Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Similar documents
Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

1 Technical specifications

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

1 Technical specifications

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

1 Technical specifications

Siemens AG Span (min... max.) Max. perm. test. 87 psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar)

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

1 Overview. Pressure Measurement Transmitters for general requirements. SITRANS P DS III - Technical description

TYPE APPROVAL CERTIFICATE

SITRANS P measuring instruments for pressure

Pressure Measurement. Transmitters for general requirements SITRANS P DS III Technical description. 2/74 Siemens FI

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement Single-range transmitters for general applications

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Siemens AG Transmitters with WirelessHART 1/42 SITRANS P280 for gauge and abs. pressure. Transmitters for food, pharmaceuticals

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Pressure transmitter PASCAL Ci4

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Multi Vision. Digital Transmitter 10/ EN

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

9700 Transmitter Submersible hydrostatic level transmitter

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Pressure Measurement Transmitters for food, pharmaceuticals and biotechnology

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

OPTIBAR P 1010 C Technical Datasheet

ATM.1ST/Ex - High Precision Transmitter

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Model 261GR for gauge pressure Model 261AR for absolute pressure

Flow Measurement SITRANS F X

Pressure transmitters EMP 2

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

1 Overview. Pressure Measurement Transmitters for food, pharmaceuticals and biotechnology. SITRANS P300 for gauge and absolute pressure

Model 266MST Differential Model 266RST Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

Torque Tube TB300 Digital Transmitters

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

ATM/Ex - Analog Pressure Transmitter

Differential pressure

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

2600T Series Pressure Transmitter

Bourdon tube pressure gauge for diaphragm seals

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Precision digital pressure gauge Model CPG1000

1 Overview. Pressure Measurement Remote seals for transmitters and pressure gauges SITRANS P320/P420. 1/352 Siemens FI US Edition

SITRANS P measuring instruments for pressure

Model 266HSH Gauge Model 266NSH Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Model 266MST Differential Model 266RST Absolute. 2600T Series Pressure Transmitters. Engineered solutions for all applications

Precision pressure sensor Basic version Model CPT6020

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

Pressure Measurement. Transmitters for food, pharmaceuticals and biotechnology. SITRANS P300 for gauge and absolute pressure. 2/34 Siemens FI

Hand-held pressure calibrator with integrated pump Model CPH6600

Technical Data. Dimensions

Differential Pressure Transmiter

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure switch with bourdon tube

ABB measurement & analytics data sheet. 266MST and 266RST Differential and absolute pressure transmitters

SITRANS P measuring instruments for pressure

Model 266HSH Gauge Model 266NSH Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

High-speed pressure sensor Model CPT6140

Pressure Measurement

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

ATM - Analog Pressure Transmitter

ED 701 Hygenic Pressure Transmitter

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Technical Data. Dimensions

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

High-performance submersible pressure transmitter For level measurement Model LH-10

Model 266GST Gauge Model 266AST Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

ATM.ECO - Analog Pressure Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-20

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Additel 780 Series Pressure Controller

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. Dimensions

Design Features. General Description

High-performance submersible pressure transmitter For level measurement Model LH-20

UNIK 5600/5700. Marine Certified Pressure Sensing Platform. High Quality. Features. Bespoke as Standard. Expertise. bhge.com

Technical Data. Dimensions

Sales presentation. SITRANS P portfolio extension P310 P DS III P410

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Programmable pressure and temperature transmitters PTM/RS485

Transcription:

Siemens AG 207 Technical specifications SITRANS P DS III series for absolute pressure (from the gauge pressure series) Input Measured variable Absolute pressure Span (fully adjustable) or measuring range, max. operating pressure (in accordance with 204/68/EU Pressure Equipment Directive) and max. test pressure (pursuant to DIN 6086) HART PROFIBUS PA/ FOUNDATION Fieldbus Span Nominal measuring range Lower measuring limit Measuring cell with silicone oil filling Measuring cell with inert filling liquid - for process temperature -20 C < ϑ +60 C (-4 F < ϑ +40 F) - for process temperature 60 C < ϑ +00 C (max. 85 C for measuring cell 30 bar) (40 F < ϑ +22 F (max. 85 F for measuring cell 435 psi)) 8.3... 250 mbar a 0.83... 25 kpa a 3... 00 inh 2 O a 43... 300 mbar a 4.3... 30 kpa a 7... 525 inh 2 O a 60... 5000 mbar a 6... 500 kpa a 2.32... 72.5 psia... 30 bar a 0.... 3 MPa a 4.5... 435 psia 5,3... 60 bar a 0.53... 6 MPa a 76.9... 232 psia 3.3... 400 bar a.3... 40 MPa a 92.9... 5802 psia 23.3... 700 bar a 2.33... 70 MPa a 338... 053 psia 0 mbar a/0 kpa a/0 psia 250 mbar a 25 kpa a 00 inh 2 O a 300 mbar a 30 kpa a 525 inh 2 O a 5000 mbar a 500 kpa a 72.5 psia 30 bar a 3 MPa a 435 psia 60 bar a 6 MPa a 232 psi 400 bar a 40 MPa a 5802 psia 700 bar a 70 MPa a 053 psia 30 mbar a/3 kpa a/0.44 psia 30 mbar a + 20 mbar a. (ϑ - 60 C)/ C 3 kpa a + 2 kpa a. (ϑ - 60 C)/ C 0.44 psi a + 0.29 psi a. (ϑ - 40 F)/ F Max. operating pressure MAWP (PS).5 bar a 50 kpa a 2.8 psia 2.6 bar a 260 kpa a 37.7 psia 0 bar a MPa a 45 psia 45 bar a 4.5 MPa a 653 psia 67 bar a 6,7 MPa a 2422 psi 400 bar a 40 MPa a 5802 psia 800 bar a 80 MPa a 603 psia Max. perm. test pressure 6bar a 600 kpa a 87 psia 0 bar a MPa a 45 psia 30 bar a 3 MPa a 435 psia 00 bar a 0 MPa a 450 psia 250 bar a 25 MPa a 3626 psi 600 bar a 60 MPa a 8702 psia 800 bar a 80 MPa a 603 psia Upper measuring limit 00 % of max. span (for oxygen measurement max. 00 bar/0 MPa/450 psi and 60 C (40 F) ambient temperature/process temperature) Start of scale value Between the measuring limits (fully adjustable) Output HART PROFIBUS PA/FOUNDATION Fieldbus Output signal 4... 20 ma Digital PROFIBUS PA and FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 23 ma, factory preset to 20.5 ma or - optionally set to 22.0 ma Load Without HART R B (U H - 0.5 V)/0.023 A in Ω, - U H : Power supply in V With HART R B = 230... 500 Ω (SIMATIC PDM) or - R B = 230... 00 Ω (HART Communicator) Physical bus - IEC 658-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Electrical damping (step width 0. s) Set to 2 s (0... 00 s) Siemens FI 0 207 US Edition /4

Siemens AG 207 SITRANS P DS III series for absolute pressure (from the gauge pressure series) Measuring accuracy Acc. to IEC 60770- Reference conditions (All error data refer always refer to the set span) Increasing characteristic Start-of-scale value 0 bar/kpa/psi Stainless steel seal diaphragm Silicone oil filling Room temperature 25 C (77 F) Measuring span ratio r (spread, Turn-Down) r = max. measuring span/set measuring span or nom. pressure range Error in measurement at limit setting incl. hysteresis and reproducibility Linear characteristic -r 0 0. % - 0 < r 30 0.2 % Influence of ambient temperature (in percent per 28 C (50 F)) 250 mbar a/25 kpa a/3.6 psia (0.5 r + 0.) % 300 mbar a/30 kpa a/8.8 psia (0.08 r + 0.6) % 5 bar a/500 kpa a/72.5 psia 30 bar a/3000 kpa a/435 psia 00 bar a/0 MPa a/450 psia 60 bar a/6 MPa a/232 psia 400 bar a/40 MPa a/5802 psia 700 bar a/50 MPa a/052 psia Long-term stability (temperature change ± 30 C (± 54 F)) (0.25 r) % in 5 years Effect of mounting position (in pressure per change in angle) 0.05 mbar/0.005 kpa/0.000725 psi per 0 inclination (zero point correction is possible with position error compensation) Effect of auxiliary power supply 0.005 % per V (in percent per change in voltage) Measuring value resolution for PROFIBUS PA and 3 0-5 of nominal measuring range FOUNDATION Fieldbus Rated conditions Degree of protection (to IEC 60529) IP66 (optional IP66/IP68), NEMA 4X Temperature of medium Measuring cell with silicone oil filling -40... +00 C (-40... +22 F) -20... +00 C (-4... +22 F) with 30 bar a measuring cell Measuring cell with inert filling liquid -20... +00 C (-4... +22 F) In conjunction with dust explosion protection -20... +60 C (-4... +40 F) Ambient conditions Ambient temperature - Transmitter -40... +85 C (-40... +85 F) - Display readable -30... +85 C (-22... +85 F) Storage temperature -50... +85 C (-58... +85 F) Climatic class - Condensation Relative humidity 0... 00 % Condensation permissible, suitable for use in the tropics Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 6326 and NAMUR NE 2 /42 Siemens FI 0 207 US Edition

Siemens AG 207 SITRANS P DS III series for absolute pressure (from the gauge pressure series) Design Weight (without options).5 kg ( 3.3 lb) Enclosure material Low-copper die-cast aluminum, GD-AlSi 2 or stainless steel precision casting, mat. no..4408 Wetted parts materials Connection shank Stainless steel, mat. no..4404/36l or Hastelloy C4, mat. no. 2.4602 Oval flange Stainless steel, mat. no..4404/36l Seal diaphragm Stainless steel, mat. no..4404/36l or Hastelloy C276, mat. no. 2.489 Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxygen measurement pressure 00 bar (450 psi) at 60 C (40 F)) Process connection Connection shank G½B to EN 837-, female thread ½ -4 NPT or oval flange (PN 60 (MAWP 2320 psia)) to DIN 923 with mounting thread M0 or 7 / 6-20 UNF to IEC 658/DIN EN 658 Material of mounting bracket Steel Sheet-steel, Mat. No..0330, chrome-plated Stainless steel Sheet stainless steel, mat. no..430 (SS 304) Power supply U H HART PROFIBUS PA/FOUNDATION Fieldbus Terminal voltage on transmitter 0.5... 45 V DC - 0.5... 30 V DC in intrinsically-safe mode Power supply Supplied through bus Separate 24 V power supply necessary - No Bus voltage Not Ex - 9... 32 V With intrinsically-safe operation - 9... 24 V Current consumption Basic current (max.) - 2.5 ma Start-up current basic current - Yes Max. current in event of fault - 5.5 ma Fault disconnection electronics (FDE) available - Yes Siemens FI 0 207 US Edition /43

Siemens AG 207 SITRANS P DS III series for absolute pressure (from the gauge pressure series) Certificates and approvals HART PROFIBUS PA/ FOUNDATION Fieldbus Classification according to PED 204/68/EU For gases of fluid group and liquids of fluid group ; complies with requirements of article 4, paragraph 3 (sound engineering practice) Explosion protection Intrinsic safety "i" PTB 3 ATEX 2007 X - Marking Ex II /2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Permissible ambient temperature -40... +85 C (-40... +85 F) temperature class T4; -40... +70 C (-40... +58 F) temperature class T5; -40... +60 C (-40... +40 F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw; R i =300Ω FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.32 W Linear barrier: U o = 24 V, I o = 250 ma, P o =.2 W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 μh, C i =. nf Explosion-proof "d" PTB 99 ATEX 60 - Marking Ex II /2 G Ex d IIC T4/T6 Gb - Permissible ambient temperature -40... +85 C (-40... +85 F) temperature class T4; -40... +60 C (-40... +40 F) temperature class T6 - Connection To circuits with values: U H =0.5...45 V DC To circuits with values: U H = 9... 32 V DC Dust explosion protection for zone 20 PTB 0 ATEX 2055 - Marking Ex II D Ex ta IIIC T20 C Da Ex II /2 D Ex ta/tb IIIC T20 C Da/Db - Permissible ambient temperature -40... +85 C (-40... +85 F) - Max. surface temperature 20 C (248 F) - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw, R i = 300 Ω FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.32 W Linear barrier: U o = 24 V, I o = 250 ma, P o =.2 W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 μh, C i =. nf Dust explosion protection for zone 2/22 PTB 0 ATEX 2055 - Marking Ex II 2 D Ex tb IIIC T20 C Db - Connection To circuits with values: U H =0.5...45 V DC; P max =.2 W Type of protection "n" (zone 2) PTB 3 ATEX 2007 X - Marking Ex II 2/3 G Ex na II T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Connection (Ex na) U m = 45 V U m = 32 V - Connection (Ex ic) To circuits with values: U i = 45 V To circuits with values: U H =9...32 V DC; P max = W FISCO supply unit ic: U o = 7.5 V, I o = 570 ma Linear barrier: U o = 32 V, I o = 32 ma, P o = W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 μh, C i =. nf Explosion protection acc. to FM Certificate of Compliance 3008490 - Identification (XP/DIP) or (IS); (NI) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; CL I, ZN 0/ AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Explosion protection to CSA Certificate of Compliance 5365 - Identification (XP/DIP) or (IS) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III /44 Siemens FI 0 207 US Edition

Siemens AG 207 HART communication HART 230... 00 Ω Protocol HART Version 5.x Software for computer PROFIBUS PA communication Simultaneous communication with master class 2 (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks 2 Analog input - Adaptation to customer-specific process variables SIMATIC PDM 4 Configuration tool or local operation (standard setting address 26) 5 (one measured value) or 0 (two measured values) 0,, or 2 (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, class B Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0 to 00 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block Transducer blocks 2 Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container Max. 30 nodes characteristic with - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, function block PID Analog input - Adaptation to customer-specific process variables characteristic Yes, linearly rising or falling - Electrical damping, adjustable 0... 00 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FOUNDATION Fieldbus function block Physical block resource block Transducer blocks transducer block Pressure with calibration, transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function Siemens FI 0 207 US Edition /45

Siemens AG 207 Selection and Ordering data Article No. Pressure transmitters for absolute pressure from gauge pressure series SITRANS P DS III with HART 7 M F 4 2 3 3-7 7 7 7 7-7 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid ) grease-free to cleanliness level 2 3 Measuring span (min.... max.) 8.3... 250 mbar a (0.2... 3.62 psia) D 43... 300 mbar a (0.62... 8.85 psia) F 0.6... 5 bar a (2.32... 72.5 psia) G... 30 bar a (4.5... 435 psia) H 5,3... 60 bar a 2) (76.9... 2 32 psia) L 3,3... 400 bar a 2) (92.9... 5 802 psia) M 23,3... 700 bar a 2) (338... 0 53 psia) N Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Version for diaphragm seals in conjunction with Y process connector "female thread ½-4 NPT" (recommended version) 3) 4) 5) 6) 7) Version for diaphragm seals in conjunction Y 0 with process connector "G½B connection shank" 3) 4) 5) 6) 7) Process connection Connection shank G½B to EN 837-0 Female thread ½-4 NPT Stainless steel oval flange with process connection (Oval flange has no female thread) - Mounting thread 7 / 6-20 UNF to 2 IEC 658/DIN EN 658 - Mounting thread M0 to DIN 923 3 - Mounting thread M2 to DIN 923 4 Male thread M20 x.5 5 Male thread ½ -4 NPT 6 Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 8) 3 Version Standard version, German plate inscription, setting for pressure unit: bar International version, English plate inscription, 2 setting for pressure unit: bar Chinese version, English plate inscription, 3 setting for pressure unit: Pascal All versions include DVD with compact operating instructions in various EU languages. Explosion protection None A With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" B - "Explosion-proof (Ex d)" 9) D - "Intrinsic safety and flameproof enclosure" P (Ex ia + Ex d)" 0) - "Ex na/ic (Zone 2)" ) E - "Intrinsic safety, explosion-proof enclosure R and dust explosion protection (Ex ia+ Ex d + Zone D/2D)" 0)2) FM + CSA intrinsic safe (is) 3) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + S Zone D/2D 0)2)3) With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof N C (is + xp)" 9)3) Selection and Ordering data Article No. Pressure transmitters for absolute pressure 7 M F 4 2 3 3 - from gauge pressure series 7 7 7 7 7 SITRANS P DS III with HART - 7 7 7 7 Electrical connection/cable entry Screwed gland M20x.5 B Screwed gland ½-4 NPT C Han 7D plug (plastic housing) incl. mating D connector 4) M2 connectors (stainless steel) 5) 6) F Display Without display 0 Without visible display (display concealed, setting: ma) With visible display (setting: ma) 6 with customer-specific display (setting as 7 specified, Order code "Y2" or "Y22" required) Power supply units see Chap. 7 "Supplementary Components". A quick-start guide is included in the scope of delivery of the device. ) For oxygen application, add Order code E0. 2) Available soon 3) Version 7MF4233-DY... only up to max. span 200 mbar a (80 inh 2 O a). 4) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.if the acceptance test certificate 3..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 5) If the acceptance test certificate 3..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 6) The diaphragm seal is to be specified with a separate order number and must be included wiht the transmitter order number, for example 7MF423.-..Y..-... and 7MF4900-...-.B 7) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 8) Not in conjunction with Electrical connection "Han7D plug". 9) Without cable gland, with blanking plug. 0) With enclosed cable gland Ex ia and blanking plug. ) Configurations with HAN and M2 connectors are only available in Ex ic. 2) Only in connection with IP66. 3) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 4) Only in connection with Ex apporval A, B or E. 5) Only in connection with Ex apporval A, B, E or F. 6) M2 delivered without cable socket /46 Siemens FI 0 207 US Edition

Siemens AG 207 Selection and Ordering data Article No. Pressure transmitters for absolute pressure from gauge pressure series SITRANS P DS III with PROFIBUS PA (PA) 7 M F 4 2 3 4 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 7 M F 4 2 3 5 - Click on the Article No. for the online configuration 7 7 7 7 7-7 7 7 7 in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid ) grease-free to cleanliness level 2 3 Nominal measuring range 250 mbar a (3.62 psia) D 300 mbar a (8.85 psia) F 5 bar a (72.5 psia) G 30 bar a (435 psia) H 60 bar a 2) (2 32 psia) L 400 bar a 2) (5 802 psia) M 700 bar a 2) (0 53 psia) N Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Version for diaphragm seals in conjunction with Y process connector "female thread ½-4 NPT" (recommended version) 3) 4) 5) 6) 7) Version for diaphragm seals in conjunction Y 0 with process connector "G½B connection shank"" 3) 4) 5) 6) 7) Process connection Connection shank G½B to EN 837-0 Female thread ½-4 NPT Stainless steel oval flange with process connection (Oval flange has no female thread) - Mounting thread 7 / 6-20 UNF to 2 IEC 658/DIN EN 658 - Mounting thread M0 to DIN 923 3 - Mounting thread M2 to DIN 923 4 Male thread M20 x.5 5 Male thread ½ -4 NPT 6 Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 3 Version Standard version, German plate inscription, setting for pressure unit: bar International version, English plate inscription, 2 setting for pressure unit: bar Chinese version, English plate inscription, 3 setting for pressure unit: Pascal All versions include DVD with compact operating instructions in various EU languages. Selection and Ordering data Article No. Pressure transmitters for absolute pressure from gauge pressure series SITRANS P DS III with PROFIBUS PA (PA) 7 M F 4 2 3 4 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 7 M F 4 2 3 5-7 7 7 7 7-7 7 7 7 Explosion protection None A With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" B - "Explosion-proof (Ex d)" 8) D - "Intrinsic safety and flameproof enclosure" P (Ex ia + Ex d)" 9) - "Ex na/ic (Zone 2)" 0) E - "Intrinsic safety, explosion-proof enclosure and R dust explosion protection (Ex ia + Ex d + Zone D/2D)" 9) ) (not for DS III FF) FM + CSA intrinsic safe (is) 2) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + S Zone D/2D 9))2) With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof N C (is + xp)" 8)2) Electrical connection/cable entry Screwed gland M20 x.5 B Screwed gland ½-4 NPT C M2 connectors (stainless steel) 3) 4) F Display Without display 0 Without visible display (display concealed, setting: bar) With visible display (setting: bar) 6 with customer-specific display 7 (setting as specified, Order code "Y2" or "Y22" required) A quick-start guide is included in the scope of delivery of the device. ) For oxygen application, add Order code E0. 2) Available soon 3) Version 7MF4233-DY... only up to max. span 200 mbar a (2.9 psia). 4) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) If the acceptance test certificate 3..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 6) The diaphragm seal is to be specified with a separate order number and must be included wiht the transmitter order number, for example 7MF423.-..Y..-... and 7MF4900-...-.B 7) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 8) Without cable gland, with blanking plug. 9) With enclosed cable gland Ex ia and blanking plug. 0) Configurations with HAN and M2 connectors are only available in Ex ic. ) Only in connection with IP66. 2) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 3) Only in connection with Ex approval A, B, E or F. 4) M2 delivered without cable socket. Siemens FI 0 207 US Edition /47

Siemens AG 207 Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Article No. and specify Order code. Pressure transmitter with mounting bracket (x fixing angle, 2 x nut, 2 x U- washer or x bracket, 2 x nut, 2 x U- washer) made of: Steel A0 Stainless steel 304 A02 Stainless steel 36L A03 Plug Han 7D (metal) A30 Han 8D (instead of Han 7D) A3 Angled A32 Han 8D (metal) A33 Cable sockets for M2 connectors A50 (metal (CuZn)) Rating plate inscription (instead of German) English B French B2 Spanish B3 Italian B4 Cyrillic (russian) B6 English rating plate B2 Pressure units in inh 2 0 and/or psi Quality Inspection Certificate (5-point C characteristic curve test) according to IEC 60770-2 ) Inspection certificate 2) C2 Acc. to EN 0204-3. Factory certificate C4 Acc. to EN 0204-2.2 Acceptance certificate (EN 0204-3.) C5 PMI test of parts in contact with medium Functional safety (SIL2) C20 Devices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration Functional safety (PROFIsafe) C2 3) Certificate and PROFIsafe protocol Functional safety (SIL2/3) C23 Devices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration PED for Russia with initial calibration C99 mark Setting of the upper saturation limit of D05 the output signal to 22.0 ma Manufacturer's declaration acc. to NACE (MR 003-202 and MR 075-2009) D07 Degree of protection IP66/IP68 D2 (only for M20 x.5 and ½-4 NPT) Supplied with oval flange D37 ( item), PTFE packing and screws in thread of oval flange Capri cable gland 4F CrNi and clamping D59 device (848699 + 80634) included Use in or on zone D/2D E0 (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-...-.B.. Ex ia) and IP65) Oxygen application E0 (In the case of oxygen measurement and inert liquid max. 00 bar (450 psi) at 60 C (40 F)) Export approval Korea E Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Article No. and specify Order code. CRN approval Canada E22 4) (Canadian Registration Number) Dual seal E24 Explosion-proof "Intrinsic safety" (Ex ia) E25 4) to INMETRO (Brazil) (only for transmitter 7MF4...-...-.B..) "Flameproof" explosion protection E26 4) according to INMETRO (Brazil) (only for transmitter 7MF4...-...-.D..) Explosion-proof "Intrinsic safety" E28 4) (Ex ia + Ex d) to INMETRO (Brazil) (only for transmitter 7MF4...-...-.P..) Ex Approval IEC Ex (Ex ia) E45 4) (only for transmitter 7MF4...-...-.B..) Ex Approval IEC Ex (Ex d) E46 4) (only for transmitter 7MF4...-...-.D..) Explosion-proof "Intrinsic safety" to E55 4) NEPSI (China) (only for transmitter 7MF4...-...-.B..) Explosion protection "Explosion-proof" E56 4) to NEPSI (China) (only for transmitter 7MF4...-...-.D..) Explosion-proof "Zone 2" to NEPSI E57 4) (China) (only for transmitter 7MF4...-...-.E..) Ex protection Ex ia", Ex d" and Zone E58 4) 2" to NEPSI (China) (only for transmitter 7MF4...-...-.R..) "Intrinsic safety" and "Explosion-proof" E70 4) explosion protection acc. to Kosha (Korea) (only for transmitter 7MF4...-...-.[B, D]..-Z + E) Ex-protection Ex ia according to EAC Ex E80 (Russia) Ex-protection Ex d according to EAC Ex E8 (Russia) Ex-protection Ex na/ic (Zone 2) according E82 to EAC Ex (Russia) Ex-protection Ex ia + Ex d + Zone D/2D E83 according to EAC Ex (Russia) Two coats of lacquer on casing and G0 cover (PU on epoxy) Transient protector 6 kv (lightning protect.) J0 Oval flange NAM (ASTAVA) J06 Marine approvals Det Norske Veritas Germanischer Lloyd (DNV-GL) S0 Lloyds Register (LR) S French marine classification society Bureau Veritas (BV) S2 American Bureau of Shipping (ABS) S4 Russian Maritime Register (RMR) S6 Korean Register of Shipping (KR) S7 ) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 2) If the acceptance test certificate 3. is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) Profisafe transmitters can only be operated with the S7 F Systems V6. configuration software in combination with S7-400H. 4) Cannot be ordered with remote seal. 5) Option does not include ATEX approval, but instead includes only the country-specific approval. /48 Siemens FI 0 207 US Edition

Siemens AG 207 Selection and Ordering data Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain text. Measuring range to be set Y0 ) Specify in plain text (max. 5 characters): Y0:... up to... mbar a, bar a, kpa abs, MPa abs, psia 2) Stainless steel tag plate and entry in Y5 device variable (measuring point description) Max. 6 characters, specify in plain text: Y5:... Measuring point text (entry in device Y6 variable) Max. 27 characters, specify in plain text: Y6:... Entry of HART address (TAG) Y7 Max. 8 characters, specify in plain text: Y7:... Setting of pressure indication in pressure Y2 units Specify in plain text (standard setting: bar): Y2: mbar, bar, kpa, MPa, psi,... Note: The following pressure units can be selected: bar, mbar, mm H 2 O *), inh 2 O *), fth 2 O *), mmhg, inhg, psi, Pa, kpa, MPa, g/cm 2, kg/cm 2, Torr, ATM or % *) ref. temperature 20 C Setting of pressure indication in Y22 + non-pressure units 3) Y0 Specify in plain text: Y22:... up to... l/min, m 3 /h, m, USgpm,... (specification of measuring range in pressure units "Y0" is essential, unit with max. 5 characters) Preset bus address Y25 possible between and 26 Specify in plain text: Y25:... Damping adjustment in seconds Y30 (0... 00 s) Factory mounting of valve manifolds, see accessories. Only Y0, Y5, Y6, Y7, Y2, Y22, Y25 and D05 can be factory preset = available ) Measuring accuracies for PROFIBUS PA transmitters with Option Y0 are calculated in the same way as for HART devices. 2) Only absolute pressure units selectable. Negative pressure values not permitted. 3) Preset values can only be changed over SIMATIC PDM. Siemens FI 0 207 US Edition /49

Siemens AG 207 Dimensional drawings 5 (0.6) 43 (5.6) 74 (2.9) 53 (2.) 54 (2.3) 27 (.) 24 (0.94) approx. 96 (3.78) 7 (0.67) 29 (.4) 84 (3.3) 5 approx. 40 (.6) Ø80 (3.5) 7 (6.7) 9 SW 36 8 72 (2.8) 2 50 (.97) 7 (4.6) 68 (2.68) 3 4 20 (4.72) 3 6 7 76 (6.93) 237 (9.33) Space for rotation of housing min. 90 (3.54) 4) 23 (4.84) Ø50... 60 (.97... 2.36) 05 (4.3) 2 3 4 Electronic side, digital display (longer overall length for cover with window) ) Terminal side ) Electrical connection: Screwed gland M20 x,5 or Screwed gland ½-4 NPT or Han 7D/Han 8D 2) 3) plug Harting adapter 5 Protective cover over keys 6 Blanking plug 7 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Process connection: Connection shank G½B or Oval flange 9 Mounting bracket (option) ) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing 2) Not with type of protection "Explosion-proof enclosure" 3) Not with type of protection "FM + CSA" [IS + XP]" 4) Minimum distance for rotating SITRANS P DS III pressure transmitters for absolute pressure, from the pressure series, dimensions in mm (inch) /50 Siemens FI 0 207 US Edition

Siemens AG 207 Technical specifications SITRANS P, DS III for absolute pressure (from the differential pressure series) Input Measured variable Absolute pressure Span (fully adjustable) or measuring range, max. operating HART pressure (in accordance with 204/68/EU Pressure Equipment Directive) and max. test pressure (pursuant to DIN 6086) Span Lower measuring limit Measuring cell with silicone oil filling Measuring cell with inert filling liquid - for process temperature -20 C < ϑ +60 C (-4 F < ϑ +40 F) - for process temperature 60 C < ϑ +00 C (max. 85 C for measuring cell 30 bar) (40 F < ϑ +22 F (max. 85 F for measuring cell 435 psi)) SITRANS P DS III for absolute pressure (from differential pressure series) 8.3... 250 mbar a 0.83... 25 kpa a 3... 00 inh 2 O a 43... 300 mbar a 4.3... 30 kpa a 7... 525 inh 2 O a 60... 5000 mbar a 6... 500 kpa a 2.32... 72.5 psia... 30 bar a 0.... 3 MPa a 4.5... 435 psia 5.3... 00 bar a 0.5... 0 MPa a 76.9... 450 psia 0 mbar a/0 kpa a/0 psia 30 mbar a/3 kpa a/0.44 psia PROFIBUS PA/ FOUNDATION Fieldbus Nominal measuring range 250 mbar a 25 kpa a 00 inh 2 O a 300 mbar a 30 kpa a 525 inh 2 O a 5000 mbar a 500 kpa a 72.5 psia 30 bar a 3 MPa a 435 psia 00 bar a 0 MPa a 450 psia 30 mbar a + 20 mbar a. (ϑ - 60 C)/ C 3 kpa a + 2 kpa a. (ϑ - 60 C)/ C 0.44 psi a + 0.29 psi a. (ϑ - 40 F)/ F Max. operating pressure MAWP (PS) 32 bar a 3.2 MPa a 464 psia 32 bar a 3.2 MPa a 464 psia 32 bar a 3.2 MPa a 464 psia 60 bar a 6 MPa a 2320 psia 60 bar a 6 MPa a 2320 psia Upper measuring limit 00 % of max. span (for oxygen measurement max. 00 bar/0 MPa/450 psi and 60 C (40 F) ambient temperature/process temperature) Start of scale value Between the measuring limits (fully adjustable) Output HART PROFIBUS PA/ FOUNDATION Fieldbus Output signal 4... 20 ma Digital PROFIBUS PA and FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 23 ma, factory preset to 20.5 ma or - optionally set to 22.0 ma Load Without HART R B (U H - 0.5 V)/0.023 A in Ω, - U H : Power supply in V With HART R B = 230... 500 Ω (SIMATIC PDM) or - R B = 230... 00 Ω (HART Communicator) Physical bus - IEC 658-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Electrical damping (step width 0. s) Set to 2 s (0... 00 s) Siemens FI 0 207 US Edition /5

Siemens AG 207 SITRANS P DS III for absolute pressure (from differential pressure series) SITRANS P, DS III for absolute pressure (from the differential pressure series) Measuring accuracy Acc. to IEC 60770- Reference conditions (All error data refer always refer to the set span) Increasing characteristic Start-of-scale value 0 bar/kpa/psi Stainless steel seal diaphragm Silicone oil filling Room temperature 25 C (77 F) Measuring span ratio r (spread, Turn-Down) r = max. measuring span/set measuring span or nom. pressure range Error in measurement at limit setting incl. hysteresis and reproducibility Linear characteristic -r 0 0. % - 0 < r 30 0.2 % Influence of ambient temperature (in percent per 28 C (50 F)) 250 mbar a/25 kpa a/3.6 psia (0.5 r + 0.) % 300 mbar a/30 kpa a/8.8 psia (0.08 r + 0.6) % 5 bar a/500 kpa a/72.5 psia 30 bar a/3000 kpa a/435 psia 00 bar a/0 MPa a/450 psia Long-term stability (0.25 r) % in 5 years (temperature change ± 30 C (± 54 F)) Effect of mounting position (in pressure per change in angle) 0.7 mbar/0.07 kpa/0.0005 psi per 0 inclination (zero point correction is possible with position error compensation) Effect of auxiliary power supply 0.005 % per V (in percent per change in voltage) Measuring value resolution for PROFIBUS PA and 3 0-5 of nominal measuring range FOUNDATION Fieldbus Rated conditions Degree of protection (to IEC 60529) IP66 (optional IP66/IP68), NEMA 4X Temperature of medium Measuring cell with silicone oil filling -40... +00 C (-40... +22 F) Measuring cell with inert filling liquid -20... +00 C (-4... +22 F) In conjunction with dust explosion protection -20... +60 C (-4... +40 F) Ambient conditions Ambient temperature - Transmitter -40... +85 C (-40... +85 F) - Display readable -30... +85 C (-22... +85 F) Storage temperature -50... +85 C (-58... +85 F) Climatic class - Condensation Relative humidity 0... 00 % Condensation permissible, suitable for use in the tropics Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 6326 and NAMUR NE 2 /52 Siemens FI 0 207 US Edition

Siemens AG 207 SITRANS P DS III for absolute pressure (from differential pressure series) SITRANS P, DS III for absolute pressure (from the differential pressure series) Design Weight (without options) 4.5 kg ( 9.9 (lb) Enclosure material Low-copper die-cast aluminum, GD-AlSi2 or stainless steel precision casting, mat. no..4408 Wetted parts materials Seal diaphragm Stainless steel, mat. no..4404/36l or Hastelloy C276, mat. no. 2.489, Monel, mat. no. 2.4360, tantalum or gold Process flanges and sealing screw Stainless steel, mat. no..4408, Hastelloy C4, mat. no. 2.4602 or Monel, mat. no. 2.4360 O-Ring FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxigen measurement pressure 00 bar (450 psi) at 60 C (40 F)) Process connection ¼-8 NPT and flange connection with mounting thread M0 to DIN 923 or 7 / 6-20 UNF to IEC 658/DIN EN 658 Material of mounting bracket Steel Sheet-steel, Mat. No..0330, chrome-plated Stainless steel Sheet stainless steel, mat. no..430 (SS 304) Power supply U H HART PROFIBUS PA/FOUNDATION Fieldbus Terminal voltage on transmitter 0.5... 45 V DC - 0.5... 30 V DC in intrinsically-safe mode Power supply Supplied through bus Separate 24 V power supply necessary - No Bus voltage Not Ex - 9... 32 V With intrinsically-safe operation - 9... 24 V Current consumption Basic current (max.) - 2.5 ma Start-up current basic current - Yes Max. current in event of fault - 5.5 ma Fault disconnection electronics (FDE) available - Yes Siemens FI 0 207 US Edition /53

Siemens AG 207 SITRANS P DS III for absolute pressure (from differential pressure series) SITRANS P, DS III for absolute pressure (from the differential pressure series) Certificates and approvals HART PROFIBUS PA/ FOUNDATION Fieldbus Classification according to PED 204/68/EU For gases of fluid group and liquids of fluid group ; complies with requirements of article 4, paragraph 3 (sound engineering practice) Explosion protection Intrinsic safety "i" PTB 3 ATEX 2007 X - Marking Ex II /2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Permissible ambient temperature -40... +85 C (-40... +85 F) temperature class T4; -40... +70 C (-40... +58 F) temperature class T5; -40... +60 C (-40... +40 F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw; R i =300Ω FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.32 W Linear barrier: U o = 24 V, I o = 250 ma, P o =.2 W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 μh, C i =. nf Explosion-proof "d" PTB 99 ATEX 60 - Marking Ex II /2 G Ex d IIC T4/T6 Gb - Permissible ambient temperature -40... +85 C (-40... +85 F) temperature class T4; -40... +60 C (-40... +40 F) temperature class T6 - Connection To circuits with values: H =0.5...45 V DC To circuits with values: U H = 9... 32 V DC Dust explosion protection for zone 20 PTB 0 ATEX 2055 - Marking Ex II D Ex ta IIIC T20 C Da Ex II /2 D Ex ta/tb IIIC T20 C Da/Db - Permissible ambient temperature -40... +85 C (-40... +85 F) - Max. surface temperature 20 C (248 F) - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw, R i = 300 Ω FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.32 W Linear barrier: U o = 24 V, I o = 250 ma, P o =.2 W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 μh, C i =. nf Dust explosion protection for zone 2/22 PTB 0 ATEX 2055 - Marking Ex II 2 D Ex tb IIIC T20 C Db - Connection To circuits with values: U H = 0.5... 45 V DC; P max =.2 W Type of protection "n" (zone 2) PTB 3 ATEX 2007 X - Marking Ex II 2/3 G Ex na II T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Connection (Ex na) U m = 45 V U m = 32 V - Connection (Ex ic) To circuits with values: U i = 45 V To circuits with values: U H = 9... 32 V DC; P max = W FISCO supply unit ic: U o = 7.5 V, I o = 570 ma Linear barrier: U o = 32 V, I o = 32 ma, P o = W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 μh, C i =. nf Explosion protection acc. to FM Certificate of Compliance 3008490 - Identification (XP/DIP) or (IS); (NI) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; CL I, ZN 0/ AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Explosion protection to CSA Certificate of Compliance 5365 - Identification (XP/DIP) or (IS) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III /54 Siemens FI 0 207 US Edition

Siemens AG 207 HART communication HART 230... 00 Ω Protocol HART Version 5.x Software for computer PROFIBUS PA communication Simultaneous communication with master class 2 (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks 2 Analog input - Adaptation to customer-specific process variables SIMATIC PDM 4 Configuration tool or local operation (standard setting address 26) 5 (one measured value) or 0 (two measured values) 0,, or 2 (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, class B Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0... 00 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block Transducer blocks 2 Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Specification of a container Max. 30 nodes characteristic with - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function SITRANS P DS III for absolute pressure (from differential pressure series) FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, function block PID Analog input - Adaptation to customer-specific process variables characteristic Yes, linearly rising or falling - Electrical damping, adjustable 0 to 00 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FOUNDATION Fieldbus function block Physical block resource block Transducer blocks transducer block Pressure with calibration, transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function Siemens FI 0 207 US Edition /55