Flow divider designs MTL

Similar documents
Operating instructions spare parts list gear-flow-divider MTO

Multi-chambered volume synchroniser Type MZB

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Axial piston pumps type PVC

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Axial piston pumps type PVC

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

PLD 03 T A CASAPPA S.p.A.

Fixed Displacement Motor A4FM

Priority (Swing) Motors Data and Specifications

Fixed Displacement Plug-In Motor A2FE

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

Proper Pump Installation Practices

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

Fixed Displacement Motor A4FM

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Liquid ring vacuum pumps in compact design

Hydro-Pneumatic Cylinder HPL-B / HPL-C

Leak free Pipe Rupture Valve for Excavators

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Air Operated Hydraulic Pumping Systems to 50,000 psi

Leak-Free Load-Control Valve SAE ½ psi flange

WORKHOLDING APPLICATION BOOKLET

Hydraulic Reliability & Preventive Maintenance Report

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

OMS Technical Information. Versions OMS. Versions

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Variable Displacement Pump A10VO

Industrial Hydraulic Pumps T6EDC. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

Flow Dividers Type FD

OWNER S TECHNICAL MANUAL

OMS, OMT and OMV Orbital Motors. Technical Information

Accessories. Valves. Adjustable Pressure Relief Valves

D62 - D63 Directional Control Valve l/min

Proportional Valve Group PVG 32 minibooster

Monoblock Directional Control Valve RMB 202

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Liquid ring vacuum pumps in compact design

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Controllers DR, DP, FR and DFR

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Accessories. Valves. Adjustable Pressure Relief Valves

SIHI LPH-X - Liquid Ring Compressors

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

OMS Technical Information Technical data

OMS, OMT and OMV Orbital Motors. Technical Information

GEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM

Plant, components and devices for very high and high pressures (7000 bar and over)

Liquid ring vacuum pumps in compact design

Orbital Motors Type VMP. Technical Information

RP series Rotor Pumps

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

EC type-examination certificate UK/0126/0065 Revision 1

(AS AT 31 st MARCH, 2002)

09 - Choosing /sizing a cylinder and valve

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Liquid ring compressors

Orbital Motors Type OMP, OMR and OMH. Technical Information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Introduction to Pumps

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Liquid ring vacuum pumps single-stage

InnovDos Foam proportioning system

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motor VMP. powersolutions.danfoss.com

Pressure on Demand. Air Pressure Amplifiers

InnoVfoam B.V. InnovDos Foam Proportioning System

Pressure reducing valve, pilot operated

Unit 24: Applications of Pneumatics and Hydraulics

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Elevator Concepts ltd. by Wurtec Krause Riverview, MI Fax:

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Leak-Free Load-Control Valve, Size 20

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Liquid ring compressor

Check valve hydraulically pilot operated

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Air Amplifiers & SYSTEMS

Unit 24: Applications of Pneumatics and Hydraulics

Series/Parallel Pumps Bench PBSPB

Max operation pressure 6kg/cm 2. Boost pressure rate Air pressure supply 5kg/cm Hydraulic fluid expelled l/min

PVK OPEN LOOP PUMPS. Bulletin E

Lesson 6: Flow Control Valves

AIR/OIL BOOSTER APPLICATIONS TECHNICAL DATA

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Orbital Motors OMS, OMT and OMV

Orbital Motors Type OMP X and OMR X

Transcription:

H Y D R A U L I K Flow divider designs MTL Edition November 1999/2005 Jahns-Regulatoren GmbH D 63069 Offenbach Sprendlinger Landstraße 150 Telephon (069) 83 10 86 D 63009 Offenbach Postbox 10 09 52 Telefax (069) 83 70 59 www.jahns-hydraulik.de info@jahns-hydraulik.de

Contents Flow-divider-applications Synchronised running... 3 Pressure multipliers... 3 Lubricating-oil flow divider... 3 Synchronisation differences... 4 Internal pressure-drop... 4 Means of overcoming the pressure-drop... 4 Using a driver... 5 Compensating synchronisation-errors... 5 Minimum flows... 5 Flow-divider start-up... 6 Use flow dividers in special conditions... 6 Synchronisation ratios... 6 Synchronisation errors due to differnt oil-compression... 6 Noise-levels... 6 Inlet/outlet-blocks... 6 Use of other fluids than mineraloil... 6 How to install the flow divider, start-up... 7 Gear-flow-divider, high-pressure version... 7 Volume-synchronisation-cylinder... 7 Technical datas, dimensions Series MTL, for 2 up to 12 sections Radial-piston flow divider MTL-../29 up to MTL-../270... 8, 9 Radial-piston flow divider MTL-../29 up to MTL-../270 with i/o-block... 10, 11 Jahns Regulatoren GmbH 1995, 1997, 1999, 2005 Reprinting, even partially, not permitted. No responsibility for possible errors in catalogues or other printed material is accepted. Former catalogues lost their validity. Catalogues are subject to be changed. Page 2

Flow divider application Synchronised running If several motors or cylinders are operate from a single pump without any means of controlling their individual flows only the motor or cylinder with the lowest pressure requirement would start its work cycle. The motor or cylinder with the next lowest pressure requirement would only start when the first unit has completed its work cycle. This mode of operation is generally undesirable and it is therefore necessary for the total pump flow to be divided into a series of partia flows.this can be achieved in the following ways: Throttles or flow regulation valves in each of the motor or cylinders connections. Oprerating the units in a series circuit. With flow divider valves for 2 sections. With flow dividers of various designs. Jahns flow dividers are of the rotating motor type and offer, indipendently of their design, the following synchronisation advantages: High degree of synchronisation even with the simpler gear-motor flow dividers. al sction displacements in order to achieve high pressure multiplication ratios. The pressure values in the example diagramm below are indicative of an MT. The theoretical output pressure value of approx. 400 bar will be lower due to effiency losses. It should be noted that the pressure gain achievedis made possible through an increase in system flow. This type of hydraulic circuit can be used where a low pressure circuit is already in use and where there is only need of s small high pressure flow. The installation of a supplementary high pressure circuit with pump, electric motor, pressure relief valve and manometer would not be convient in this case as it would be possible to utilise the existing low pressure circuit. p HP = 265 bar High degree of synchronisation is maintained over a wide range of flows. Due to low leakage rates in the individual section the high degree of synchronisation is maintained with differing load conditions. The use of flow dividers is not complicated if applied withan appropriate hydraulic circuit design. Additional installation alterations are not necessary. For applications, where only a lower degree of synchronisation is necessary, Jahns offers flow divider valves, too. These valves are a very economic alternative. Q HP = 20 l/min V 1 = 115 cm³/rev Q Input = 82 l/min p Input = 100 bar Q LP = 60 l/min V 2 = 350 cm³/rev Pressure multipliers As mentioned earlier as well as operating as a synchronising instrument the flow divider can be utilised as a pressure multiplier. The entire range of gear-motor flow dividers can be used for this type of application and due their low internal pressure losses and low cost they often represent the optimal solution. The MT series is suitable when the requiered output pressure exceeds 300 bar. It is possible, on request, to provide special units when a large difference in individu- Lubricating-oil flow divider Shafts with multiple sets of friction bearings require a sure supply of lubrificating oil in equal quantities to each of the bearings. With the gear-motor flow dividers, that do not have any external leakages, if the gear of one of the sections are turning then a synchronised flow in all the other sections is ensured. It is therefore only necessary to check the speed of on of the shafts with anelectronic sensor and Jahns can be supply the component required for this solution. Page 3

Flow divider application Synchronisation differences With particular reference to the gear-motor flow dividers MTZ but also for the radial-motor flow dividers MT and MTL synchronisation differences depend on the following parameters: Oil viscosity and temperature Pressure load varability System pressure levels Total flow rate to be divided Precise indications of synchronisation levels are only possible if the details of all the above parameters are known. A general indication may be obtained from the following values: MK synchronisation tollerances ± 4,0 up to ± 5,0 % MTZ synchronisation tollerances ± 1,5 up to ± 2,5 % MT synchronisation tollerances ± 0,7 up to ± 0,9 % MTL synchronisation tollerances ± 0,4 up to ± 0,8 % Jahns is able to carry out test-bench simulations of specified working conditions in order to determine the synchronisation levels of a customer's particular application. In this way it is possible for the customer to avoid incorporating large safety margins in the design. Internal pressure drop in flow divider valve You find the datas in the diagrams on page 8. Internal pressure drop in gear-motor flow dividers This factor is relatively insignificant in gear-flow dividers. The smallest models MTZ-..24 have pressure drops of 15-18 bar, the next size MTZ-..48 of approx. 13 bar and all larger sizes of 11-12 bar. Internal pressure drop in radial-piston flow dividers The radial piston motor design has larger pressure drops than the gear motor design and the pressure drop also depend on the outlet pressure. The following of the outlet pressure for all MT an MTL models: Required Input Pressure output pressure pressure drop p o (bar) p i (bar) p (bar) 50 60 10 60 75 15 80 100 20 90 110 20 100 120 20 110 140 30 120 150 30 130 160 30 140 175 35 150 190 40 160 200 40 170 210 40 180 225 45 190 240 50 200 250 50 210 265 55 230 285 55 Pressure drop in radial-piston flow-dividers MT and MTL Means of overcoming the disadvantage of pressure drop Often for cylinders the high pressure is only required in one flow direction. The flow divider can be built into the return line were the pressure is much lower. In several applications synchronisation is not required during the high pressure phase of the work cycle, for example, in a 2 cylinder press synchronisation is only needed when the cylinders are working at low pressure. During the high pressure phase of the work cycle the flow divider can be by-passed using check valves. Page 4

Flow divider application Using a driver This is achieved by adding an extra section of equal or greater displacement to the flow divider. The return line of this section is connected directly to tank so that it in effect works as a motor for the other sections in the flow divider thereby increasing their outlet pressures. This is useful, for example, in lifting platforms that should lower under action of their own weight, but where the weight of the empty platform is insufficient for this to occur. Compensating synchronisation errors - installation of the flow divider in the hydraulic circuit excess pressure in the cylinder outlet lines as may be caused by the pressure multiplier effect. In this way all cylinders are able to complete their strokes even if one of them has reached the stroke-end. Valves 2 and 3 maintain a minimum pressure of approx. 4 bar in each of the flow divider sections. The difference of 1 bar from the opening tension of valve 3 is due to the opening tension of valves 2 of 1 bar. The minimum pressure feed is important, for example, when one of the cylinder has reached its end stroke, but the flow divider continues running due to the slower cylinders. The pressure feed then prevents suction occuring in the line connecting the fastest cylinder. Valve 4 has an important function which is often ignored on flow dividers: If the oil flow from the pump reaches the cylinders and the flow divider has the task of collection the returnline oil in order to perform an equalisation of the flows, valve 4 ensures that the flow divider is not made to run at the speed of the fastest cylinder hen the other cylinders do not follow due to friction, loading, pinching etc.: the flow divider can only operate as a collector if all the cylinders operate at the same speed. A pressure relief valve or an over-centre valve could be used instead of the throttle valve 4. The use of such a valve in the circuit becomes particularly important when the cylinder return strokes occur whitout a controlling pump flow, eg. under action of their own weight. Minimum flows The gear-motor flow dividers in particular are not low speed components. Generally the minimum flows per section are as follows: MTZ-..24 : Qmin = 2 l/min MTZ-..48 : Qmin = 1.5 l/min As the low divider is an independent flow control mechanism without any direct means of measuring the synchronisations errors that will always occur, any corrections have to take place as the cylinders reach the end of their stroke. The diagramm below shows an example of such a circuit. The valves in the circuit have the following functions: The pressure relief valves 1 serve as protection against MTZ-..M11 : Qmin = 2.5 l/min MTZ-..M26 : Qmin = 7 l/min MTZ-..36 : Qmin = 10 l/min MTZ-..51 : Qmin = 13 l/min MT : Qmin =0.15 x Qmax MTL : Qmin =0.25 x Qmax Page 5

Flow divider application Flow divider start-up The smallest flow dividers in particular do not start if there is already a high outlet pressure at the beginning of the cycle. This situation occurs, for example, with the flow divider installed between the pump and cylinders, when the lifting of a load is stopped and held by pressure in the flow divider outlet. In this case it is possible to use check valves to hold the load while the flow divider outlets are relieved of pressure. Depending on the type of application a variety of solutions are possible; it is merely a question of taking this into consideration when designing the circuit. Use of flow dividers in special conditions If the use of a flow divider is beeing considered, but it is not clear whether it will be suitable for the application, we recommend that you contact us and if possible send us the diagram of the proposed hydraulic circuit. The many years of experience of working together with our cliensts in the field of flow divider applications enables us to expertly evalate any application. Synchronisation ratios In general, the synchronisation ratio required is 1:1. Different ratios are possible on request. If so, please contact Jahns technical staff. Obtaining different ratios is made easier if it is possible to obtain the required section displacement difference in the same section housing. Noise-levels Specially the gear-motor flow dividers cause a noiselevel running over 1800 rpm that can not always be accepted. Please choice the displacement according to this fact. Inlet / outlet-blocks To achieve a minimum of piping and fittings and to guarantee the proved quality of important valves for the hydraulic circuit, you can get from Jahns so called inlet/ outlet blocks for MTZ, MT and MTL flow divider. They have to be ordered directly together with the flow dividers, because a later assembly is generally impossible or causes problems. The blocks for the MT series are not separated into inlet/outlet ports, but integrated in one block only. The present outlet-blocks have a relief-valve for each section and a separate port to measure the pressure. The pressure a setting should be done, when the cylinder are in the external stroke-end. The pressuresetting should be 20 bar over the pressure to lift the cylinder with their charge. The port NS, T should be coneccted with the return-line. This return-line should have a pretension of 3-5 bar. Use of other fluids than mineraloil Specially the radial-piston flow dividers, but the flowdivider valves, too, accept other fluids than mineraloil, such as HFC, HFD, non-contaminating fluids. Please contact Jahns in those cases. Synchronisation errors due to differing oil compression The flow divider is not able to compensate for errors due to differing oil compression caused by differing cylinder loads. It is advisable to minimise oil volumes between the flow divider and the cylinder by using short tubes of equal length for all cylinders. If the difference in load in the cylinders is unchanging then it is possible to correect or eliminate oil compression synchronisaton errors with the appropriate use of pressure relief valves. Page 6

Flow divider application How to install the flow divider, start-up The use of MK-valves afford a horizontal assembly only. There are no further details to look for. Gear-motor flow-dividers have no drain-line connection and, consequently, are not subject of prefilling. The MT-series require a drain-line connection to both sides. Max. drain-pressure is 1,5 bar. Radial-piston flow-dividers series MTL have a drainline connection on both end-sides. It's sufficient to connect only one drain-line, because the drains of the sections are connected internally. Max. drain-pressure is 10 bar (1,5 bar only for items with external shaft f. e. to measure the flow by the speed). Drain-line piping is to be installed in a way that it! cannot get empty. Due to the low quantity of drain it is necessary to fill the radial-piston flow-dividers complete before the first start. Otherwise the flow-divider has to run a long time with dry shaft and bearings. Specially this important detail is often forgoten even by skilled personal. Periods to change oil and filter: according to the recommendation of their suppliers. Page 7

Radial piston flow divider MTL Displacement Flow per section Pressure Max. power per section continuous intermittend continuous intermittend per section Type (cm³/rev) (l/min) (l/min) (bar) (bar) (kw) MTL../ 29 30,2 28 40 240 300 14 MTL../ 42 42,7 45 65 240 300 20 MTL../ 70 69,9 63 90 240 300 30 MTL../ 108 108,4 95 135 240 300 45 MTL../ 170 170,9 110 160 240 300 55 MTL../ 270 271,4 175 250 240 300 75 Complete drawings of the series MTL-2/29 to MTL-12/270 of different sizes are available upon request. Order codes Example: MTL-4/29-EA G Threated connection E Inlet block, see pages 26, 27 A Outlet block, see pages 26, 27 29 Displacement of each section 4 Number of sections MTL../ 29 MTL../ 42 Connections A1 to A4 or B1 to B4 G3/4" Input, to be connected together B1 to B4 or A1 to A4 G3/4" Output, section-flows L G1/2" Drain-ports, drain pressure max. 10 bar Feet can be placed from 130 mm The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a difference of 130 mm each section. Weight: MTL-../29-G and MTL-../42-G 30 kg/section Page 8

Radial piston flow divider MTL Connections A1 to A4 or B1 to B4 G1 1/4" Input, to be connected together B1 to B4 or A1 to A4 G1 1/4" Output, section-flows L G3/4" Drain-ports, drain pressure max. 10 bar MTL../ 70 MTL../ 108 Feet can be placed from 155 mm The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a difference of 155 mm each section. Weight: MTL-../70-G and MTL-../108-G 48 kg/section Connections A1 to A4 or B1 to B4 G1 1/2" Input, to be connected together B1 to B4 or A1 to A4 G1 1/2" Output, section-flows L G3/4" Drain-ports, drain pressure max. 10 bar MTL../ 170 MTL../ 270 Feet can be placed from 225 mm The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a difference of 225 mm each section. Weight: MTL-../170-G and MTL-../270-G 120 kg/section Page 9

Radial piston flow divider MTL with EA valve block Displacement Flow per section Pressure Max. power per section continuous intermittend continuous intermittend per section Type (cm³/rev) (l/min) (l/min) (bar) (bar) (kw) MTL../ 29 30,2 28 40 240 300 14 MTL../ 42 42,7 45 65 240 300 20 MTL../ 70 69,9 63 90 240 300 30 MTL../ 108 108,4 95 135 240 300 45 MTL../ 170 170,9 110 160 240 300 55 MTL../ 270 271,4 175 250 240 300 75 Complete drawings of the series MTL-2/29 to MTL-12/270 of different sizes are available upon request. Order codes Example: MTL-4/29-EA G Threated connection, see pages 24, 25 E Inlet block A Outlet block 29 Displacement of each section 4 Number of sections MTL../29-EA MTL../42-EA Connections E G1 1/4" Input A1 to A4 G3/4" Output, divided flows L G3/4" Drain port, drain-pressure max. 10 bar T, NS G3/8" Tank and low-pressure-feeding M1 to M4 G1/4" Measuring port for each section Circuit according DIN ISO 1219 Feet can be placed from 130 mm The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a difference of 130 mm each section. Weight: MTL-../29-EA and MTL-../42-EA 36 kg/section Page 10

Radial piston flow divider MTL with EA valve block Connections E G1 1/2" Input A1 to A4 G1 1/4" Output, divided flows L G3/4" Drain port, drain-pressure max. 10 bar T, NS G3/4" Tank and low-pressure-feeding M1 to M4 G1/4" Measuring port for each section MTL../ 70-EA MTL../108-EA Feet can be placed from 155 mm The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a difference of 155 mm each section. Weight: MTL-../70-EA and MTL-../108-EA 74 kg/section Connections E G2" Input A1 to A4 G1 1/4" Output, divided flows L G3/4" Drain port, drain-pressure max. 10 bar T, NS G3/4" Tank and low-pressure-feeding M1 to M4 G1/4" Measuring port for each section Circuit according DIN ISO 1219 MTL../170-EA MTL../270-EA Feet can be placed from 225 mm The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a difference of 225 mm each section. Weight: MTL-../170-EA and MTL-../270-EA 167 kg/section Page 11

Komponenten für Hydraulik und Verfahrenstechnik Jahns-Regulatoren GmbH Hausanschrift: Postfach 10 09 52 Sprendlinger Landstraße 150 http://www.jahns-hydraulik.de D 63009 Offenbach D 63069 Offenbach info@jahns-hydraulik.de Telefon +49/(0)69/84 84 77-0 Telefax +49/(0)69/84 84 77 25