B84G - Excelon Plus Modular System General purpose filter/regulator

Similar documents
B84G - Excelon Plus Modular System General purpose filter/regulator

R84G - Excelon Plus Modular System Pressure regulators

B74G - EXCELON Modular System General purpose filter/regulator

R18 General purpose pressure regulators

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

F68G - Olympian Plus plug-in system General purpose filter

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

Precision and Instrument Regulators 1/4" port size

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

EXCELON QUIKCLAMP SYSTEM Pressure relief valves V72G, V74G - G1/4... G 3/4

Series K Air service units G 1/8, G 1/4

Modular Type Regulators

Air service units series K G1/8, G1/4

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

Regulators/valves Compressed air regulators Without filter

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

How to Order. Rc NPT 1/8 1/4 3/8 1/2

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

ALF400 to 900, ALT-5/-9

Related Products: Auto Drain Valve. Model/Specifications. Model

MINIATURE COMBINATION UNITS Filter/regulators and lubricators P1H - G1/8, G1/4

PARTICULATE FILTER/REGULATOR

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

AIR TREATMENT H Z E 0. Air Treatment Units CHARACTERISTICS CODIFICATION KEY. Filter. Ambient temperature Fluid Working pressure Max pressure Size Body

Direct Operated Precision Regulator Modular Style. Standard Specifications

Standard Specifications

1200 Series Pressure Regulators

1 8 A N D 2 8 S E R I E S

Modular Air Combination Units

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Filter-Regulator-Lubricator

Avenger Model 33M Installation & Operation Instructions

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Symbols. Bowl type Poly bowl with bowl guard G Metal bowl without sight gauge M. Drain type 5μ Element

Filter-Regulator-Lubricator

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter

Air-service devices, Series MU1

accidents which arise due to non-observance of these instructions and the safety information herein.

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

MF2M Monnier Miniature Compressed Air Filter

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

LRS(H)4 Pressure-Reducing Regulator User Manual

Nugget 120 V14 Series

Booster Regulator/Air Tank

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Air service units series Y G1/4 to G1

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Series MX pressure regulators 3/

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Air preparation units

VACUUM REGULATORS CONTENTS

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Precision Regulator. Series Model Regulating pressure range Port size Page

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

FR12MD FR38MD. Modular filter-regulators, suitable for compressed air FEATURES. Filter-regulator for inlet pressure up to 30 bar (435 psi).

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Float Operated Level Controllers

Precision pressure regulators LRP/LRPS

SPCH/ Blowing block

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

PRO-50 Instrument Supply Regulator

Modular F.R.L. Units. New. New. Series AC 46% Better visibility and environmental resistance. Energy saving regulator

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Masoneilan* 78 Model Air Filter Regulator

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

SATURNSERIES INTERCHANGE > ISO (for the couplings)

Non-Return Valves T55 Series

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

ALF400 to 900, ALT-5/-9

INSTALLATION & MAINTENANCE INSTRUCTIONS

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

FILTER REGULATOR. We produce with artistic attitude.

Electropneumatic Transducer (I/P) Installation, Operation and

Regulator/Modular Style AR1000 to 6000

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Transcription:

> Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant feature > Metal bowl with prismatic liquid level indicator lens > 5 or 40 micron particle and high efficiency water removal (> 98%) > Light weight Polycarbonate bowl with guard > Double safety lock bowl > Easy to read flush mounted integrated pressure gauge Technical features Medium: Compressed air only Maximum supply pressure: Polycarbonate bowl: 145 psi (10 bar) Metal bowl: 290 psi (20 bar) Outlet pressure ranges: 4 to 145 psi (0.3 to 10 bar), 4 to 58 psi (0.3 to 4 bar), 2 to 250 psi (0.7 to 17 bar) Filter element: 5 μm & 40 μm Port size: G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTF Gauge: Integrated as standard Gauge port 1/8 as option Flow: 212 scfm (100 dm 3 /s) At port size: 1/2", inlet pressure 145 psi (10 bar), 91 psi (6.3 bar) set pressure and a Δp: 14.5 psi (1 bar) droop from set. Filter element: 40 μm Diaphragm Type: Relieving Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 5 psi (0.35 bar) Bowl pressure required to open drain: 2.9 psi (0.2 bar) Minimum air flow required to close drain: 2 scfm (1 dm 3 /s) Ambient/Media temperature: Polycarbonate bowl: +14 to +140ºF (-10 to +60ºC) Metal bowl: -4 to +149ºF (-20 to +65ºC) Air supply must be dry enough to avoid ice formation at temperatures below +35 F (+2 C). Materials: Body: Die cast aluminum Body covers: ABS Bonnet: Acetal/ Aluminum Valve: PP Bowl: Transparent PC with PP guard or die cast aluminum Liquid level indicator lens (metal bowl): PA Filter element: sintered PP Bowl o - ring: Chloroprene Elastomers: NBR Technical data B84G - standard models Symbol Port Drain Pressure range Filter element Bowl Weight Model *1) Automatic Drain Relieving Manual Drain Relieving PTF psi (bar) (µm) lb (kg) 3/8 Auto 5 to 145 (0.3 to 10) 40 Guarded polycarbonate 1.6 (0.73) B84G-3AK-AP3-RMG 1/2 Auto 5 to 145 (0.3 to 10) 40 Guarded polycarbonate 1.6 (0.73) B84G-4AK-AP3-RMG 3/4 Auto 5 to 145 (0.3 to 10) 40 Guarded polycarbonate 1.6 (0.73) B84G-6AK-AP3-RMG 3/8 Auto 5 to 145 (0.3 to 10) 40 Metal with level indicator 1.9 (0.88) B84G-3AK-AD3-RMG 1/2 Auto 5 to 145 (0.3 to 10) 40 Metal with level indicator 1.9 (0.88) B84G-4AK-AD3-RMG 3/4 Auto 5 to 145 (0.3 to 10) 40 Metal with level indicator 1.9 (0.88) B84G-6AK-AD3-RMG 3/8 Manual 5 to 145 (0.3 to 10) 40 Guarded polycarbonate 1.6 (0.73) B84G-3AK-QP3-RMG 1/2 Manual 5 to 145 (0.3 to 10) 40 Guarded polycarbonate 1.6 (0.73) B84G-4AK-QP3-RMG 3/4 Manual 5 to 145 (0.3 to 10) 40 Guarded polycarbonate 1.6 (0.73) B84G-6AK-QP3-RMG 3/8 Manual 5 to 145 (0.3 to 10) 40 Metal with level indicator 1.9 (0.88) B84G-3AK-QD3-RMG 1/2 Manual 5 to 145 (0.3 to 10) 40 Metal with level indicator 1.9 (0.88) B84G-4AK-QD3-RMG 3/4 Manual 5 to 145 (0.3 to 10) 40 Metal with level indicator 1.9 (0.88) B84G-6AK-QD3-RMG *1) All models shown here are supplied with integrated gauge applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact IMI Norgren us 8.200.350/01

Option selector *1) Port size 3/8" 3 1/2" 4 3/4" 6 Thread form PTF ISO G parallel Adjustment Knob T-bar Drain Manual Auto drain Bowl Metal with liquid indicator Transparent with guard A G K T*2) Q A *1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact IMI Norgren *2) Units with 246 psi (17 bar) outlet pressure range are available only with the T-bar adjustment; therefore substitute T at the 7th position and S at the 9th position. T-bar handle only available with 17 bar option. D P B84G-HHH-HHH-RHH Gauge With integrated gauge Without integrated gauge but with gauge port 1/8 Pressure range *3) G N 5 to 58 psi (0.3 to 4 bar) F 5 to 145 psi (0.3 to 10 bar) M 10 to 246 psi (0.7 to 17 bar) S*2) Element 40 µm 3 5 µm 1 *3) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. Flow characteristics bar 8 psig PORT SIZE: 1/2", ELEMENT: 40µm INLET PRESSURE: 145 psig (10 bar) RANGE: 5 to 145 psig (0.3 to 10 bar) 100 OUTLET PRESSURE 6 4 2 80 60 40 20 0 0 0 40 80 120 160 200 scfm 0 20 40 60 80 100 dm 3 /s AIR FLOW us 8.200.350/02

Accessories Quikclamp Quikclamp with bracket assembled Neck mounting bracket & Panel nut Panel mounting nut Mounting bracket Page 6 Page 6 Page 6 Page 6 Page 6 840014-51KIT 840014-52KIT 840068-51KIT 840048-89KIT 840024-50KIT Integrated gauge 10 bar gauge Integrated gauge 20 bar gauge Gauge adaptor kit 1/8 PTF Gauge adaptor kit R 1/8 840073-01KIT 840073-02KIT 840100-01KIT 840100-02KIT Pressure sensing block 1/4 PTF Pressure sensing block G1/4 Padlock Lockout device Page 7 Page 7 840016-50KIT 840016-51KIT 840055-01KIT 840055-02KIT 3/4 PTF G3/4 Pressure switch interface block (18D pressure switch) G1/2 Pneumatic pressure switch 18D (7 to 120 psi) Digital pressure switch 51D (-14 to 145 psi) Page 7 Page 7 Page 7 Page 7 Page 8 840028-50KIT 840028-53KIT 0337717000000000 0881300000000000 0860811000000000 Port Adaptors 3/4 PTF G3/4 Page 7 3/8 PTF 840015-02KIT 1/2 PTF 840015-03KIT 3/4 PTF 840015-04KIT G3/8 840015-10KIT G1/2 840015-11KIT G3/4 840015-12KIT Page 6 Page 6 840028-68KIT 840028-69KIT us 8.200.350/03

Gauges (For regulators with gauge port instead of integrated gauge) Center back connection, white face Center back connection, black face Pressure range (psi) (bar) *3) (MPa) ø Thread size Model 0 to 84 0 to 6 0 to 0.6 2" R1/8 18-015-012 0 to 145 0 to 10 0 to 1 2" R1/8 18-015-013 0 to 362 0 to 25 0 to 2.5 2" R1/8 18-015-014 *3) primary scale Pressure range (psi) *3) (bar) (MPa) ø Thread size Model 0 to 60 0 to 4 0 to 0.4 2" 1/8" NPT 18-015-202 0 to 160 0 to 11 0 to 1.1 2" 1/8" NPT 18-015-204 0 to 300 0 to 20 0 to 2.1 2" 1/8" NPT 18-015-205 *3) primary scale Maintenance/Service Auto drain kit with metal Nut - inch Auto drain kit with metal Nut - Metric R84 / B84 Elastomer Kit Filter cartridges 5 micron Filter cartridges 40 micron 6000-61KIT 6000-60KIT FRLB84-KIT 840038-50KIT 840038-51KIT Spare parts (Guarded Poly bowl with auto drain 6 mm PIF) (Guarded Poly bowl with manual drain) (Metal with S/Glass & auto drain, 6 mm PIF) (Metal with S/Glass & manual drain) 840025-51KIT 840025-50KIT 840003-51KIT 840003-50KIT (Guarded Poly bowl with auto drain, 1/4 PIF) (Metal with S/Glass & auto drain, 1/4 PIF) 840025-53KIT 840003-56KIT us 8.200.350/04

# 0.98 (25) # 0.98 (25) 7.13 (181) 1.69 (43) 1.54 (39) 0.63 (16) 4.53 (115) 4.88 (124) B84G - Excelon Plus Modular System Dimensions Dimensions in inches (mm) Projection/Third angle 1.54 (39) 0.63 (16) 4.53 (115) 4.88 (124) 5.63 (143) 2.91 (74) 1.50 (38) 2.28 (58) 2.76 (70) 1.69 (43) 1 1 1.69 (43) 2 7.01 (178) 7.01 (178) 8.07 (205) 1/4 Turn Manual Drain Automatic Drain 1/4 Turn Manual Drain With knob With T-bar # Minimum clearance for bowl removal 1 Main ports 3/8, 1/2 or 3/4 (ISO G/PTF) 2 Gauge port Rc 1/8 for ISO G and 1/8 PTF for PTF main ports us 8.200.350/05

0.31 (8) 0.20 (5) 1.42 (36) 1.85 (47) 1.14 (29) 2.24 (57) 1.38 (35) 0.91 (23) 0.28 (7.2) 0.08 (2) 2.36 (60) 1.97 (50) 3.35 (85) 0.31 (8) 1.39 (35.2) 1.93 (49) 2.14 (54.3) 4.69 (119) 2.20 (56) 1.85 (47) 2.13 (54) B84G - Excelon Plus Modular System Accessories Dimensions in inches (mm) Projection/Third angle Quikclamp with wall bracket Quikclamp 0.55 (14) 2.01 (51) 0.28 (7) 2.30 (76) 0.45 (11.5) 2.36 (60) 4 0.20 (5) Neck mounting bracket Panel mounting nut 1.42 (36) 0.59 (15) Mounting bracket 0.35 0.59 (8.9) (15) 2.80 (71) 2.28 (58) 0.59 (15) 0.71 (18) 0.16 (4) 2.60 (66) 1.22 (31) us 8.200.350/06

1.57 (40) 1.57 (40) 1.52 (38.5) 1.18 (30) 0.20 (5) 1.77 (45) 18 A/C 1.81 (46) 2.24 (57) 2.01 (51) B84G - Excelon Plus Modular System Pressure sensing block Dimensions in inches (mm) Projection/Third angle 3.15 (80) 2.01 (51) 2.70 (68) 1.77 (45) 0.83 (21) 1.30 (33) Porting block for 18D pressure switch 18D Pressure switch 1.08 (27.5) 1.26 (32) 1.73 (44) G1/2 2.57 (40) 1.18 (30) 1.38 (35) 2.83 (72) 18D Porting block and 18D assembled Pipe adaptor Full flow vertical porting block 1.52 (38.5) 0.71 (18) 2.24 (57) 1.77 (45) 2.68 (68) 3.15 (80) 1.26 (32) 1.73 (44) G1/2 1.57 (40) 2.24 (57) us 8.200.350/07

51D Pressure switch - digital 1.22 (31) 1.44 (36.5) Dimensions in inches (mm) Projection/Third angle 1 2 ~1.18 (30) 3 ~11.8 (300) 1.22 (31) 6 5 7 1/8" PTF 1 Switch OUT 1, green LED 2 Switch OUT 2, red LED 3 Dustproof protector 4 Connector M12 x 1 5 Inlet port 6 Alternative inlet port G1/8 plugged 7 Thread for mounting screw 4 Warning Improper selection, misuse, age or malfunction of components used in systems can cause failure in various modes. The system designer is warned to consider the failure modes of all component parts and to provide adequate safeguards to prevent personal injury or damage to equipment or property in the event of such failure modes. System designers and end users are cautioned to consult instruction sheets and specifications available from the factory. The system designer/end user is responsible for verifying that all requirements for the application are met. Warranty The products described herein are warranted subject to seller s Standard Terms and Condition of Sale, available at seller s website. Proposition 65: These products may contain chemicals known to the state of California to cause cancer, or birth defects, or other reproductive harm. us 8.200.350/08