Evidence of Performance. Class 4. Class 5A. Class C5 / B5. Test Report No PR01. ift Rosenheim

Similar documents
ETEM S.A. LIGHT METALS COMPANY 1, IROON POLYTEHNIOU STR. GR MAGOULA ATTIKIS GREECE

OS2 F R A M E S E R I E S

TEST REPORT TS EN : TS EN A1 Windows and doors - Product standard. Testing Reference. : BM 72 Gizli Kanat Pencere (Hidden Vent Window)

ETEM S.A. LIGHT METALS COMPANY 1, IROON POLYTEHNIOU STR. GR MAGOULA ATTIKIS GREECE

Test Report. Test Report Smart Systems Limited Incorporating Smart Extrusions. Page 1 of 78

TEST CERTIFICATE PARTIAL REPRODUCTION OF THE PRESENT CERTIFICATE IS PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION BY EKANAL.

Intertek Testing Services Building Products. Enterdoor AB ubv

TEST CERTIFICATE THE RESULTS CONCERN ONLY THE SPECIMEN TESTED. THE PRESENT DOCUMENT DOES NOT CONSIST PRODUCT APPROVAL BY E.K.AN.AL.

Slide and Turn System SF35

CE conform applications according to EN Windows without thermal break Systems Forster presto and Forster norm

Slide and Turn System SF25

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A STRUCTURAL PERFORMANCE TEST REPORT SUMMARY RENDERED TO:

Kestrel Aluminium Systems Limited. Product Manual Section 10 Thermal Framing System. Manual Version

CONTENTS 1. INTRODUCTION DESCRIPTION OF TEST SAMPLE TEST RIG GENERAL ARRANGEMENT TEST SEQUENCE...7

IGUMA - IGU Design Limitations

The following drawings are concerned of this measure, which will be considered in the next revision of the documents as well as in LogiKal.

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

Technical Report. Title: Product weathertightness testing of a sample of W.G.Ltd 500 series Curtain Walling for The Window Glass Company Limited

COBALT BULLETPROOF PRODUCTS. Architect: J.-L. Bonnet Photography: Serge D ly

FEATURES. Welded Sash and Main Frame. Swiggle or DuraSeal Spacer System on Fixed Units. 3-1/4" Frame Depth. True Sloped Sill. Integral J Channel

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

TABLE OF CONTENTS International Racquetball Federation officially approved specifications. Copyright 01/13/1983; rev.

DECLARATION OF PERFORMANCE

DK46 - DK800 Supplementary instructions

H11.13 PIVOTS SERIES 490 H11 HORIZONTAL AND VERTICAL PIVOT WINDOWS

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

RMANCE ROCKPANEL. System 1. inorganic finish. english. - vs01. Konstruktieweg. Tel. Fax. Notified. Body: 1. Unique. 4. System as set.

Hatch cover securing and tightness

ASTM E1886 and ASTM E1996 TEST REPORT. Report No.: E Rendered to: 3M COMPANY St. Paul, Minnesota 55144

FLUID - Panic Exit Device

EN1279 part 3 assessment of insulating glass: IGU with Duralite sealant

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

DOUBLE SAFETY: NO PANIC, NO BACTERIA

TECHNICAL SPECIFICATION

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

LATICRETE International Inc. One LATICRETE Park North Bethany, CT USA

Compact pressure switches for gas and air

SMOKE CONTROL DOORS AND SHUTTERS

Pressure release of insulating glass units (IGU)

Types and approvals. Page 1/6. Data Sheet

CR Series. Special doors for clean room application

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

CYCLIC PERFORMANCE PER ASTM E 330 TEST REPORT. Rendered to: TRUSEAL TECHNOLOGIES, LTD. PRODUCT TYPE: Fixed Window

Friction Stays: for PVC, timber and aluminium windows HIGH PERFORMANCE

Performance Standards for Non-Turf Cricket Pitches Intended for Outdoor Use [TS6] ecb.co.uk

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

STABILITY AND WATERTIGHT INTEGRITY, CLOSING APPLIANCES

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

EADIPS /FGR STANDARD

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

Guidelines to the standard IEC60601

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

Valve Inspection & Testing

ASSEMBLY INSTRUCTIONS S O L O N STANDARD MODULES

PART 3 HULL INTEGRITY AND ARRANGEMENT

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

OCEAN - Wellness Line

QUANEX BUILDING PRODUCTS TEST REPORT

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

1688 Jean-Berchmans-Michaud Drummondville, Quebec. J2C 8E9. Mr. Marc-Etienne Mathieu,ing.

Inverse Proportional Pressure-Relief Cart., Size 2 4

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Underwater Blanking Tools. Miko Plaster. Tanker Kit. Sea Chest Blanking. Pipe Plugs

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Technical information for hinges

Overview ASTATT3. Carry out air tightness testing for single dwellings and other small buildings

IECEx Certificate of Conformity Annexe

Evaluation of n-situ easurement ethods for ir ermeability of indows

OPERATING INSTRUCTIONS

Instruction and Maintenance Manual

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

Declaration of Conformity as per Directive 97/23/EC

Pneumatic Target Transfer System Model PT01

Discussion and guidance on the definition and qualification of porous loads

3M InCa Individual Cross-Connection Cabinets

OPENINGS AND REINFORCEMENTS 26

Pressure reducing valve, direct operated

Testing Procedures of Watertight Compartments

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

VINAYAK PHARMA TECHNOLOGY

INTERNATIONAL FLYING FIFTEEN CLASS MEASUREMENT FORM

Instruction and Maintenance Manual

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

BDT20 Safety process pressure gauge 100 & 160mm

Intertek Testing Services Taiwan Ltd.

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices

2-step solenoid valve Type ICLX

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Pressure regulating valves Types OFV, OFV-SS

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

The number of test stands can be adapted to the special requirements.

Instruction manual. HLSD-2 Circular Access Tank Cover IM-TE91K041-EN1 ESE Date of issue: August 29, 2012

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

Transcription:

Evidence of Performance Test Report No 16-002359-PR01 (PB-A01-02-en-01) Client Product Designation Performance-relevant product details Overall dimensions (W x H) Special features - / - SUNCE Marinkovic d.o.o. Lepenicki bulevar br.39 34 000 Kragujevac Serbia Tilt and turn window System designation: REHAU Synego MD Material: PVC/U-white 1,230 mm x 1,480 mm Basis EN 14351-1:2006+A1:2010 Test standard/s: EN 1026:2000-06 EN 1027:2000-06 EN 12211:2000-06 Correspond/s to the national standard/s (e.g. DIN EN) Representation Results Air permeability according to EN 12207:1999-11 ift Rosenheim 14.02.2017 Class 4 Watertightness according to EN 12208:1999-11 Class 5A Resistance to wind load according to EN 12210:1999-11/AC:2002-08 Class C5 / B5 Michael Breckl-Stock, M.Eng., Dipl.-Ing. (FH) Deputy Head of Testing Department Construction Product Testing Robert Kolacny, Dipl.-Ing. (FH) Operating Product Officer Building Components Instructions for use The manufacturer is allowed to use the results obtained for preparing a Declaration of Performance in accordance with the Construction Products Regulation 305/2011/EC. Observe the specifications set out by the applicable product standard. Validity The data and results refer solely to the tested and described specimen. Classification remains valid as long as the product and the above basis remain unchanged. The results can be extrapolated under the manufacturer's own liability subject to observance of the relevant specifications set out by the applicable product standard. This test/evaluation does not allow any statement to be made on any further characteristics regarding performance and quality of the construction presented; in particular the effects of weathering and ageing were not taken into account. Notes on publication The ift-guidance Sheet "Advertising with ift test documents" applies. The cover sheet can be used as an abstract. The report contains a total of 24 pages. Ve-Prü-2087-en 01.06.2016

Evidence of Performance Page 2 of 14 1 Object 1.1 Description of test specimen Product Manufacturer, manufacturing plant Tilt and turn window Date of manufacture 30.11.2016 Profile system SUNCE Marinkovic d.o.o. REHAU Synego MD Type of opening / opening direction tilt and turn, DIN right inward opening Frame material PVC/U white Overall frame dimensions (W x H) 1,230 x 1,480 Overall sash dimensions (W x H) Right sash weight Frame member Designation / Type / Item No. Frame joint Sash member Designation / Type / Item No. Frame joints Supplementary parts Rebate design Rebate drainage Pressure equalisation Infill panel Type / manufacturer Total thickness 1,133 mm x 1,383 mm 68.2 kg further details are given in drawings 1537445 with reinforcing profile 1357542, 23 x 38 x 1.5 mm, 82 x 80 mm mitred and welded further details are given in drawings 1537215 with reinforcing profile 1244526, 35 x 28 x 2 mm, 79 x 80 mm mitred and welded glazing bar 1560311, mitred, clipped 3 slots 5 mm x 28 mm inside rebate, 25 and 30 mm from internal edge of frame to outside front 2 slots 5 mm x 31 mm, 150 and 160 mm from external edge of frame, with cover caps 12615821012 2 slots 5 mm x 26 mm inside rebate, 25 and 30 mm from internal edge of frame to outside 2 slots 5 mm x 31 mm, 135 and 145 mm from external edge of frame insulating glass unit (IGU) triple IGU 46 mm Configuration 3.3.1 CGSolar / 14 thermix / 4 extra clear / 14 thermix / 3.3.1 CGPremium Incorporation of infill panel Vapour pressure equalisation Glazing gasket, external Designation / Type / Item No. PREN 601 Manufacturer Material Glazing gasket, internal at bottom and top 2 slots 5 mm x 30 mm, 105 and 115 mm from external edge of sash Rehau PREN Designation / Type / Item No. PREN 707 Manufacturer Rehau

Evidence of Performance Page 3 of 14 Material PREN External rebate seal frame Designation / Type / Item No. PREN 601 Manufacturer Rehau Material PREN Corner design mitred and welded External rebate seal sash Designation / Type / Item No. PREN 707 Manufacturer Rehau Material PREN Corner design mitred and welded Centre seal Designation / Type / Item No. PREN 601 Manufacturer Rehau Material PREN Corner design mitred and welded Hardware Type / manufacturer tilt and turn hardware, Siegenia Titan AF RC2 Hinges / bearings/pivots 1 tilt mechanism pivot, 1 corner pivot Number of locking devices at bottom 3, at top 2, on hinge side 3, on lock side 3 Locking distance, max. in mm 685 mm Position of locking devices neutral The description is based on information provided by the client and inspection of the test specimen at the ift (item designations / numbers as well as material specifications were provided by the client unless stated "ift-checked ). Test specimen representations are documented in the Annex "Representation of product/test specimen. The design details were examined solely on the basis of the characteristics / performance to be classified. The drawings are based on unchanged documentation provided by the client unless stated otherwise. The photographs were taken by the ift Rosenheim unless stated otherwise. 1.2 Sampling The below sampling data were provided to the ift: Sampling by: SUNCE Marinkovic d.o.o., 34000Kragujevac (Serbia) Date: 30.11.2016 Verification: Delivered on: 12.12.2016 ift specimen No: 16-002359-PK01 A sampling report has been provided to the ift.

Evidence of Performance Page 4 of 14 2 Procedure 2.1 Basis*) referring to methods Testing EN 1026:2000-06 Windows and doors - Air permeability - Test method EN 1027:2000-06 Windows and doors - Watertightness - Test method EN 12046-1:2003-11 Operating forces - Test method - Part 1: Windows EN 12211:2000-06 Windows and doors - Resistance to wind load - Test method Classification / Evaluation EN 12207:1999-11 Windows and doors - Air permeability - Classification EN 12208:1999-11 Windows and doors - Watertightness - Classification EN 12210:1999-11/AC:2002-08 Windows and doors - Resistance to wind load - Classification *) and the equivalent national versions, e.g. DIN EN

Evidence of Performance Page 5 of 14 2.2 Brief description of procedure Air permeability - EN 1026 Prior to testing, the operating forces are determined as per EN 12046-1 for the release / locking operation of the hardware. Air permeability is tested in accordance with EN 1026 and conducted in steps at negative pressure and positive pressure up to the maximum test pressure difference. Leakages of the test set-up are made visible using artificially generated fog and sealed using permanently resilient sealant. The test specimen is exposed to three pressure pulses pmax + 10 % or at least 500 Pa. This is followed by measurement of air permeability for the respective pressure steps. + Pa 3 if required 0 1 Time (sec.) - Pa opening and closing Illustration Test sequence for air permeability

Evidence of Performance Page 6 of 14 Resistance to wind load - Deflection and alternating negative/positive pressures - EN 12211 Resistance to wind load is tested in accordance with EN 12211 and conducted in steps at negative pressure and positive pressure up to the test pressure p 1. The test specimen is exposed to three pressure pulses p 1 + 10 %. This is followed by determination of the frontal deflection of test specimen for each pressure step when exposed to positive test pressure p 1 and negative test pressure p 1. Then the test specimen is subjected to 50 cycles including negative and positive pressures of ± p 2 = p 1-50 %. Positive pressure P 1+10% 30±10 s 50 Cycles P 1 7±3 s P 2 60±5 s 0 -P 2 Stepwise or continuous increase in pressure, max. 100 Pa/s 7±3 s Time -P 1 P 1+10% 30±10 s 7±3 s Negative pressure Illustration Test sequence for resistance to wind load Air permeability Repeat test - EN 1026 Following resistance to wind load test for p 1 (deflection) and p 2 (alternating positive/negative pressure), air permeability must not exceed by more than 20% the upper limit of the specified class as set out by EN 12207.

Evidence of Performance Page 7 of 14 Watertightness - EN 1027 Watertightness is tested in accordance with EN 1027 up to the maximum test pressure difference. The external face of the test specimen is subjected to constant spraying of water by an upper row of nozzles at a flow rate of approx. 2 l/min per nozzle while increments of positive test pressure are applied at regular intervals. For test specimen exceeding 2.50 m in overall height, additional rows of nozzles are fixed at vertical intervals at 1.5 m below the top nozzle line. The water flow rate of the additional nozzle rows is approx. 1 l/min per nozzle. P ( Pa ) 750 600 500 450 400 300 200 150 100 50 0 Illustration 5 10 15 20 25 30 35 40 45 50 55 Test sequence for watertightness Time (min)

Evidence of Performance Page 8 of 14 Resistance to wind load Safety test - EN 12211 The wind resistance test (safety test) is conducted at negative pressure and positive pressure in accordance with EN 12211 up to test pressure p 3 = p 1 + 50 %. Positive pressure 7±3 s P 3 7±3 s 7±3 s 0 Time -P 3 Negative pressure Illustration Test sequence for safety test

Evidence of Performance Page 9 of 14 3 Detailed results

Evidence of Performance Page 10 of 14

Evidence of Performance Page 11 of 14

Evidence of Performance Page 12 of 14

Evidence of Performance Page 13 of 14

Evidence of Performance Page 14 of 14

Annex 1: Representation of product/test specimen Page 1 of 10 Evidence of Performance Drawing 1 Test specimen

Annex 1: Representation of product/test specimen Page 2 of 10 Evidence of Performance Drawing 2 Horizontal section

Annex 1: Representation of product/test specimen Page 3 of 10 Evidence of Performance Drawing 3 Vertical section

Annex 1: Representation of product/test specimen Page 4 of 10 Evidence of Performance Photo 1 Test specimen on test rig window closed Photo 2 Test specimen on test rig window open Photo 3 Rebate drainage Photo 4 Rebate drainage Photo 5 Rebate drainage Photo 6 Rebate drainage

Annex 1: Representation of product/test specimen Page 5 of 10 Evidence of Performance Photo 7 Rebate drainage Photo 8 Rebate drainage Photo 9 Rebate drainage Photo 10 Rebate drainage Photo 11 External rebate seal, corner design Photo 12 External rebate seal

Annex 1: Representation of product/test specimen Page 6 of 10 Evidence of Performance Photo 13 Centre seal, corner design Photo 14 Centre seal Photo 15 Internal rebate seal, corner design Photo 16 Internal rebate seal Photo 17 Pressure equalisation Photo 18 Pressure equalisation

Annex 1: Representation of product/test specimen Page 7 of 10 Evidence of Performance Photo 19 Pressure equalisation Photo 20 Pressure equalisation Photo 21 Pressure equalisation Photo 22 Pressure equalisation Photo 23 Pressure equalisation Photo 24 Pressure equalisation

Annex 1: Representation of product/test specimen Page 8 of 10 Evidence of Performance Photo 25 External glazing gasket, corner design Photo 26 External glazing gasket Photo 27 Internal glazing gasket, corner design Photo 28 Internal glazing gasket Photo 29 View of horizontal glazing rebate Photo 30 Vapour pressure equalisation

Annex 1: Representation of product/test specimen Page 9 of 10 Evidence of Performance Photo 31 Vapour pressure equalisation Photo 32 Vapour pressure equalisation Photo 33 Vapour pressure equalisation Photo 34 Vapour pressure equalisation Photo 35 Tilt mechanism pivot, seen from inside Photo 36 Tilt mechanism pivot, seen from rebate

Annex 1: Representation of product/test specimen Page 10 of 10 Evidence of Performance Photo 37 Corner pivot, seen from inside Photo 38 Corner pivot, seen from rebate Photo 39 Locking situation, frame / sash 1 Photo 40 Locking situation, frame / sash 1 Photo 41 Locking situation, frame / sash 2 Photo 42 Locking situation, frame / sash 2