DPS-400 SERIES DPH-100 SERIES

Similar documents
Visualize Nitrogen Gas Consumption

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Digital Flow Switch. Series PFM7

Compact Pressure Switch

Proportional pressure regulators VPPE

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

OPTIBAR P 1010 C Technical Datasheet

AMS 2710 PCB pressure sensor module with V output

Compact Pressure Switch

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

MANUAL KPS Pressure Control Valve

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Technical Data. Dimensions

How to Order. Rc NPT 1/8 1/4 3/8 1/2

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

High-performance submersible pressure transmitter For level measurement Model LH-10

JUMO dtrans p30 Pressure Transmitter

PSE Series. Remote Type Pressure Sensors/Pressure Sensor Controllers PSE550 ISE70 PS ISA3 ISA2 ISE35 PSE IS ISG ZSM1

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

High-performance submersible pressure transmitter For level measurement Model LH-10

P499 Heavy Duty Pressure Transducer

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

2-Color Display Digital Flow Switch

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Technical Specifications

Multistage Ejector Series ZL

Multistage Ejector Series ZL

Direct Operated Precision Regulator Modular Style. Standard Specifications

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Differential Pressure Transmiter

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

Technical Data. Dimensions

Non-corrosive gas Liquid. Corrosive gas

Digital electro-pneumatic regulators Series ER100

Technical Data. Dimensions

User Manual V14.1 IP68 LED FLEX NEON

MPM280 Piezoresistive OEM Pressure Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INSTRUCTION MANUAL Pressure Relief Device LPT

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

Inverse Proportional Pressure-Relief Cart., Size 2 4

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

Miniature controls. Contactors. Overload relays. Starters. Control relays

BS12N Piezoresistive OEM Pressure Sensor

Pressure transmitter PASCAL Ci4

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Proportional pressure regulators VPPM

MPM280 Piezoresistive OEM Pressure Sensor

Slit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV

BS12 Piezoresistive OEM Pressure Sensor

Technical Data. Dimensions

Technical Data. Dimensions

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Pressure Automated Calibration Equipment

Gas density monitor With integrated transmitter Model GDM-100-TI

SITRANS P measuring instruments for pressure

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Pressure Sensor/ PSE57 /PSE300AC Series CAT.ES A. 3-Screen Display Sensor Monitor. 500 VAC <Twice that of the PSE560> Remote Type

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

ATM.ECO - Analog Pressure Transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Technical Data. General specifications. Rated operating distance s n 5 mm

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito

Type 4708 Supply Pressure Regulator

TH-1800-T TRX-700-CNG Converter

Integral type Differential pressure flowmeter VNT Series

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

Pressure Sensor PSE53#

Series ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU

Type S-10, S-11 General Purpose Pressure Transmitters

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

2/ Port G1/4

VACUUM REGULATORS CONTENTS

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Booster Regulator/Air Tank

Precision pressure sensor Basic version Model CPT6020

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Pressure Sensor PSE54#

ATM - Analog Pressure Transmitter

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator

FTC130 Transmitter. Operating Manual

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

AMS 6916 Board mount pressure sensor with ratiometric analog output

Series IRV1000/2000/3000

Variable Area Flow Meters

GasSense NDIR User Manual

Electro-Pneumatic Converter YT-940 SERIES

Transcription:

745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO PHOTO MEASURE Thin body controller can do cascade connection and communication with upper devices Works like a fiber sensor DPS-400 series accommodates to the requirements for pressure sensors at production site such as miniaturization of sensors for downsizing equipment, convenient shape to fit into machines, and reduction of man-hours when it comes to replacement. Sensor head series Direct installation using a hexagonal wrench Direct mounting from above Installation in narrow spaces Extended freedom of layout Single axis type free turning structure panasonic.net/id/pidsx/global Controller DPS-400 series Thin body (t mm t 0.94 in) and multi-unit connection on a DIN rail helps to downsize equipment for better construction. Current value and threshold value can be checked simultaneously on the dual display The controller is equipped with a 4-digit dual digital display. Because the threshold value can be adjusted while checking the current value (current pressure value), direct setting and checking of the threshold value is made smoothly without having to switch screen modes. Digital Dual display + Direct setting Install on a DIN rail Because direct setting is possible Thickness mm 0.94 in Operation is as easy as analog Threshold value Current value The current value and the threshold value can be checked simultaneously!

Dual Display Digital Pressure Sensor DPS-400 SERIES SERIES 746 Wire-saving, space-saving The quick-connection cables enable reductions in wiring. The connections and man-hours for the relay terminal block setup can be reduced and valuable space is saved. Also, DPS-400 series can be connected side-by-side with fiber sensors FX-00 series or laser sensors LS-400 series. Wire-saving in power supply Fiber sensor FX-00 series DPS-400 series Wire-saving in power supply* DPS-400, FX-00, LS-400, etc. Up to 16 sensors can be connected togetther DPS-400 series Up to 16 sensors allowed in optical communication / setting copying PHOTO PHOTO Output line 1 Power supply cable Main cable CN-74-C Sub cable CN-72-C Only output lines are used, so that wiring can be greatly reduced and space saving can be obtained. Network communication Output line 2 Output line 2 Output line 16 Output line 16 Output line Output line * Check the instruction manual of each model for the arrangement order and such when connecting, as communication varies depending on the model. Can connect to Open Network CC-Link IE Field / CC-Link / DeviceNet / EtherCAT via Communication Unit for Open Network SC-GU series. Monitoring and various settings can be done from, PC, etc. Current values of connected sensors are shown. しきい値 現在値 1ch 90 65 2ch 50 0 ch 40 70 4ch 0 0 5ch 0 0 6ch 0 0 7ch 0 0 8ch 0 0 しきい値 現在値 9ch 0 0 ch 0 0 11ch 0 0 12ch 0 0 1ch 0 0 14ch 0 0 15ch 0 0 16ch 0 0 [Touch panel display example] Threshold values of connected sensors are shown. Communication Unit for Open Network SC-GU series End unit Digital pressure sensor Digital fiber sensor Digital fiber sensor Digital laser sensor DPS-401/402 FX-501/502 FX-01/05 LS-40/502 *CC-Link and CC-Link IE Field are a registered trademark of Mitsubishi Electric Corporation. DeviceNet is a registered trademark of ODVA (Open DeviceNet Vender Association, Inc.). EtherCAT is a registered trademark of Beckhoff Automation GmbH. * Refer to p.971~ for SC-GU series. Optical communication / setting copying Ultra high-speed response time at 150 μs Ultra high-speed response time contributes to even greater productivity. Response time at 150 μs Independent dual outputs and five output modes equipped The sensor is equipped with two independent comparative outputs in which separate sensing modes can be selected. EASY mode This mode is used for comparative output ON/OFF control. Hysteresis mode This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON/OFF control. Window comparator mode This mode is used for setting comparative output ON or OFF at pressures within the setting range. Forced output ON mode The comparative outputs are forcibly maintained at ON irrespective of the set values. Forced output OFF mode The comparative outputs are forcibly maintained at OFF irrespective of the set values. MEASURE

747 Dual Display Digital Pressure Sensor DPS-400 SERIES SERIES PHOTO PHOTO Hexagonal wrench installation saves man-hours and spaces Using a hexagonal wrench, obstructions can be avoided and installation can be done easily by turning the bolt from above. Previous problem Spanner is difficult to hold! (Obstructed by floor surface) Turns minimally from above! MEASURE Previous problem Large space needed to turn the spanner! Obstacle Previous problem Spanner cannot be turned! Quick maintenance During maintenance, the sensor head needed to be removed can be easily removed from directly above. Remove and install the required sensor head directly. Mounting shape at 14 mm 0.551 in Because the dead zone caused by the nut is eliminated, the narrowed-down thickness after installation contributes to space saving. Previous models Wasted space Saved space DPH- -M DPH- -M5 14 mm 0.551 in Previous models 75 mm 2.95 in 12.5 mm 0.492 in mm 0.94 in 60 mm 2.62 in 20 % DOWN from previous models

Dual Display Digital Pressure Sensor DPS-400 SERIES SERIES 748 ORDER GUIDE Controllers Type Appearance Model No. For compound pressure / vacuum pressure For positive pressure Quick-connection cables Main cable (4-core) Sub cable (2-core) DPS-401 DPS-402 Applicable sensor head DPH-1 DPH- DPH-2 Output NPN open-collector transistor two outputs Quick-connection cable is not supplied with the controller. Please order it separately. Type Appearance Model No. Description CN-74-C1 CN-74-C2 CN-74-C5 CN-72-C1 CN-72-C2 CN-72-C5 Length: 1 m.281 ft Length: 2 m 6.562 ft Length: 5 m 16.404 ft Length: 1 m.281 ft Length: 2 m 6.562 ft Length: 5 m 16.404 ft Connection method Use optional quick-connection cable (4-core) 0.2 mm 2 4-core cabtyre cable, with connector on one end Cable outer diameter: ø. mm ø0.10 in 0.2 mm 2 2-core cabtyre cable, with connector on one end Cable outer diameter: ø. mm ø0.10 in End plates End plates are not supplied with the controller. Please order them separately when the controllers are mounted in cascade. Appearance Model No. Description MS-DIN-E When cascading multiple controllers, or when it moves depending on the way it is installed on a DIN rail, these end plates clamp controllers into place on both sides. Make sure to use end plates when cascading multiple controllers together. Sensor heads Type Appearance Rated pressure range Model No. Pressure port DPH-1 R1/8 male thread + M5 female thread Compound DPH-1-M M male thread pressure DPH- -M(-R) 0.0 kpa to DPH-1-M5 M5 male thread Bendingresistant +0.0 kpa DPH-1-R R1/8 male thread + M5 female thread DPH-1-M-R M male thread cable DPH-1-M5-R M5 male thread Positive pressure DPH- -M5(-R) DPH-2 (Note) R1/8 male thread + M5 female thread 0 to +1.000 MPa DPH-2-M5 M5 male thread Bending-resistant cable DPH-2-M5-R M5 male thread DPH- R1/8 male thread + M5 female thread Vacuum pressure DPH--M M male thread DPH- (-R) DPH--M5 M5 male thread 0 to 1.0 kpa Bendingresistant DPH--R R1/8 male thread + M5 female thread DPH--M-R M male thread cable DPH--M5-R M5 male thread Applicable fluid Air, non-corrosive gas Note: The bending-resistant cable type of DPH-2 is not available. 5 m 16.404 ft cable length type 5 m 16.404 ft cable length type (standard: 2 m 6.562 ft) is also available. When ordering this type, suffix -C5 to the Model No. (e.g.) 5 m 16.404 ft cable length type of DPH--M5-R is DPH--M5-R-C5 Designation Model No. Description Controller mounting bracket MS-DIN-2 Mounting bracket for controller Controller protection seal FX-MB1 sets of 2 communication window seals and 1 connector seal Communication window seal: It prevents malfunction due to transmission signal from another controller, as well as, prevents effect on another controller. Connector seal: It prevents contact of any metal, etc., with the pins of the quick-connection cable. Controller mounting bracket MS-DIN-2 Controller protection seal FX-MB1 Communication window seal Connector seal

749 Dual Display Digital Pressure Sensor DPS-400 SERIES SERIES SPECIFICATIONS Controllers Sensor heads Item Type CE marking directive compliance Type of pressure Compound pressure Positive pressure Vacuum pressure ±0 kpa type 1 MPa type 1 kpa type Model No. (Note ) DPH-1(-R) DPH-1-M(-R) DPH-1-M5(-R) DPH-2 DPH-2-M5(-R) DPH-(-R) DPH--M(-R) DPH--M5(-R) EMC Directive, RoHS Directive Gauge pressure Rated pressure range 0.0 to +0.0 kpa 0 to +1.000 MPa 0 to 1.0 kpa Pressure withstandability 500 kpa 1.5 MPa 500 kpa Applicable fluid Supply voltage Current consumption Air, non-corrosive gas 12 to 24 V DC ± % Ripple P-P % or less 15 ma or less Ambient temperature 0 to +50 C +2 to +122 F (No dew condensation allowed), Storage: to +60 C +14 to +140 F Ambient humidity 5 to 85 % RH, Storage: 5 to 85 % RH Temperature characteristics Over ambient temperature range 0 to +50 C +2 to +122 F: within ±2 % F.S. of detected pressure at +25 C +77 F Material Cable Cable extension Weight Net weight Gross weight Type For compound pressure / vacuum pressure For positive pressure Item Model No. DPS-401 DPS-402 CE marking directive compliance Applicable sensor head Rated pressure range Display / set pressure range Supply voltage Power consumption (Note 2) Sensor head supply voltage Sensor head input Comparative outputs (Comparative output 1, 2) Output operation Hysteresis Repeatability Response time EMC Directive, RoHS Directive Compound pressure : DPH-1 Positive pressure : DPH-2 Vacuum pressure : DPH- Compound pressure: 0.0 to +0.0 kpa Positive pressure: 0 to +1.000 MPa Vacuum pressure: 0 to 1.0 kpa Compound pressure: 199.9 to +199.9 kpa Positive pressure: 1.050 to +1.050 MPa Vacuum pressure: +1. to 1. kpa 12 to 24 V DC ± % Ripple P-P % or less Normal operation: 650 mw or less (Current consumption 25 ma or less at 24 V supply voltage) ECO mode: 500 mw or less (Current consumption 20 ma or less at 24 V supply voltage) Same as supply voltage Input voltage range: 1 to 5 V DC (over rated pressure range) NP N open-collector transistor Maximum sink current: 50 ma (Note ) Applied voltage: 0 V DC or less (between comparative output and 0 V) Residual voltage: 1.5 V or less (Note 4) [at 50 ma (Note ) sink current] NO/NC, selectable by jog switch Minimum 0 digit, variable by hysteresis setting With compound pressure type connected: within ±0.2 % F.S. (±4 digits), With vacuum/positive pressure type connected: within ±0.2 % F.S. (±2 digits) 150 μs, 500 μs, 1 ms, 5 ms, ms, 50 ms, 0 ms, 500 ms, selectable by jog switch Ambient temperature to +50 C +14 to +122 F (cascading 8 to 16 controllers: to +45 C +14 to +1 F) (No dew condensation or icing allowed), Storage: 20 to +70 C 4 to +158 F Ambient humidity 5 to 85 % RH, Storage: 5 to 85 % RH Temperature characteristics Over ambient temperature range to +50 C +14 to +122 F: within ±0.5 % F.S. of pressure at +25 C +77 F Material Weight Enclosure: Heat-resistant ABS, Protective cover: Polycarbonate, Jog switch: ABS, MODE key: Acrylic Net weight: 20 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) Excluding current consumption of the applicable pressure sensor head. ) 25 ma max. if 5 or more controllers are connected together. 4) In case of using the quick-connection cable (cable length: 5 m 16.404 ft)(optional) 5) The cable for controller connection is not supplied as an accessory. Make sure to use the quick-connection cables (optional) given below. Main cable (4-core): CN-74-C1 (cable length: 1m.281 ft), CN-74-C2 (cable length: 2 m 6.562 ft), CN-74-C5 (cable length: 5 m 16.404 ft) Sub cable (2-core): CN-72-C1 (cable length: 1m.281 ft), CN-72-C2 (cable length: 2 m 6.562 ft), CN-72-C5 (cable length: 5 m 16.404 ft) 6) The values specified above are applied only to the controller. Front case: PBT, Rear case: PBT (glass fiber reinforced), Pressure port: Stainless steel (SUS0), O-ring: NBR Pressure element: Silicon diaphragm, PPS 0.2 mm 2 4-core oil resistant cabtyre cable (Models with -R affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable) Extension up to total m 2.808 ft is possible with 0.2 mm 2, or more, cable. DPH- (-R): Head g approx. / Cable 40 g approx., DPH- -M/M5(-R): Head 6 g approx. / Cable 40 g approx. DPH- (-R): 80 g approx., DPH- -M/M5(-R): 70 g approx. Accessory Connector (e-con): 1 pc. (Note 4) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +25 C +77 F. 2) The sensor head can be used independently. ) Model No. having the suffix -R is bending-resistant cable type. The bending-resistant cable type of DPH-2 is not available. 4) Connectors (e-con) are available as spare parts. CN-EP2: 5 pcs.

Dual Display Digital Pressure Sensor DPS-400 SERIES SERIES 750 I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Sensor head main circuit D2 1 kω ZD Sensor head internal circuit Terminal No. +V Model discrimination signal Analog voltage input 0 V Controller main circuit Tr2 D1 Tr1 Controller internal circuit Intermediate cable Terminal No. Color code of connector attached cable (Brown) +V (Note1) (Black) Comparative output 1 Load Load (White) ZD1 50 ma max.(note2) Comparative output 2 ZD2 (Blue) 0 V (Note1) 50 ma max.(note2) Users circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 25 ma max. if 5 or more controllers are connected together. ) Do not use the controllers in a series (AND) connection. Symbols D1, D2 : Reverse supply polarity protection diode ZD1 to ZD : Surge absorption zener diode Tr1, Tr2 : NPN output transister PRECAUTIONS FOR PROPER Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. The series is designed for use with air and non-corrosive gas. It cannot be used with liquid or corrosive and inflammable gases. 12 to 24 V DC ± % Wiring Make sure to use the optional quick-connection cable for the connection of the controller. Extension up to total 50 m 164.042 ft (cascading 9 to 16 controllers: 20 m 65.617 ft) is possible with 0. mm 2, or more, cable. However, in order to reduce noise, make the wiring as short as possible. Quick-connection cable side terminal arrangement diagram +V Comparative output 1 0 V Terminal No. Comparative output 2 Sensor head side terminal arrangement diagram Sensor head power supply 0 V Analog voltage input Model discrimination signal Refer to p.1566 for general precautions. Others Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (controller: 1 sec. approx., sensor head: 50 ms approx.) after the power supply is switched on. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained.

751 Dual Display Digital Pressure Sensor DPS-400 SERIES SERIES DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. DPS-401 DPS-402 Select 2 indicator (Yellow) Select 1 indicator (Yellow) Comparative output 1 operation indicator (Orange) Comparative output 2 operation indicator (Orange) 0.94 0 1.181 11 0.4 8.4 0.1 24 0.945 Suitable for 5 mm 1.78 in width DIN rail 58.7 0.85 2.11 1.215 2.7 0.6 Decimal point mark (Note1) Digital display (Green / Red) 12 0.472 75 2.95 27.8 Communication window 1.094 6.5 1.47 MODE key Jog switch 7 0.276.5 0.41.95 0.156 Controller MS-DIN-E 2.75 0.8 1.6 0.06 15 0.591 60 2.62 2 1.260 Material: Polycarbonate End plate (Optional) M (length 18 mm 0.709 in) pan head screws 24.7 0.972 5.6 M square nut 0.220 4 0.157 Suitable for 5 mm 1.78 in width DIN rail Note: Decimal points for pressure value. Above figure shows the DPS-401 (compound pressure / vacuum pressure). Positions of display and the pressure unit on the name plate for DPS-402 (positive pressure) differ from the above figure. CN-74-C1 CN-74-C2 CN-74-C5 Length L Model No. 2.65 0.4 Length L CN-74-C1 1,000 9.70 CN-74-C2 2,000 78.740 CN-74-C5 5,000 196.850 2.54 0.0 12 (.5 0.472) 0.41 2.54 0.0 0.2 0.008 7 0.276 0.94 1.6 0.55 Main cable (Optional) L ø. ø0.10 cable 14 ( 0.551) 2.9 ( ) 0.114 50 1.969 0.94 6 ( 0.26) 7.2 0.28 CN-72-C1 CN-72-C2 CN-72-C5 Length L Model No. Length L CN-72-C1 1,000 9.70 CN-72-C2 2,000 78.740 CN-72-C5 5,000 196.850 2.65 0.4 2.54 0.0 2.54 0.0 ( ) 12.5 0.472 0.41 0.2 0.008 7 0.276 0.94 1.6 0.55 L ø. ø0.10 cable 14 ( 0.551) 2.9 ( ) Sub cable (Optional) 0.114 50 1.969 0.94 6 ( 0.26) 7.2 0.28 DPH- (-R) Sensor head DPH- -M(-R) DPH- -M5(-R) Sensor head 1.2 0.520 R6.6 R0.260 6.6 0.260 ø8. ø0.27 14 0.55.94 9 0.54 2.4 0.921 Hexagonal hole (bolt width 5 0.197, 4 0.157 deep) R1/8 4.8 0.189 7 0.276 5 0.197 ø.7 ø0.146 cable, (2 m 6.562 ft / 5 m 16.404 ft long) 0.94 Model No. 14 0.5 0.551 0.020 A R5 R0.197 5 0.197 ø6.2 ø0.244 ø8.4 ø0.1 A 20.5 0.807 Hexagonal hole (bolt width,.5 0.18 deep) Gasket 4.8 0.189 7.8 0.07 6.6 0.260 ø.7 ø0.146 cable, 2 m 6.562 ft long DPH- -M(-R):M male thread DPH- -M5(-R):M5 male thread DPH- -M(-R).5 M5 female thread DPH- -M5(-R).5 0.18

Dual Display Digital Pressure Sensor DPS-400 SERIES SERIES 752 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. MS-DIN-2 8.5 5.2 0.5 0.205 0.4 0.016 ø1.8 ø0.071 7.5 4.2 0.295 0.165 2-ø.2 ø0.126 holes.2 0.126 21.6 0.850 16 0.60 5 2 1.78 0.079 2 0.079 27 1.06 5.2 0.205 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Controller mounting bracket (Optional).2 0.126 t 1 t 0.09 5 0.94 0.197