HIGH PRESSURE DRILLING FLUID PUMP

Similar documents
Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

OWNER S TECHNICAL MANUAL

DIAPHRAGM PUMP MODEL PDM 1-175

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Directional Control Valves Technical Information Model 1500

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Series IRV1000/2000/3000

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Leak free Pipe Rupture Valve for Excavators

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

GROUTEC SCOTT VICKERS. Grouting Equipment

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Fixed Displacement Pump KFA for commercial vehicles in open circuits

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Direct Operated Precision Regulator Modular Style. Standard Specifications

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

30T A/Manual Hydraulic Shop Press

Code AWC20HP Air Compressor

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Axial piston pumps type PVC

Unit 24: Applications of Pneumatics and Hydraulics

Axial piston pumps type PVC

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Hydraulic Reliability & Preventive Maintenance Report

Related Products: Auto Drain Valve. Model/Specifications. Model

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Double Pilot Operated Cartridge Check Valve, Size 8

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

INTENDED USE TECHNICAL SPECIFICATIONS

Workshop Compressors CLASSIC Series

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

Fixed Displacement Plug-In Motor A2FE

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Pressure Dump Valve Service Kit for Series 2300 Units

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

INSTALLATION OPERATION MAINTENANCE

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Air Amplifiers & SYSTEMS

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Instruction Manual. AlfaLavalSBAntiVacuumValve ESE02960-EN Original manual

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

PRESSURISED PAINT CONTAINER

Pump Relief, Pressure Tank/

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

TITAN FLOW CONTROL, INC.

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

VB85/ Pressure regulating valve (Unloader)

CAST IRON SAFETY VALVE TYPE 6301

200 PSI COMPRESSORS - MODEL NUMBERS

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

FIREFIGHTING EQUIPMENT

Maintenance handbook

Pressure reducing valve, pilot operated, Model 3DR

Booster Regulator/Air Tank

Directional Controls

OPERATION MANUAL NTF-15

Hot Water Stationary Unit

OPERATING MANUAL DOUBLE ACTING DRILLING INTENSIFIER HYDRAULIC TYPE

Pilot Operated Check Valves Catalog Quick Reference

Copyright, 2005 GPM Hydraulic Consulting, Inc.

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

Safety and operating instructions

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Accessories. Valves. Adjustable Pressure Relief Valves

MUD 1. Vent check valves. Instruction and maintenance manual.

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

PVQ 13 A2 R SE 1 S 20 C-11 D

Low torque Metal seal type Rotary joint

Pressure Relief Valve DHV 718

Orbital Motors Type OMP X and OMR X

PRESSURE COMPENSATORS TECNORD

Transcription:

1 HDF 200/250-280 HIGH PRESSURE DRILLING FLUID PUMP Dynaset HDF pump gives great water power with small amount of water in relation to its size. As self-priming it is productive in hard environment. Small size, lightweight, durable construction it is especially suitable for drilling application that containing wearing particles. Piston to piston action without rotating parts make hydraulic high pressure drilling fluid pump cost effective. HYDRAULIC FLOW l/min (gal min) max. 280(74) HYDRAULIC PRESSURE bar (psi) max. 220 (3200) WATER DISCHARGE l/min (gal min) max. 250 (66) WATER PRESSURE bar (psi) max. 200 (2900) WEIGHT kg (lb) 170 (375) OPERATING INSTRUCTIONS

2 SAFETY PRECATIONS Operating with DYNASET HDF high-pressure pump user has to conform to all safety regulations concerning pressurized equipment. Hydraulic circuit has a high-pressure over 300 bar. EQUIPMENT TECHNICAL CONDITION HAS TO PAY SPECIAL ATTENTION. In order to avoid accidents all operators and maintenance personnel must act in compliance with the laws, regulations and recommendations the high pressure hydraulics, electricity and work safety issued by local authorities. EXTERME CLEANLINESS MUST BE MAINTAINED WHEN CARRYING OUT ANY DISSASSEMBLING OR REPAIR OF HDF-UNIT AND HYDRAULIC SYSTEM. THIS IS CRUCIAL TO ENSURE SAFE, RELIABLE AND LONG-LIFE OPERATION OF YOUR EQUIPMENT. The pressure in hydraulic fluid circuit is considerably high and hydraulic system has to maintain regularly. Especially couplings, valves and hoses have to be tight and clean as well as kept under constant observation. Check and fix possible leakages of pressure and hot blowouts immediately avoiding user and bystander injuries. In order to exclude possible accidents, it is not allowed to clean or inspect HDF unit when hydraulic fluid circuit is pressurized. Prior to any cleaning, inspection and service hydraulic system of your carrier machine must be stopped and all hydraulic fluid circuits depressurized. Wear appropriate clothing and safety equipment such as goggles, ear and eye protection, safety shoes at all times when operating by the HDF pump. Beware of machinery parts are warm by hot hydraulic oil. Operators and maintenance personnel must always comply with local safety regulations and precautions in order to close out the possibility of damages and accidents. All installation and service hydraulic and electric equipment must be performing experienced personnel only. Preventing freezing nozzles, water circuit and pipeline. Draining and air flushing have to perform before ambient temperature reaches 0 C (32 F) or lower. WARNING STICKERS Dynaset dispatch department includes one (1) warning sticker bag per one (1) main product. Product recipient is obligated to fix determinate warning sticker to Dynaset product. Attach sticker to visible and appropriate place or close to Dynaset product where it s easily seen. Before attaching sticker, clean surface with solvent detergent. READ OPERATING INSTRUCTIONS. BEWARE OF HIGH PRESSURE KEEP FROM FREEZING. USE EAR PROTECTOR AND SPLATTERS. GLOGGLES.

3 DRILLING FLUID PUMP HDF 200/250-280 OUTLINE DIMENSIONS CMP P T WP 340 (1 1 4/10 ) S 745mm (2 5 1/3 ) 15 (6/10 ) 270 (10 6/10 ) 194 (7 6/10 ) 63 (2 5/10 ) 205 (8 ) 120 (4 7/10 ) 248 (9 8/10 ) 370 (1 2 6/10 ) 630 (2 8/10 ) 70 (2 8/10 ) 8 pcs. Ø 16 (6/10 ) FLUID CONNECTIONS HYDRAULIC PORTS PUMPING FLUID PORTS pressure return pressure intake P T CMP WP S * WMP SAE 6000 SAE 6000 BSP SAE 6000 SAE 3000 BSP 1 1/4 1 1/4 1/8 1 2 1/4 * Note: Suction hose > 3

4 GENERAL DYNASET HIGH PRESSURE PUMP HDF 200/250-280 -pump is compact and integrated all-in-one units, designed for both mobile and workshop installation. HDF-pumps perfectly work installed on excavators, mining machines, tractors, trucks and vans. In industrial use, HDF-pump is accompanied with hydraulic power back. DYNASET HDF-pump can be positioned deliberately, keeping in view following preconditions: 1. Easy service access to the unit should be ensured. INSTALLATION 2. Pump should be mounted on sufficiently horizontal surface to enable proper working of leakage detecting bores, which are found above and below seal disc the surface, see blue arrows. We recommended to using eight (8) bolts to secure reliable fastening. Leakage detecting bores are made to the zones, which separate oil and water chambers from each other. If the draining from leakage detectors exceeds rate of 10 drops per minute, pump sealing s should be replaced. The drain fluid can be water, hydraulic oil or their solution. LEAKAGE DETECTING BORES Lower leakage detecting bores Bottom view. Inlet manifold removed INTEGRATION INTO A HYDRAULIC CIRCUIT HDF-pump is to be connected to hydraulic system of carrier machine, as well as to pumping fluid circuit. HDF can be installed with no particular efforts to system based on either constant or variable displacement hydraulic pump, as well as to closed hydraulic systems. 1. HYDRAULIC SYSTEM WITH CONSTANT DISPLACEMENT PUMP: The required oil flow is set by correct dimensioning of the hydraulic pump and keeping the demanded rotation speed or, alternatively, with pressure compensated 3-way valve. 2. HYDRAULIC SYSTEM WITH VARIABLE DISPLACEMENT PUMP: A. In system with OPEN CENTRE the required oil flow is set by DYNASET PRESSURE COMPENSATED PRIORITY VALVE PV-SAE. B. In system with CLOSED CENTRE (load sensing system) the required oil flow is set by DYNASET LS-VALVE kit, which comprises solenoid valve, pressure compensated oil flow limiter and pressure relief valve.

5 INSTALLATION ATTENTION! Check the ports of your HDF-pump and connect it to hydraulic and pumping fluid circuits according to their markings! 1. If the hydraulic pressure line will be connected by accident to the return port and return line correspondingly to the pressure port, it will not cause any harm to HDF-pump, however pump will not operate. 2. Output power of HDF-pump depends on the pressure difference between pressure and return lines. The more is the pressure in return line, the less is concerned pressure difference and output power of the pump. The fact should be taken into account when certain number of machines are intended to be joined-up in series. 3. Since the piston assembly reverses extremely rapidly (refer to the TECHNICAL SPECIFICATIONS), certain oscillation can be imposed to the return line because of pressure pulsation. In order to reduce both pressure pulsation and return line oscillation, the flexible hose with textile fabric cord is recommended to be used in return line to protect from damage low pressure units, such as oil cooler. 4. Prior to connecting HDF-pump to hydraulic circuit, compatibility of used equipment should be ensured. Hydraulic pressure and flow rate produced by hydraulic circuit should meet values demanded by your HDF-pump. Refer to the technical specifications. To ensure secure installation use in hydraulic ports P and T SAE 6000 1 1/4 flanges. Use in water intake S SAE 3000 2 flange. Recommended bolt torques on assembly. - Water head left six (6) bolts M16 300 Nm (221 ft-lb) - Water head right five (5) bolts M16 300 Nm (221 ft-lb), front middle near tank line 1 bolt M16 150 Nm (111 ft-lb) red arrow, see next page). - Seal flange 2 psc. six (6) bolts M16 300 Nm (221 ft-lb). CONNECTIONS ADJUSTING FLOW RATE AND PRESSURE OF PUMPING FLUID 1. Pressure and flow in pumping fluid circuit are adjusted by adjusting corresponding parameters in hydraulic circuit. 2. In circuits based on constant displacement pump closing the water pressure line opens the pressure relief valve in hydraulic system. PAY ATTENTION THAT HYDRAULIC FLUID CIRCULATION THROUGH PRESSURE RELIEF VALVE CAUSES HEATING OF HYDRAULIC SYSTEM! 3. In circuits based on variable displacement hydraulic pump closing the water pressure line adjusts pump s swash plate at 0 angle when hydraulic pump produces flow only for self-lubrication and self-flushing. Pressure control must be fast enough to protect HDF-pump from pressure peaks or the hydraulic system must be provided with pressure peak limiter. PUMP START-UP HDF-pump starts immediately after the hydraulic flow has been put on either with control valve (manual or solenoid) and/or by pulling the trigger of spray gun. Immediately after opening the water pressure line, air is being vented out from the pumping fluid circuit and high-pressure washing is about to begin! DO NOT TRY WITH HAND THE WATER OR AIR COMING OUT FROM HIGH PRESSURE NOZZLE! The nozzle, attached to a pressure tool, determines the flow rate and pressure of water when operating parameters of hydraulic circuit meet HDF-pump s requirements. In other words, even your HDF-pump fits perfectly to hydraulic system and does well with the job, dimensioning of the pressure tool should never be underestimated as a very important step for ensuring the optimal water jet or hydro-demolition power in each application.

6 Different water based solutions and special liquids can be used as pumping fluid with HDF-pumps. The only requirement is that the pump MUST be thoroughly cleaned and flushed with sweet water after the job to prevent pump and its sealing from oxidation and water valves from jamming. The procedure should be made even if such a harmless liquid as seawater has been used. ATTENTION! HDF-pump can be run dry unlimited time without any harm, because self-lubricating sealing and circulating hydraulic oil prevent the pump from overheating. PUMP ASSEMBLY AND BOLT TORQUES LEFT WATER HEAD AND INLET MANIFOLD BOLT TORQUES Right water head 1 piece 150 Nm (111 ft-lb) Left water head 5 pcs. 300 Nm (221 ft-lb) 6 pcs. 300 Nm (221 ft-lb) RIGHT WATER HEAD BOLT TORQUES 150 Nm (111 ft-lb) 5 pcs. 300 Nm (221 ft-lb) LEFT + RIGHT SEALING FLANGE BOLT TORQUES 2 x 6 pcs. 300 Nm

240 kg (530 lb) 7 MAINTENANCE Due to small number of moving parts, in normal operating conditions HDF-pump does not require any other service, except replacement of sealings or occasionally of water valves, which depends on content of abrasives in pumping fluid, as well as on cleanliness of hydraulic oil. Check constantly whether the fluid dropping from pump s leakage detectors is growing and replace sealing in proper time to exclude intermixing of hydraulic oil and pumping fluid. The pressure in hydraulic fluid circuit is considerably high and hydraulic system has to maintain regularly. Especially couplings, valves and hoses have to be tight and clean as well as kept under constant observation. Check and fix possible leakages of pressure and hot blowouts immediately avoiding user and bystander injuries. Prior to any cleaning, inspection and service hydraulic system of your carrier machine must be stopped and all hydraulic fluid circuits depressurized. To enable the easy surveillance, pump should be kept clean. WHEN CARRYING OUT ANY DISASSEMBLING OR REPAIR OF HDF-PUMP, ABSOLUTE CLEANLINESS MUST BE MAINTANED TO ENSURE RELIABLE AND TROUBLE-FREE OPERATION OF YOUR EQUIPMENT. LIFTING THE PUMP Lift HDF 200/250-280 only from eye bolts. Working load limited at 45º fastening, max. total load 240 kg (530 lb). Rope 45º Eye bolt

8 PRODUCT DISPOSAL Conform to waste legislation, regulations and recommendations in waste disposal and waste recycling issued by local authorities. 1. Precondition: Product is permanently useless or beyond repair. Before transportation get off all used agent (oil, cooling liquid) and dirty filters. Items requiring special handling can normally be done by authorized waste management facility, if not: Separating the base materials, iron, copper, steel, electronics, removing paint, polyester resin, and insulation tape and/or plastics residues from all components. This waste material can now be recycled. 2. Deliver the recycling and waste material to waste management facility. Note! Customer can send the DYNASET equipment for reuse or recycling to the Dynaset company or to other location determinate by Dynaset representative. Customer pays shipping cost. Equipment must be adequately packed for shipment. Shipment documents must contain purchaser s name, contact information, equipment type and serial number.

9 TECHNICAL SPECIFICATIONS PARAMETERS HDF 200/250-280 WATER POWER WATER FLOW max l/min (gal/min) 250 (66) WATER PRESSURE max bar (psi) 200 (2900) WATER TEMPERATURE max ºC (ºF) 70 ºC (158) PUMPING POWER max kw (hp) 85 (114) SUCTION HEAD max m 1 WATER FEED PRESSURE min-max bar (psi) -0,1...10 (1.450...145.03 PRESSURE RATIO water/hydraulic 1,06 SPEED RATIO 1/min 180 WATER PISTONS outer diameter mm ( ) D 85 (0.275) WATER CONNECTIONS PRESSURE LINE WP SAE 6000 1 SUCTION / FEED LINE S SAE 3000 2 PRESSURE HOSE recommendation 1 SUCTION HOSE recommendation > 3 WATER FILTER min. μm (mesh) 80 (188) HYDRAULIC CONNECTIONS PRESSURE LINE P SAE 6000 1 1/4 RETURN LINE T SAE 6000 1 1/4 SERVICE LINE pressure gauge CMP BSP 1/8 HYDRAULIC FLUID REQUIREMENTS VISCOSITY cst 10-200 / optimal 25-35 TEMPERATURE ºC (ºF) max. 70 (158) FILTER RATIO recommendation um min. 25 COOLING CAPACITY recommendation kw (hp) 20 (27) HYDRAULIC POWER REQUIREMENTS HYDRAULIC FLUID FLOW max. l/min (gal/min) 280 (74) OPERATING PRESSURE Δp bar (psi) 210 (3046) MAXIMUM PRESSURE bar (psi) 220 (3191) IDLE RUN PRESSURE bar (psi) 10 (145) RETURN LINE PRESSURE max bar (psi) 100 (1450) WEIGHT kg (lb) 170 (375) PRESSURE GAUGE OPTIONAL WATER PRESSURE UNLOADER NOT AVAILABLE LS-VALVE LS OPTIONAL