HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Similar documents
Change-Over Pressure Filter DFDK

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

PVQ 13 A2 R SE 1 S 20 C-11 D

Safety and Shut-off Block SAF/DSV

B84G - Excelon Plus Modular System General purpose filter/regulator

Pressure reducing valve, direct operated

Directional Controls

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

D e s c r i p t i o n

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Principles of Filtration. Filter Elements. High Pressure Filters. Section 4. Tank-Mounted, Return Line and Medium Pressure Filters

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us:

Safety and Shut-off Block SAF/DSV

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Pressure reducing valve, pilot operated, Model 3DR

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

B84G - Excelon Plus Modular System General purpose filter/regulator

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

TECHNICAL DATA. Q = C v P S

Tank-Mounted Suction Filter

Spin-On Filters SSF 24,25

Directional Controls

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Bladder Accumulators High pressure

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

shutoff valves 900 Series psig Manual Shutoff Valves

Diaphragm Accumulators

SATURNSERIES INTERCHANGE > ISO (for the couplings)

Safety and Shut-off Block SAF/DSV

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

3-Way Safety Block DSV

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Safety and Shut-off Block SAF/DSV

Pressure-controlled shut-off valve type CNE

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Series BLK Oil - air cooler

CASH VALVE TYPE KP BACK PRESSURE VALVES

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Cover headline. Cover subheadline. Check Valves

Compressed Air Cleaning Filter Series

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Safety and Shut-off Block SAF/DSV

B74G - EXCELON Modular System General purpose filter/regulator

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

180 Series Rotary Shear Directional Control Valve

Electrically Operated Pressure-Relief Cartridge, Size 10

Two-stage valve type NE

Diaphragm Accumulators

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

R84G - Excelon Plus Modular System Pressure regulators

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Avenger Model 33M Installation & Operation Instructions

Flow rates to 200 l/min

Diaphragm Accumulators

PRESSURE COMPENSATORS TECNORD

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Hydraulic Piston Accumulators

Type EZH Relief or Backpressure Regulator

SDM to 8 sections monoblock valve D1WWDA02A

Check valve hydraulically pilot operated

WaterSource Heat Pump Hose Kit Performance Specification-Summary

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

hyprofiltration.com/fsw

directional control valve series cv691

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Pressure reducing valve, direct operated

DISC VALVE HYDRAULIC MOTORS

627 Series Pressure Reducing Regulators

Tank Blanketing Pressure Regulators RHPS Series

Inverse Prop. Pressure-Relief Cart., Size 2 4

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)

Directional Valves. Hydraulic Operated Directional Valves

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

INDUSTRIAL EXCESS ESS FLOW VALVES

Transcription:

DFDK Series Inline Duplex Filters 4568 psi up to 9 gpm Hydraulic Symbol DFDK QL L Ball Valve A DFDK QT T Ball Valve (sizes 33 or larger) A B B Features The DFDK Filters have a filter head of ductile iron and a screw-in bowl of cold-formed steel. The filter housings are designed to withstand pressure surges as well as high static pressure loads. The screw-in bowl or lid, allows the filter element to be easily removed for replacement or cleaning. A visual (pop-up), electrical, electrical/visual (lamp), or other electronic differential types of clogging indicators are available to suit each application. DFDK filters are available only with high collapse pressure elements since no bypass is provided. DFDK sizes 33 and above can be ordered with a T Ball Valve which can operate in mid position with both elements fully open and online in parallel. Applications Automotive Industrial Power Pulp & Paper Generation Railways Steel / Heavy Industry Technical Specifications Mounting Method 4 mounting holes Port Connection 6/11 16/24/28 33/66/132 SAE-12 SAE-24 2 SAE-DN 51 Code 62 Flange Flow Direction 6-28 33-132 Inlet Outlet Construction Materials Head Bowl Housing (132) Lid/Cap (132) Flow Capacity 6/11 16/24/28 33/66/132 Housing Pressure Rating Max. Allowable Working Pressure Fatigue Pressure Burst Pressure Top Side Ductile iron Steel Steel Ductile iron 13 gpm (5 lpm) 35 gpm (132 lpm) 9 gpm (34 lpm) Top Back 4568 psi (3 bar) Contact HYDAC Office > 18,27 psi (126 bar) Element Collapse Pressure Rating BH4HC, V 345 psid (21 bar) Fluid Temperature Range 14 F to 212 F (-1 C to 1 C) Consult HYDAC for applications operating below 14ºF (-1ºC) Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected. Indicator Trip Pressure P = 116 psid (8 bar) -1% (standard) Non-bypass Only F6 PN#281318 / 3.16 / FIL5-1696

Model Code Filter Type DFDK = Duplex Pressure Filter with Ball Valve Selector Element Media BH/HC = Betamicron (High Collapse) V = Metal Fiber Size 6, 11, 16, 24, 28, 33, 66, 132 (larger sizes available - contact HYDAC) Pressure Range K = 232 psi (16 bar) (sizes 132 with type code 3 only - larger sizes upon request) Q = 4568 psi (3 bar) (sizes 3-132 with type code 1 or 2 only) Valve L = ball change-over valve in L configuration (standard) T = ball change-over valve in T configuration (full simultaneous flow through both sides - sizes 33 and larger) Connection B = 1/2 SAE 8 (size 3 only) C = 3/4 SAE 12 (sizes 6/11 only) F = 1 1/2 SAE 24 (sizes 16-28 only) Filtration Rating (micron) 3, 5, 1, 2 = BH/HC 3, 5, 1, 2 = V Type of P Clogging Indicator A, B, BM, C, D (others available upon request) L = 2 SAE DN 51 Code 62 (sizes 33-132 only) M = 2 1/2 SAE DN 64 Code 62 (sizes 132 only) - 3. only Type Code 1 = One Piece Bowl (sizes 6-66 only) 2 = Two Piece Bowl (size 66 to 132 only) 3 = Upside down mounting - Element top access (size 132 only - larger sizes upon request) Modification Number (latest version always supplied) Port Configuration omit = 2 SAE DN 5 Flange Ports (sizes 33-132 only) 12 = SAE Straight thread O-ring Boss Ports (sizes 6-28 only) HIGH PRESSURE FILTERS DFDK BH/HC 6 Q L C 3 A 1. 2 -. Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene Propylene (EPR) Supplementary Details L24, L48, L11, L22 = Lamp for D-type clogging indicator (LXX, XX = voltage) W = VD indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) SO263 = Modification of ON & W/HC elements for Skydrol or HYJET phosphate ester fluids T1 = Thermal lockout on indicator at 1 F (C, D, J, and J4 indicators only) cruus = Electrical Indicator with underwriter s recognition SFREE = Element specially designed to minimize electrostatic charge generation Replacement Element Model Code 6 D 3 BH4HC / V Size 6, 11, 16, 24, 28, 33, 66, 132 Filtration Rating (micron) 3, 5, 1, 2 = BH4HC 3, 5, 1, 2 = V Element Media BH4HC, V Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Supplementary Details SO263 = (same as above) SFREE = (same as above) W = Modification of V elements for use with oil water emulsions (HFA) and water polymer solutions (HFC) Clogging Indicator Model Code VD 8 B. X /. Indicator Prefix VD = G 1/2 6 psi Trip Pressure 8 = 116 psid (8 bar) Type of Indicator A = No indicator, plugged port B = Pop-up indicator (auto reset) BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT Modification Number Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene propylene rubber (EPR) Light Voltage (D type indicators only) L24 = 24V L11 = 11V Thermal Lockout (VM, VD types C, D, J, and J4 only) T1 = Lockout below 1 F Underwriters Recognition (VM, VD types C, D, J, and J4 only) cruus = Electrical Indicator with underwriter s recognition W = VD indicator modified with a brass piston for use with high water based emulsions/solutions (HFA) & (HFC) (For additional details and options, see Section G - Clogging Indicators.) Model Codes Containing RED are non-stock items Minimum quantities may apply Contact HYDAC for information and availability PN#281318 / 3.16 / FIL5-1696 F61

Dimensions DFDK 6 / 11 / 16 / 24 / 28 P Clogging Indicator Port G 1/2" b1 Clean Side b11 b4 b8 Dirty Side b9 INLET d1 22.3 b14 b13.24 6 b2 SQ1 b7 b1 b12 OUTLET d2 h6 h2 h5 h7 MAX h4 h1 h3 d4 x t1 HEX 1 h9 b6 b5 d3 HEX 2 drain G 1/2" Drain h8 Clearance Required for Element Removal Size 6 11 16 24 28 Weight (lbs.) 33.1 37.5 72.8 79.4 99.3 Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. F62 PN#281318 / 3.16 / FIL5-1696

DFDK 6 11 16 24 28 b1 [5.43] 138 [5.43] 138 [7.48] 19 [7.48] 19 [7.48] 19 b2 [6.69] 17 [6.69] 17 [8.27] 21 [8.27] 21 [8.27] 21 b4 [3.62] 92 [3.62] 92 [5.4] 128 [5.4] 128 [5.4] 128 b5 [1.77] 45 [1.77] 45 [2.7] 52.5 [2.7] 52.5 [2.7] 52.5 b6 [4.78] 121.5 [4.78] 121.5 [6.2] 7.5 [6.2] 7.5 [6.2] 7.5 b7 [2.13] 54 [2.13] 54 [2.97] 75.5 [2.97] 75.5 [2.97] 75.5 b8 [1.2] 26 [1.2] 26 [1.4] 35.5 [1.4] 35.5 [1.4] 35.5 b9 [3.43] 87 [3.43] 87 [4.13] [4.13] [4.13] b1 [1.91] 48.5 [1.91] 48.5 [2.7] 52.5 [2.7] 52.5 [2.7] 52.5 b11 [2.13] 54 [2.13] 54 [2.97] 75.5 [2.97] 75.5 [2.97] 75.5 b12 [.63] 16 [.63] 16 [.39] 1 [.39] 1 [.39] 1 b13 ( ) [5.91] [5.91] [7.6] 193 [7.6] 193 [7.6] 193 b14 ( ) [7.13] 181 [7.13] 181 [8.7] 221 [8.7] 221 [8.7] 221 d1* d2* 1-1/16-12UN-2B SAE-12 1-7/8-12UN-2B SAE-24 d3 [2.69] 68.2 [2.69] 68.2 [3.75] 95.2 [3.75] 95.2 [3.75] 95.2 d4 1/4-28UNF-2B 3/8-24UNF-2B h1 [3.7] 78 [3.7] 78 [3.78] 96 [3.78] 96 [3.78] 96 h2 [4.61] 117 [4.61] 117 [6.38] 162 [6.38] 162 [6.38] 162 h3 [.77] 19.5 [.77] 19.5 [1.3] 33 [1.3] 33 [1.3] 33 h4 [2.54] 64.5 [2.54] 64.5 [4.17] 16 [4.17] 16 [4.17] 16 h5 [2.99] 76 [2.99] 76 [3.94] 1 [3.94] 1 [3.94] 1 h6 [8.7] 25 [1.89] 276.5 [11.2] 284.5 [13.6] 345.5 [2.69] 525.5 h7 ( ) [8.7] 25 [8.7] 25 [9.65] 245 [9.65] 245 [9.65] 245 h8 [2.95] 75 [2.95] 75 [3.35] 85 [3.35] 85 [3.35] 85 h9 [.2] 5 [.2] 5 [.2] 5 [.2] 5 [.2] 5 t1 [.28] 7 [.28] 7 [.43] 11 [.43] 11 [.43] 11 HEX1 [1.6] 27 [1.6] 27 [1.26] 32 [1.26] 32 [1.26] 32 HEX2 [.39] 1 [.39] 1 [.39] 1 [.39] 1 [.39] 1 SQ1 [.47] 12 [.47] 12 [.55] 14 [.55] 14 [.55] 14 Dimensions shown are [inches] millimeters for general information and overall envelope size only. PN#281318 / 3.16 / FIL5-1696 F63

Dimensions DFDK 33 / 66 1.2.62.7 Dirty Side 6.89 175 12.8 325 Clean Side P Clogging indicator port G1/2" Vent Plug G1/8" 1.63 27 Lifting holes [.67] 1/2-2UNF-2B x 17 DP 5.91.24 6 7.87 2.31 8 Mounting ring size 66 only Indexing plunger for locking the lever (optional) 8.98 228 Pressure Equalization Valve INLET SAE 2"(DN5) 6 PSI.62.7 2.38 6.5 3.27 83 SIZE 33 [14.51] 368.5 SIZE 66 [21.18] 538 5.39 137 3.86 98 OUTLET SAE 2" (DN5) 6 PSI Drain Port G 1/2" 5.13 13.2 5.98 2 [3.74] 95 Clearance required for element removal 4.69 11.61.59 5.8 119 295.79 129 2 INLET / OUTLET Flange 3.81 96.8 8.23 29.67 1/2-2UNF-2B X 17 DP 4 PLS 3.23 82 9.65 245 6.69 17 1.42 36 HEX 1.75 44.5 3/4-1UNC-2B x [.98] Min. 25 Full Thread 4 PL's Size 33 66 Weight (lbs.) 213.9 249 Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. F64 PN#281318 / 3.16 / FIL5-1696

Dimensions DFDK 66 / 132 2.2 Dirty Side HIGH PRESSURE FILTERS Clean Side.62.7 6.89 175 12.8 325 P Clogging Indicator Port G 1/2" Vent plug G1/8" 1.63 27 Lifting Holes [.67] 1/2-2UNF-2B x 17 DP 5.91.24 6 8.98 228 Indexing plunger for locking lever (Optional) Pressure equalization valve 2.38 INLET 6.5 SAE 2" (DN5) 6 PSI.62.7 5.39 137 7.87 2 3.86 98 SIZE 66 [2.91] 531 SIZE 132 [33.58] 853 3.27 83 OUTLET SAE 2" (DN5) 6 PSI 4.41 112 Drain port G 1/2" SIZE 66 [13.78] 35 SIZE 132 [26.38] 67 5.2 132 5.98 2 INLET / OUTLET Flange 3.81 96.8 4.69 119 5.8 129 11.61 295.59.79 2 1.75 44.5 3/4-1UNC-2B x [.98] Min. 25 Full Thread 8.23 29.67 1/2-2UNF-2B X 17 DP 4 PLS 3.23 82 1.42 36 HEX Size 66 132 Weight (lbs.) 262.5 335.1 Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. 9.65 245 6.69 17 PN#281318 / 3.16 / FIL5-1696 F65

Sizing Information Total pressure loss through the filter is as follows: Assembly P = Housing P + Element P Housing Curve: Pressure loss through housing is as follows: Actual Specific Gravity Housing P = Housing Curve P x.86 Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see Sizing HYDAC Filter Assemblies in Section B - Overview) DFDK 6 / 11 Housing DFDK 16 / 24 / 28 Housing Q (l/min) 35 2 4 6 8 1 3 25 2. 1.5 Q (l/min) 5 3 6 9 12 18 4 3. 2.5 ΔP in psi 2 1. ΔP in bar ΔP in psi 3 2 2. 1.5 ΔP in bar 1 5.5 1 1..5 1 2 3 Q (gpm) 1 2 3 4 5 Q (gpm) DFDK 33 / 66 / 132 QLL Housing L Ball Valve Q (l/min) 1 2 3 4 5 6 3 2. 35 DFDK 33 / 66 / 132 QTL Housing T Ball Valve Q (l/min) 1 2 3 4 5 6 7 8 9 25 3 2. ΔP in psi 2 1 5 1.5 1..5 ΔP in bar ΔP in psi 25 2 1 5 1.5 1..5 ΔP in bar 2 4 6 8 1 12 14 16 Q (gpm) 5 1 2 25 Q (gpm) F66 PN#281318 / 3.16 / FIL5-1696

Element K Factors Actual Viscosity (SUS) x Actual Specific Gravity P Elements = Elements (K) Flow Factor x Flow Rate (gpm) x (From Tables Below) 141 SUS.86 HIGH PRESSURE FILTERS Betamicron...D BH4HC Elements (High Collapse) Size 3 µm 5 µm 1 µm 2 µm 6 D XXX BH4HC 3.216 1.789.993.67 11 D XXX BH4HC 1.394.818.489.37 16 D XXX BH4HC.922.571.324.241 24 D XXX BH4HC.582.373.214.9 28 D XXX BH4HC.313.187.99.88 33 D XXX BH4HC.423.247.4.11 66 D XXX BH4HC.181.14.55.49 132 D XXX BH4HC.88.55.33.22 Metal Fiber...D V Elements (High Collapse) Size 3 µm 5 µm 1 µm 2 µm 6 D XXX V.877.511.296.183 11 D XXX V.452.34.182.118 16 D XXX V.251.177.123.79 24 D XXX V.169.137.93.62 28 D XXX V.126.93.64.41 33 D XXX V.121.97.65.43 66 D XXX V.63.5.34.21 132 D XXX V.32.26.18.12 All Element K Factors in psi / gpm. Notes PN#281318 / 3.16 / FIL5-1696 F67