1 Change-Over Pressure Filter up to 8 l/min, up to 35 bar x 66.x 99.x 3.x 3 3.x 64 3.x x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed in accordance with international regulations. They consist of a filter head with screw-in filter bowls. Standard equipment: ball change-over valve two-piece filter bowl for 99, 3, 64, 369 (as an option for 66) connection for a clogging indicator drain screw with pressure relief pressure equalization line (for size 33 and above). FILTER ELEMENTS HYDAC filter elements are validated and their quality is constantly monitored according to the following standards: ISO 94, ISO 94, ISO 943, ISO 374, ISO 3968, ISO 7, ISO 6889 Number of filter elements Elements per side 3 x3 D 6 x6 D x D 4 x4 D 6 x6 D 4 x4 D 8 x8 D 33 x33 D 5 x5 D 66 x66 D 99 x99 D 3 x3 D 3.3.X 64.3.X X x3 D x3 D 3x3 D Filter elements are available with the following pressure stability values: Optimicron (ON): bar Betamicron (BH4HC): bar Wire mesh (W/HC, W): bar Stainless steel fibre (V): bar.3 FILTER SPECIFICATIONS Nominal pressure 6 bar ( with type code 3.X) 35 bar ( with type code.x and.x) Fatigue strength At nominal pressure 6 cycles from to nominal pressure Temperature range - C to + C (-3 C to - C: p max = 57.5 bar) Material of filter head EN-GJS-4-5 Material of filter bowl Steel Type of clogging indicator VD (differential pressure measurement up to 4 bar operating pressure) Pressure setting of the clogging indicator 8 bar (others on request).4 SEALS NBR (=Perbunan).5 INSTALLATION As inline filter.6 SPECIAL MODELS AND ACCESSORIES Pressure equalization line for 6-8 Detent pin to lock the lever for x/.x Ball change-over in T configuration (simultaneous flow on both sides including detent).7 SPARE PARTS See Original Spare Parts List.8 CERTIFICATES AND APPROVALS On request.9 COMPATIBILITY WITH HYDRAULIC FLUIDS ISO 943 Hydraulic oils H to HLPD DIN 554 Lubrication oils DIN 557, API, ACEA, DIN 555, ISO 6743 Compressor oils DIN 556 Biodegradable operating fluids VDMA 4568 HETG, HEES, HEPG Fire-resistant operating fluids HFA, HFB, HFC and HFD Operating fluids with high water content (>5% water content) and CLP oils on request. IMPORTANT INFORMATION Filter housings must be earthed. When using electrical clogging indicators, the electrical power supply to the system must be switched off before removing the clogging indicator connector. Symbol for hydraulic systems ball change-over in L configuration Symbol for hydraulic systems ball change-over in T configuration E /.6
2 . MODEL CODE (also order example). COMPLETE FILTER Filter type Filter material ON Optimicron V Metal fibre BH/HC Betamicron (BH4HC) W/HC, W Wire mesh Size of filter or element : 3, 6,, 4, 6, 4, 8, 33, 5, 66, 99, 3, 64, 396 Operating pressure Q 35 bar K 6 bar (only for 3, 64, x) Type of change-over L T ball change-over in L configuration (standard) ball change-over in T configuration (i.e. simultaneous flow through both sides; only in combination with BH/HC and V filter elements) ON 6 Q L F D. X /-L4 Type and size of connection Type Port Filter size /64/ x B G ½ C G ¾ F G ½ L SAE DN 5* M SAE DN 65** * Flange SAE, 6 PSI ** Flange SAE, 3 PSI Filtration rating in µm ON:, 3, 5,, 5, BH/HC, V: 3, 5,, W/HC, W: 5, 5,, Type of clogging indicator Y plastic blanking plug in indicator port A steel blanking plug in indicator port B visual for other clogging indicators, C electrical see brochure no /.. D visual and electrical Type code model with one-piece filter bowls model with two-piece filter bowls (only for 66 to 3) 3 top-removable model (only for 3 to 396) Modification number X the latest version is always supplied Supplementary details L... light with appropriate voltage (4V, 48V, V, V) only for clogging LED light-emitting diodes up to 4 Volt indicators Type D SO668 detent pin to lock lever (only for x/.x) V FPM seals W suitable for HFA and HFC emulsions. REPLACEMENT ELEMENT Size 3, 6,, 4, 6, 4, 8, 33, 5, 66, 99, 3 Type D Filtration rating in µm ON:, 3, 5,, 5, BH4HC, V: 3, 5,, W/HC, W: 5, 5,, Filter material ON, BH4HC, V, W/HC, W (with ball change-over in T configuration only possible for BH4HC and V filter elements!) Supplementary details V, W (for descriptions, see Point.) 6 D ON /-V E /.6.3 REPLACEMENT CLOGGING INDICATOR VD 8 D. X /-L4 Type VD differential pressure indicator up to 4 bar operating pressure Pressure setting 8 standard 8 bar, others on request Type of clogging indicator D (see Point.) Modification number X the latest version is always supplied Supplementary details L..., LED, V, W (for descriptions, see Point.)
3 3. FILTER CALCULATION / SIZING The total pressure drop of a filter at a certain flow rate Q is the sum of the housing p and the element p and is calculated as follows: p total = p housing + p element p housing = (see Point 3.) p element = Q SK* viscosity 3 (*see Point 3.) For ease of calculation, our Filter Sizing Program is available on request free of charge. NEW: Sizing online at 3. p-q HOUSING CURVES BASED ON ISO 3968 The housing curves apply to mineral oil with a density of.86 kg/dm³ and a kinematic viscosity of 3 mm²/s. In this case, the differential pressure changes proportionally to the density x with ball changeover in L configuration 6,, 4....x with ball change-over in L configuration 6, 4, 8....x with ball change-over in L configuration 3....x with ball changeover in T configuration ,, 4....x with ball change-over in T configuration , 4, 8....x with ball change-over in T configuration , 5, x 66, 99, 3....x with ball change-over in T configuration x x x , 5, x 66, 99, 3....x with ball change-over in L configuration E /.6 3
4 3. GRADIENT COEFFICIENTS (SK) FOR FILTER ELEMENTS The gradient coefficients in mbar/(l/min) apply to mineral oils with a kinematic viscosity of 3 mm²/s. The pressure drop changes proportionally to the change in viscosity. ON µm 3 µm 5 µm µm 5 µm µm V W/HC, W BH4HC 3 µm 5 µm µm µm 3 µm 5 µm µm µm E /.6 4
5 4. DIMENSIONS 3-8 blanking plug SW 7 or clogging indicator if required outlet drain E = vent inlet deep * SAE connection 6 psi b b b b b b b b b b b b3 ( ) b4 ( ) d* G ½ G ¾ G ¾ G ¾ G ½ G ½ G ½ d* G ½ G ¾ G ¾ G ¾ G ½ G ½ G ½ d d4 M6 M6 M6 M6 M M M h h h h h h h7 ( ) h h t SW SW 6 SW Weight incl. element [kg] Volume of pressure chamber [l] x.3 x. x.33 x.4 x.6 x.8 x.6 E /.6 5
6 x x detent pin to lock the lever, optional drain G/, SW 4x M x 5.5 deep M x 7 deep pressure equalization spindle E /.6 Size Size 33 Size 5 Size Size Size 66 outlet drain M (additional holes for installation) vent G/8, SW 5 port for clogging indicator inlet x 66.x 99 3 h Weight incl. element [kg] Volume of pressure chamber [l] x.5 x. x3. x3. x4.5 x6. 6
7 top-removable models 3, 64, x blanking plug SW 7 or clogging indicator as an option deep vent Series 3 pressure equalization Series 64 inlet test point drain outlet Series x x x b b b b b b h h Weight incl. element [kg] approx. 5 approx. 445 approx. 64 Volume of pressure chamber [l] x 7. x 4. x. E /.6 7
8 NOTES E /.6 NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. HYDAC Filtertechnik GmbH Industriegebiet D-668 Sulzbach/Saar Tel.: / 59- Fax: / 59-3 Internet: filter@hydac.com 8
HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm
DFDK Series Inline Duplex Filters 4568 psi up to 9 gpm Hydraulic Symbol DFDK QL L Ball Valve A DFDK QT T Ball Valve (sizes 33 or larger) A B B Features The DFDK Filters have a filter head of ductile iron
More information3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
More informationLMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.
LMP 900-90 Filter element in according to D 550 Style S Style D.I. D.I. Maximum pressure 30 bar F l o w r a t e s t o 0 0 0 l / m i n 6 Technical data Filter housing (Materials) Head: nodised luminium
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm
Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features
More informationD 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min
Pressure Filters D D 6 In-line mounting Operating pressure up to 1 bar Nominal flow rate up to 9 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance
More informationHydraulic Accumulators with Back-Up Nitrogen Bottles
Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. Description 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1.1.1 Key to the circuit diagram Circuit diagram The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies
More informationE 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min
Return Filters E E E 6 E 6 E 7 Tank mounting Nominal flow rate up to 8 l/min Description Application In the return line circuits of hydraulic systems. Performance features Protectionagainst wear: By means
More informationE 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators. It complies with the relevant safety standards
More informationE 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow
More informationSuction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters
Suction fi lters SF 5 series Flow rate up to 8 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for
More informationE 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d
R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in
More informationBladder Accumulators High pressure
Bladder Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas (nitrogen) is utilised in
More informationDiaphragm Accumulators
Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators for storing
More informationSafety and Shut-off Block SAF/DSV
1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with
More informationPressure reducing valve, pilot operated
Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content
More informationE 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm
Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:
More informationPressure reducing valve, pilot operated, Model 3DR
RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features
More informationFlow rates to 200 l/min
LMP MULTIPORT - - Maximum pressure bar low rates to l/min Technical data ilter housing (Materials) Head: luminium Housing: ataphoresis-painted Steel ypass valve: rass - luminium Pressure Working pressure:
More informationE 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm
Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow
More informationMonoblock Directional Control Valve RMB 202
Monoblock Directional Control Valve RMB 202 Key valve features RMB 202 is a 2-section mono block valve, especially designed for front-end loaders. The valve is prepared for quick connecting couplings,
More informationLMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n
LMP Maximum pressure 8 bar F l o w r a t e s t o 6 l / m i n Technical data Filter housing (Materials) Head: luminium Housing: ataphoresis Painting ypass valve: rass - luminium Pressure LMP length: - -
More informationSpin-On Filters SSF 24,25
Spin-On Filters SSF,5 Technical Specification Construction Die cast aluminium head Seals NBR (Buna-N ) Port connections Flow rate Working pressure Operating temperature By-pass valve Clogging indicators
More informationMPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min
MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 1 bar Flow rates to l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for both
More informationSPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER
PM Pressure Filters MEDIUM PREURE INLINE FILTER Pressure Filters PM PM MPa (0 bar) Port sizes: 1/ 1 Flow rates: 10 l/min TECHNICAL DATA Max. working pressure: MPa (0 bar) Max. test pressure: MPa (0 bar)
More informationPressure reducing valve, direct operated
Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min
More informationBladder Accumulators Standard model
Bladder Accumulators Standard model 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic
More informationSeries BLK Oil - air cooler
Series BLK Oil - air cooler maintenance friendly design broad performance range compact dimensions rugged cooling matrix low noise emissions comprehensive accessories DE 35 0001 04/2004 Bühler Meß- und
More informationD e s c r i p t i o n
MPS Series D e s c r i p t i o n The MPS spin-on filter series is a complete product range suitable, for both suction and return applications. Utilising spin-on canisters, the MPS series are quick and
More informationPressure relief valves
Pressure relief valves Type DV700 Features Direct operated valve High degree of pressure stability Safe operation Precise pressure adjustment Maximum pressure setting with lock nut Applications as cartridge
More informationP2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES
52 000/110 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by
More informationE 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min
Return Filters E E Tank top mounting Connection up to G¼ ominal flow rate up to l/min Description pplication In the return line circuits of hydraulic systems. Performance features Protection against wear:
More informationAuxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998
Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal
More informationBladder Accumulators Standard
Bladder Accumulators 1. DESCRIPTION 1.1. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators for
More informationPressure relief valve, direct operated
Pressure relief valve, direct operated RE 570/0.05 Replaces: 06.03 /8 Type DBD..K Size Component series X Maximum operating pressure 500 bar Maximum flow 0 l/min K9- Table of contents Contents Page Features
More informationPilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1
Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Size
More informationCheck valve hydraulically pilot operated
Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents
More informationSATURNSERIES INTERCHANGE > ISO (for the couplings)
Saturn Block INTERCHANGE > ISO 16028 (for the couplings) PATENTED ISO 16028 TECHNICAL FEATURES AND OPTIONS Interchange ISO 16028 (for the couplings) Sealing description Nitrile NBR Connection system Push
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationPressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)
Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series) Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, sandwich
More informationDiaphragm Accumulators
Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators
More informationDiaphragm Accumulators
1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationPressure reducing valve, direct operated, type DR 5 DP Huade América 1
Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, type DR 5 DP Size 5 up to 31.5MPa up to
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationFIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:
LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are
More informationPressure reducing valve, direct operated
Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationElectrically Operated Pressure-Relief Cartridge, Size 10
Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description
More informationLiquid level regulating valves Types PMFL / PMFH and SV
Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve
More informationSOLENOID VALVES AND PNEUMATIC VALVES
9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)
More informationPressure relief valve, direct operated
ressure relief valve, direct operated R 25402/05.0 Replaces: 10.05 /1 ype DBD Nominal sizes to 0 Component series 1X Maximum operating pressure 0 bar Maximum flow 0 l/min H5585 Overview of contents Contents
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationPressure relief valve, direct operated Type DBD
Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly echnologies neumatics Service Automation Mobile Hydraulics RE 25 402/06.02 Replaces: 03.98 Material No.: 00772632a ressure
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationBW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface
ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US
More informationVariable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design
Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationPRESSURE SEQUENCE VALVE TYPE UZK
PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set
More informationType Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN
Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used
More informationRE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.
Meter out pressure compensator Sandwich plate design Type SCA... /Series X Sizes 6, 5 up to 35 bar up to 35 L/min RE 9 47/.96 RE 9 47/.96 Replaces: 9.87 Sandwich plate design Load compensation in lines
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationSDM to 8 sections monoblock valve D1WWDA02A
SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information
More informationINVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:
direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting
More informationSi C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions
Safety valves for pressure relief in accordance to PED, DIN/EN and ASME Engineering GREAT Solutions Si C132 Features The universal compact safety valve > 3 body seat sizes for appropriate size selection
More informationModulating liquid level regulators, servo-controlled PMFL / PMFH and SV
MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, servo-controlled / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant,
More informationDual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series
Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each
More informationPRESSURE COMPENSATORS TECNORD
PRESSURE COMPENSATORS 2-way, Compensating / Reducing Valves GPM PSI LPM BAR MODEL CAVITY PAGE 8 3500 30 245 DF-CP2 7/8 14 UNF 60 16 3500 60 245 QC-CP2 Special 62 Typical Schematic Typical application for
More information4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...
4/3 Directional valve elements L8L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L8L1...(EDC-LV) RE 1831-17 Edition: 2.216 Replaces: 7.12 Size 6 Series Maximum
More informationPLD 03 T A CASAPPA S.p.A.
GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationType 4708 Supply Pressure Regulator
Type 708 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point range 0.5 to bar (8 to 90 psi) The pressure regulator
More informationDesiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21
Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.
More informationVPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control
VPPC, VPPC -ay proportional pressure control valve, > > Nominal diameter,, flange version G/ > > Visual function display (optional) > > Compact and lighteight design > > Field bus capable as part of a
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More informationLeak free Pipe Rupture Valve for Excavators
Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More informationList of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6
Úprava stlačeného vzduchu EWO VMA List of Contents System description Individual Units Pre-Filters 3 Micro-Filters 4 Activated-Charcoal-Filters 5 Combinations 6 Accessories and Main spare parts 6 Service
More informationDual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604
Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21
More informationDENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC
DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC Publ. 1 - EN0709 - A 01 / 2000 / 2500 / FB Replaces : 1 - EN 084 - B L25-10709 - 1 CONTENTS GENERAL CHARACTERISTICS T67GB T6GC - T6ZC T67GB
More informationF05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK
CONTINENTAL HYDRAULICS F05MSV-N* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400
More informationDisplacement 12, , Maximum flow rate (at 1450 rpm) bar.
00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment
More informationBUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-
BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut
More informationBL68 - Olympian Plus, plug-in system Filter/regulators and lubricators
>> Port size: 3/4... /2 (ISO G/ PTF) >> Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationGas Filters DN15 DN300. elektrogas.com EE151 06/13
FG Gas Filters DN15 DN300 elektrogas.com EE151 06/13 FG Gas Filters Contents Description.. 2 Features.. 2 Functioning and application. 3 Accessories and optionals 4 Technical specifications 4 Gas flow
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More information3-Way Pressure-Reducing Cartridge, Size 2 4
-Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationPressure-limiting valve and pre-load valve type MVG, MVE and MVP
Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Product documentation Directly controlled Operating pressure pmax: Flow rate Qmax: 700 bar 8 lpm D 3726 02-2016-1.3 by HAWE Hydraulik SE.
More informationPressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:
Pressure relief valve, direct operated Type DBD R 2542 dition: 21-7 Replaces: 214-8 Size 3 Component series 1X Maximum operating pressure 3bar [915 psi] Maximum flow 33 l/min [87 US gpm] H5585 Features
More informationInverse Proportional Pressure-Relief Cartridge, Size 10
Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size
More information