Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Similar documents
BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Choosing a Quadrupole Gas Analyzer Application Note #9

Practical approach and problems in in-situ RGA calibration

High Performance Mass Spectrometers

Quadruple mass spectrometers (transducer type)

Residual Gas Analysis Systems for Industry

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Zebron Gas Management

Standard Operating Manual

Notes-PECVD: Chamber 1

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

A Mass Spectrometry Method for Water Vapour Transmission Rate (WVTR) testing to 10-6 gm/m 2 /day, utilising Deuterium Oxide

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

Standard Operating Manual

Standard Operating Manual

Gun Vacuum Performance Measurements February 2003

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

Marc McMullen. Physics Detector Support Group

The Broadest Gauging Line in the Industry

The Principles of Vacuum Technology

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Unaxis ICP/RIE SOP Revision 8 09/30/16 Page 1 of 5. NRF Unaxis ICP/RIE Etch SOP

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

The use of remote plasma emission spectroscopy as an alternative method of gas sensing for direct monitoring of vacuum processes

Operating Procedures for the. SAMCO ICP RIE System

EasyLine Continuous Gas Analyzers. So smart, they re simple

Total Pressure Measurement Using Residual Gas Analyzers

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

GasSense NDIR User Manual

Usage Policies Notebook for Xenon Difluoride (XeF 2 ) Isotropic Si Etch

Products for Cryogenic Applications

Application Note. ASTRON Remote Plasma Source Ignition Best Practices PROBLEM

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Determination of the Vacuum System for R2R by using a New Pumping Simulation Program

The Helium Leak Detector

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Leak Checking Large Vacuum Chambers

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

8.1 Calibration of gas sensors

SPUTTER STATION STANDARD OPERATING PROCEDURE

VS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Detecting Hydrogen in Helium Streams. Samuel Goodman. Pittsford Mendon High School. Rochester, New York. Advisor: Dr.

UNIVERSAL MASK TEST SYSTEM

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

DC gun high voltage conditioning with Krypton gas Carlos Hernandez-Garcia October 2008

Indian Institute of Technology Kanpur Samtel Centre for Display Technologies

Mass Spec will not Autotune

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Plasma Asher: March PX-500 User guide (May-30, 2017)

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

The Air Liquide Gas System Equipment Brochure

STS ICP-RIE. Scott Munro (2-4826,

STS PECVD Instructions

628 Differential Pressure Decay Leak Tester

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.

CHEMICAL ENGINEERING SENIOR LABORATORY CHEG Initiated Chemical Vapor Deposition

Miniature Electronic Pressure Controllers. Precision Fluidics

Best Practice Guide, Servomex 2700

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

Major Design Features

Operating Procedures for Metal Evaporator I

MANUAL FOR SPTS APS (DIELECTRICS ETCHER)

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Hiden QIC Series Gas Analysers Real-time gas analysis systems


Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Chapter 2 General description of the system

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

This test shall be carried out on all vehicles equipped with open type traction batteries.

Columbus Instruments

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

Arizona State University Center for Solid State Electronic Research. Table of Contents. Issue: C Title: Oxford Plasmalab 80plus (Floey) Page 1 of 8

Overview. Front Panel: Keypad and Display

3200 Dwight Road Suite #100 Elk Grove, CA Ph: Fax: GNB Corporation

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

FT28_mks.qxp 21/11/ :06 Page 1

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Model 4000 Pressure Controller

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Hazards associated with the gas system and how to mitigate them

Mass Flow Controller (MFC) for Gases

School of Chemistry SOP For Operation Of Glove Boxes

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents

PHOENIX L300i Best-in-class Helium Leak Detectors

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Thermo Scientific Model 146i Principle of Operation

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

NGN Series nitrogen generator

Transcription:

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Backup: What s an RGA Residual Gas Analyzer An instrument that is measuring the gas composition in a chamber based on the formation of ions and detection of thier mass to charge ratio.

Field examples of RGA usage Tool Monitor stages. - Pump down - Leak check - Bake out - H2O monitor - Production - Bellow - Gas/internal leak - Idle - Leak monitor - Pump efficiency Process Monitor stages. - Bellow leak monitor - Gas leak monitor - Chamber cross contamination - Contaminated product monitor Process Control types. - Degas Endpoint - Chamber Clean Endpoint - Desorption gas monitor - O2 partial pressure control

Optimize RGA usage through tool and host integration and automation Digital signal interface. - PLC - Tool interlock - Pneumatic switch Winsockets. - Internet Explorer - Labview - ProcessEye SEMI standards. - Polling - Trace - Events In-line or cluster tools Automated calibration and health checking Integrated to stop tool, interdiction via factory host or passive alarms Internal reports, automated alarm Pareto and integration with factory SPC RGA control software can take other sensor inputs which then benefit from the automation

Bake out/pump down data TOOL A TOOL B TOOL C TOOL D Not much change after (5hrs)10X30mins in H2O 4 tools exhibits different H20 curve but all showed no more improvement after 5hrs. Optimise bake out reduced to 6hours from 9hours.

Bellow leak data(transfer chamber) Nitrogen monitoring Bellow of slit valve leak monitoring. Data sent to customer SPC chart.

Bellow leak data (loadlock) LL1 LL2 LL3 LL4 LL4 LL1 LL2 LL3 Loadlock 4 leaking, high N2 and O2.

Problem on large in-line glass panel tool Detected within a few days of installing RGAs During product processing at 8mT operating pressure Water leak from tool cooling lines. Spikes due to leak/refreeze cycle in vacuum

Contamination monitoring inline panel carrier movement Note: Significant increase of water and hydrocarbon contamination Conclusion: Carrier contamination and chamber condition after PM need to be considered as a significant factor for the film properties.

Reactive PVD process control using HPQ2S High Pressure RGA Mini-Quadrupole sensor Insertion length 1 inch Operation up to 1 mtorr / 8 mt (HPQ2-S) No differential pumping 2-80 amu mass range Faraday Cup detector Sensitivity < 5 ppm

Overview/Requirements Metallic mode: high deposition rate high refraction index absorption and low transmission Intended process mode transition mode high deposition rate low refraction index (for SiO2 n<1,5) no absorption and high transmission good long time stability but process regulation is necessary Oxide mode: low deposition rate low refraction index (for SiO2 n<1,5) no absorption and high transmission bad long time stability - Arcing O2 gas flow

Power Partial oxygen gas pressure regulation Measure the O2 partial pressure and control the cathode power if O2 concentration rises, than controller will increase the cathode power; than the process consume more O2 and will come back to the old working point Analogous if O2 concentration decline, the cathode power will be reduced stable layer properties during the whole target lifetime Control O2 concentration

Data example O2 Partial Pressure O2 Concentration relative to the total pressure Output voltage (0-10 VDC) Control phase

CVD Chamber Clean optimization using a V2000C Removing of SiO2 from the process chamber walls Prevent the etching of chamber components Reduction of the consumption of NF3 or other expensive clean gases Reliable monitoring of the etched material signal(sif3)

Vision 2000-C UniBloc Inlet 4 Valve Configuration For process pressure >10 torr Includes bypass pumping line Facilitates circulation of sample gas to optimize response time Four Valve UniBloc Baratron Gauge MKS V 2 MKS Vacuum Switch for Purge protect MKS V 1 V 3 V 4 Inert gas purge for turbo & UniBloc when V1 & V2 are closed Orifices sized to suit inlet pressures Analyzer MKS Configuration for CVD MKS Base pressure: Process pressure: Purged Tubo/Drag Pump Baratron Gauge Stand-by: MKS Foreline Surge protect Tool Dry Pump

NF3 based Chamber clean SiF3 F NF3

NF3 usage improvements on chamber clean optimization 2 wafers and clean compared to 4 wafers and clean Less gas used Higher chamber utilisation

Conclusions Standard direct insertion RGAs provide excellent troubleshooting capability for leak checking Post PM Baseline monitoring when tool idle High vacuum transfer chamber monitoring Process RGAs which can work at higher pressures as well as baseline offer the highest productivity by trapping leaks and gas level exclusions throughout the process Integrating RGAs with tool controllers and factory automation increase productivity and value For RGAs For non-rga sensors For tool data For closed loop control For end-point determination

Thank you!