Max operation pressure 6kg/cm 2. Boost pressure rate Air pressure supply 5kg/cm Hydraulic fluid expelled l/min

Similar documents
Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

WORKHOLDING APPLICATION BOOKLET

OWNER S TECHNICAL MANUAL

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

Oil connector 3/8NPT. usable oil Air inlet pressure max. operating Air consumtion. oil capacity capacity min. max.

EXH. Specifications. Descriptions. Min. working pressure MPa

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

minibooster Hydraulics

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

HPB25 Hydraulic Paving Breaker

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Suitable for anyone who is required to maintain industrial pneumatic systems. No prior knowledge of pneumatic or electrical principles is necessary.

Direct Operated Precision Regulator Modular Style. Standard Specifications

Hydraulics. Hydraulic Pressure Control

DI-DRO ADVANCED FORMING SYSTEMS

Technical Data Sheet TI-F50 Locking Units series KFH

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Booster Regulator/Air Tank

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Unit 24: Applications of Pneumatics and Hydraulics

Air Operated Hydraulic Pumping Systems to 50,000 psi

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Axial piston pumps type PVC

Axial piston pumps type PVC

Hydraulic Reliability & Preventive Maintenance Report

Pilot Operated Check Valves Catalog Quick Reference

4/2 way Pneumatic Solenoid Valve

Series IRV1000/2000/3000

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

Directional valves Pneumatically operated Series CD07. Brochure

3-Way Safety Block DSV

Two-stage valve type NE

SPCH/ Blowing block

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Pressure reducing valve, pilot operated, Model 3DR

High flow rate. Cost effective. Compliant. Gripper with GSW-B Shaft Interface and Compensation Unit

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Safety and Shut-off Block SAF/DSV

Leak free Pipe Rupture Valve for Excavators

Hand lever valves VHER

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Air Amplifiers & SYSTEMS

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Product Information. Tolerance compensation unit TCU-Z

LMU100/200 Series. Standard Specifications

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

DI-DRO ADVANCED FORMING SYSTEMS

COSMO INSTRUMENTS CO., LTD.

Technical Data Sheet TI-F52 Locking Unit KFHL Certified by Lloyd s Register

Plant Air Energy Saving

[Graphic Division] 10

ALF400 to 900, ALT-5/-9

D62 - D63 Directional Control Valve l/min

Two-port valves, male threaded, PN25

Series VBA1110 to 4200

KFI Approved. High Pressure CO2 System Technical Datasheets

Pressure relief valves

Priority (Swing) Motors Data and Specifications

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Inverse Proportional Pressure-Relief Cartridge, Size 10

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Locking Units. Technical Information TI-F10. Locking by springs / releasing by pressure Types KFH, KFP and others

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

CK Series. 3-way jaw long stroke chuck double acting/single acting. Operational stroke length: 20, 40mm. Specifications. Switch specifications

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

ATM 322 Basic Pneumatics H.W.6 Modules 5 7

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

ANTI SHOCK RELIEF VALVE

Air preparation units

LPK1230 Hydraulic Crimping Tool 12 ton

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Wide opening parallel grippers Series CGLN

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

Introduction to Pneumatics

Gripping rotary modules

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

MAGANO WEITAI. MAGANO machinery manufacturing. professional manufacture booster regulator. Air amplifier/booster. air booster gas booster

Product Information. Gripper for small components MPG-plus 16

Pressure Sensing Valve - Model 4023

Power Valve: Precision Regulator. High precision, large capacity relief regulator

VACUUM REGULATORS CONTENTS

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Electro-Pneumatic Converter YT-940 SERIES

Transcription:

ADB Air Pump. Single Circuit Air Drive Booster Pmax:6kg/cm A ISO B P T Product Introduction The booster pump is driven by air to output hydraulic pressure for apower source for hydraulic cylinder. Its flow rate is bigger than that ofa conventional booter. Continuous pressure boosting and nolimitation of booster stroke for the acting cylinder. Pressure adjustment is made by an air pressure regulation valve.once pressure reaches the desired value, drive stops immediately. Incase pressure drops, the pump will compensate pressureautomatically. The series is especially ideal for long time hydraulicclamping application. Also features energy saving, no oil temperaturegrowth, economical and convenient. A Type: Equipped with ISO approved manifold and solenoid valve.applicable for single-acting or double-acting hydraulic cylinder. B Type: Equipped with pipe block with P.T ports, permitting forconnecting to a manual contort valve for operation control. Reduced oil tank volume for space saving and convenient installation. Specification Fluid Filtered air Max operation pressure 6kg/cm Boost pressure rate 6 1 44 Air pressure supply 5kg/cm 16 1 5 3 Hydraulic fluid expelled l/min Oil tank capacity 5 l Oil ISO-VG6 Order Code ADB- A - B - AC11V - MBRV 1 3 4 5 6 1 3 4 5 6 Series Boost pressure rate Control type Direction change valve type Coil type Quantity of pressure reduving valve A B ADB 6 1 44 ISO Manifold, magnet valve P.T Distributing tube seat P.T. port Single Head : B- Double Head : D- 3C- AC11V ACV DC4V MBRV-P TAIWAN AMAC CLAMP INDUSTRIAL CO., LTD. TEL:6-4-15 11 FAX:6-4-15

ADB Air Pump. Single Circuit Air Drive Booster Pmax:6kg/cm (311) 5 1 ISO-VG6,, (36) 345,,,,, 16 Ø9-3 holes at back & bottom,,, Notice 3 Use ISO-VG6 hydraulic oil. Be sure to fill proper amount of hydraulic oil into the oil tank before operation. Periodically inspect hydraulic oil quality to prevent affection on normal operation and parts life. In case air system can t work, remove the air valve but do not break down. Use an air gan to clean the internal direction change ports. There is a thin type bronze silencer on the aluminum body of air cylinder. If it is blocked by suction of powder dust, it may impede the motion of the piston of air cylinder. When such problem occurs, remove it for cleaning or replacing. If air system works continuously, but hydraulic pressure can t boost, it means oil seal is damaged causing internal leakage. TAIWAN AMAC CLAMP INDUSTRIAL CO., LTD. TEL:6-4-15 11 FAX:6-4-15

ADB Air Pump. Three Circuit Air Drive Booster Pmax:6kg/cm P MBRV-P EP-FA PS-1: ~kg PS-: 5~kgg Product Introduction The body of the booster cylinder has the same actuating function as the single circuit. The output hydraulic pressure includes three circuit. The P port on each circuit is equipped with a single direction valve, so that each circuit can work individually. It is applicable for automated clamp in multi-circuit, which can independently control hydraulic cylinder of clamp. Optional Accessories: Modular pressure reducing valve MBRV-P Fluid level switch in oil tank EP-FA Pressure sensor PS-1: ~kg PS-: 5~kg Specification Fluid Filtered air Max operation pressure 6 kg/cm Boost pressure rate 6 1 44 Air pressure supply 5kg/cm 16 1 5 3 Hydraulic fluid expelled l/min Oil tank capacity 1 l Oil ISO-VG6 Order Code ADB- A3 - B - AC11V - MBRV 1 3 4 5 6 1 3 4 5 6 Series Boost pressure rate Control type Direction change valve type Coil type Quantity of pressure reduving valve ADB 6 1 44 ISO Three-circuit manifold plate with ISO specification. Single Head : B- Double Head : D- 3C- AC11V ACV DC4V MBRV1 MBRV MBRV3 A, A3 Remark: A two circuits and A3 three circuits that commonly use an oil tank and manifold plate. TAIWAN AMAC CLAMP INDUSTRIAL CO., LTD. TEL:6-4-15 11 FAX:6-4-15

5 5 5 1 1 1 ADB Air Pump. Three Circuit Air Drive Booster Pmax:6kg/cm 35 (41) 5 (463) 35 (41) 1 33 13 4 35 4-Ø9~13x33 holes at back & bottom 33 13 33 4-Ø9~13x33 holes at back & bottom 33 TAIWAN AMAC CLAMP INDUSTRIAL CO., LTD. TEL:6-4-15 11 FAX:6-4-15

ADB Air Pump. Four Circuit Air Drive Booster Pmax:6kg/cm P MBRV-P EP-FA PS-1: ~kg PS-: 5~kg Product Introduction The body of the booster cylinder has the same actuating function as the single circuit. The output hydraulic pressure includes four circuit. The P port on each circuit is equipped with a single direction valve, so that each circuit can work individually. It is applicable for automated clamp in multi-circuit, which can independently control hydraulic cylinder of clamp. Optional Accessories: Modular pressure reducing valve MBRV-P Fluid level switch in oil tank EP-FA Pressure sensor PS-1: ~kg PS-: 5~kg Specification Fluid Filtered air Max operation pressure 6 kg/cm Boost pressure rate 6 1 44 Air pressure supply 5kg/cm 16 1 5 3 Hydraulic fluid expelled l/min Oil tank capacity 1 l Oil ISO-VG6 Order Code ADB- A4 - B - DC4V - MBRV 1 3 4 5 6 1 3 4 5 6 Series Boost pressure rate Control type Direction change valve type Coil type Quantity of pressure reduving valve ADB 6 1 44 ISO Four-circuit manifold plate with ISO specification. Single Head : B- Double Head : D- 3C- AC11V ACV DC4V MBRV1 MBRV MBRV3 MBRV4 TAIWAN AMAC CLAMP INDUSTRIAL CO., LTD. TEL:6-4-15 11 FAX:6-4-15

5 5 1 ADB Air Drive Booster Air Pump. Four Circuit Pmax:6kg/cm 4 (46) 1 5 5 1 (463) 33 13 4-Ø9~13x3 holes at back & bottom 3 TAIWAN AMAC CLAMP INDUSTRIAL CO., LTD. TEL:6-4-15 11 FAX:6-4-15