User s Guide. GP911 Series Analog Gaging Transducers. GP911 Series M /14 Page 1 of 12

Similar documents
user leaflet GAUGING TRANSDUCERS

User s Guide. FLD100 and FLD100-FL SERIES Industrial Mass Flow Meter. Shop online at.

Servicing North America: For immediate technical or application assistance: Servicing Europe:

Owner s Manual Humiport 10/20

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User s Guide PG-CT COOLING ELEMENT. Shop online at omega.com. For latest product manuals:

Instruction Manual Model Borehole Pressure Cell

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

92831 TEL: (714) FAX:

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

ACCU-MIX 1200 / / 26270

WARNING NOTES TABLE OF CONTENTS

GILMONT ACCUCAL FLOWMETERS

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Corning Step-R. Repeating Pipettor. Instruction Manual

ROPV R40 E Series User Manual

GALISO SOAP OPTION FOR PCT-ADW-D

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Yoke Block Instruction Manual

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Digital Vacuum Regulator

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

AND OPERATION INSTRUCTIONS

ATEX ATEX

Yoke Block Instruction Manual

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

Models: C62/63/64-A/D

Model Series 62 Constant Differential Relay

Model ASSEMBLY and OPERATING INSTRUCTIONS

Color/Catalyst Dispense Valves

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

Instruction Manual No. 742, 8/98

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

! Warning, refer to accompanying documents.

FLANGED TWO-PIECE BALL VALVES

IMPORTANT SAFETY INSTRUCTIONS

Digital Vacuum Regulator

Model Series 63DL Differential Type Flow Controller

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

FLANGED TWO-PIECE BALL VALVES

92831 TEL: (714) FAX:

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

FPD20 Series. Gear wheel flow sensor

Cocoa Patio Pond with Lit Spillway

100C Air Compressor Kit

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

CSA Sample Draw Aspirator Adapter Operator s Manual

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

DIGIVAC 22W Series INSTRUCTION MANUAL. Wide Range Linearized Vacuum Transmitter and Controller YOU MUST READ THIS MANUAL BEFORE USE

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

High-performance submersible pressure transmitter For level measurement Model LH-10

RK-IR Sample Draw Aspirator Adapter Operator s Manual

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

CF-SERIES HIGH FLOW REGULATORS

Vessel Installation and Operating Manual

Certified ISO 9000 INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions

NOTES TABLE OF CONTENTS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

RAM 4021 Operation Manual

FLANGED MULTI-PORT BALL VALVES

AIR INLINE METAL SHEAR

200 PSI COMPRESSORS - MODEL NUMBERS

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

IMPORTANT SAFETY INSTRUCTIONS

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Constant Pressure Inlet (CCN) Operator Manual

P900. P900, Datenblatt Seite 1 DESCRIPTION

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Nitrogen Supply System

Transcription:

User s Guide http://www.omega.com e-mail: info@omega.com GP911 Series Analog Gaging Transducers Page 1 of 12

OMEGAnet On-Line Service http://www.omega.com Internet e-mail info@omega.com Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA SM Customer Service: 1-800-622-2378 / 1-800-622-BEST SM Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN SM TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico and Latin America: Tel: (95) 800-826-6342 FAX: (95) 203-359-7807 En Espan ol: (95) 203-359-7803 e-mail: espanol@omega.com Servicing Europe: Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: (31) 20 6418405 FAX: (31) 20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: nl@omega.com Czech Republic: ul. Rude armady 1868, 733 01 Karvina-Hranice Tel: 420 (69) 6311899 FAX: 420 (69) 6311114 Toll Free: 0800-1-66342 e-mail: czech@omega.com France: 9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 FAX: (33) 130-699-120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 FAX: 49 (07056) 8540 Toll Free in Germany: 0130 11 21 66 e-mail: info@omega.de United Kingdom: One Omega Drive, River Bend Technology Centre ISO 9002 Certified Northbank, Irlam, Manchester M44 5EX, England Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622 Toll Free in the United Kingdom: 0800-488-488 e-mail: info@omega.co.uk It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications. Page 2 of 12

Contents Product Description 4 Description... 4 Installation Recommendations... 4 Location & Clamping... 4 Tip Tightness... 5 Zero Adjustment... 5 Cable... 5 Pneumatic Options... 6 Adjustable Pretravel Option... 6 Environmental Considerations... 6 Electrical Connections for Use with Omega Electronics... 7 Quadrature Resistor... 7 Page 3 of 12

Product Description Description Omega Gaging Transducers are high precision measurement probes intended for all Gaging applications demanding high accuracy and a high degree of repeatability. The one piece parallel body houses a precision linear ball sleeve bearing assembly, anti-rotation guide and the choice of either a half bridge or a L.V.D.T. winding, a combination which adds up to an extremely versatile, accurate and cost effective measurement solution. Installation Recommendations Location & Clamping L.V.D.T. Gaging transducers generally are a reliable and proven technology that is well established in all areas of manufacturing and quality control. The majority of the associated problems experienced with their application and use are totally avoidable, particularly if sufficient thought is given during the initial design stages of equipment, to the position and clamping methods employed for these measuring elements. L.V.D.T. s being of inductive nature are susceptible to some degree to the influence of magnetic fields and therefore should be positioned well away from electric motors, relays and permanent magnets, where this is not possible then magnetic shielding should be considered as an alternative. Clamping of the probe body should be carefully considered, ideally the body of the transducer should be clamped in a pinch or yoke type clamp, if this is not possible then the introduction of a load spreading bush between body and clamp is a preferred alternative. Irrespective of clamping method care must be taken not to overtighten retaining screws as distortion of the body may prove damaging to the integrity of the transducer and adversely effect the geometry of the installation. Where single point screw clamping is adopted then the tightening torque employed should be limited to that which will give a maximum of 50Kg point load. The typical maximum torque for an M5x0.8mm or a 10-32UNF screw would be approximately 0.27Nm. Page 4 of 12

Tip Tightness Standard measuring tips are factory tightened to a torque of between 0.18Nm and 0.22Nm, this is sufficient to prevent loosening of the tip in use, but well within the damage threshold of the anti-rotation mechanism. It is recommended that replacement tips are tightened to the prescribed torque limits with the shaft fully retracted. A proprietary thread locking anaerobic sealant may be used sparingly if desired. Zero Adjustment This is best achieved by first positioning the Gage master, zeroing any electrical offset control, selecting the course set gain and moving the Gaging probe into contact with the master until the reading comes onto the scale. Gently tighten the clamp until it is just possible to fidget the probe manually towards the zero indication. As zero is approached, the instrument gain may be increased; when the zero point is within the range of the zero offset controls the clamp must be fully tightened. Any standard Omega probe used over the whole of its rated stroke should be mechanically set to within 0.004 (0.10mm) of true zero, if the measuring range is less than the rated stroke then the setting tolerance may be increased proportionally to within the limits of the available electrical offset. Cable The transducer cable is specially manufactured to company specification to achieve the optimum balance between flex life, flexibility, chemical resistance, abrasion resistance and electrical characteristics such as electrostatic screening. The following precautions will minimize transducer failure due to cable damage. Cable runs should be positioned well clear of moving components and vulnerable working areas. If the cable is in a flex situation then a minimum bend radius of 6 (150mm) should be maintained, the vacuum and pneumatic options should not be flexed from the transducer cable entry, but should be anchored separately at a position of 2-3 (50-75mm) from the end cap. Specials All non-pneumatic probes are provided with a cable strain relief spring as standard. This feature allows the user to retrospectively install a right angle cable outlet to aid space or cable routing restrictions. 1.181 30.0mm 0.315 8.0mm Dimension 0.335 8.5mm Page 5 of 12

Pneumatic Options The Gaging tip of pneumatic probes is normally biased in the inward direction and extension of the tip is achieved by applying air pressure to the probe nozzle. Air pressure may be varied within the specified limits to achieve the desired tip force at zero. The pneumatic probes are designed to be leak free and of small volume to minimize the air flow requirements and maintain a consistent tip force. Care must be taken not to damage the bellows seal as the satisfactory operation of the probe is entirely dependent on this component. A working clearance around the bellows equivalent to a 0.375 (9.5mm) dia. hole is desirable. To maximize the working life of the probes the air supply should be both clean and dry; i.e. filtered to better than 0.0002 (5 microns) and with a relative humidity of less than 60%. Operating Pressure Range for Standard Products : 0.4 Bar (6 psi) to 1.0 Bar (14 psi) Vacuum Option The Gaging tip of the vacuum operated probes is normally biased in the outward direction and retracted by the application of negative pressure within the specified ranges at the probe nozzle. Care must be taken not to damage the bellows seal as the satisfactory operation of the probe is entirely dependent on this component. Probes may be operated from a pumped system or individually from a hand operated bulb. Operating Pressure for Standard Products : 0.27 Bar (4 psi) maximum Adjustable Pretravel Option The option for adjustable pretravel is provided to maximize probe life and minimize component damage where side application of the Gaged component is necessary. Pretravel should be adjusted for minimum lift of the probe tip necessary for a satisfactory Gaging operation within the tolerance of the Gaged component. Pretravel should only be adjusted using the spanner. (ordered separately) The pretravel adjustment is not provided as a means of fine mechanical zero control, although it is possible to be used as such. Excessive use of the facility for zero adjustment can result in loss of electrical datum, resulting in possible damage to the internal stops. Environmental Considerations All non-pneumatic Gaging probes are specified to operate from +14 F to 176 F (-10 C to +80 C) and all pneumatic probes from 41 F to 176 F (+5 C to +80 C). At the low temperature extremes it may be necessary, due to stiffening, to remove the rubber gaiter to achieve satisfactory operation. In this case the atmosphere must be both clean and dry. However, continued operation without the gaiter is not recommended due to the damage caused by the ingress of dirt. Use of the transducer without the gaiter invalidates warranty. Omega probes are designed to withstand the rigors of in-process Gaging and will operate satisfactorily in the presence of copious amounts of coolants and cleaning solvents. Page 6 of 12

Electrical Connections for Use with Omega Electronics Quadrature Resistor These are supplied, where necessary to minimize residual voltage at null and should be fitted as follows: L.V.D.T.: Between yellow and white or yellow and green depending on phase (see calibration sheet for details). Yellow wire is not connected in optional factory fitted plugs. Half-Bridge: Between yellow and red or yellow and blue (see calibration sheet for details). BLACK CABLE SCREEN BLUE LVDT + WHITE YELLOW Case - GREEN RED Page 7 of 12

W-Series Application Notes When applying these probes the following pertinent points need to be observed in order to maintain the specification and to maintain continued reliable operation: 1) Air supply must be clean and dry, ie. Max 60% RH and filtered to particle size of 0.1 m. 2) The operating environment must be clean and dry. Viscous materials contaminating the probe shaft can inhibit operation and/or negate the properties of the low viscosity synthetic lubricating oils employed. 3) Replacing a contact tip should be approached with caution, the bearing assembly by default is delicate and any undue force can potentially damage the unit resulting in loss of free movement. Maximum tightening torque is 12 15 cnm. It is advised that the original supplier replace or fit custom tips, this ensures that the probe after testing will operate to specification, also if the mass of the tip differs from standard then any variance to the specification can be advised. 4) It is not recommended that the W-Series probes are subjected to side loading, as this can considerably shorten the useful working life. Page 8 of 12

This Page Intentionally Left Blank Page 9 of 12

This Page Intentionally Left Blank Page 10 of 12

WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC. Page 11 of 12

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gauges Load Cells & Pressure Gauges Displacement Transducers Instrumentation & Accessories FLOW/LEVEL Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers ph/conductivity ph Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial ph & Conductivity Equipment DATA ACQUISITION Data Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging Systems Recorders, Printers & Plotters HEATERS Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment ph, Conductivity & Dissolved Oxygen Instruments Page 12 of 12