LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

Size: px
Start display at page:

Download "LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n"

Transcription

1 LMP Maximum pressure 8 bar F l o w r a t e s t o 6 l / m i n

2 Technical data Filter housing (Materials) Head: luminium Housing: ataphoresis Painting ypass valve: rass - luminium Pressure LMP length: Working pressure: 8 bar (8 MPa) Test pressure: bar ( MPa) urst pressure: 9 bar (9 MPa) Pulse pressure fatigue test:.. cycles with pressure from to 8 bar (8 MPa) Temperature From -5 to + ypass valve Opening pressure.5 bar ±% Other opening pressures on request. Δp Elements type Series N and W elements: bar Oil flow from exterior to interior. Seals Standard NR Optional FPM Weights (kg) LMP -,6 LMP -,8 LMP -, LMP -,6 series series V Volumes (dm ) LMP -,75 LMP -,8 LMP -, LMP -,5 onnections Inlet/Outlet In-Line LMP Inlet/Outlet In-Line + LMP second inlet port 9 Inlet/Outlet In-Line + LMP 6 second outlet port 9 Inlet/Outlet In-Line + LMP 8 outlet bypass port 9 Inlet/Outlet In-Line + LMP 9 outlet safety valve 9 ompatibility (to ISO 9) Housings compatible with: Mineral oils, synthetic fluids aqueous emulsions, water and glycol (series W required). The filter elements are compatible with: Mineral oils, synthetic fluids. queous emulsions, water and glycol (series W required).,75,5,5, NR seals series, compatible with: Mineral oils, synthetic fluids, aqueous emulsions and water and glycol. FPM seals series V, compatible with: Synthetic fluids type HS-HFR-HFS-HFU Recommended maximum flow rate => see page 5 Filter Element rea Filter element in stainless steel mesh Type U Values expressed in cm LMP LMP 8 Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of.86 kg/dm to ISO 968. Δp varies proportionally with density. LMP - Δp Housing / 8 6 LMP LMP 8

3 LMP LMP (plug not included) LMP 6 (plug not included),75 LMP - Δp Housing OUT / OUT LMP LMP,5,5, 8 6 LMP 6 - Δp Housing IN / - LMP 6,75,5,5, 8 6 Valves ypass valve pressure drop LMP - LMP - LMP 6-9 Valves ypass valve pressure drop LMP

4 LMP imensions 5 55,5,5 Ø 8 Indicator port 5, 6,5 6 5, H Min. 7 Indicator port (option) 6,6 Filter fixing holes LMP E E E E ouble filter fixing holes /8 UN x depth mm M x depth mm LMP Filter H mm St. E F onnections - G / G / NPT NPT SE SE 6

5 LMP LMP 6 St. E F onnections - G / G / NPT NPT SE SE 6 Lateral connections G / G / / NPT / NPT SE SE

6 LMP ,5,5 H 9 Ø 8 Min. 7 Indicator port 5, LMP 8 LMP 9 6,5 6 5, 6,6 LMP 8-9 H Filter mm St. E F onnections - G / G / NPT NPT SE SE 6 Lateral connection G / G / / NPT / NPT SE SE 5

7 Spare parts a b d c Item escription Q.ty FILTER Series LMP Filter assembly Filter element Seals Kit See order table See order table NR FPM a O-Ring for housing O-R Ø 78,97 x,5 b O-Ring for filter element O-R 5 Ø, x,5 c Seal for indicator NR FPM 58 6 d O-Ring for indicator O-R 5 Ø, x,78 Indicator connection plug TH TV - Indicators See order table 6

8 Filter assembly LMP Ordering information LMP Example: LMP N P Filter element U Example: U N P - Filter Filter element Filter length 6 - Indicator port No (excluded LMP 8-9) 6 + (excluded LMP 8-9) 7 - Filter element Inorganic microfibre* μ Inorganic microfibre μ 6 Inorganic microfibre 6 μ Inorganic microfibre μ 6 Inorganic microfibre 6 μ 5 Inorganic microfibre 5 μ * On request bsolute filtration Inorganic Microfibre ßx (c) - Valves S Without bypass (excluded LMP 8-9) With bypass With bypass Opening pressure: on request M5 M6 M9 P P5 Wire mesh Wire mesh Wire mesh Resin - Impregnated paper Resin - Impregnated paper Nominal Filtration Metal mesh Nominal Filtration ellulose - Filter seals V W 5 - onnection Type E F NR FPM NR (ompatible with fluid HF, HF, HF) On request MULTIPORT G / G / NPT SE SE Max filter element differential pressure N Δp bar 9 - Option P MP Filtri standard Pxx On request IFFERENTIL INITORS (see page ) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or commercial requirements. The colours of the products shown on the cover are purely guideline. opyright. ll rights reserved. 7

9 LMP 8 Maximum pressure 8 bar F l o w r a t e s t o l / m i n

10 Technical data Filter housing (Materials) Head: luminium Housing: ataphoresis Painting ypass valve: rass - luminium Pressure LMP // length: Working pressure: 8 bar (8 MPa) Test pressure: bar ( MPa) urst pressure: 8 bar (8 MPa) Pulse pressure fatigue test:.. cycles with pressure from to 8 bar (8 MPa) Filter Element rea Filter element in stainless steel mesh Type U Values expressed in cm LMP LMP Temperature From -5 to + ypass valve Opening pressure.5 bar ±% Other opening pressures on request. Δp Elements type Series N and W elements: bar LMP LMP Oil flow from exterior to interior. Seals Standard NR series Optional FPM Weights (kg) LMP -,9 LMP -, LMP -, LMP -,9 series V Volumes (dm ) LMP -,75 LMP -,8 LMP -, LMP -,5 Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of.86 kg/dm to ISO 968. Δp varies proportionally with density. ompatibility (to ISO 9) Housings compatible with: Mineral oils, synthetic fluids. queous emulsions, water and glycol (series W required). The filter elements are compatible with: Mineral oils, synthetic fluids. queous emulsions, water and glycol (series W required). NR seals series, compatible with: Mineral oils, synthetic fluids, aqueous emulsions and water and glycol. FPM seals series V, compatible with: Synthetic fluids type HS-HFR-HFS-HFU Recommended maximum flow rate => see page 5,75,5,5, LMP - - Δp Housing LMP LMP 8 6 9

11 LMP Type LMP Type Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of.86 kg/dm to ISO 968. Δp varies proportionally with density. LMP - Δp > >,75,5 LMP Type,5 8 6 ooler 6 LMP - Δp Housing with check valve bar setting ooler LMP Type 8 Type Type 8 6 Valves ypass valve pressure drop LMP /LMP 6 LMP - Δp Housing with check valve bar setting Type Type

12 LMP imensions 8 Indicator port 6 55 Indicator port H 9 Min. 7 LMP Filter H mm St. E F onnections - G / G / NPT NPT SE SE 6 Fixing holes M x depth mm M x depth mm /8 UN x depth mm /8 UN x depth mm /8 UN x depth mm /8 UN x depth mm

13 LMP - 8 Indicator port Min. 7 H 7 9 LMP - H Filter mm LMP Plug not Included St. F onnection - - G NPT SE 6 Fixing holes M x depth mm /8 UN x depth mm /8 UN x depth mm

14 Spare parts c d c d b b a a Item escription Q.ty FILTER Series LMP - - Filter assembly Filter element Seals Kit See order table See order table NR FPM a O-Ring for housing O-R Ø 78,97 x,5 b O-Ring for filter element O-R 5 Ø, x,5 c Seal for indicator NR FPM 58 6 d O-Ring for indicator O-R 5 Ø, x,78 Indicator connection plug TH TV - Indicators See order table

15 Ordering information LMP - Filter assembly LMP Example: LMP N P Filter element U Example: U N P - Filter Filter element - Filter length - Valve 6 - Indicator port Without indicator port With indicator port 7 - Filter element Inorganic microfibre* μ Inorganic microfibre μ 6 Inorganic microfibre 6 μ Inorganic microfibre μ 6 Inorganic microfibre 6 μ 5 Inorganic microfibre 5 μ * On request bsolute filtration Inorganic Microfibre ßx (c) S - Filter seals V W Without by-pass With bypass With by-pass Opening pressure: on request NR FPM NR (ompatible with fluid HF, HF, HF) On request M5 M6 M9 P P5 8 - Max filter element differential pressure N Wire mesh Wire mesh Wire mesh Resin - Impregnated paper Resin - Impregnated paper Δp bar Nominal Filtration Metal mesh Nominal Filtration ellulose 5 - onnection Type E F MULTIPORT G / (not for LMP ) G / NPT (not for LMP ) NPT SE (not for LMP ) SE Option P Pxx MP Filtri standard On request IFFERENTIL INITORS (see page ) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or commercial requirements. The colours of the products shown on the cover are purely guideline. opyright. ll rights reserved.

16 Filter assembly LMP Ordering information LMP Example: LMP N P Filter element U Example: U N P - Filter Filter element 5 - onnection Type F MULTIPORT G SE 6 - Filter length - Valves Type - Without bypass heck valve bar heck valve bar Type - Without bypass G heck valve bar H heck valve bar Type - With bypass M heck valve bar N heck valve bar Type - With bypass 6 - Indicator port Without indicator port With indicator port 7 - Filter element Inorganic microfibre* μ Inorganic microfibre μ 6 Inorganic microfibre 6 μ Inorganic microfibre μ 6 Inorganic microfibre 6 μ 5 Inorganic microfibre 5 μ * On request M5 Wire mesh M6 Wire mesh M9 Wire mesh P Resin - Impregnated paper P5 Resin - Impregnated paper bsolute filtration Inorganic Microfibre ßx (c) Nominal Filtration Metal mesh Nominal Filtration ellulose Q R heck valve bar heck valve bar 8 - Max filter element differential pressure N Δp bar - Filter seals NR V FPM W NR (ompatible with fluid HF, HF, HF) On request 9 - Option P Pxx MP Filtri standard On request IFFERENTIL INITORS (see page ) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or commercial requirements. The colours of the products shown on the cover are purely guideline. opyright. ll rights reserved. 5

17 LMP In-Line Suction and Return Filter 6 Maximum pressure 8 bar F l o w r a t e s t o 6 l / m i n

18 Technical data Filter housing (Materials) Head: luminium Housing: ataphoresis Painting ypass valve: rass - luminium Pressure LMP length: Working pressure: 8 bar (8 MPa) Test pressure: bar ( MPa) urst pressure: 8 bar (8 MPa) Pulse pressure fatigue test:.. cycles with pressure from to 8 bar (8 MPa) Filter Element rea Filter element in stainless steel mesh Type U Values expressed in cm LMP Temperature From -5 to + ypass valve Opening pressure.5 bar ±% Other opening pressures on request. Δp Elements type Series N and W elements: bar Oil flow from exterior to interior. Seals Standard NR Optional FPM Weights (kg) length LMP -,7 LMP -,9 LMP -, LMP -,7 Volumes (dm ) length LMP -,75 LMP -,8 LMP -, LMP -,5 series series V Filter housings Δp pressure drop The curves are plotted utilising mineral oil with density of.86 kg/dm to ISO Δp varies proportionally with density. LMP - Δp Housing > > 8 6 ompatibility (to ISO 9) Housings compatible with: Mineral oils, synthetic fluids. queous emulsions, water and glycol (series W required). The filter elements are compatible with: Mineral oils, synthetic fluids. queous emulsions, water and glycol (series W required). NR seals series, compatible with: Mineral oils, synthetic fluids, aqueous emulsions and water and glycol. FPM seals series V, compatible with: Synthetic fluids type HS-HFR-HFS-HFU 9 6 Valves ypass valve pressure drop LMP 8 6 7

19 - - E - F G - H bsolute filtration bsolute filtration,8,,8,,,,7, ,8, bsolute filtration 6,8, bsolute filtration 6,,,7, bsolute filtration 5 bsolute filtration 5,8,,8,,,,7, Filter length

20 imensions LMP Indicator 8 port Min. 7 H 9 7 LMP Filter H mm St. F onnection - - G SE 6 Fixing holes M x depth mm /8 UN x depth mm

21 Spare parts d c b a Item escription Q.ty FILTER Series LMP Filter assembly Filter element Seals Kit See order table See order table NR FPM a O-Ring for housing O-R Ø 78,97 x,5 b O-Ring for filter element O-R 5 Ø, x,5 c Seal for indicator NR FPM 58 6 d O-Ring for indicator O-R 5 Ø, x,78 Indicator connection plug TH TV - Indicators See order table

22 LMP - - E - F LMP G - H Pump Return Tank Tank Return Pump Symbols LMP E LMP G LMP LMP F LMP H LMP

23 Filter assembly LMP Ordering information LMP Example: LMP N P Filter element U Example: U N P - Filter Filter element - Filter length - Valves 6 - Indicator port No Port G /8 switch For pressure switch Port G / For pressure switch ifferential indicator port 7 - Filter element 6 5 Inorganic microfibre μ Inorganic microfibre 6 μ Inorganic microfibre 5 μ bsolute filtration Inorganic Microfibre ßx (c) E F G H see SYMOLS (ref. to page ) 8 - Max filter element differential pressure N Δp bar 9 - Option P MP Filtri standard Pxx ustomer request - Filter seals V W NR FPM NR (ompatible with fluid HF, HF, HF) On request 5 - onnection Type F MULTIPORT G SE 6 IFFERENTIL INITORS (see page ) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or commercial requirements. The colours of the products shown on the cover are purely guideline. opyright. ll rights reserved.

24 Symbols MULTIPORT LMP LMP LMP LMP 6 LMP 8 In-Line filter In-Line filter ouble IN port In-Line filter Lateral IN port In-Line filter Lateral OUT port In-Line filter ypass lateral. lways cleaning fluid in OUT port LMP 9 LMP LMP In-Line filter Safety valve 6 bar for heat exchanger In-Line filter Port IN-OUT on the same side In-Line filter Lateral OUT port high flow LMP Type LMP Type ooler In-Line filter ypass valve for heat exchanger high flow ooler

25 Recommended maximum flow rate MULTIPORT Recommended maximum flow rate - Pressure drop of filter assembly equal to Δp.7 bar. - Oil kinematic viscosity mm /s (cst). - ensity.86 kg/dm. Filtration P P5 M5 LMP Filtration P P5 M5 LMP Filtration P P5 M5 LMP Filtration P P5 M5 LMP Filtration P P5 M5 LMP

Flow rates to 200 l/min

Flow rates to 200 l/min LMP MULTIPORT - - Maximum pressure bar low rates to l/min Technical data ilter housing (Materials) Head: luminium Housing: ataphoresis-painted Steel ypass valve: rass - luminium Pressure Working pressure:

More information

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I. LMP 900-90 Filter element in according to D 550 Style S Style D.I. D.I. Maximum pressure 30 bar F l o w r a t e s t o 0 0 0 l / m i n 6 Technical data Filter housing (Materials) Head: nodised luminium

More information

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 1 bar Flow rates to l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for both

More information

M a x i m u m f l o w t o l / m i n

M a x i m u m f l o w t o l / m i n SERIES M a x i m u m f l o w t o 0 0 l / m i n Technical data MRS 116 165 166 Filter housing (Materials) Head: luminium over: Nylon (MRS 116) luminium (MRS 165166) owl: Nylon Filter housing (Materials)

More information

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters Suction fi lters SF 5 series Flow rate up to 8 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 8 l/min, up to 35 bar 3 6 4 6 4 8 33 5 66.x 66.x 99.x 3.x 3 3.x 64 3.x 396 3.x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed

More information

D e s c r i p t i o n

D e s c r i p t i o n MPS Series D e s c r i p t i o n The MPS spin-on filter series is a complete product range suitable, for both suction and return applications. Utilising spin-on canisters, the MPS series are quick and

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min Return Filters E E E 6 E 6 E 7 Tank mounting Nominal flow rate up to 8 l/min Description Application In the return line circuits of hydraulic systems. Performance features Protectionagainst wear: By means

More information

Spin-On Filters SSF 24,25

Spin-On Filters SSF 24,25 Spin-On Filters SSF,5 Technical Specification Construction Die cast aluminium head Seals NBR (Buna-N ) Port connections Flow rate Working pressure Operating temperature By-pass valve Clogging indicators

More information

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min Return Filters E E Tank top mounting Connection up to G¼ ominal flow rate up to l/min Description pplication In the return line circuits of hydraulic systems. Performance features Protection against wear:

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER PM Pressure Filters MEDIUM PREURE INLINE FILTER Pressure Filters PM PM MPa (0 bar) Port sizes: 1/ 1 Flow rates: 10 l/min TECHNICAL DATA Max. working pressure: MPa (0 bar) Max. test pressure: MPa (0 bar)

More information

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:

More information

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min Pressure Filters D D 6 In-line mounting Operating pressure up to 1 bar Nominal flow rate up to 9 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note

More information

Directional Control Valves Technical Information Model 1500

Directional Control Valves Technical Information Model 1500 Single spool monoblock valve. 26.4 l/min [7 US gal/min] maximum flow. 138 bar [2 psi] maximum pressure with relief. 27 bar [3 psi] maximum pressure without relief. Garden tractors, mowers, utility equipment,

More information

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

SUCTION FILTERS. BYPASS VALVE Setting: 30 kpa (0,30 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

SUCTION FILTERS. BYPASS VALVE Setting: 30 kpa (0,30 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C COMPONNTS SUCTION ILTRS S MATRIALS Head: Aluiniu alloy Spinon cartridge: Steel ypass valve: Polyaide Seals: NR Nitrile (KM on request fl uoroelastoer) Indicator housing: rass APPLICATION XAMPL PRSSUR (ISO

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

Principles of Filtration. Filter Elements. High Pressure Filters. Section 4. Tank-Mounted, Return Line and Medium Pressure Filters

Principles of Filtration. Filter Elements. High Pressure Filters. Section 4. Tank-Mounted, Return Line and Medium Pressure Filters Principles of Filtration s High Pressure s Section 4 Tank-, Return Line and Medium Pressure s Water Service s Reservoir Accessories SCHROEDER INDURIES 125 Principles of Filtration s Section 4 Section 4

More information

Check valve hydraulically pilot operated

Check valve hydraulically pilot operated Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa Max. operating pressure

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

LMU100/200 Series. Standard Specifications

LMU100/200 Series. Standard Specifications Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content

More information

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting REDUING (ND HEK) VLVES RT/RG RT/RG -3// (3/8, 3/, -/) Threaded onnections / Mounting Up to MPa (5 PSI), 5 L /m in (3 U.S.GPM) Pub. E-3 Pressure Reducing Valves Pressure reducing valves are used to set

More information

2-port and 3-port seat valves, PN16

2-port and 3-port seat valves, PN16 s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections

More information

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm DFDK Series Inline Duplex Filters 4568 psi up to 9 gpm Hydraulic Symbol DFDK QL L Ball Valve A DFDK QT T Ball Valve (sizes 33 or larger) A B B Features The DFDK Filters have a filter head of ductile iron

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated Pressure relief valve, direct operated RE 570/0.05 Replaces: 06.03 /8 Type DBD..K Size Component series X Maximum operating pressure 500 bar Maximum flow 0 l/min K9- Table of contents Contents Page Features

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4) IN-LIN HK VLVS IT- / 3 / / (/,3/8,3/,-/) RIGHT NGL HK VLVS RT / RG-3 / / (3/8,3/,-/) Up to 5 MPa (33 PSI), 3 L/min (33 U.S.GPM) Pub. - IRTIONL ONTROLS These valves allow free flow in one direction and

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

Monoblock Directional Control Valve RMB 202

Monoblock Directional Control Valve RMB 202 Monoblock Directional Control Valve RMB 202 Key valve features RMB 202 is a 2-section mono block valve, especially designed for front-end loaders. The valve is prepared for quick connecting couplings,

More information

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW ILTRS YRAULI IVISIO TAK AR - Return filters R TIAL ATA ORRIG A OPTIOS ART LOGGIG IIATORS PRSSUR ROP ( p) URVS ROSS UTIOAL VI SPAR PARTS ORRIG IORMATIO IMSIOS O T ILTR LMT ILTRS YRAULI IVISIO R TAK AR RTUR

More information

hyprofiltration.com/fsw

hyprofiltration.com/fsw A compact, dedicated off-line contamination solution ideal for small reservoirs, gearboxes and diesel engine crankcase conditioning. Element media options for every application including particulate removal,

More information

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to RV* FH1 G G B FH Specifications Descriptions Cylinder bore size Working fluid Max. working pressure Min. working pressure Ambient temperature Port size Operational stroke length Rod diameter Capacity of

More information

2-port and 3-port valves PN 16

2-port and 3-port valves PN 16 OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port

More information

Digital directional & flow control valves D-DF(R)G

Digital directional & flow control valves D-DF(R)G Digital directional & flow control valves D-DF(R)G Functional Symbols Model Code D-DFG- D-DFG-~ D-DFRG-/ D-DFG--C--- Digital directional & flow control valve Size Spool type (neutral position) : ll ports

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated ressure relief valve, direct operated R 25402/05.0 Replaces: 10.05 /1 ype DBD Nominal sizes to 0 Component series 1X Maximum operating pressure 0 bar Maximum flow 0 l/min H5585 Overview of contents Contents

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE MAIN CHARACTERISTICS The stainless steel LPRV elite low pressure reducer is intended for the pressure reduction of the fluids such as water, air, clear liquids not in charge of and the compatible gases

More information

Hand & mechanical directional valves

Hand & mechanical directional valves www.atos.com Table E5-3/E Hand & mechanical directional valves ISO 44 sizes 6,, 6 and 25 H- Hand & mechanical operated directional valves are spool type, three or four way, two or three position valves,

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

CK Series. 3-way jaw long stroke chuck double acting/single acting. Operational stroke length: 20, 40mm. Specifications. Switch specifications

CK Series. 3-way jaw long stroke chuck double acting/single acting. Operational stroke length: 20, 40mm. Specifications. Switch specifications RV* G G A S F J H2 LB2 N/ S/F Specifications Size Cylinder bore size Actuation Working fluid Max. working pressure Min. working pressure Ambient temperature Port size MPa MPa C Operational stroke length

More information

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

DN 3/8 to 4 Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female Size : Ends : Min Temperature : Max Temperature : DN 3/8" to 4" Female BSP - 10 C + 120 C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female Materials :

More information

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION 2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems

More information

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

DN 1/2 to 2 Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2" Female BSP + 0 C + 120 C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve Materials

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series NEWS 66 Components for Pneumatic Automation VALVES & AIR SERVICE UNITS STEEL LINE Series www.pneumaxspa.com Valves General The new Steel line valve series was created and developed specifically for the

More information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the

More information

Damcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04

Damcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04 Damcos PHP 25-05 Portable hand pump unit 5 l Product Data Sheet September 2014 SD 6601-2E04 TM Damcos PHP 25-05 September 2014 General description Double-acting portable hand pump incl. 5 l. reservoir

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 300 Flanges R.F. PN10/16-10 C + 80 C Max Pressure : 16 Bars up to DN200 Specifications : Removable stainless steel filter Bolted bonnet with

More information

Materials : Forged carbon steel A105N

Materials : Forged carbon steel A105N Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 2 Female - Female BSP or NPT, Socket Welding - 29 C + 425 C Max Pressure : 136 Bars (Class 800) Specifications : With draining

More information

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve Flow Control Valves Series MTK, MTQ, MTC MTQ... MTC... robust, uncomplicated, reliable these valves do not require maintenance. This lowers costs and reduces the risk of a system failure. can be provided

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

Desde1963. Válvulas Pilotadas. Proveedor Integral. la Industria

Desde1963. Válvulas Pilotadas. Proveedor Integral. la Industria esde96 Válvulas Pilotadas Proveedor Integral de Por Soluciones Aire para la Industria Otras válvulas de proceso Cuerpos de Bronce, hierro fundido y conexión bridada, para completar la gama de soluciones.

More information

Forged stainless steel ASTM A182 F316

Forged stainless steel ASTM A182 F316 MADE OF STAINLESS... Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 8 to 25 (NPS 1/4" to 1") Female - Female NPT - 29 C + 538 C Max Pressure : 138 Bars (Class 800) Specifications

More information

Industrial Filters Selection 1

Industrial Filters Selection 1 election electing the electing the seal electing the housing electing the Narrow down the types according to the operating environment, filtration level and usage. Filtration level: Nominal filtration,

More information

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type. Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Plug-In Motor A2FE www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in

More information

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders ENGINEERING DT PV Piston Pumps Same Day Shipments of Units or Part Orders Interchangeable Parts Fully Tested w w w. F l u i D y n e F P. c o m Email:cs@FluiDyneFP.com Contents asic characteristics.........................................................................................

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

2-way flow control valve Model 2FRM 6

2-way flow control valve Model 2FRM 6 R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D

More information

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min. Flow Control These are pressure and temperature compensating type valves and maintain a constant flow rate independent of change in system pressure (load) and temperature (Viscosity of the fluid). They

More information

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Size

More information

Tank-Mounted Suction Filter

Tank-Mounted Suction Filter Tank- Suction 20 gpm 75 L/min 6.25 MAX. (159) OPTIONAL DI ALARM OR ELECTRIC SWITCH 4.06 MAX. (103) 1.88 (48).12 (3) THICK GASKET 5.06 (129) Ø HOLE TANK FOR ALLATION 6.38 PO TO PO (162) 45 TYP.44 (11) Ø

More information

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2 FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel L Compact /, High Flow / - / Air service equipment Series FEATURES Stainless Steel filter, regulator and filter regulator intended for corrosive environment

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

PRESSURE SEQUENCE VALVE TYPE UZK

PRESSURE SEQUENCE VALVE TYPE UZK PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set

More information

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC Publ. 1 - EN0709 - A 01 / 2000 / 2500 / FB Replaces : 1 - EN 084 - B L25-10709 - 1 CONTENTS GENERAL CHARACTERISTICS T67GB T6GC - T6ZC T67GB

More information

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications RV* FH1 G B FH G A S Specifications Descriptions Size Cylinder bore size mm Working fluid Max. working pressure MPa Min. working pressure MPa Ambient temperature C Port size Operational stroke length mm

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX

MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX This new range of multiple ejector vacuum generators represents the natural evolution of the PVP 12M and 25M generators. In fact, given the same air consumption

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

Materials : Carbon steel ASTM A216 WCB

Materials : Carbon steel ASTM A216 WCB Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 50 to DN 400 ( NPS 2" to 16" ) Flanges R.F. Class 150 (PN20) - 29 C + 425 C Max Pressure : 20 Bars Specifications : Removable stainless

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Two-stage valve type NE

Two-stage valve type NE Two-stage valve type NE Product documentation Operating pressure pmax: Flow rate Qmax: 700 bar (High pressure) 80 bar (Low pressure) 25 lpm (High pressure) 180 lpm (Low pressure) D 7161 03-2017-1.0 by

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91 1 for open and closed circuits Sizes 22...5 Series 1, Series 3 Nominal pressure up to bar Peak pressure up to 45 bar Index Features 1 Ordering

More information

FILTRATION TECHNOLOGY STAUFF. Spin On Filters. Quality and Service Worldwide

FILTRATION TECHNOLOGY STAUFF. Spin On Filters. Quality and Service Worldwide FILTRATION TECHNOLOGY 2 STAUFF Spin On Filters Quality and Service Worldwide Spin-On Filters Australia Stauff Corporation (Pty.) Ltd. P.O.Box 227, 2-2 Doyle Avenue, Unanderra Wollongong, N.S.W 252 AUSTRALIA

More information

Pilot Check Valve: Metal Body Type

Pilot Check Valve: Metal Body Type INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not

More information

BS ml Bottle Sampling Unit

BS ml Bottle Sampling Unit BS500 500ml Bottle Sampling Unit User Guide www.mpfiltri.co.uk 200.307-EN Covers Model Numbers BS500 SAFETY WARNING Hydraulic systems contain dangerous fluids at high pressures and temperatures. Installation,

More information

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Product documentation Directly controlled Operating pressure pmax: Flow rate Qmax: 700 bar 8 lpm D 3726 02-2016-1.3 by HAWE Hydraulik SE.

More information

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking: direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting

More information

VFPIP/VFPIM/VFPI 15-25

VFPIP/VFPIM/VFPI 15-25 VFPIP/VFPIM/VFPI N 15-25 revision 12 2016 VFPIP/VFPIM/VFPI 15-25 Pressure independent control valves, N15-N25 with integrated flow limiter for thermal emitters and differential pressure regulator VFPIP/VFPIM/VFPI

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information