Installation and Operation Manual

Similar documents
BAPI Pressure Line of Products - FAQs

Instruction Manual Differential Pressure Transmitter

SPD310/SPD360 Air Differential

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Transmitters 36 F-27839

SITRANS P measuring instruments for pressure

IP65 Air Differential Pressure Switch

Precision pressure sensor Basic version Model CPT6020

High-performance submersible pressure transmitter For level measurement Model LH-10

Relative and differential pressure module type 698

AMS 2710 PCB pressure sensor module with V output

Proportional pressure regulators VPPE

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Electro Controls. Pressure WattsIndustries.co.uk

AMS 6916 Board mount pressure sensor with ratiometric analog output

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Design Features. General Description

MANUAL KPS Pressure Control Valve

Sensoric 4-20 ma Transmitter Board Operation Manual

The Ins and Outs of I/P Transducers

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Variable Area Flow Meters

BUBBLER CONTROL SYSTEM

Air Differentail Pressure Switch

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Instruction Manual EMA 84 Digital Pressure Gauge

Solenoid valves VZWF, force pilot operated

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

Pressure Measurement Single-range transmitters for general applications

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

Technical Manual. Liquid Level Transmitter CT801-LB/S

SX150A. Features. Typical Applications. Description

C-Flow Coriolis Mass Flow Meters

Compact pressure switches for gas and air

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

BUBBLER CONTROL SYSTEM

ACV-10 Automatic Control Valve

Ambient Capacitance Gauge

Instruction and Maintenance Manual

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Instruction Manual Differential Pressure Transmitter

INSTALLATION & MAINTENANCE INSTRUCTIONS

[Instruments for vacuum measurement, checking and adjustment] 3

AMS 6915 Board mount pressure sensor with digital output (I²C)

2/ Port G1/4

Pressure transmitter PASCAL Ci4

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Digital electro-pneumatic regulators Series ER100

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Digital deadweight tester Model CPD8500

P-5215 Differential Pressure Transmitter

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Mass Flow Controller (MFC) for Gases

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

Instruction Manual Contact Pressure Vacuum Gauge

Types and approvals. Page 1/6. Data Sheet

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Product Catalogue MINICOMB. Switches for Pressure and Vacuum

Instruction and Maintenance Manual

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

How to specify a product. Process Sensors and Mechanical Instruments

Cover Page for Lab Report Group Portion. Pump Performance

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Torque Tube TB300 Digital Transmitters

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Gas Pressure Switch for DMV safety shutoff valves

Pressure Measurement Single-range transmitters for general applications

ATM.ECO - Analog Pressure Transmitter

STARLOG. Capacitive Water Depth Probe

HTD series digital differential pressure sensors

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Operating instructions Pressure sensor. PN422x / / 2013

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Mass Flow Controller (MFC) for Gases

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Proportional pressure regulators VPPM

Capacitance Diaphragm Gauge

Electro Controls. Level WattsIndustries.co.uk

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Pressure independent control valve (PICV) FLOWMATIC

Research Grade Blood Pressure Transducer User's Manual

Automatic Isokinetic Sampler. ST5 Evo

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Gas Pressure Switch for DMV safety shutoff valves

Installation, operating and maintenance Instructions for Seemag bypass level indicator

ATM - Analog Pressure Transmitter

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

STUDY OF I/P AND P/I CONVERTER

Digital dead-weight tester Model CPD8500

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Measuring range Δp (span = 100%) Pa

Transcription:

Manual Static pressure transducer with controller Differential static pressure transducer with analog output and optional PI control mode Large diaphragm element with differential transformer Transducer choice of five pressure ranges Simple setup and operation completely without external communication devices Clear text LCD-display, two push button switches, and one magnetically activated switch. Selectable s: Differential pressure or volume flow Metric or imperial units selectable Control mode with PI algorithm and measurement mode selectable Two adjustable set points Analog output 0...10 V dc Upper output voltage limit is adjustable Supply 10...30 V dc or 24 V ac (+/-15%) Compact plastic housing according to IP 54 and flammability rating UL 94 HB RoHS Directive 2011/65/EU compliant ebm-papst Inc. part number HX0C-000-00-001 HX0C-000-00-002 HX0C-000-00-003 HX0C-000-00-004 HX0C-000-00-005 HX0C-000-00-006 Dimensions (mm) p/n 610-00-0066 rev2 revision 2015-07-23

Safety instructions Attention! Study these instructions carefully, before you connect this item. Only qualified technicians familiar with installation, construction and operation of the equipment shall work around this item. Applications This static pressure transducer with controller measures low pressure differentials of dry air and inert gases and it provides optional control. Its output signal depends on the operating mode: For pressure measuring mode the device puts out 0-10 Vdc proportional to the applied pressure differential. For air volume measuring mode in combination with an instrumented fan inlet ring, the controller internally performs a square root calculation. Its 0-10 Vdc output is proportional to the calculated air volume flow according to In closed-loop control mode the device puts out a PI control signal for a self-regulating air system. This static pressure transducer with controller is primarily intended for air conditioning systems, room pressure control, and filter control with continuously variable speed fans. Description A differential pressure applied to the pressure ports (+) and ( ) displaces a silicone diaphragm against a measuring spring. A differential transformer and suitable electronics convert this displacement into a continuously variable output voltage signal. The large diaphragm mechanism keeps measurement value fluctuations to a minimum. The static pressure transducer with controller combines several functions: 1. Measuring mode options: a. The LCD display indicates the differential pressure and physical unit (Pa or in. wg), and a proportional 0 10 V signal is available at terminal #3. b. The LCD display indicates the calculated volume flow and physical unit (m 3 /h or cfm) and a proportional 0 10 V signal is available at terminal #3. 2. Control mode options: The integrated controller accepts two adjustable set points that can be switched with a potential free contact connected to terminals #5+#6. The function of the controller is to reach and maintain the activated set point. The controller continuously compares the measured differential pressure against the activated set point, performs a PI control calculation, and accordingly puts out a 0 10Vdc control signal. This signal is directly suitable to control a fan motor. The upper limit of the PI control signal output is adjustable. The adjustable proportional (P) gain and integral (I) gain permit tuning of the control loop. 2

Electrical connections Six electrical screw terminals and two push button switches are located behind the front cover. Offset: Gravity affects the diaphragm and consequently the pressure measurement value. A brief touch of the housing with a magnet-tipped screw driver at the marked location permits activation of a Reed switch in the control electronics from the outside. With the transducer in its final mounting orientation but no pressure probes connected this process adjusts the gravity effect to zero. The controller will display for a short time that the offset has been zeroed and saved. 3

Mounting This static pressure transducer with controller is designed for wall mounting vertically. Its mounting orientation affects the measurements. The pressure ports accommodate plastic tubing with 5 mm and 6 mm inner diameter. Operation Start up: Mount the device vertically. Establish all electrical connections in accordance with this manual. Use a regulated supply voltage. Zero the offset. Connect pressure tubing. Factory default settings: Operating mode: measuring mode Zero point: adjusted to measuring range End point: adjusted to measuring range Set point 1: about 75% of the measuring range Set point 2: about 25% of the measuring range Max. voltage: 10.0 Vdc output P gain: 50 I gain: 3.15 K factor: 70 Control mode positive / heating T1 push button switch 1 T2 push button switch 2 4

Commissioning: Available units Operation mode selections Parameter selections K factor Accept and display metric or IP units. Control mode or measuring mode Either differential pressure (Pa or in. wg) or volume flow (m 3 /h or cfm) calculated volume flow in m 3 /h or cfm adjustable constant according to venturi manufacturer data sheet measured nozzle pressure Set point selections SP1 and SP2 (e.g. high/low, summer/winter, day/night) Set point range Adjustable pressure from 0% to 100% of the sensor range Adjustable volume flow from 5% to100% of corresponding range Output voltage limit Adjustable maximum from 0 to 10 Vdc P gain range 0 1000 I gain range 0 100 Control mode selections Positive/heating Control deviation equals set point minus actual value. The output increases when the set point is greater than the actual value. or Negative/cooling Control deviation equals actual value minus set point. The output increases when the actual value is greater than the set point. 5

Technical data ebm-papst Inc. part number Installation and Operation static pressure span (sensor range) in. wg static pressure span (sensor range) Pascal maximum k factor HX0C-000-00-002 0-0.2 0-50 1000 HX0C-000-00-001 0-2.0 0-500 1000 HX0C-000-00-003 0-4.0 0-1000 1000 HX0C-000-00-005 0-8.0 0-2000 700 HX0C-000-00-004 0-16 0-4000 500 Media Air and non-aggressive gases Measuring principle Silicon diaphragm with spring and differential transformer Overpressure protection 80 in. wg (0.2 bar) Static pressure maximum 80 in. wg (0.2 bar) ure ports Suitable for 5 6 mm tubes Materials Polyamide case, ABS cover UL 94 HB Supply voltage 10...30 Vdc or 24 Vac ± 15 %) Reverse polarity protected Current consumption ~10 ma @ 10Vdc; ~12 ma @ 24 Vdc Output 0...10 Vdc Display LCD, 2x16 characters Modes Measuring mode or Control PI algorithm Set points 2 set points, push button adjusted Set point selection Dry contact Protection class IP 54 according EN 60529 Ambient temperature 14 F 122 F (-10...+50 C) Storage temperature -13 F 140 F (-25...+60 C) Weight Approx. 0.5 LBS (250 g) Mounting orientation Vertical, position dependence by turning of 90 : approx. 25 Pa Interference emission CE compliant per EN 50081-2, EN 50082-2 Influences limits Zero error ± 0.75 % Sum of linearity and hysteresis ± 0.5 %... ± 1 % (depends on measuring range) Temperature drift, zero point ± 0.17 % / 10 F (± 0,3 % / 10 K) Temperature drift, span ± 0.11 % / 10 F (± 0,2 % / 10 K) 6

P = 150 Pa (1) about 2 seconds to start menu menu unit metric unit imperial operating mode measuring mode operating mode diff. pressure volume flow diff. pressure volume flow fan k-factor k = 70 setpoint 1 50 Pa fan k-factor k = 70 setpoint 2 250 Pa output voltage U= 10,0 V P - 50 I - 3,15 positive/heating negative/cooling back and confirm to leave menu P = 150 Pa (1) for menu menu