DREXELBROOK A Leader In Level Measurement Solutions

Similar documents
Model 575 and 575P Submersible Level Transmitters. Model 675 Submersible Level Transmitters. Model SDT Submersible Level Transmitters

Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch

RCD - Ultra-Rugged Differential Pressure Flowmeter

Autocalibration Systems For In Situ Oxygen Analyzers

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

analytical bulk flow distance FLOW level pressure temperature industrial communication

Over 20,000 Strain Gage Target flowmeters installed since 1952.

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

Torque Tube TB300 Digital Transmitters

660 Multipoint Electronic Level Switch

High-performance submersible pressure transmitter For level measurement Model LH-10

Dynisco SPX Industrial (2280/2281) Series

780S Ultra High Purity Series

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Model DE-1, VDE-1 and DE-2 Air Release Heads

Radar, Ultrasonic and RF Level Transmitters

LVU2800 Series. Ultrasonic Level Transmitter

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids

For Multi-Parameter Meters see mvx

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Royce Interface Level Analyzer and Sensors

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

Autocalibration Systems for In Situ Oxygen Analyzers

How to specify a product. Process Sensors and Mechanical Instruments

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

CONTROL and INSTRUMENTATION

Mass Flow Controllers

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

SPECIFICATIONS ATTENTION

Best Practices in Measuring Tank Level

For Multi-Parameter Meters see mvx

Pro-V Multivariable Flowmeter

SERIES METAL TUBE VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Ultrasonic level transmitter and indicator

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Model 130M Pneumatic Controller

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Point level switches for safety systems

Echotel Model 3P1 Pump Controller and Ultrasonic Level Transmitter

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

RAM Operation Manual

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

Features. Description

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

DTG - LCD Digital Temperature Gauge USER MANUAL

Level transmitter LT 100

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

Liquid Level Controllers

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

GAS FUEL VALVE FORM AGV5 OM 8-03

SINGLE VALVE WITH LOW-FLOW BYPASS

Hydrostatic & Submersible. Level instruments. for the Australian market

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Ultra High Purity Model 780S

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

Level MEASUREMENT 1/2016

Differential Pressure Transmiter

ACV-10 Automatic Control Valve

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

process measurement solutions The level solutions catalogue

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SSL. Smart Valve Positioner.

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Additel 761 Automated Pressure Calibrators Selection Guide

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

Additel 761 Automated Pressure Calibrators

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S06*

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

Variable Area Flow Meters

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Mobrey MLT100 Displacer Level Transmitter

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System

HBLT-A1 LIQUID LEVEL SENSOR

SITRANS P measuring instruments for pressure

Additel 761 Automated Pressure Calibrators Selection Guide

3.0 Pressure Transmitter Selection

SDX Submersible Depth Transmitter User Manual

RAM 4021-DPX Operation Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Liquid level switch BM 34

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

THERMAL MASS FLOW MEASUREMENT FOR GASES

Porter Analytical & Industrial Products

Turbine Flowmeters for Gas Applications

Transcription:

DREXELBROOK A Leader In Level Measurement Solutions VeriGAP 504-1200 Series Two-Wire Ultrasonic Switch Ideal for Spill Prevention The two-wire gap switch is ideal as a high-level spill prevention system for non-coating liquids. A special patented circuit lets you meet spill prevention regulations and prevent unnecessary down-time, lost products, and regulatory fines. No Calibration Ever The unit needs no calibration or gain adjustments, regardless of the material to be measured. Measurement not affected by variations in liquid viscosity, density, pressure or electrical properties. Simple, Economical Installation One piece design for simplified installation and operation. Two-wire design eliminates the need for line power, conduit, or pull boxes in the field. Sensing element is easily installed in existing vessel openings, and of course...no calibration is needed. Intrinsically Safe Operation Transmitter and signal are FM approved intrinsically safe when powered from an intrinsically safe source. No Calibration Needed The 504-1200 Series two-wire level switch is an integral unit assembly which senses liquid presence by ultrasonic techniques. No calibration of any kind is needed. Completely Self-Checking The optional test checks not only the electronics, but also the relay and the entire control loop, including final control elements. When the circuit is activated at the push of a button, a signal is sent to the electronics to check the integrity of the sensing element and crystals and then simulate a high level in the tank. If the unit alarms, the operator knows that it will respond during an actual high level situation. This feature can also be paired with our Auto receivers, which initiate the test every 10 seconds, but do not let the relays activate any final controls or alarming. If the unit should fail the test, a separate fault relay is activated. A manual override allows for the vital testing of the full control loop. Two-Wire Operation This two-wire device changes its current state from normal to alarm when liquid bridges the sensor gap. During normal operating conditions, the unit draws 14-20mA, and during alarm conditions, the unit draws 4-10mA. Any other currents outside these windows causes Drexelbrook two-wire receivers to generate a fault alarm, giving you continuous loop diagnostics (open and short circuit, disconnected loop wires) and control or indication of liquid level at that

VeriGAP 504-1200 Series Specifications Power Requirements: 13-30 Vdc, 50/60 Hz Level Output: 4-10 ma (Alarm State), 14-20 ma (Normal State) RFI Effect: No effect on operating point from a 5-watt field @27,150 or 450 MHz Dimensions: Operating Temperature: -40 F to 160 F (note 1) : High Level or Low Level (Field- Selectable) Repeatability: 1/16 Response Time: 50 microseconds Housing: Nema 1 to 4X, 5 & 12 Area Classification: Class 1 Div. I or II, Groups A,B,C,D, Class 2 Div. I or II Groups E, F, and G s - note 3 Model Number (System Number) Mat'l of Construction Standard Mounting Process Temperature Process Pressure Standard Comments 705-1-1 (504-1200-1) 3/4-inch NPT -40 F to 250 F 1000 PSIG Max. 2 3/8, 6 3/8, 12 3/8, 18 3/8,or 24 3/8 inches 705-1-5 (504-1200-5) Hast. C 3/4-inch NPT -40 F to 250 F 1000 PSIG Max. 2 3/8-inches 705-1-601 (504-1200-8) 1 1/2-inch Triclamp -40 F to 250 F 1000 PSIG Max. 2 3/8-inches 3A Approved sanitary 705-31-1 (504-1200-2) 1-inch NPT -40 F to 250 F 50 PSIG Max. Adjustable from 2 to 36 inches 705-2-1 504-1200-11) 3/4-inch NPT -40 F to 350 F 1000 PSIG Max. 2 3/8, 6 3/8, 12 3/8, 18 3/8,or 24 3/8 inches with 6-inch cooling extension 705-2-5 (504-1200-15) Hast. C 3/4-inch NPT -40 F to 350 F 1000 PSIG Max. 2 3/8-inches with 6-inch cooling extension 705-32-1 (504-1200-31) 1-inch NPT -40 F to 350 F 50 PSIG Max. Adjustable from 2 to 36 inches Note 1: Unit will operate above 160 F with reduced component life. Note 2: For critical applications, it is recommended to use a combination of the two wire ultrasonic gap switch and the two-wire RF Admittance transmitter (LCT ) as High and High-High alarms. Both systems have features and can be tied to a single power-supply receiver. Note 3: Other sensors are available. See your Drexelbrook representative for your specific requirement. U.S.A. Sales: 800-553-9092 24-Hour Service: 800-527-6297 International Support: 215-674-1234 Fax: 215-674-2731 AMETEK Nihon Drexelbrook AMETEK Singapore Pte. Ltd. AMETEK Precision Instruments Europe 2 Chome 12-7 Minami Gyotoku 10 Ang Mo Kio Street 65 Rudolf-Diesel-Strasse 16 DREXELBROOK Ichikawa City Chiba 27201 Japan #05-12 Techpoint 569059 Singapore D-40670 Meerbusch Germany Phone: 81-473-56-6513 Phone: 65-6484-2388 Phone: 49-2159-9136-0 Fax: 81-473-56-6535 Fax: 65-6481-6588 Fax: 49-2159-9136-39 205 Keith Valley Road E-mail: nd@nihon-drexelbrook.co.jp E-mail: aspl@ametek.com.sg Web: www.ametek.de Horsham PA 19044 U.S.A. E-mail - drexelbrook.info@ametek.com Web - www.drexelbrook.com 2003, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. 504-1200-000-A EDO#2-04-246 Issue 5

504-1200-1 VeriGAP Point Level Control featuring 705-1-1 Containment Dikes Waste Sumps Overfill Protection 4.3 (109) 3.62 (92) 2.45 (62) Pressure and Temperature Limits 1000 psi (69 BAR) @ 250 F (121 C) Higher temperature units available. Materials corrosive to Methyl ethyl ketone 1 (35) Dimensions in inches (mm) Wrench Flat to ) Operate Point (9.5).875 (22.2) Process Wetted Parts details, request drawing 504-1200-001-CD1. 504-1 2 0 0-0 0 1 VeriGAP Series Point Level Control 404-1 2 0 0-0 0 0 = Single 0 = Without V = With (Requires 5"housing) 7 = 3½" Integral A = 3½" Integral with Drexelcote B = 5" Integral Units with require HLFS. 705-0001-001- I 002.0 BA0 Operating Point = operating point + 3/8" Maximum recommended insertion length = 60 inches For longer lengths, consult factory. Probe Mountings BA0 = ¾" NPT (standard) BBB= 1" 150# RF 316SS BDB= 1½" 150# RF 316SS BFB = 2" 150# RF 316SS BIB = 3" 150# RF 316SS BKB= 4" 150# RF 316SS BMB= 6" 150# RF 316SS BCB= 1" 300# RF 316SS BEB = 1½" 300# RF 316SS BGB= 2" 300# RF 316SS BJB = 3" 300# RF 316SS BLB = 4" 300# RF 316SS BNB= 6" 300# RF 316SS 504-1200-1-MN Issue 1

504-1200-8 VeriGAP Point Level Control featuring 705-1-601 for Sanitary Applications Milk Juices Beer (ignores foam) 2.45 (62) Materials corrosive to Pressure and Temperature Limits 1000 psi (69 BAR) @ 250 F (121 C) or Higher temperature units available. 4.3 (109) 3.62 (92) Process Wetted Parts with 3A approved sanitary fitting 1 (35) Wrench Flat to ) 1½" Tri-clamp Fitting details, request drawing 504-1200-001-CD1. Operate Point (9.5).875 (22.2) Dimensions in inches (mm) 504-1 2 0 0-0 0 8 VeriGAP Series Point Level Control 404-1 2 0 0-0 0 0 = Single 0 = Without V = With (Requires 5"housing) 7 = 3½" Integral A = 3½" Integral with Drexelcote B = 5" Integral Units with require HLFS. 705-0001-601- I 002.0 BC2 Operating Point = operating point + 3/8" Maximum recommended inser tion length = 60 inches For longer lengths, consult factor. y Probe Mountings BC2 = 1 ½" Tri clamp 316SS (Standard) BE2 = 2" Tri clamp 316SS BJ2 = 3" Tri clamp 316SS BL2 = 4" Tri clamp 316SS 504-1200-8-MN Issue 1

504-1200-21 VeriGAP TM Point Level Control featuring 700-31-1 with Adjustable Tank Car Loading Containment Dikes Waste Sumps Overfill Protection 2.8 (58) Materials corrosive to Dimensions in inches (mm) Pressure and Temperature Limits 50 psi (3.5 BAR) @ 250 F (121 C) Higher temperature units available. Process Wetted Parts 6 (152) 42 ¾-inch Wrench Flat NPT to ) 36 1-inch NPT 12 6.875 (22.2) (9.5) Operate Point details, request drawings 504-1200-1-CD3. 7 (187) 1 (35) 504-1 2 0 0-0 2 1 VeriGAP Series Point Level Control 404-1 2 0 0-0 0 0 = Single 0 = Without V = With (Requires 5"housing) 7 = 3½" Integral A = 3½" Integral with Drexelcote B = 5" Integral Units with require HLFS. 705-0031- 001- I 036.0 BB0 Operating Point = operating point + 3/8" Maximum recommended insertion length = 48 inches For longer lengths, consult factory. Probe Mounting BB0 = 1" NPT (standard) 504-1200-21-MN Issue 1

504-1260-1 VeriGAP TM Point Level Control featuring 700-21-1 with Dual Batching Processes Waste Sumps Pump Control Materials corrosive to ¾-inch NPT 5-inch Condulet Wrench Flat to ) 5.0 (127).59 (15) 6.6 (167) 1.5 (38) approx. Pressure and Temperature Limits: 1000 psi (69 BAR) @ 250 F (121 C) Process Wetted Parts: Operate High Point ¾-inch NPT 1.45 (37) details, request drawing 504-1260-1-CD1. High/Low Operate Low Point 504-1 2 6 0-0 0 1 (9.5).84 (21) Distance in inches (mm) Minimum distance between upper and lower point is 3 inches. VeriGAP Series Point Level Control 404-1 2 6 0-0 0 6 = Dual 0 = Without V = With (Requires 5"housing) B = 5" Integral (standard for Dual ) Units with require HLFS 705-0001-021- I 004.0 BA0 Lower Operating Point = operating point + 3/8" Maximum recommended insertion length = 60 inches For longer lengths, consult factory. Probe Mountings BA0 = ¾" NPT (standard) BBB = 1" 150# RF 316SS BDB = 1½" 150# RF 316SS BFB = 2" 150# RF 316SS BIB = 3" 150# RF 316SS BKB = 4" 150# RF 316SS BMB = 6" 150# RF 316SS BCB = 1" 300# RF 316SS BEB = 1½" 300# RF 316SS BGB = 2" 300# RF 316SS BJB = 3" 300# RF 316SS BLB = 4" 300# RF 316SS BNB = 6" 300# RF 316SS Upper Operating Point Operating Point in inches = 00.0 (example 12 inches = 12.0) 02.0. 504-1260-1-MN Issue 1