PV6 Piston Valves

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Geotech 1.66 Auto-Reclaimer

200 PSI COMPRESSORS - MODEL NUMBERS

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

IMPORTANT SAFETY INSTRUCTIONS

64 Series Pressure Reducing Regulators

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

G96 Series BASOTROL Dual Operator Valve

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

WEATHERIZING INSTRUCTIONS

Transcription:

CPS-40M-HC40 Contamination Prevention System CPS-100M Introduction The Fluke CPS-40M-HC40 (CPS-40M) Contamination Prevention System and CPS-100M High-Pressure Contamination Prevention System (Product) are accessories that protect pressure controllers from contamination by the Device Under Test (DUT). CPS-40M-HC40 (CPS-40M) has a maximum-working pressure of 44 MPa (6400 psi). CPS-100M has a maximum-working pressure of 110 MPa (16 000 psi). When the CPS is enabled, the pressure controller controls the CPS valves to decrease the test system pressure, purge contaminants, and completely vent the test system. The Product is connected to the pressure controller by a high pressure hose and a control cable. There is an optional vacuum pump connection (CPS-40M only). All upward pressure changes are accomplished by the pressure controller. Rough downward changes in pressure are accomplished through the Product's vent valve. This results in most of the gas being exhausted out of the Product instead of going back to the controller. Contaminants from the DUT are filtered and liquids drop into a sump. The sump is automatically purged into a waste bottle when the system is vented. The product includes both mesh and coalescing filters that are replaceable. PN 5007263 July 2018 2018 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Specifications are subject to change without notice. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands ООО «Флюк СИАЙЭС» 125167, г. Москва, Ленинградский проспект дом 37, корпус 9, подъезд 4, 1 этаж 1

CPS-40M-HC40/CPS-100M How to Contact Fluke Calibration To contact Fluke Calibration, call one of the following telephone numbers: Technical Support USA: 1-877-355-3225 Calibration/Repair USA: 1-877-355-3225 Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31-40-2675-200 Japan: +81-3-6714-3114 Singapore: +65-6799-5566 China: +86-400-810-3435 Brazil: +55-11-3759-7600 Anywhere in the world: +1-425-446-6110 To see product information and download the latest manual supplements, visit Fluke Calibration s website at www.flukecal.com. To register your product, visit http://flukecal.com/register-product. Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. WWarning To prevent personal injury: Read all safety information before you use the Product. Wear eye protection. Do not use with flammable or combustible liquids. Use the Product only as specified, or the protection supplied by the Product can be compromised. Carefully read all instructions. Do not use the Product if it operates incorrectly. Do not use the product if it is altered or damaged. Disable the Product if it is damaged. Do not attempt to operate the Product above its rated pressure. Do not disconnect tubing when the system is pressurized. W Caution To avoid damage to the Product, carefully follow the cleaning and decontamination instructions in the manual. Do not use unapproved solvents or cleaners on the Product. 2

Symbols The symbols shown in Table 1 are found in these instructions or on the Product. Table 1. Symbols Contamination Prevention System Symbols Symbol W WARNING, RISK OF DANGER. Consult user documentation. Definition ) Certified by CSA Group to North American safety standards. P Conforms to European Union directives. Conforms to relevant Australian Safety and EMC standards. This product complies with WEEE Directive marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE directive Annex I, this product is classed as category 9 Monitoring and Control Instrumentation product. Do not dispose of this product as unsorted municipal waste. Box Contents The Product is either of these kits: CPS-40M: CPS-40M-HC40 Test Station Pressure Hose, JIC #4 (AN4) fittings Pressure Hose Adapter Fittings, JIC #4 (AN4): 1/4 NPT; 1/4 BSP; 7/16-20 (x2) Vacuum Hose, 3/8 inch polyethylene Vacuum Hose Adapter Fittings, 3/8 tube: 1/4 NPT; 1/4 BSP; 7/16-20 (x2) PK-ADPTR-HC40 Adapter Set CPS Cable CPS-100M: CPS-100M Test System High-Pressure Hose, DH500 Fittings (cone and threaded connection compatible with Autoclave F250C and HIP HF4) CPS Cable 3

CPS-40M-HC40/CPS-100M Features The CPS-40M features are shown in Table 2. The CPS-100M features are shown in Table 3. Table 2. CPS-40M 3 4 5 6 2 10 1 7 8 9 ifc01.eps Number Description D E F G H I J Stand Pressure Hose Tee Vacuum Hose TEST port connector LED Indicator Drain Tube Filter Cover Filter Housing Body 4

Table 3. CPS-100M Contamination Prevention System Features 2 3 4 1 5 6 7 8 ifc02.eps Number D E F G H Stand High-pressure Hose DUT Port LED Indicator Body Drain Tube Filter Cover Filter Housing Description 5

CPS-40M-HC40/CPS-100M Set Up This section details Product set up. W Warning To prevent personal injury, use thread sealing tape only on NPT fittings to avoid incorrect sealing. Do not use on JIC #4 (AN4), BSP, SAE or DH500 fittings. CPS-40M-HC40 For atmospheric calibration: 1. Ensure the O-ring is on the SAE side of a SAE to JIC #4 (AN4) adapter. 2. Install the above adapter to the CONTROLLER port of the CPS. 3. Install the applicable adapter (JIC #4 (AN4) to NPT, BSP or SAE) to the TEST port of the pressure controller. 4. Connect the pressure hose to the two adapters and tighten with a wrench. 5. Attach the CPS cable to the connector on the rear panel of the CPS, plug the other end into the solenoid driver connector on the rear-panel of the pressure controller. 6. Install the free end of the drain tube into a suitable container to collect fluid contaminants. For sub-atmospheric calibration: 1. Ensure O-ring is on the SAE side of a SAE to 3/8 tube adapter. 2. Install the above adapter to the VAC port of the CPS and tighten with a wrench. 3. Install the applicable adapter (3/8 tube to NPT, BSP or SAE) to the EXHAUST port of the pressure controller and tighten with a wrench. 4. Place the CPS in desired location noting that test gauges will likely be mounted on top of it. 5. Plan the cuts on the 3 needed vacuum tubing sections; vacuum pump to tee, tee to CPS, and tee to pressure controller. See Table 2. Cut the vacuum tubing into these three pieces. 6. Connect the vacuum tubing to the tee and adapters (to vacuum pump, VAC port on CPS, and EXHAUST port on pressure controller) by normal nut and ferrule tube connection methods. CPS-100M To set up the CPS-100M: 1. Slide the gland nut over the threaded center of the hose end fitting as shown in Figure 1. 2. Screw the collar onto the left-hand thread hose end fitting, counter-clockwise. 3. Repeat steps 1 and 2 for the other hose end. 4. Install the High-Pressure Hose from the CONTROLLER port on the CPS to the TEST port on the pressure controller. Torque to 15 N m (11 lbf ft) with a wrench. Excessive torque will lead to premature leaks that will require replacement of the fitting. 5. Attach the CPS cable to the connector on the rear panel of the CPS, plug the other end into the solenoid driver connector on the rear panel of the pressure controller. 6. Install the free end of the drain tube into a suitable container to collect fluid contaminants. 6

Contamination Prevention System Operation - DUT Connection A B C ife004,eos Figure 1. W Caution To prevent Product damage, before you use the CPS-100M, enable the CPS on the pressure controller (SETUP>Instrument Setup External Values>CPS) refer to controller operators manual. The CPS must be enabled or the controller could be exposed to contamination. When enabled, the LED illuminates. Operation - DUT Connection W Caution To prevent Product damage or damage to a gauge: To prevent incorrect sealing that creates an unsafe condition, do not use threadsealing tape or any other sealing method on the DUT or the adapters. The Gauge Adapter sealing system can be hand-tight sealed up to 44 MPa (6400 psi). Wrenches or similar tools are not required. Over tightening can cause damage to threads or sealing faces. Before connection, ensure that there are O-rings fitted to the test port and gauge adapter. Check that the sealing face of the device to be fitted is clean and undamaged, as scratches or dents can form leak-paths. Any DUT that is known to be full of liquid, or grossly contaminated, should be cleaned before using with a CPS and pressure controller. Also use the CPS Purge and CPS Cleanout Tasks to perform a final clean of the DUT before calibration. 7

CPS-40M-HC40/CPS-100M CPS-40M-HC40 1. Select the appropriate adapter from the adapter set to match the thread on the DUT. 2. Screw the adapter fully onto the DUT so that the bottom face of the DUT seals on the O-ring inside the adapter. Hand-tight is sufficient. 3. Turn the adapter collar counter-clockwise until the adapter seals on the O-ring in the mounting post to mount the DUT/adapter assembly to the test port. Hand-tight is sufficient. 4. To adjust the position of the DUT, hold the adapter, and turn the collar clockwise 1/4-turn. 5. Position the DUT to face the desired direction, and turn the collar counter-clockwise to re-seal. CPS-100M The DUT mounts directly to the test port on the CPS-100M, with a metal-to-metal DH500 connection. Torque to 15 N m (11 lbf ft) with a wrench. 1. To adjust the position of the DUT, unscrew the gland nut counter-clockwise 1/4-turn. 2. Position the DUT to face the desired direction, and tighten the gland nut clockwise re-seal. Operation - CPS Tasks Purge Tasks are accessed by the Setup>Tasks menu path on the controller s display screen. Purge is used to void the test system connected to the CPS of liquid or particulate contaminants by pressurizing and venting the test system plumbing through the CPS (same as normal operation). Fluke Calibration recommends to do this before a calibration is performed if gross contaminants might be present. To purge the system, the Product pressurizes to the user-defined purge pressure and then vents to the drain tube. The controller repeats the process for the number of cycles that are set. To run a purge process: 1. Select the Purge Task to enter the menu. 2. Set the Pressure, 350 kpa (50 psi) for example, but not higher than the rating of the DUT. 3. Set the number of cycles. 4. Select Run to start the purge process. Figures 2 and 3 show the normal operaton and the Purge function of both models in a cross-section. 8

Contamination Prevention System Purge Figure 2. Cutaway of the CPS-40M-HC40 during a Normal Downward Pressure Excursion, or Purge Task Ifc06.eps ifc15.eps Figure 3. Cutaway of the CPS-100M Purge Task during a Normal Downward Pressure Excursion, or Purge Task 9

CPS-40M-HC40/CPS-100M CPS Cleanout CPS Cleanout is a function that pushes contaminants from the sump of the CPS out the drain tube. A lowpressure setpoint is automatically set to establish a flow to clean out the CPS for the specified amount of time. This same function occurs each time the CPS is controlling downward or venting with the pressure less than 170 kpa (25 psi). Disconnect the Product To disconnect the Product, ensure that the system is vented and then disable the CPS in the controller settings. Make sure that the CPS is disabled in the firmware if it is physically disconnected from the controller. Failure to do so could result in the controller not being able to vent pressure. Once disabled in the firmware, the CPS can be disconnected both electrically and pneumatically. Do not leave the CPS physically connected to the controller if it has been disabled in the firmware. Maintenance Inspect the drain tube and waste bottle/container after use. If the drain tube or liquid from the tube shows signs of contamination (particulates or oily substances), the coalescing filter and mesh filter should be inspected. The frequency of inspection will vary depending on the condition of Devices Under Test (DUT) that have been calibrated. With time and experience, you can determine if a regular inspection interval is more appropriate, or if the filters should be inspected when the waste bottle/container is full. Push on the plastic ring on fitting to disconnect drain tube, and pull gently on the drain tube. See Figure 2. 2 3 1 ifc03.eps Figure 2. 10

Contamination Prevention System Maintenance 1. Unscrew the filter cover counter-clockwise to release the coalescing filter D and O-ring (see Table 4) E. See Figure 3. 5 4 3 Figure 3. ifc05.eps 2. Unscrew filter housing F counter-clockwise to release mesh filter H, spring I and O-ring (see Table 4) G. See Figure 4. 11

CPS-40M-HC40/CPS-100M 9 8 7 6 ifc04.eps Figure 4. The coalescing filter D cannot be cleaned, and should be replaced when heavily discolored or showing signs of deterioration (see Table 4). 3. Clean the mesh filter H with suitable solvent and replace if necessary (see Table 4). 4. Clean interior chambers of filter housing F to remove any contaminant particles or residue. 5. Fit the O-ring, mesh filter, and spring to housing and screw clockwise into the main body. 6. Fit coalescing filter and the O-ring to the filter cover and screw clockwise into the filter housing. Replacement Parts Replacement parts are listed in Table 4. Table 4. Replacement Parts Number (See Figures 3 and 4) Description Part Number D Coalescing Filter 4578779 E O-ring (above coalescing filter) 4840807 G O-ring (below mesh filter) 3922019 H Mesh Filter 4976723 12

Specifications Contamination Prevention System Specifications Operating Temperature... -20 C to +50 C Storage Temperature... -20 C to +70 C Operating Humidity... 5 % to 95 % relative humidity, non-condensing Wetted Materials... Stainless Steel, Aluminum, Nitrile, PTFE, borosilicate glass CPS-40M-HC40 Pressure Range... -0.1 MPa to 44 MPa (-15 to 6400 psi) Weight... 3900 g (8.0 lb) Dimensions... 175 mm x 185 mm x 300 mm (6.9 in x 7.3 in x 11.8 in) CPS-100M Pressure Range... 0 MPa to 110 MPa (16 000 psi) Weight... 3630 g (8.6 lb) Dimensions... 175 mm x 185 mm x 270 mm (6.9 in x 7.3 in x 10.7 in) Safety General... IEC 61010-1; Pollution Degree 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. 11/99 13