Further technical information is available on

Similar documents
Operating Instructions

Operating Instructions

Operating Instructions

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

Manual Power relay SR853

Arran LED Floodlight Luminaire

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

VG5 Supplementary instructions

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

IECEx Certificate of Conformity

Flow controller Type ED/CCB311 Instruction manual

Actuating elements for ComEx

Pressure Measurement Single-range transmitters for general applications

GEMS SENSORS & CONTROLS

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Instructions for Safe Use

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

RTD temperature probes

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Technical Data. Dimensions

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Pressure controls for hydro carbons, zone II applications, Type KPE

Magnetic level switch type MR783 Instruction Manual

Junction Boxes Series 8118

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

DK48 - DK800. Quick Start. Variable area flowmeter

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

CFSW. Hinges with built-in safety multiple switch

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Pressure switch KP-E. Data sheet

IP65 Air Differential Pressure Switch

EX-RECESSED CEILING LIGHT FITTINGS

PURGEX X Purge Controller E Version. User s Manual

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. Dimensions

DK46 - DK800 Supplementary instructions

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Temperature gauge Installation Guide

MODELS (2 foot Version) (4 foot Version)

INSTRUCTION MANUAL Pressure Relief Device LPT

AutoChanger Installation & User Guide Issue 2

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

Pressure Measurement Single-range transmitters for general applications

Technical Data. General specifications. Rated operating distance s n 2 mm

CFSW. Hinges with built-in safety multiple switch

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

Pressure Switches Application Guideline

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

120 Series Explosion-Proof Pressure and Differential Pressure Switches

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Technical Data. Dimensions

Position switches FP series

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

INSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

PyroCouple Series Operators Guide

Technical Data. Dimensions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Instruction Manual Contact Pressure Vacuum Gauge

G96 Series BASOTROL Dual Operator Valve

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Pressure switches for air and water CS

INSTRUCTION MANUAL NI-281WE

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

ComEx Actuating elements

Norrsken Family Booklet

Installation and Operation Manual

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

PURGEX X Purge Controller D Version

Transcription:

1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas, the safety of personnel and equipment depends on compliance with the relevant safety regulations. The people in charge of installation and maintenance bear a special responsibility and it is essential that they have knowledge of the applicable rules and regulations. These instructions provide a summary of the most important safety measures and must be read by everyone working with the product. The instructions to be kept for future reference and must be available throughout the expected life of the product. Technical specifications The equipment listed in this manual is certified according to the latest requirements of the ATEX Directive and the IECEx scheme. II 2 G Ex eb mb tb op is IIC/IIIC T4 Gb Max. Voltage 254 Vac, 50 60 Hz Tamb: -20 C to +60 C The certificate number is : ATEX : Presafe 16ATEX 8117X IECEx: PRE 16.0008X Label: Applicable standards EN 60079-0:2012 IEC 60079-0 :2011 EN 60079-7:2015 IEC 60079-7:2015 EN 60079-18:2015 IEC 60079-18:2014 EN 60079-28:2015 IEC 60079-28:2015 EN 60079-31:2014 IEC 60079-31:2013 Description Our backlight enclosure is made of stainless steel 316L.

2 of 5 Safety instructions The device must be installed, used and maintained in accordance with the following standards: EN 60079-14 (electrical installations in explosive gas atmosphere) EN 60079-17 (inspection and maintenance in hazardous areas) It is forbidden to change components, installation, wiring etc. without the prior consent of Bartec Technor AS. We cannot accept any responsibility for failure to observe these regulations Make sure of the compatibility between the information on the nameplate, the explosive atmosphere present, the area of use and ambient temperatures and surfaces. Any damage of the device can cause ineffective in the explosion-proof protection. The installation of the enclosure must be performed only by qualified, competent and authorized personnel. Abnormal use as well as the non-compliance with the instructions of the present document will invalidate the guarantee of the product. Manufacturer traceability is ensured only at the first known delivery destination. Transport, storage, Installation Check it the product has not been damaged during transport. If any, do the statutory reserves to the carrier Do not put into service damaged products Packaging Location storage Duration storage Open In a indoor clean location, without contact with external substances. Constant temperature (-40 C < T < +70 C). Air humidity below 50 %. 2 years or more if inspected regular for cleanness and mechanical damages.

3 of 5 Putting into service When mounting the enclosure ensure that there is no damages, especially inspect the gasket and cover of the equipment. TNCLS Backlights shall be installed on the Level Gauges by help of the Installation brackets delivered with the backlights. - The quantity of supplied brackets is as per below specified quantities. The quantity of - Installation Brackets to be used upon installation shall be as follows: 1 pair for enclosures with 1 module ( LED slot ). 2 pairs for enclosures with 2, 3 and 4 modules. Examples: TNCLS 34-1 (one module) : 1 pair TNCLS 34-3 (3 modules) : 2 pairs TNCLS 34-7, i.e. (34-4)+(34-3) : 4 pairs TNCLS 27-9, i.e. (27-4)+(27-4)+(27-1) : 5 pairs For High Pressure Level Gauges with larger nuts there is a special bracket with Ø32mm hole. See page 5. For Level Gauges with high temperatures (> +40 C) there shall be no mechanical contact (except through the installation brackets) between Level Gauge and Backlight, and hence there are special installation kits (brackets) to protect the Backlight against overheating. There are also special kits for installation of TNCLS Backlights upon low temperatures (< -20 C). TNCLS Backlights shall not be isolated if any heat tracing system is used, or the process temperature is higher than +60 C. Verify that the information on the label of the product is in accordance with the permissible conditions for the Ex area of the site of use (Group II: Surface Industries - Category 2: high level of protection for ATEX G for Gas EPL code - G = for Gas - IPxx: IP rating (waterproofness for solids and liquids). Check if there is a specific position of mounting. The wiring of the cable conductors must be made with a particular care. The conductor insulation must reach the terminal. The conductive core must not be damaged. Cables not to exceed the authorized maximal temperature. - Earthing/bonding. Each metal enclosure has an external connection facility for bonding. It is in reliable electrical contact with the internal earthing terminal and/or earth bar, as well as with any bonding terminals, - The size of the internal earthing terminals are in accordance with IEC 60079-0: 2007 Ed 5, clause 15 and Table 9. This implicates for internal earthing; (S: conductor) when S <= 16mm² then S PE = S when 16mm² < S <= 35mm² then S PE = 16 when S > 35mm² then S PE = 0.5S External bonding shall be connected - The gasket supplied with the Backlight is fixed on each side of the LED slots at the front of the Backlight (the face of the installation which will be in contact with the Level Gauge). Torque cover screws: 2 Nm - The backlights are installed as follows, see also arrangement examples on page 5. - The installation brackets shall normally be installed in the uppert and lowest fixing point on the enclosure (except 1- module units, which have one bracket position only). - The adjustment screw (2) connecting the two parts of the installation brackets shall be unscrewed as far as possible before fitting the bracket onto the Level Gauge. - The installation brackets to be installed as horizontal as possible. Adjustments can be done by the 3 holes in part B of the bracket.

4 of 5 - All adjustment screws on the brackets to be firmly tightened. - When connecting cables, ensure that the incoming cables/wires are isolated from all sources of power during installation and until the cover is mounted on the enclosure. - Provide effective equipotential connection with a conductor with a cross-sectional area of at least 4mm². - For other installation applications, contact Bartec Technor for further information. Standard and High Pressure Installation High/Low Temperature

5 of 5 Installation Before starting Make sure the unit has been correctly mounted and not damaged Make sure the wiring and the tightening of the terminal screws have been performed properly. (See tightening torque for terminals in manufacturers descriptive documents) The cable gland must be tightened (See gland torque for glands in manufacturers descriptive documents see description of the) The device shall not include any foreign objects and check that no part are damaged Perform the dielectric test between terminals and earth with: (1 000 + 2U) V or 1500V whichever is the greatest for 60 seconds. During the test no electrical arcing shall occur. The test shall be performed using calibrated measuring equipment. The measuring equipment should have a calibration not extending one year. Maintenance The maintenance and repairs works on devices must be made only by authorized and trained persons for that purpose. Before any work the devices must be switched off. In addition: Prevent and avoid any formation of layers of dusts: make a periodic cleaning with a wet cloth The following checks must be made at least once a year: The outdoor equipment and surfaces must not be damaged The cable entries and blanking plugs must be tightened Check tightness of the connections, rewiring if necessary Prior to closing, check the cleanliness of the gasket and screws. Special Conditions for safe use (X): To be used in an area where there is low risk of mechanical danger.