Atlas Copco Compressed Air Piping System

Similar documents
SIMPLAIR PIPING TOOL. JXT Company

Rapidmain Installation Guide

COMPRESSED AIR DISTRIBUTION SYSTEMS

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Type 4708 Supply Pressure Regulator

VERTICAL BLADDER TANK

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Type 4708 Supply Pressure Regulator

TECHNICAL DATA. Q = C v P S

Booster Regulator/Air Tank

Piloted Non-Return Valves

3/8" Dr. Air Butterfly Impact Wrench

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Gas Welding Hoses and connections, the weak link

HORIZONTAL BLADDER TANK

TECHNICAL HANDBOOK nvent CADDY Speed Link Manual. SLS Locking Device

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Anti-flood device Model B-1

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

FIREFIGHTING EQUIPMENT

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

Aquor House Hydrant V2

// ADapters GUIDelines

Encore PE 50-lb Feed Hopper

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Engineering Data Sheet

Direct Operated Precision Regulator Modular Style. Standard Specifications

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

TECHNICAL DATA CAUTION

VACUUM REGULATORS CONTENTS

patented standards SAFETY QUICK COUPLINGS EXPERTISE AT THE SERVICE OF SAFETY AND PERFORMANCE a n d ot h e r p e n di n g

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Type 4708 Supply Pressure Regulator

Pilot Check Valve: Metal Body Type

Series MG Mixing Tubes

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

TECHNICAL DATA. Q= Cv S

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

TRAVSMART permanent single-cable horizontal lifeline system

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Barcol-Air BRM Radiant Module

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Pressure Measurement Single-range transmitters for general applications

Vertical Bladder Tanks

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

NHR-X-X Encore Feed Hoppers

Manual Actuated Boiler Blowdown Valves

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

CAST IRON SAFETY VALVE TYPE 6301

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

Materials : Carbon steel ASTM A216 WCB

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

TECHNICAL HANDBOOK. nvent CADDY Speed Link Manual Overview of Wire Rope Hanging

2-port seat valves PN25 with externally threaded connections

INDUSTRIAL HOSE REEL suitable also for out-door workplaces. Made in Italy

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Horizontal Bladder Tanks

Pneumatic spool valve islands

Model MTB-ASME Vertical Bladder Tanks

[Graphic Division] 10

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

NHR Powder Feed Hopper

100C Air Compressor Kit

Pressure Dump Valve Service Kit for Series 3000 Units

Model MTB-ASME Vertical Bladder Tanks

IMPORTANT SAFETY INSTRUCTIONS

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Atlas Copco Tools & Assembly Systems. Air Line Accessories Optimizers- FRL

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Tank Blanketing Pressure Regulators RHPS Series

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

Workshop Compressors CLASSIC Series

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

J138RSH and J150RSH 3/8" J138RSH 1/2" J150RSH. 3/8" Drive Sealed Head Ratchet 1/2" Drive Sealed Head Ratchet. Operation and Maintenance Manual WARNING

Coiling Tube with Twist-Proof Fitting

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

200 PSI COMPRESSORS - MODEL NUMBERS

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:

SEALED CONNECTORS FOR THE LIMIT SWITCHES

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

INSTRUCTION MANUAL. January 23, 2003, Revision 0

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

Installation and commissioning instructions 255 series and 256 series

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Pneumatic valve islands

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Pressure Dump Valve Service Kit for Series 2300 Units

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Transcription:

Atlas Copco Compressed Air Piping System Catalog Ordering and Installation Guide

QUALITY AIR WHERE YOU NEED IT SYSTEM SAVINGS HIGH COMPATIBILITY QUICK TO INSTALL 1

A COMPLETE SOLUTION The AIRnet compressed air piping system is a complete solution from source to production thanks to its high quality aluminium pipes, its range of aluminium and polymer fittings from Ø20-80 mm (¾ - 3 ) and variety of specialized tools, brackets and bushing. HIGH MATERIAL RESISTANCE The AIRnet piping system is resistant to corrosion, mechanical shocks, thermal variations and outdoor weather conditions. THE FLEXIBLE FIT AIRnet s thread assembly, system cleanness and easy disassembly mean full reusability, fast extension possibilities, and full control over the network. MINIMUM LEAKAGE O-ring ensures an airtight fit. Resistant to vibration. No risk of corrosion. Easy system maintenance. No energy waste. AIRnet PLANNER VIRTUAL INSTALLATION AIRnet Planner creates a 3D installation diagram using real-size equipment and real-life environments. It also calculates the pressure drop and estimates the time needed for assembly. Other handy features include a bill of material and a detailed quotation file. Keep your eye out for this icon and learn some interesting facts! 2

GENERAL INFORMATION AIRnet 10 year guarantee In line with the high quality performance of our AIRnet product range, we offer our customer a 10 year guarantee on AIRnet fittings and aluminium pipes against any damages resulting from material defect. WARRANTY COVERAGE TERMS Use only genuine parts. Perform installation according to our instructions and guidelines. Never use the components below or in excess of its limit ratings. Protect your installation against shocks or vibrations, corrosive environments. Damaged parts and/or site conditions must be submitted for inspection, prior to the settlement of any claim. AIRnet warranty is restricted to component replacement only. Claims should be addressed to any Atlas Copco Customer Center or Authorized Atlas Copco distribution network according to the standard procedure. This 10 year guarantee is limited to providing you with a new AIRnet fitting or pipe and is subject to our determination that the fitting or pipe failed exclusively due to a defect in the material at the time of manufacture. 3

TABLE OF CONTENTS TABLE OF CONTENTS A. General Information... P 1-8 B. Product Catalog... P 9-32 To inform you on all items needed to install a complete compressed air piping system, the AIRnet product catalog is divided into 6 chapters. 1. Piping... P 9-11 2. Fittings...P 12-20 3. Accessories...P 21-24 4. Installation Material... P 25-27 5. Gripple... P 28-33 6. Tools...P 34 C. Installation Guide...P 35-46 4

GENERAL INFORMATION General specifications COMPLIANCY EN 13480 / Directive 97/23/EC and ASME B31.1 Complies with Common Pressure related approvals PED CE ASME MOL UDT SQL CRN DIR MOM-ASME Ø20-25 - 40-50 mm Ø63-80 mm Ø20-25 - 40-50 - 63-80 mm 3/4-1 - 1 1/2-2 21/2-3 3/4-1 - 11/2-2 - 21/2-3 PERFORMANCE CRITERIA Compatible with compressed air, vacuum and inert gasses such as Nitrogen. Maximum working pressure PN13 for temperatures between -20 C (-4 F) and +70 C (158 F). Vacuum level 0.13 bar (1.88 psi) absolute pressure. Operating temperature limits: -20 C (-4 F) / +70 C (158 F). Lowest allowable pressure dewpoint: -70 C (-94 F). Resistant to the effect of compressor oils (mineral oil / PAO based / Esther based oils). The AIRnet range is fire-resistant (according to UL94 HB). AIRnet pipes are resistant to direct UV radiation and fittings are resistant to indirect UV radiation. Corrosion-free. Leakage-free. Silicone-free. Oil-free applications. Material PA6 with 30% fiberglass injection. Grip ring: stainless steel. Seal NBR 70SH rubber. Body color RAL 7011. Nut color RAL 9011. AIRnet logotype embossed. Part number. Nominal DN diameter. Date of manufacture (year / month) in casting data clock. Aluminium alloy EN-AB47100-EX.5079. Grip ring: stainless steel. Seal NBR 70SH rubber. Body color RAL 7011. Nut color RAL 9011. AIRnet logotype embossed. Part number. Nominal DN diameter. Date of manufacture (year / month) in casting data clock. Extruded aluminium ANSI B241 UNS alloy A96063 T5. Color RAL 5012 for air. Color RAL 6018 for inert gasses, e.g. Nitrogen. AIRnet logotype marking. Part number. Maximum design pressure indication. Nominal outside and inside diameter marked, e.g. Ø50 x 46 mm (2 x 1¾ ). Date of manufacture (year / week). TESTING PERFORMANCES We have applied the most severe testing conditions to our product to simulate the highest industrial standards. High pressure resistance during one hour. Burst pressure to extreme high pressure. Leakage-free test based on vibration cycle at different frequencies. Leakage-free test based on pressure pulsation test. 5

GENERAL INFORMATION PRODUCT IDENTIFICATION 2810 A B C D E A: AIRnet range family index B: Inlet pipe diameter (OD) C: Thread OD or reduced AIRnet fitting diameter D: Fitting code E: Lot size Example: 2810 4221 03 2810: AIRnet 4: Pipe diameter Ø40 mm (1½ ) 2: Outlet AIRnet fitting diameter Ø25 mm (1 ) 21: Reducing socket 03: Lot size: pack of 3 pieces (The lot size indicates the minimum quantity available for ordering.) Ø CODE Ø (inch/mm) 0 12.5 / ½ 1 20 / ¾ 2 25 / 1 4 40 / 1½ 5 50 / 2 6 63 / 2½ 7 80 / 3 FITTING CODE FITTING PAGE NUMBER 00 Air pipe 6m (20 ft) 9 63 Air pipe 3m (10 ft) 9 61 N2 pipe 6m (20 ft) 10 01 S-bend 10 02 Equal socket 12 03 90 elbow 12 04 45 elbow 12 05 Equal tee 12 06 End cap 21 07 Reducing tee 13 08 / 09 Threaded reducing tee 17 10 Quick drop 15 11 / 12 Threaded quick drop 16 13 / 14 Adaptor union 19 15 / 16 Nipple socket male polymer 18 17 / 18 Nipple socket male alu 19 19 / 20 Nipple socket female alu 18 21 Reducing socket 13 22 / 27 Pipe clip & spacer 27 / 28 23 / 24 Wall mounted bracket 20 25 / 26 Threaded wall mounted nipple 20 51 Valve 13 52 / 53 Threaded valve 21 30-39 / 50 Brackets 27 / 28 28 / 29 / 40-45 Tools 29 60 Inner parts 22 65 / 66 O-ring 22 54 / 00 / 01 Flanges 21 All fittings are available in NPT and BSP threaded standards. 6

GENERAL INFORMATION AIRnet fitting design 1 2 3 4 5 1 2 3 4 5 STRONG-GRIP INTERNAL DESIGN New design increasing grip, strength and safety (with stainless steel clinch ring) SPECIFIC NUT DESIGN Notches enable you to tightly secure the AIRnet spanner, without damaging the nut itself. SPECIFIC BODY DESIGN Very large inner body diameter eliminates the flow resistance and pressure drop. Flow guide reduces the pressure drop. PARTS IDENTITY Part number and diameter are embossed. AIRnet uses a single assembly method for all diameters, ensuring the shortest possible assembly time, from 1.5 minutes for the smallest to 4 minutes for the largest diameters. UNIQUE ASSEMBLY SYSTEM STEP STEP STEP Push the pipe into the fitting. Tighten the fitting by hand. Secure the connection with a spanner (only necessary for >Ø40 mm (>1½ ) fittings). 7

GENERAL INFORMATION AIRnet vs. traditional galvanized pipes AIRnet PIPES GALVANIZED PIPES Smooth surface. Rough surface. Low friction factor. Friction factor is almost double of an aluminium pipe. Low initial pressure drop. (E.g. In a system with an air demand of 110 l/s, designed as a 400 m long ring of Ø50 mm (2 ) pipes with P = 7 bar, the pressure drop (ΔP) equals 0.2 bar.) High initial pressure drop. (E.g. In a system with an air demand of 110 l/s, designed as a 400 m long ring of Ø50 mm (2 ) pipes with P = 7 bar, the pressure drop (ΔP) equals 0.37 bar.) Aluminium and polymer fittings are corrosion-free. Corrosion protection depends on galvanization quality. No risk of corrosion when cutting the aluminium. Very low risk of leakage, which is not related to corrosion. When cutting the pipe, the galvanization is removed. The connection poses a high risk of corrosion at low level points where water can stagnate, resulting in a high risk of leakage. Lightweight pipes: a standard Ø50 mm (2 ) diameter pipe weighs less than 5 kg (11 lbs). Heavy pipes: a standard Ø50 mm (2 ) pipe weighs more than 25 kg (55 lbs). Short manual cutting time. Very long manual cutting time, electrical cutter may generate some metallic dust. Fast deburring of the pipe. Pipes can be simply pushed into the fitting. Threading the pipe requires a certain level of experience to avoid future leakage. The fittings can be tightened by hand and secured with a spanner. The galvanized fittings need to be tightened using a spanner. The risk of leakage depends on the quality of the thread. Modifying the network is easy: the fittings and pipes can be simply disassembled and re-used. Modifying the network is often difficult: after disassembly, the pipes have to be cut, changed, threaded and re-assembled. Standard painted blue (compressed air) or green (inert gases) for easy network identification. Pipes need to be painted in the appropriate color, adding to the total cost. 8

PRODUCT CATALOG PIPING PIPING ALUMINIUM PIPES Calibrated pipe / Color RAL 5012 for air pipes / Color RAL 6018 for Nitrogen pipes Qualicoat label / Fire resistant Operating limits: Maximum pressure: 13 bar (188 psi) Vacuum level = 0.13 bar (1.88 psi) Temperature limits: -20 C (-4 F) to +50 C (122 F) ambient temperature -20 C (-4 F) to +70 C (158 F) operating temperature 2810 1000 00 - DN 20 - PN 13 BAR To ensure a leakage-free and safe installation, only Atlas Copco s aluminium pipes have been calibrated, tested and approved for the assembly of AIRnet fittings. In most industrial standards, compressed air networks can be identified by their blue color. To optimize your installation costs, their standard length is 6 m (20 ft), which also is the standard industrial length. Aluminium pipe for air (6 m / 20 ft) 2810 00 OUTSIDE Ø INSIDE Ø LENGTH (m / ft) WEIGHT (kg / lbs) 2810 1000 00 20 / ¾ 17.4 / 0.69 6 / 20 1.2 / 2.6 10 2810 2000 00 25 / 1 22.2 / 0.87 6 / 20 1.9 / 4.2 10 2810 4000 00 40 / 1½ 36.4 / 1.43 6 / 20 3.5 / 7.7 05 2810 5000 00 50 / 2 46.0 / 1.81 6 / 20 4.6 / 10.1 04 2810 6000 00 63 / 2½ 59.0 / 2.32 6 / 20 6.2 / 13.7 03 2810 7000 00 80 / 3 76.0 / 2.99 6 / 20 9.5 / 20.9 02 3 m (10 ft) pipes are especially suitable for a short network extension or for an installation requiring a short length of a certain diameter. The 3 meter packs are available in different quantities. Aluminium pipe for air (3 m / 10 ft) 2810 63 OUTSIDE Ø INSIDE Ø LENGTH (m / ft) WEIGHT (kg / lbs) 2810 1063 00 20 / ¾ 17.4 / 0.69 3 / 10 0.6 / 1.3 10 2810 2063 00 25 / 1 22.2 / 0.87 3 / 10 0.9 / 2.0 10 2810 4063 00 40 / 1½ 36.4 / 1.43 3 / 10 1.7 / 3.7 05 2810 5063 00 50 / 2 46.0 / 1.81 3 / 10 2.3 / 5.1 05 2810 6063 00 63 / 2½ 59.0 / 2.32 3 / 10 3.1 / 6.8 04 2810 7063 00 80 / 3 76.0 / 2.99 3 / 10 4.7 / 10.4 04 9

PIPING PRODUCT CATALOG In most industrial standards, networks for inert gases, such as nitrogen, can be identified by their green color. The green AIRnet pipes can be used to assemble a network after GN compressors. Aluminium pipe for inert gases (6 m / 20 ft) 2810 61 OUTSIDE Ø INSIDE Ø LENGTH (m / ft) WEIGHT (kg / lbs) 2810 1061 00 20 / ¾ 17.4 / 0.69 6 / 20 1.2 / 2.6 05 2810 2061 00 25 / 1 22.2 / 0.87 6 / 20 1.9 / 4.2 05 DOUBLE S-BEND The double S-bend is a 50 cm (19.7 ) long, rigid, pre-curved section of aluminium pipe, often used to fix drop legs closer to the wall when the main ring is installed further away from the wall. Double S-bend 2810 01 LENGTH drop leg Ø 20 mm (¾ ) drop leg Ø 25 mm (1 ) (cm / inch) 2810 1001 00 2810 2001 00 50 / 19.7 05 10

Design of the main ring and distribution lines The main ring is often the main skeleton of a network. This loop is located close to the main point of use, with drop legs connecting the main ring to your point of use, ensuring a minimal pressure drop. Using a main ring, the pressure drop is twice as low as when using a straight distribution line of the same length. In general, the main ring s diameter is based on the capacity of all compressors connected to the network, and should take possible future extensions into account. A distribution line is usually preferred to connect the main ring to a single point of use which is isolated in a remote location. The diameter of the distribution line should be based on the air demand at this specific point of use. Cross ring lines are distribution lines which connect the opposite sections of the main ring to guarantee a minimal pressure drop in other locations than the main point of use. 11

FITTINGS PRODUCT CATALOG FITTINGS EQUAL DIAMETERS Equal socket 2810 02 PART NUMBER Ø DIMENSIONS L W H 2810 1002 00 20 / ¾ 102 / 4 36 / 1.4 36 / 1.4 01 2810 2002 00 25 / 1 125 / 4.9 45 / 1.8 45 / 1.8 01 2810 4002 00 40 / 1½ 199 / 7.8 72 / 2.8 72 / 2.8 01 2810 5002 00 50 / 2 227 / 8.9 89 / 3.5 89 / 3.5 01 2810 6002 00 63 / 2½ 186 / 7.3 89 / 3.5 92 / 3.6 01 2810 7002 00 80 / 3 233 / 9.2 113 / 4.4 116 / 4.6 01 90 elbow 2810 03 PART NUMBER Ø DIMENSIONS L W H 2810 1003 00 20 / ¾ 82 / 3.2 82 / 3.2 36 / 1.4 01 2810 2003 00 25 / 1 100 / 3.9 100 / 3.9 45 / 1.8 01 2810 4003 00 40 / 1½ 160 / 6.3 160 / 6.3 72 / 2.8 01 2810 5003 00 50 / 2 188 / 7.4 188 / 7.4 89 / 3.5 01 2810 6003 00 63 / 2½ 168 / 6.6 96 / 3.8 168 / 6.6 01 2810 7003 00 80 / 3 213.5 / 8.4 113 / 4.4 213.5 / 8.4 01 45 elbow 2810 04 Ø DIMENSIONS L W H 2810 1004 00 20 / ¾ 106 / 4.2 67 / 2.6 36 / 1.4 01 2810 2004 00 25 / 1 128 / 5.0 83 / 3.3 45 / 1.8 01 2810 4004 00 40 / 1½ 205 / 8.1 65 / 2.6 72 / 2.8 01 2810 5004 00 50 / 2 238 / 9.4 154 / 6.1 89 / 3.5 01 Equal tee 2810 05 PART NUMBER Ø DIMENSIONS L W H 2810 1005 00 20 / ¾ 127 / 5 82 / 3.2 36 / 1.4 01 2810 2005 00 25 / 1 155 / 6.1 100 / 3.9 45 / 1.8 01 2810 4005 00 40 / 1½ 249 / 9.8 160 / 6.3 72 / 2.8 01 2810 5005 00 50 / 2 286 / 11.3 188 / 7.4 89 / 3.5 01 2810 6005 00 63 / 2½ 247 / 9.7 138 / 5.4 92 / 3.6 01 2810 7005 00 80 / 3 314 / 12.4 213.5 / 8.4 113 / 4.4 01 12

PRODUCT CATALOG FITTINGS REDUCING DIAMETERS Reducing socket 2810 21 Ø REDUCED Ø DIMENSIONS L W H 2810 2121 00 25 / 1 20 / ¾ 115 / 4.5 45 / 1.8 45 / 1.8 01 2810 4221 00 40 / 1½ 25 / 1 165 / 6.5 72 / 2.8 72 / 2.8 01 2810 5421 00 50 / 2 40 / 1½ 215 / 8.5 89 / 3.5 89 / 3.5 01 Reducing tee 2810 07 Ø REDUCED Ø DIMENSIONS L W H 2810 2107 00 25 / 1 20 / ¾ 155 / 6.1 96 / 3.8 45 / 1.8 01 2810 4207 00 40 / 1½ 25 / 1 249 / 9.8 144 / 5.7 72 / 2.8 01 2810 5407 00 50 / 2 40 / 1½ 286 / 11.3 179 / 7 89 / 3.5 01 BALL VALVES AIRnet is compatible with standard industrial ball valves, using nipple sockets to connect the valves to the system. Please refer to the section Connection equipment on page 18 for more information on the nipple socket range. Ball valve (BSP thread) Ø DIMENSIONS L W H 1619 6153 04 12.5 / ½ 127 / 5.0 33 / 1.3 71 / 2.8 01 1619 6153 05 20 / ¾ 129 / 5.1 40 / 1.6 78 / 3.1 01 1619 6153 06 25 / 1 192 / 7.6 50 / 2.0 102 / 4.0 01 1619 6153 07 32 / 1¼ 200 / 7.9 50 / 2.0 102 / 4.0 01 1619 6153 08 40 / 1½ 204 / 8.0 50 / 2.0 102 / 4.0 01 1619 6153 09 50 / 2 275 / 10.8 87 / 3.4 173 / 6.8 01 0852 0010 08 80 / 3 201 / 7.9 140 / 5.5 205 / 8.1 01 AIRnet valve 2810 51 Ø DIMENSIONS L W H 2810 1051 00 20 / ¾ 140 / 5.5 70 / 2.8 100 / 4.0 01 2810 2351 00 25 / 1 165 / 6.5 75 / 3.0 100 / 4.0 01 2810 4051 00 40 / 1½ 260 / 10.2 105 / 4.1 140 / 5.5 01 2810 5051 00 50 / 2 285 / 11.2 125 / 5.0 150 / 5.9 01 2810 6051 00 63 / 2½ 220 / 8.7 185 / 7.3 310 / 12.2 01 2810 7051 00 80 / 3 265 / 10.4 200 / 7.9 330 / 13.0 01 13

FITTINGS PRODUCT CATALOG VALVES ARE USED FOR VARIOUS PURPOSES: To isolate a main ring, a distribution line or a drop leg. This facilitates possible future modifications of the system. To bypass air treatment equipment in order to perform service without stopping the air production. 14

PRODUCT CATALOG FITTINGS QUICK DROP Quick drops are specifically designed to connect a distribution line or a main ring to a drop leg from the middle of the pipe. This unique fitting design makes it possible to create a new drop leg extension in minimum time. As the connection is made from the side section, the risk of condensate pollutant is eliminated. 1 DRILLING HOLE Positioned at an exact 180 angle from the connecting hole, the drilling hole facilitates the preparation of the pipe. 2 CLAMP FIXTURE Loosen and tighten to adjust your quick drop around the pipe. 4 3 2 5 3 4 5 MARKINGS Indicate the optimum position of the pipe when drilling in order to match the final position. O-RING Ensures a leakage-free assembly. CONNECTED Ø Ranging from Ø25 mm (1 ) to Ø80 mm (3 ). 1 6 OUTLET Ø Available in two diameters: Ø20 mm (¾ ) and Ø25 mm (1 ). 6 7 7 BRASS OUTLET Ø Robust; resistant to several assemblies (for threaded quick drops only). Quick drops are usually standardized to a single diameter all over the plant. The selected diameter should be based on the air demand at the point of use with the highest consumption. The quick drop range is available in two outlet diameters, Ø20 mm (¾ ) and Ø25 mm (1 ), matching standard drop leg sizes. A quick drop can be assembled in less than 5 minutes and does not require any specific tools. Quick drop 2810 10 MAIN Ø DIMENSIONS drop leg Ø 20 mm (¾ ) drop leg Ø 25 mm (1 ) L W H 2810 2110 00 25 / 1 106 / 4.2 59 / 2.3 52 / 2 01 2810 4110 00 2810 4210 00 40 / 1½ 125 / 4.9 70 / 2.8 52 / 2 01 2810 5110 00 2810 5210 00 50 / 2 150 / 5.9 111 / 4.4 63 / 2.5 01 2810 6110 00 2810 6210 00 63 / 2½ 148 / 5.8 110 / 4.3 62 / 2.5 01 2810 7110 00 2810 7210 00 80 / 3 214 / 8.4 165 / 6.5 63 / 2.5 01 15

FITTINGS PRODUCT CATALOG THREADED QUICK DROP Threaded quick drops are designed to divert a distribution line or a main ring from the middle of the pipe. They can be connected to Ø12.5 mm (½ ) or Ø20 mm (¾ ) male inlets and have multiple purposes: Used as drop legs In combination with a rubber hose, the threaded quick drop outlets can be used to create drop legs. Connect point of use equipment A threaded quick drop almost instantly provides an additional point of use from the existing pipe, and can be used to hook up a spray air gun or air gun. Connect instrumentation devices Conveniently add pressure sensors or a pressure gauge to the network. Threaded quick drop (NPT thread) 2810 12 drop leg thread outlet Ø12.5 mm (½ ) drop leg thread outlet Ø20 mm (¾ ) MAIN Ø DIMENSIONS L W H 2810 2012 00 25 / 1 90 / 3.5 69 / 2.7 52 / 2 01 2810 4012 00 2810 4112 00 40 / 1½ 102 / 4 94 / 3.7 52 / 2 01 2810 5012 00 2810 5112 00 50 / 2 127 / 5 111 / 4.4 62 / 2.4 01 2810 6012 00 2810 6112 00 63 / 2½ 128 / 5.0 110 / 4.3 62 / 2.4 01 2810 7012 00 2810 7112 00 80 / 3 195 / 7.7 165 / 6.5 63 / 2.5 01 16

PRODUCT CATALOG FITTINGS THREADED REDUCING TEE Also a threaded reducing tee can be used to divert a distribution line or a main ring from the middle of the pipe in order to bypass an obstacle or avoid a difficult geometry. A threaded reducing tee is often used to connect a rubber hose to the system. Threaded reducing tee (NPT thread) 2810 09 Ø REDUCED THREAD OUTLET Ø DIMENSIONS L W H 2810 1009 00 20 / ¾ 12.5 / ½ 127 / 5 85 / 3.3 85 / 3.3 01 2810 2009 00 25 / 1 12.5 / ½ 155 / 6.1 96.9 / 3.8 97 / 3.8 01 2810 6509 00 63 / 2½ 50 / 2 247 / 9.7 116 / 4.6 92 / 3.6 01 2810 7609 00 80 / 3 63 / 2½ 314 / 12.4 153.5 / 6.0 113 / 4.4 01 2810 7709 00 80 / 3 80 / 3 314 / 12.4 139.5 / 5.5 113 / 4.4 01 NIPPLE SOCKET Nipple sockets are used to connect any sort of equipment to or from the inlet or outlet thread. Nipple sockets are key fittings which guarantee compatibility with any existing network or piece of equipment. A large range of nipple sockets is available to ease the connection to any existing thread. For each diameter, the thread outlet is available in 2 sizes: to connect to the same diameter, to connect to a smaller diameter (one size smaller). This limits the use of additional galvanized bushes and nipples to make both systems compatible. The range of nipple sockets is available in a polymer or aluminium body. For larger diameters, it is recommended to use the aluminium body thread. Polymer nipple socket male (NPT thread) 2810 16 AIRnet Ø MALE OUTLET Ø DIMENSIONS L W H 2810 1016 00 20 / ¾ 12.5 / ½ 69 / 2.7 36 / 1.4 36 / 1.4 01 2810 1116 00 20 / ¾ 20 / ¾ 71 / 2.8 36 / 1.4 36 / 1.4 01 2810 2216 00 25 / 1 25 / 1 85 / 3.3 45 / 1.8 45 / 1.8 01 2810 4416 00 40 / 1½ 40 / 1½ 124 / 4.9 72 / 2.8 72 / 2.8 01 2810 5516 00 50 / 2 50 / 2 144 / 5.7 89 / 3.5 89 / 3.5 01 17

FITTINGS PRODUCT CATALOG Aluminium nipple socket female (NPT thread) 2810 20 AIRnet Ø FEMALE OUTLET Ø DIMENSIONS L W H 2810 1120 00 20 / ¾ 20 / ¾ 71 / 2.8 36 / 1.4 36 / 1.4 01 2810 2220 00 25 / 1 25 / 1 85 / 3.3 45 / 1.8 45 / 1.8 01 2810 4420 00 40 / 1½ 40 / 1½ 124 / 4.9 72 / 2.8 72 / 2.8 01 2810 5520 00 50 / 2 50 / 2 144 / 5.7 89 / 3.5 89 / 3.5 01 2810 6620 00 63 / 2½ 63 / 2½ 122 / 4.8 95 / 3.7 95 / 3.7 01 Aluminium nipple socket male (NPT thread) 2810 18 AIRnet Ø MALE OUTLET Ø DIMENSIONS L W H 2810 1018 00 20 / ¾ 12.5 / ½ 69 / 2.7 36 / 1.4 36 / 1.4 01 2810 1118 00 20 / ¾ 20 / ¾ 71 / 2.8 36 / 1.4 36 / 1.4 01 2810 2118 00 25 / 1 20 / ¾ 82 / 3.2 45 / 1.8 45 / 1.8 01 2810 2218 00 25 / 1 25 / 1 85 / 3.3 45 / 1.8 45 / 1.8 01 2810 4318 00 40 / 1½ 32 / 1¼ 124 / 4.9 72 / 2.8 72 / 2.8 01 2810 4418 00 40 / 1½ 40 / 1½ 124 / 4.9 72 / 2.8 72 / 2.8 01 2810 5418 00 50 / 2 40 / 1½ 140 / 5.5 89 / 3.5 89 / 3.5 01 2810 5518 00 50 / 2 50 / 2 144 / 5.7 89 / 3.5 89 / 3.5 01 2810 6518 00 63 / 2½ 50 / 2 137 / 5.4 92 / 3.6 92 / 3.6 01 2810 6618 00 63 / 2½ 63 / 2½ 141 / 5.6 92 / 3.6 92 / 3.6 01 2810 7618 00 80 / 3 63 / 2½ 148 / 5.8 113 / 4.4 113 / 4.4 01 2810 7718 00 80 / 3 80 / 3 151 / 5.9 113 / 4.4 113 / 4.4 01 ADAPTOR UNION In most geometries, AIRnet pipes provide enough flexibility to easily disconnect them from the fittings. In some exceptions, however, the pipe might not provide enough flexibility for easy dismantling. The adaptor union is a handy alternative to disconnect a pipe from the network without the need to bend the pipe. Adaptor union female (NPT thread) 2810 14 AIRnet Ø FEMALE OUTLET Ø DIMENSIONS L W H 2810 2214 00 25 / 1 25 / 1 106 / 4.2 45 / 1.8 45 / 1.8 01 2810 4414 00 40 / 1½ 40 / 1½ 163 / 6.4 72 / 2.8 72 / 2.8 01 2810 5514 00 50 / 2 50 / 2 188 / 7.4 89 / 3.5 89 / 3.5 01 2810 6614 00 63 / 2½ 63 / 2½ 199 / 7.8 110 / 4.3 110 / 4.3 01 2810 7714 00 80 / 3 80 / 3 251 / 9.9 130 / 5.1 130 / 5.1 01 18

PRODUCT CATALOG FITTINGS While also nipple sockets can be used to end your network, this usually requires more appropriate point of use connectors of a smaller diameter. WALL MOUNTED NIPPLE Wall mounted nipples are specifically designed to end your distribution line with 2 threaded outlets. Available in female outlets of Ø12.5 mm (½ ) or Ø20 mm (¾ ), they can be connected to any device. 1 2 3 4 5 6 OUTLET ORIENTATION Not horizontal, but pointed towards the floor for security reasons in case a coupler is dislocated under pressure. CONNECTED Ø Available in Ø20 mm (¾ ) or Ø25 mm (1 ) to match the drop leg diameter. BRASS OUTLETS Ø Robust; resistant to several assemblies. OUTLETS Ø Available in 1/2 BSP or 1/2 NPT DRAIN VALVE The lowest point requires a frequent, simple check for condensate contamination. QUICK ASSEMBLY 4 screws against a wall. Wall mounted bracket (NPT thread) 2810 24 AIRnet Ø FEMALE OUTLET Ø DIMENSIONS L W H 2810 1024 00 20 / ¾ ½ 100 / 3.9 68 / 2.7 110 / 4.3 01 2810 2024 00 25 / 1 ½ 100 / 3.9 68 / 2.7 114 / 4.5 01 Threaded wall mounted nipple (NPT thread) 2810 26 AIRnet Ø FEMALE OUTLET Ø DIMENSIONS L W H 2810 0026 00 12.5 / ½ ½ 100 / 3.9 68 / 2.7 111 / 4.4 01 2810 1026 00 20 / ¾ ½ 100 / 3.9 68 / 2.7 115 / 4.5 01 END CAP End caps are often used to temporarily end a network section in anticipation of a future extension. End cap 2810 06 Ø DIMENSIONS L W H 2810 1006 00 20 / ¾ 59 / 2.3 36 / 1.4 36 / 1.4 01 2810 2006 00 25 / 1 72 / 2.8 45 / 1.8 45 / 1.8 01 2810 4006 00 40 / 1½ 109 / 4.3 72 / 2.8 72 / 2.8 01 2810 5006 00 50 / 2 129 / 5.1 89 / 3.5 89 / 3.5 01 2810 6006 00 63 / 2½ 149 / 5.9 92 / 3.6 92 / 3.6 01 2810 7006 00 80 / 3 155 / 6.1 113 / 4.4 113 / 4.4 01 19

FITTINGS PRODUCT CATALOG THREADED AIRnet BALL VALVE A network can also be ended by means of a threaded valve. AIRnet is compatible with standard industrial ball valves, using a nipple socket to connect the valve to the AIRnet installation. To maintain equipment, it is advised to isolate the equipment from the compressed air system. Threaded AIRnet valve (NPT thread) 2810 53 Ø DIMENSIONS L W H 2810 1153 00 20 / ¾ 120 / 4.7 70 / 2.8 100 / 3.9 01 2810 2353 00 25 / 1 127 / 5.0 75 / 3.0 100 / 3.9 01 2810 4453 00 40 / 1½ 200 / 7.9 105 / 4.1 140 / 5.5 01 2810 5553 00 50 / 2 209 / 8.2 125 / 4.9 150 / 5.9 01 2810 6653 00 63 / 2½ 170 / 7.0 185 / 7.3 310 / 12.2 01 2810 7753 00 80 / 3 200 / 8.2 200 / 8.2 330 / 13.0 01 FLANGES Flanges Description Ø (mm) H (mm) 2810 6054 00 Flange diam 63 185 95 01 2810 7054 00 Flange diam 80 200 120 01 0650 0100 16 Flat Gasket diam 63 - - 01 0650 1001 27 Flat Gasket diam 80 - - 01 SPARE PARTS Inner Parts 2810 60 O-ring 2810 65 / 2810 66 Ø 2810 1060 00 20 / ¾ 05 2810 2060 00 25 / 1 05 2810 4060 00 40 / 1½ 05 2810 5160 00 50 / 2 05 2810 6060 00 63 / 2½ 05 2810 7060 00 80 / 3 05 Ø 2810 1065 00 20 / ¾ 10 2810 2065 00 25 / 1 10 2810 4065 00 40 / 1½ 10 2810 5065 00 50 / 2 10 2810 6065 00 63 / 2½ 10 2810 7065 00 80 / 3 10 2810 1066 00 Quick drop 20 / ¾ 10 2810 2066 00 Quick drop 25 / 1 10 20

PRODUCT CATALOG ACCESSORIES ACCESSORIES FLEXIBLE HOSES Flexible hoses are high quality hoses for compressed air, which comply with industrial standards. Their PN16 complies with the operating limits of AIRnet equipment. AIRnet hose outlets are fully compatible with AIRnet fittings. Hoses can be used for many purposes: to bypass obstacles, to absorb vibration, or to create an expansion loop. AIRnet hose NPT 2810 57 LENGTH (m / ft) Ø CONNECTION TYPE 2810 1057 00 0.75 / 2.5 20 / 3/4" straight 01 2810 1157 00 1.5 / 4.9 20 / 3/4" straight 01 2810 2057 00 0.75 / 2.5 25 / 1" straight 01 2810 2157 00 1.5 / 4.9 25 / 1" straight 01 2810 4057 00 1 / 3.3 40 / 11/2" elbow 90 01 2810 4157 00 1.5 / 4.9 40 / 11/2" straight 01 5810 5057 00 1 / 3.3 50 / 2" elbow 90 01 2810 5157 00 1.5 / 4.9 50 / 2" straight 01 Protection strap against whiplash 2810 55 The strap prevents the flexible hose from lashing should it become disconnected. Conform to ISO 4414 safety standards. TYPE 2810 0055 00 For Ø12.5-32 mm (½ -1¼ ) hoses 01 2810 0055 01 For Ø40-80 mm (1½ -3 ) hoses 01 CONNECTIONS The BSP connectors are made of brass, and are mostly used to make the wall mounted bracket and quick drop threaded outlets (also made of brass) compatible with various types of equipment. As the anodization of aluminium fitting prevents any risk of corrosion, also aluminium nipple sockets can be used to make the connection. It is highly recommended to use appropriate sealing material to ensure that the system remains leakage-free. 21

ACCESSORIES PRODUCT CATALOG AIRLINE ACCESSORIES We have selected the most popular airline accessories from the Atlas Copco Tool Catalog. The below sequence provides examples to typical assembly parts to fulfill the major application requirements. Please note the distinction we make with regard to the type of application of your plant, being heavy or low duty. Feel free to select only certain items from the sequence, as items are individually available and delivered separately. NPT accessories From AIRnet male nipple socket to a pneumatic tool via FRL (Filter Regulator Lubricator) for heavy duty application (Max. 30 l/s) PART NUMBER FRL ASSEMBLY FOR HEAVY DUTY APPLICATION (Max. 30 l/s) INLET Ø (inch) OUTLET Ø (inch) 9093 0015 02 Complete FRL air Prep unit - FRD 15CU-B 1/2" f 1/2" f 01 8202 1125 23 ErgoQIC 10 M15U Quick coupling for connection for ready made hose 1/2" m 1/2" 01 8202 1180 22 Ready made hose 5m (Heavy Duty) 1/2" 1/2" m 01 8202 1225 22 ErgoNIP 10 M15U 1/2" 01 * Only when connected to a male nipple socket Ø20 mm (¾ ) outlet. From AIRnet male nipple socket to a pneumatic tool via FRL (Filter Regulator Lubricator) for low duty application (Max. 22 l/s) PART NUMBER FRL ASSEMBLY FOR LOW DUTY APPLICATION (Max. 22 l/s) INLET Ø (inch) OUTLET Ø (inch) 9093 0015 02 Complete FRL air Prep unit - FRD 15CU-B 1/2" f 1/2" f 01 8202 1125 23 ErgoQIC 10 M15U Quick coupling for connection for ready made hose 1/2" m 1/2" 01 8202 1180 79 Ready made hose 5m (Low Duty) 1/2" 3/8" m 01 8202 1225 14 ErgoNIP 10 M10U 1/2" 01 * Only when connected to a male nipple socket Ø20 mm (¾ ) outlet. FRL description & characteristics Temperature range (at 10 bar): Max. working pressure (up to +25 C): Outlet connection thread: Total FRL weight: 0 C to +50 C 16 bar inlet ½ BSP 1.85 kg Flow capacity at 8 bar inlet pressure and with a 6.3 bar outlet pressure: Inlet pressure (min. / max.): Outlet pressure (min. / max.): Lowest differential pressure: 32 l/s 0 / 16 bar 0.5 / 8 bar 0.2 bar Filter - Water separation Semi-automatic drainage Separation of particles larger than about 15 μm as standard. Flow capacity at 6.3 bar inlet pressure and with a pressure drop of 0.2 bar: 38 l/s Maximum condensate in the bowl: 6 cl 0.6 0.4 Pressure drop (bar) Inlet pressure 4, 6.3, 8 bar 4 6.3 8 ~ 253 BSP ½ Ø48 BSP ½ Oil fog lubricator with plastic bowl for tools in long time operation. Constant rate of oil drop per minute. Oil refilling under pressure through the filler plug. Flow capacity at 6.3 bar inlet pressure and with a pressure drop of 0.15 bar: 38 l/s Maximum oil capacity in the bowl: 12 cl 0.6 0.4 Pressure drop (bar) Inlet pressure 4, 6.3, 8 bar 4 6.3 8 0.2 0.0 20 40 60 80 100 Air flow (l/s) 189 0.2 0.0 Air flow (l/s) 22

0.6 PRODUCT CATALOG ACCESSORIES NPT accessories From AIRnet threaded quick drop or wall mounted bracket to a pneumatic tool via a 20 m (65.6 ft) PVC hose for low duty application (Max. 22 l/s) The below sequence is connected to either a Ø12.5 mm (½ ) or Ø20 mm (¾ ) threaded quick drop outlet or a Ø12.5 mm (½ ) wall mounted bracket outlet. PART NUMBER POINT OF USE CONNECTION WITH PVC HOSE FOR LOW DUTY APPLICATION (Max. 22 l/s) Inlet Ø (inch) Outlet Ø (inch) 0605 8350 58 Bushing connection 3/4" m 1/2" f 01 0347 6104 00 Hose clamp for above 1/2" 1/2" 01 9093 0057 91 Rubber Hose 20m - 30l/s - 30l/s 1/2" 1/2" 01 0347 6104 00 Hose clamp for above 1/2" 1/2" 01 8202 1120 10 ErgoQIC 10 1/2" 1/2" 01 8202 1225 22 ErgoNIP 10 nipple 1/2" 1/2" m 01 * Only when connected to a quick drop Ø20 mm (¾ ) outlet. From AIRnet threaded quick drop or wall mounted bracket to a pneumatic tool via a 20 m (65.6 ft) PVC hose for low duty application (Max. 22 l/s) The below sequence is connected to either a Ø12.5 mm (½ ) or Ø20 mm (¾ ) threaded quick drop outlet or a Ø12.5 mm (½ ) wall mounted bracket outlet. PART NUMBER POINT OF USE CONNECTION WITH PVC HOSE FOR LOW DUTY APPLICATION (Max. 22 l/s) Inlet Ø (inch) Outlet Ø (inch) 0605 8350 58 Bushing connection 3/4" m 1/2" f 01 0347 0122 11 Hose clamp for above 1/2" 1/2" 01 9093 0036 01 Rubber Hose 20m - 30l/s - 22l/s 1/2" 1/2" 01 0347 0122 11 Hose clamp for above 1/2" 1/2" 01 8202 1120 10 ErgoQIC 10 1/2" 1/2" 01 8202 1225 14 ErgoNIP 10 nipple 3/8" 3/8" m 01 * Only when connected to a quick drop Ø20 mm (¾ ) outlet. ErgoQIC & QIC S description & characteristics ErgoQIC is effective in operation, safe and easy to handle. Its unique design eliminates flow resistance, resulting in an extremely low pressure drop. The ball valve swivels through 75 for quick connection / disconnection and safe operation. Flow capacity at 6 bar inlet pressure and with a pressure drop of 0.2 bar: 48 l/s Max. pressure: 16 bar Temperature range: -10 C to +70 C Nominal flow diameter: 9.4 mm Connection 1. Slot in 2. Straighten up Disconnection 3. Press together 4. Bend back 0.5 0.4 0.3 0.2 0.1 ΔP (bar) Air flow (l/s) QIC S couplings are the perfect solution to change hoses from one air tool to another, or to make fast connections to an air outlet. Flow capacity at 6 bar inlet pressure and with a pressure drop of 0.2 bar: 20 l/s Max. pressure: 16 bar Temperature range: -20 C to +80 C Nominal flow diameter: 7.1 mm 0.6 ΔP (bar) 0.5 0.4 0.3 0.2 0.1 Air flow (l/s) 23

0.5 m 0.1 m b ACCESSORIES PRODUCT CATALOG From AIRnet threaded quick drop or wall mounted bracket to a blow gun via a spiral hose (Max. 7 l/s) The below sequence is connected to either a Ø12.5 mm (½ ) threaded quick drop outlet or a Ø12.5 mm (½ ) wall mounted bracket outlet. PART NUMBER PVC HOSE ASSEMBLY FOR LOW DUTY APPLICATION (Max. 22 l/s) INLET Ø (inch) OUTLET Ø (inch) 0605 8300 89 8202 0508 70 Bushing to connect a Ø12.5 mm (½ ) m to a Ø6 mm (¼ ) f Short spiral hose for blow gun. Male threaded Ø6 mm (¼ ) BSP ½ m ¼ f 01 ¼ m ¼ m 01 0657 5764 00 Gasket for above. Ø6 mm (¼ ) BSP ¼ m ¼ m 01 OR 8202 0508 72 8202 1005 51 Long spiral hose for blow gun. Male threaded Ø6 mm (¼ ) BSP Blow GUN F06 A-S. With safety nozzle. Ø6 mm (¼ ) f* ¼ m ¼ m 01 ¼ f 01 * The safety nozzle deflects the air sideways if the forward air flow is blocked, with a maximum of 2 bar in case of direct contact (compliant with US OSHA Standards). Spiral hose description & characteristics D INSIDE Ø MAX. FLOW (l/s / cfm / m 3 /h) MAX.LENGTH (m / ft) INLET AND OUTLET Ø 8202 0508 70 6.5 / 0.26 7 / 14.8 / 25.2 <2.0 / <6.6 6 / ¼ 8202 0508 72 6.5 / 0.26 5 / 10.6 / 18.0 <4.0 / <13.1 6 /¼ Balancer to connect the hose to lighten the use of the pneumatic tool PART NUMBER 8202 0703 09 PVC HOSE ASSEMBLY FOR LOW DUTY APPLICATION (Max. 22 l/s) RIL 5 balancer allows setting of weight at desired height / capacity 0.4-2.3 kg (0.9-5.1 lbs) / wire length 2.4 m (7.9 ft) 01 PRESSURE GAUGE Use a threaded quick drop to install pressure gauges at any point in your network to inform the end user on the system pressure. Pressure gauge MALE INLET Ø 1503 2729 01* 6 / ¼ 01 * Use a bushing 0605 8300 89 to connect from a Ø12.5 mm (½ ) threaded quick drop outlet. 24

PRODUCT CATALOG INSTALLATION MATERIAL INSTALLATION MATERIAL HANGING BRACKETS The AIRnet range includes a large variety of hanging brackets to facilitate all possible assembly alternatives. It is important to select the appropriate brackets to reduce the required installation time. A beam clamp, for example, can be installed much faster than cantilever arms fixed to concrete walls. Three items are essential to hang pipes efficiently. All are available in this catalogue: the AIRnet pipe clip with integrated nuts; M8 threaded rod or T-bolts; hanging brackets. It is recommended to fix pipes of standard length onto a minimum of two hanging points. PROFILE CHANNEL ARMS Please respect the maximum weight allowed for a specific arm length. Profile channel arms TYPE DIMENSIONS L W H 2810 0030 00 Profile channel (2 m / 6.6 ft) 2000 / 78.7 30 / 1.2 27 / 1.1 05 2810 0031 00 Profile wall bracket 50 / 2.0 76 / 3.0 114 / 4.5 05 2810 0032 00 300 / 11.8 27 / 1.1 05 Cantilever arm 2810 0132 00 500 / 19.7 27 / 1.1 01 2810 0033 00 30 / 1.2 10 2810 0133 00 40 / 1.6 10 T-bolt 2810 0233 00 60 / 2.4 10 2810 0333 00 80 / 3.1 10 2810 0034 00 Protection cap 30 / 1.2 18.5 / 0.7 10 25

INSTALLATION MATERIAL PRODUCT CATALOG PIPE CLIP & CLIP SPACER Atlas Copco s pipe clips are designed to secure the pipes, which slide into the clip to compensate for any possible movement. The pipe clip s design also facilitates dismantling the system, when needed. Only AIRnet pipe clips should be used to secure AIRnet pipes. Pipe clip 2810 22 Ø C DIMENSIONS JDJDJ W H 2810 1022 00 20 / ¾ M8 56 / 2.2 30 / 1.2 31 / 1.2 20 2810 2022 00 25 / 1 M8 60 / 2.4 30 / 1.2 38 / 1.5 20 2810 4022 00 40 / 1½ M8 101 / 4 40 / 1.6 60 / 2.4 20 2810 5022 00 50 / 2 M8 108 / 4.3 40 / 1.6 75 / 2.8 20 2810 6022 00 63 / 2½ M8 118 / 4.6 40 / 1.6 94 / 3.7 20 2810 7022 00 80 / 3 M8 162 / 6.4 50 / 2 118 / 4.6 20 ød 6 m / 20 ft MIN 150 mm / 6 D max = 3 meter A minimum of two pipe clips is required to secure a pipe length. The clip spacer compensates for the gap which is created when connecting pipes of a different diameter, and makes sure the network remains perfectly aligned. Clip spacer 2810 27 PART NUMBER 2810 0027 00 2810 0127 00 Ø 20 / ¾ 25 / 1 40 / 1½ 50 / 2 63 / 2½ DIMENSIONS L W H 30 / 1.2 49 / 1.9 30 / 1.2 10 30 / 1.2 94 / 3.7 40 / 1.6 10 26

PRODUCT CATALOG INSTALLATION HANGING TO A BEAM I OR H PROFILE Hanging to a beam I or H profile 1 2 3 DIMENSIONS TYPE L W H (beam thickness) 2810 0035 00 36 / 1.42 18 / 0.71 2-3 / 0.08-0.12 10 2810 0135 00 36 / 1.42 18 / 0.71 3-8 / 0.12-0.31 10 Push-in beam clamp (1) 2810 0235 00 36 / 1.42 18 / 0.71 8-14 / 0.31-0.55 10 2810 0335 00 36 / 1.42 18 / 0.71 14-20 / 0.55-0.79 10 2810 0036 00 Screw beam clamp (2) 36 / 1.42 18 / 0.71 18 / 0.71 10 2810 0038 00 64 / 2.52 19 / 0.75 1-4 / 0.04-0.16 10 Hang clamp (3) 2810 0138 00 64 / 2.52 19 / 0.75 4-7 / 0.16-0.28 10 OTHER HANGING SOLUTIONS Other hanging solutions 1 2 3 TYPE DIMENSIONS L W H 2810 0037 00 U-bolt beam clamp (1) 70 / 2.8 43 / 1.7 10 2810 0039 00 Roof clamp (2) 25 / 1 10 2810 0050 00 Canalis hanger (3) 200 / 7.9 59 / 2.3 30 / 1.2 05 27

GRIPPLE PRODUCT CATALOG The Gripple hanger range is a safe, efficient and fast alternative to hanging brackets. It is perfectly designed to suspend AIRnet piping and is compatible with the complete line of AIRnet pipes, regardless of diameter, length of pipe or suspension distance required. The Gripple range can be suspended from beams and purlins, trusses, concrete, metal and wooden structures and can be easily configured to suspend multiple lines from one fastener. LOOP HANGER Applications The loop end fixing is an ideal method for choking around: Bar joists Purlins Beams Roof trusses Unistrut channel Other accessible building features Product Advantages Quick and safe choke knot installation No need for nuts, bolts, beam clamps, purlin clips or other accessories Up to 6 times faster installation compared with threaded rod, strap or chain Loop End Fixing Size Loop Specifications Size No. 2 Weight range holds up to 100 lbs The above size has a 5:1 safety factor. Available in lengths of 5ft or 15ft as standard. Kit Contents: 5' or 10' hanger Gripple Gripple key D C B A A (Nominal) inches B (Nominal) inches C inches No. 2 1 3 / 16 2 3 / 8 ½ D inches 5 / 16 How to Use 1 3 4 5 2 AIRnet piping installed with Gripple hanger. 28

PRODUCT CATALOG GRIPPLE STUD HANGER Applications The stud end fixing provides a quick method for installing services into: Concrete structures Metal decking structures Metal brackets using nuts Clamps and clevis hangers with ¼ or ³ 8 female threads Product Advantages Quick installation into concrete using drop-in anchors or nuts Drop-in-anchors or nuts supplied free as part of the kit Available in ¼ size Stud End Fixing Size Stud Specifications Size Weight range Thread No. 2 22-100 lbs ¼ The above size has a 5:1 safety factor. Available in lengths of 5ft or 15ft as standard. All standard Gripple studs are manufactured from mild steel which is zinc coated for maximum anti-corrosion properties. A B Kit Contents: 5' or 10' hanger Gripple Gripple key Expansion nut Size A inches B inches C inches No. 2 ¼ 1 2 C How to Use 1 3 2 4 All stud products can be attached to the suspended service by using either nuts or inserting into a female thread on the service. AIRnet piping installed with Gripple hanger. 29

GRIPPLE PRODUCT CATALOG 90 O EYELET HANGER Applications Designed for fixing into concrete, steel and wood: Suitable for suspending all types of services 9 32 hole allows any suitable ¼ fastener or anchor to be used in concrete Product Advantages Versatile can be attached to concrete using a variety of ¼ anchors or fasteners Designed for shot firing into concrete, steel and wood using gas and powder actuated tools Quick and safe saving time on installation 90 o Eyelet Fixing Size 90 o Eyelet Specification Size No. 2 Weight range 22-100 lbs The above size has a 5:1 safety factor. Available in lengths of 5ft or 15ft as standard. Kit Contents: 5' or 10' hanger Gripple Gripple key Screw The 90º Gripple eyelet end fixing is made from zinc plated steel. Size A inches B inches C inches A B C No. 2 9 32 7 8 1½ How to Use 1 2 3 Light fixing Pre-fabricated module systems AIRnet piping installed with Gripple hanger. 30

PRODUCT CATALOG GRIPPLE BARREL HANGER Applications Designed to work with a ¼ male thread, this ¼ female threaded barrel unit is suitable for: Fixing signage and light fixtures to ¼ T-bar twist clip on suspended ceilings. ¼ bolts or screws Product Advantages Aesthetic finish provides a clean look Quick installation Screw onto ¼ T-bar twist clip or ¼ bolt Cable is an integral part of barrel fixing with an end stop Barrel End Fixing Size Size No. 2 Weight range 22-100 lbs Barrel Specification The Gripple barrel end fixing is made from zinc plated steel. The above size has a 3:1 safety factor. Available in lengths of 5ft or 15ft as standard. Kit Contents: 5' or 10' hanger Gripple Gripple key Barrel end fi xing Does Not Include: Tools AIRnet pipe clip Size A inches B inches C inches No. 2 ¼ ½ 1 3 16 C B A How to Use 1 2 Image For use with AIRnet pipe clips. AIRnet piping installed with Gripple barrel fixing. 31

GRIPPLE PRODUCT CATALOG Y-FIT PIPE HANGER Applications Y-Fit pipe hanger provides a quick and easy way to suspend pipework or conduit without the need for traditional supports and bearers Supplied as a complete kit which consists of a barrel Y-Fit hanger with metal support plate. Designed to support two pipes/conduit 3 8"-2 1 2". Spacing allows insulation to be fitted Y-Fit accessory suitable for long drops with standard Gripple hanger kits. Product Advantages Quick attachment of pipe/conduit brackets to barrel fixing Provides easy access to fit insulation to piping 50% less drilling with one single anchoring point Replaces conventional supports which require cutting and preparation on-site Ready to use kit Two legs provide support improving the center of gravity Y-Fit Pipe Hanger Fixing Size Y-Fit Pipe Hanger Specification Available in Gripple Hanger size No.2 Available in standard lengths of 5ft and 15ft Leg lengths 8" Y Fit bar can hold up to 5 pipe clips and can be made to order. Kit Contents: 5' or 10' hanger Gripple Gripple key Barrel fi xing (x2) Y Bar Nut & bolt 8" 8" Y-Fit Pipe Hanger Y-Fit Pipe Hanger with 2 Airnet pipe lips. How to Use 1 3 5 2 4 Shown with a third AIRnet pipe clip, nut & bolt. To install, insert bolt through pipe clip and Y Bar. Secure with nut. 32

PRODUCT CATALOG GRIPPLE INFORMATION (1) (2) (3) (4) (5) (6) TYPE DIMENSIONS WORKING LOAD 2810 0238 05 Loop 5 ft No. 2 5 2810 0238 10 Hangers Working Load Limit 10 2810 0338 05 (1) 15 ft 0-100 lbs 5 2810 0338 10 Loop 10 2810 0438 05 1/4 Stud 5 ft No. 2 5 2810 0438 10 Hangers Working Load Limit 10 2810 0538 05 (2) 15 ft 22-100 lbs 5 2810 0538 10 1/4 Stud 10 2810 0638 05 90 Degree 5 ft No. 2 5 2810 0638 10 Eyelet Working Load Limit 10 2810 0738 05 Hangers 15 ft 22-100 lbs 5 2810 0738 10 (3) 90 Degree Eyelet 10 2810 1038 05 Single Barrel 5 ft No. 2 5 2910 1038 10 Hangers Working Load Limit 10 2810 1138 05 (4) 15 ft 22-100 lbs 5 2810 1138 10 Single Barrel 10 2810 0838 05 5 ft No. 2 Y-Fit Pipe Hanger 5 2810 0838 10 (5) Working Load Limit 10 2810 0938 05 15 ft 0-200 lbs 5 2810 0938 10 Barrel Fixing 10 2810 0149 00 Tools N/A A purpose made tool for 1 (6) cutting wire rope. 33

TOOLS PRODUCT CATALOG TOOLS Regardless of the diameter, installing an AIRnet pipe takes less than 5 minutes and does not require training. AIRnet INSTALLATION CD-ROM The AIRnet Assembly Video demonstrates the best practices to assemble AIRnet fittings in the shortest possible time. 2810 0095 00 Order your AIRnet Installation CD-ROM to assist you. AIRnet TOOLBOX Order your complete AIRnet ToolBOX to assemble Ø20-50 mm (¾ - 2 ) pipes and quick drops. AIRnet ToolBOX 2810 0145 00 PART NUMBER TYPE DESCRIPTION 2810 1228 00 AIRnet spanner Ø20-25 mm (¾" - 1 ) 2810 4047 00 AIRnet spanner Ø40 mm (1½ ) 2810 5047 00 AIRnet spanner Ø50 mm (2 ) 2810 0048 00 L key Quick drop assembly 2810 0029 00 AIRnet pipe marker For all diameters 2810 0040 00 Aluminium pipe cutter The pipe cutter for large diameters (2810 0140 00) is supplied individually 2810 0141 00 Aluminium pipe deburrer 2810 0042 00 Hole deburrer 2810 0043 00 Drill bit Only heavy duty model to cover all diameters up to Ø50 mm (2 ) For Ø19 mm (¾ ) / for quick drops reduced to Ø25 mm (1 ) 2810 0143 00 Drill bit For Ø12.5 mm (½ ) / for quick drops reduced to Ø20 mm (¾ ) 2810 0044 00 Drill bit holder TOOLSET To assemble Ø63-80 mm (2½ - 3 ) pipes. Toolset PART NUMBER TYPE DESCRIPTION 2810 6047 02 AIRnet spanner Ø63 mm (2½ ) 2810 7047 02 AIRnet spanner Ø80 mm (3 ) 2810 0029 00 AIRnet pipe marker For all diameters 2810 0140 00 Aluminium pipe cutter Only for diameters larger than Ø40 mm (½ ) 2810 0241 00 Aluminium pipe deburrer Ø63 (2½ ) / To be used with an electrical driller 2810 0341 00 Aluminium pipe deburrer Ø80 mm (3 ) / To be used with an electrical driller 2810 0148 00 Side Fluid Water-based 34

INSTALLATION GUIDE INSTALLATION GUIDE Cut the pipe 2810 40 Ø20-25 mm / ¾ - 1 Ø40-50 mm / 1½ - 2 Ø63-80 mm / 2½ - 3 2810 0040 00 2810 0040 00 2810 0140 00 01 Deburr the pipe 2810 41 Ø20-25 mm / ¾ - 1 Ø40-50 mm / 1½ - 2 Ø63-80 mm / 2½ - 3 2810 0041 00 2810 0141 00 2810 0241 00* 01 2810 0141 00 2810 0341 00** 01 * For Ø63 mm / 2½ only, to be used with a driller. ** For Ø80 mm / 3 only, to be used with a driller. Mark the pipe 2810 29 Ø20-25 mm / ¾ - 1 Ø40-50 mm / 1½ - 2 Ø63-80 mm / 2½ - 3 2810 0029 00 2810 0029 00 2810 0029 00 02 35

INSTALLATION GUIDE Prepare the pipe with side fluid 2810 48 Push the tube into the fitting Ø20-25 mm / ¾ - 1 Ø40-50 mm / 1½ - 2 Ø63-80 mm / 2½ - 3 2810 0148 00* 01 * Water-based / grease-free. Tighten the fitting 2810 47 Ø20-25 mm / ¾ - 1 Ø40-50 mm / 1½ - 2 Ø63-80 mm / 2½ - 3 2810 1228 00* 2810 4047 00** 2810 6047 00**** 02 2810 5047 00*** 2810 7047 00***** 02 * Tighten by hand. ** For Ø40 mm / 1½ only, one spanner required. *** For Ø50 mm / 2 only, one spanner required. **** For Ø63 mm / 2½, two spanners required. ***** For Ø80 mm / 3, two spanners required. 36

INSTALLATION GUIDE Quick drop assembly 2810 48 ITEM DESIGNATION Ø20-25 mm / ¾ - 1 Ø40-50 mm / 1½ - 2 Ø63-80 mm / 2½ - 3 Drill bit 2810 0043 00 2810 0143 00 2810 0143 00 01 Drill bit holder 2810 0044 00 2810 0044 00 2810 0044 00 01 Deburrer 2810 0042 00 2810 0042 00 2810 0042 00 01 L key 2810 0048 00 2810 0048 00 2810 0048 00 01 37

INSTALLATION GUIDE Things to consider before installation What do you want to achieve with your compressed air distribution network? Bring the required pressure to the exact point of use with a minimal pressure drop. The pressure drop is the pressure loss between the point of generation (compressor outlet) and the point of use (pneumatic equipment). Transport the air to the exact point of use to increase the efficiency of the manufacturing process. Make sure the air quality remains the same at the quality air equipment outlet as at the various points of use, and this over time. Use safe installation material and safe fixture systems. Perform the installation with minimum downtime. The system can be pressurized immediately after assembly. Anticipate future requirements, and provide the necessary flexibility for future evolution. To reduce downtime, the selected installation material should enable an extension or maintenance of the network in minimum time. To reduce investment costs, the selected installation material should be reusable. AIRnet meets all of the above requirements. What is the furthest point pressure drop? The furthest point pressure drop is the difference in pressure between the point of generation and the furthest point in your installation. A high pressure drop means the regulating pressure on the compressor needs to be set higher to compensate for the pressure drop. As a 1 bar (15 psi) additional operating pressure results in about 7% higher energy consumption, pressure drops drastically increase the electrical bill. 38

INSTALLATION GUIDE The pressure drop is influenced by various factors which we can classify from highest to lowest impact: The pipes inner diameter Increasing the pipes inner diameter reduces the pressure drop but increases the investment. Free air delivery The air demand of all downstream equipment connected to the portion of network. The friction factor Related to the pipe s material. Aluminium has a very low friction factor as opposed to galvanized pipes. The length of the network The longer the network, the higher the pressure drop. The structure It is recommended to build a ring in order to reduce your pressure drop. Working pressure When the working pressure is lower, the pressure drop increases. How do you evaluate the pressure drop in a typical installation? Base your calculation on the loading pressure of the compressor. ΔP before service for filters Each fitting has a ΔP. A simple geometry reduces ΔP. Initial ΔP of dryers -0.2 bar (-2.9 psi) -0.05 bar (-0.72 psi) Regulating P 7.5 > 7.0 bar (108.8 psi > 101.5 psi) -0.2 bar (-2.9 psi) -0.35 bar / Filter (x2) (-5.07 psi / Filter (x2)) -0.2 bar (-2.9 psi) -0.05 bar (-0.72 psi) -5.85 bar (84.84 psi) ΔP = 1.15 bar (16.66 psi) Always design your network so that the loading pressure at the compressor (7.0 bar) is minimized in order to reduce energy consumption. Always anticipate some pressure flexibility, e.g. if the furthest point pressure requirement is 5.9 bar (85.57 psi), the network specification of the above example would have to be reviewed. These data are only valid when the network consists solely of Atlas Copco equipment designed to guarantee a low pressure drop. 39

INSTALLATION GUIDE Step by step installation specifications Get your plant dimension drawing Identify the major air demand locations ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////// /////////////////////////////////////////////////// /////////////////////////////////////////////////// /////////////////////////////////////////////////// ////////////////////////////////////////////////////////////////////////////// Parts Storage LCD Panel Manufacturing Compressor Room Clean Room Air Lock Frame Assembly Quality Control Area Final Assembly Plastic Injection Molding Shipping Packaging Clean Room Machinery Compressed Air Equipment Storage Bay Identify the major air demand locations, including the location of the compressor. Evaluate the consumption level of these locations to make a distinction between high volume consumers (requiring a distribution line) and low volume, point of use consumers (requiring a quick drop). 40

INSTALLATION GUIDE Create a network skeleton main ring distribution line cross ring lines drop legs For more information regarding the main ring, distribution lines, and cross ring lines, please refer to pages 11. Drop legs are connected to the main ring, and supply air to the exact point of use. Available in a 20 mm (3/4 ) or 25 mm (1 ) diameter, they are typically short: between 5 to 20 m (16.5 to 65.6 ft). Validate the hanging solution for your network layout Make sure that the construction of your plant allows you to install the network layout you create. Keep in mind that the selected hanging solution should be safe, and should require the least possible installation time. Atlas Copco offers multiple hanging systems to fit any plant construction. Define the diameters of your network sections The diameter of the main ring is generally based on the capacity of all compressors connected to the network. The diameter of the distribution line or quick drop is usually based on the total air demand of all users connected to the system. Always keep possible future network extensions in mind. This way, it s possible to anticipate the network diameter needed to absorb future requirements. At this point, you have validated the furthest pressure drop of the system. We also recommend standardizing the diameters to limit the number of references used to build the network. This increases efficiency and facilitates future extensions. The diameters of the network depend on the system s pressure drop, which in turn depends on multiple parameters. The air demand is often the most critical criterion to evaluate. 41

INSTALLATION GUIDE DIAMETER SECTION TABLE Based on network length, excluding fitting equivalent length. How to select your main ring diameter? A few examples. STRAIGHT LENGTH or TOTAL RING LENGTH /2 Working pressure 7 bar (101.5 psi) Pressure drop 0.4 bar (5.8 psi) feet meter 6562 2000 6234 1900 6906 1800 Given: The total air demand is 105 l/s (at 7 bar / 101.5 psi) with a total ring length of 420 m (1378 ft). Solution: The above table recommends using pipes with a 63 mm (2½ ) diameter. The crossing is located in the starting zone of the Ø63 mm (2½ ) section, which means the pressure drop is probably below 0.2 bar (2.9 psi). Selecting a 50 mm diameter (2 ) would result in a pressure drop exceeding 0.5 bar (7.3 psi). 5577 1700 5249 1600 4921 1500 4593 1400 4265 1300 3937 1200 3609 1100 Given: 3281 1000 2953 900 2625 800 A customer would like to know the maximum air demand allowed in an existing distribution line of 670 m (2198 ft) designed in a 63 mm (2½ ) diameter. 2297 700 1969 600 1640 500 1312 400 984 300 656 200 Solution: The above table recommends using a maximum air consumption of 150 l/s for a pressure drop of 0.4 bar (5.8 psi). Ø80 mm / 3 Ø63 mm / 2½ Ø50 mm / 2 328 100 Ø40 mm / 1½ Ø25 mm / 1 Ø20 mm / ¾ 0 10 20 30 40 50 60 70 80 90 100 150 200 250 300 350 400 450 500 0 0 21 42 63 85 106 127 148 170 191 212 0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8 5.4 6.0 318 9.0 424 12.0 530 15.0 636 18.0 742 21.0 848 24.0 954 27.0 1059 30.0 l/s cfm m3/min AIR DEMAND 42

INSTALLATION GUIDE Evaluate special network configurations Bypassing major obstacles may require hoses in order to limit the pressure drop in a complex AIRnet geometry. Can the quick drops length and design be standardized or should they be customized to each point of use? Valves can be used to isolate network sections. Long straight lines may require expansion loops in order to absorb the dilatation. Long straight pipes can expand or contract due to temperature variations. To compensate for this effect, expansion loops are required. The number of expansion loops depends on the total length of the straight line and the maximum temperature variation. ΔL ΔL Fixed hanging point Fixed hanging point H Long straight length ΔL ΔL H Long straight length Fixed hanging point ΔL is the variation in length. H is the maximum distance between fixed points as determined by the numbers of pipe clips required to hang a pipe (Ø20-25 mm (¾ - 1 ): H = <1.5 m / Ø40-80 mm (1½ - 3 ): H = <2 m). Provided that the hanging point matches the maximum H distance, the below table clarifies the maximum possible straight distance vs. the temperature variation. DT Ø20 mm / ¾ Ø25 mm / 1 Ø40 mm / 1½ Ø50 mm / 2 Ø63 mm / 2½ Ø83 mm / 3 5 C / 41 F 211 m / 692 ft 168 m / 551 ft 187 m / 614 ft 150 m / 492 ft 119 m / 390 ft 94 m / 308 ft 10 C / 50 F 159 m / 522 ft 127 m / 417 ft 141 m / 463 ft 113 m / 371 ft 90 m / 295 ft 71 m / 233 ft 20 C / 68 F 107 m / 351 ft 85 m / 279 ft 95 m / 312 ft 76 m / 249 ft 60 m / 197 ft 47 m / 154 ft 30 C / 86 F 80 m / 262 ft 64 m / 210 ft 71 m / 233 ft 57 m / 187 ft 45 m / 148 ft 36 m / 118 ft 40 C / 104 F 64 m / 210 ft 52 m / 171 ft 57 m / 187 ft 45 m / 148 ft 36 m / 118 ft 29 m / 95 ft When the length of the straight line exceeds the maximum, expansion loops are required to compensate for the variation in length. > L max 43

INSTALLATION GUIDE Connection manufacturing processes Inventory the numbers of thread inlets and outlets in your compressor room to define the nipple sockets requirements. What type of connection will you use to connect your system to the various points of use? Can these be standardized to wall mounted connections? Finalize the bill of material Tick off the below checklist to make sure nothing is forgotten: Do you have all necessary equipment for a smooth and successful installation? AIRnet pipes AIRnet fittings Pipe clips S-bend to reduce the distance between the pipe and the wall Special equipment, like hoses and valves Nipple sockets to connect from and to the manufacturing process Bushing or reducing equipment Hanging brackets Assembly tools Lifting equipment Additional quick drops for possible future extensions Have you calculated the required assembly and hanging time? The standard length of an AIRnet pipe is 6 m or 20 ft. As some pipes need to be cut, the required number of pipes does not equal the total length of the network divided by 6 (when calculated in meters) or 20 (when calculated in feet). 44

INSTALLATION GUIDE The AIRnet Planner Since most customers like to visualize their future installation, and because we want to offer them the flexibility to adjust, modify and validate their future installation, Atlas Copco has developed unique 3D software to quote installation jobs. More than just a presentation tool for our end-users, the AIRnet Planner provides a detailed network structure and calculates the pressure drop in the system. Starting from the 3D design, the AIRnet Planner creates the bill of material, specifies the exact number of pipes needed, lists all required AIRnet fittings and calculates the assembly time. Ask for your own 3D quotation! 45

Atlas Copco has a focus on exceeding customer needs with a culture built on ongoing interaction, long-term relationships, and a commitment to understanding each customer s process and objectives. As a result, every compressed air solution we create helps a cus- To better serve our customers, we have operations where our customers do business. Our Eastern, Central, Southern and Western regions each have their own direct Atlas Copco sales and service team, plus we have a nationwide network of Atlas Copco customer centers and authorized contracted independent distributors. We have four manufacturing facilities in the USA, including one in Wisconsin, two in Texas, and our state of the art Hill, South Carolina. Satisfying customer needs with ground-breaking integrated compressed air technology, quality air accessories and 24/7 service support enhanced with remote monitoring tools positions Atlas Copco as a leading global compressor manufacturer. Our unwavering commitment is to be First in Mind First in Choice for all your compressed air requirements. We are committed to your superior productivity through interaction and innovation. Central Region Eastern Region Western Region Atlas Copco Compressors Corporate Headquarters Southern Region SPONSOR www.atlascopco.us 866-344-4887 1310 9056 76 FAB 12/09 1M Danger: Compressed air should never be supplied as breathing air unless air liability related to the purchaser s/user s breathing system. 2009 Atlas Copco Compressors LLC. All rights reserved. Atlas Copco is a registered trademark of Atlas Copoc AB The information contained herein is general in nature and is not intended for