QTi DALI/DIM / QTi GII / QTP5

Similar documents
QTi DALI/DIM / QTi GII / QTP5

QTi DALI/DIM / QTi GII / QTP5

LUMILUX T5 HO CONSTANT

QT-FIT8 2X58-70/ VS20

QT-FIT8 2X58-70/ VS20

DULUX L LUMILUX DE LUXE

DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION 1.

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed fixtures.

POWERBALL HCI -TC. Technical Information. POWERBALL HCI -TC for enclosed luminaires.

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed luminaires.

HCI-TT 250 W/942 NDL PB

HCI-T 70 W/942 NDL PB

HCI-T 70 W/942 NDL PB

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

PrevaLED Linear Slim 2

Residential Road_Lighting Class S5

POWERSTAR HQI -TM 600 and 1000W POWERBALL HCI -TM 250 and 400W

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA

T5 Retail Sales. 2011, September 8 data subject to change

Photometric Test Report

CURION 185 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 80 EN60598 / EN62031 / EN62471 >25 >25.

SPORTS: Single Tennis court 24x11m for class III

SPORTS: Single Tennis court 24x11m for class III

EX-RECESSED CEILING LIGHT FITTINGS

Less power great performances

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

Mirror with Socket

LED Lightsource-R High Bay - EU

LED Lightsource-R High Bay - EU

The AR111 LED is ideal solution for spot lighting in shops

Technical data: SCHUCH quality - Your advantage:

LED Down Light (8 ) Dimension:

Experience bright and vivid colors

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES. For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

Technical data: SCHUCH quality - Your advantage:

code: NEWS _EN s/p LED 2016 NEWS 02 -EN

HALODIUM II. Product family datasheet. Outdoor flood- and spotlights. Areas of application _ Facades and monuments _ Parks

LM LUMEN MAINTENANCE TEST REPORT

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

Light Engines. Data Sheets. Nix II Series. Oberon II Series. Pluto II Series. Titan II Series. Mercury II Series. Aries II Series.

LED lighting systems

TUV Low Pressure Mercury

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

POWERED BY IP66 IK08 LM-80 LED URBAN LIGHT. LED Urban Light

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Instruction and Maintenance Manual

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

Product Specification Spring Finger

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

CK Series. 3-way jaw long stroke chuck double acting/single acting. Operational stroke length: 20, 40mm. Specifications. Switch specifications

User Manual PTW-DensiX. D / Di/Zi

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

T-CITY. Waterproof protection for LED lighting

Aperval Pressure Regulators

LAMP 339-9SUGSURSUBC/S1174

A smooth design solution for a seamless look

INSTRUCTION MANUAL Pressure Relief Device LPT

Examination lamps OBSERVA ALFALED A06 L88 ALFA

Verdi G-Series Family

COMFORT LED. The new TECO range

LED FLOOD LIGHTING SPORTS LIGHTING CASE STUDY. Yankee Stadium. New York USA

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

Instruction and Maintenance Manual

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

A smooth design solution for a seamless look

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

A60 A65 YEAR MODEL. 100 mm VT w SKU: K WARM WHITE SKU: K DAY WHITE SKU: K WHITE. 37 mm MODEL SHAPE A60 VT

TECHNICAL DESCRIPTION

CONTOUR SPECIFICATION

Technical Data Sheet 339-9SUGSURSUBC/S1182. Features. Descriptions. Applications. Device Selection Guide

High Frequency Chip Ceramic Inductor

wästberg w 132 nendo

FENCER Under Cabinet LED Light Fixture

Stance LED Pendant Indirect/Direct

LED T8 U-BEND DIRECTFIT PLASTIC SERIES UL TYPE-A

CABRIO LAMPS REFLECTORS CHARACTERISTICS LUMINAIRES LIGHT DISTRIBUTION THREE SIZES, MULTIPLE PHOTOMETRIC SOLUTIONS

LED Bulbs. Application

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

CFSW. Hinges with built-in safety multiple switch

CEAG HandRail LED. Hand rail mounted Luminaire for all applications

Table of Contents. Version 5.1. Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

333-2SURC/H3/S530-A4 LAMP. Features. Description. Applications. 1 Ver.:2 Release Date:12/13/2016 狀態 :Approved( 正式發行 )

NGP-250/500 Nitrogen Generator Quick Start Guide

204-10SDRD/S530-A3 LAMP. Features. Description. Applications. Revision 1. LifecyclePhase: Expired Period: Forever. Choice of various viewing angles

EALP05RDBRA0 LAMP. Features. Description. Applications. Choice of various viewing angles. Available on tape and reel. Reliable and robust

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Aluminum Capacitors +85 C, Miniature, Axial Lead

Photometric Data of Lamp

Harmonised standards used IEC kg 0.95 kg 0.90 kg 1.34 kg

OPTO Laboratory Testing Report

LED T5 - LINEAR REPLACEMENT TUBE DIRECTFIT COATED GLASS SERIES UL TYPE-A

LIMBA SUSPENDED LUMINAIRES

Transcription:

osram.com Reduce up to 10% of Energy usage even in existing systems QTi DALI/DIM / QTi GII / QTP5 TECHNICAL INFORMATION 01

Benefits Energy savings up to 10% compared to standard lamps Excellent economy and efficiency Payback less than 1 year Very good luminous flux maintenance throughout the life of the lamp Product Features Up tp 114 lm/w High efficacy Long average life time: up to 24,000 h (with QUICKTRONIC ) Good colour Rendering Group 1B (Ra 80-89) Fluorescent lamp with 16 mm diameter Light colors: Cool Daylight (865), Cool White (840), Warm White (830), INTERNA (827) Dimensions Description Base Length (l1) Length (l2) min Length (l2) max Length (l3) Tube Diameter (d) max 13 W G5 549 553.7 556.1 563.2 17 19 W G5 849 853.7 856.1 863.2 17 25 W G5 1149 1153.7 1156.1 1163.2 17 32 W G5 1449 1453.7 1456.1 1463.2 17 Electrical Data 1 Lamp Voltage in HF 2 mode rated [V] Lamp Current in HF mode rated [ma] 13W 69 185 210 19W 104 185 210 25 W 143 180 210 32 W 184 175 210 Pre-heat current rated [ma] 1 According to IEC 60081 (measurement with reference control gear) 2 High Frequency TECHNICAL INFORMATION 02

Photometrical Data 3 Light Color Color Rendering Index (CRI), Ra Target Color Coordinate X Target Color Coordinate Y Color Temperature [K] Nominal Flux Max. Flux Energy Efficiency Class 13 W 830 Warm White 80 89 0.440 0.403 3000 1150 1350 A 13 W 840 Cool White 80 89 0.380 0.380 4000 1150 1350 A 13 W 865 Cool Daylight 80 89 0.313 0.337 6500 1050 1300 A 19 W 830 Warm White 80 89 0.440 0.403 3000 1800 2100 A 19 W 840 Cool White 80 89 0.380 0.380 4000 1800 2100 A 19 W 865 Cool Daylight 80 89 0.313 0.337 6500 1750 2000 A 25 W 827 INTERNA 80 89 0.463 0.420 2700 2450 2900 A 25 W 830 Warm White 80 89 0.440 0.403 3000 2450 2900 A 25 W 840 Cool White 80 89 0.380 0.380 4000 2450 2900 A 25 W 865 Cool Daylight 80 89 0.313 0.337 6500 2260 2750 A 32 W 827 INTERNA 80 89 0.463 0.420 2700 3100 3650 A 32 W 830 Warm White 80 89 0.440 0.403 3000 3100 3650 A 32 W 840 Cool White 80 89 0.380 0.380 4000 3100 3650 A 32 W 865 Cool Daylight 80 89 0.313 0.337 6500 2870 3500 A Relative Flux / Ambient Temperature For more detailed information please refer to our technical guide for Fluorescent Lamps. Free download at www.osram.com. 3 Measurement in accordance with EN 60081, annex C and the relevant annex on rated colour characteristics in IEC 60081. TECHNICAL INFORMATION 03

Lifetime 4 B50 7 Service life time 8 ECG 5 (IEC 60929) preheat IEC 60081 switching cycle 6 24,000 h 18,000 h LLMF 9 20.000 h 0.90 LLMF 16.000 h 0.90 LLMF 12.000 h 0.90 LLMF 8.000 h 0.81 LLMF 6.000 h 0.91 LLMF 4.000 h 0.92 LLMF 2.000 h 0.95 LSF 10 20.000 h 0.50 LSF 16.000 h 0.90 LSF 12.000 h 0.99 LSF 8.000 h 0.99 LSF 6.000 h 0.99 LSF 4.000 h 0.99 LSF 2.000 h 0.99 4 Measurement in accordance with EN 60081, annex C. 5 Electronic Control Gear 6 Switching cycle 165 min. on, 15 min. off (according to IEC 60081) 7 Average rated lamp life (B50) is the average value of the life time for an entity of lamps operated under standardized conditions until 50% failure. In other words, this is the operation time at which, for a standardized 3-hour switching cycle (165 minutes on / 15 minutes off (according to IEC)), 50% of a sample population of lamps have failed. 8 Service life time is the mathematical life time (maintenance multiplied with the % of failed lamps e.g. B10) for lamps in an installation after which the installation luminous flux (100 h value) decreased with 20 % (decrease in luminous flux and failed lamps) for indoor lighting. 9 Lamp Lumen Maintenance Factor (lamp luminous flux in %): Ratio of the luminous flux of a specific quantity of lamps at a defined number of hours of operation to their luminous flux at 100 h 10 Lamp Survival Factor (lamp survival in %): Ratio of the number of electrically intact lamps to the total number of lamps TECHNICAL INFORMATION 04

Logistic Data Description EAN 10 EAN 40 Packaging Unit 13W/830 4008321733818 4008321733825 40 13W/840 4008321733832 4008321733849 40 13W/865 4008321733856 4008321733863 40 19W/830 4008321733931 4008321733948 40 19W/840 4008321733955 4008321733962 40 19W/865 4008321733979 4008321733986 40 25W/827 4008321516909 4008321516916 40 25W/830 4008321516923 4008321516930 40 25W/840 4008321516947 4008321516954 40 25W/865 4008321516961 4008321516978 40 32W/827 4008321517067 4008321517074 40 32W/830 4008321517111 4008321517128 40 32W/840 4008321517166 4008321517173 40 32W/865 4008321517210 4008321517227 40 TECHNICAL INFORMATION 05

Lamp/ECG Combination Lamp ECG EAN 10 ECG 13 W 19 W 25 W Flux @25 C [W] IN [A] Factor ECG Efficacy [lm/w] Length Width Height Distance between holes QTi 1x14/24/21/39/220-240 GII 4008321383334 1150 15 0.07 0.91c 77 360 30 21 350-20 +50 QTi 2x14/24/21/39/220-240 GII 4008321383396 2300 29 0.125 0.95 79 360 30 21 350-20 +50 QTP5 1x14-35 4008321329035 1150 15 0.075 0.90c 77 280 30 21 270-20 +50 QTP5 2x14-35 4008321329073 2300 28 0.13 0.95 82 360 30 21 350-20 +50 QTP5 3x14, 4x14 4008321484598 3450 43 0.19 0.95 80 280 40 21 270-20 +50 QTP5 3x14, 4x14 4008321484598 4400 56 0.25 0.97 79 280 40 21 270-20 +50 QTi-DP 1x28/35/LED 4008321646521 1150 16 0.08 0.92c 72 423 30 21 415-20 +50 QTi 1x14/24/21/39/220-240 GII 4008321383334 1800 22 0.1 0.94c 82 360 30 21 350-20 +50 QTi 2x14/24/21/39/220-240 GII 4008321383396 3600 42 0.18 0.96 86 360 30 21 350-20 +50 QTP5 1x14-35 4008321329035 1800 22 0.1 0.95 82 280 30 21 270-20 +50 QTP5 2x14-35 4008321329073 3600 42 0.185 0.98 86 360 30 21 350-20 +50 QTi-DP 1x28/35/LED 4008321646521 1800 22 0.18 0.94c 82 423 30 21 415-20 +50 QTi 1x28/54/35/49 GII 4008321383358 2500 29 0.13 0.95 86 360 30 21 350-20 +50 QTi 2x28/54/35/49 GII 4008321383419 5000 56 0.26 0.96 89 360 30 21 350-20 +50 QTi 1x14/24/21/39 GII 4008321383334 2500 29 0.13 0.95 86 360 30 21 350-20 +50 QTi 2x14/24/21/39 GII 4008321383396 5000 56 0.26 0.96 89 360 30 21 350-20 +50 QTP5 1x14-35 4008321329035 2450 27 0.12 0.96 91 280 30 21 270-20 +50 QTP5 2x14-35 4008321329073 4900 54 0.24 0.98 91 360 30 21 350-20 +50 QTi-DP 1x28/35/LED 4008321646521 2450 29 0.13 0.97 84 423 30 21 415-20 +50 T a [ C] TECHNICAL INFORMATION 06

Lamp ECG EAN 10 ECG 32 W Flux @25 C [W] IN [A] Factor ECG Efficacy [lm/w] Length Width Height Distance between holes QTi 1x28/54/35/49 GII 4008321383358 3150 36 0.16 0.96 88 360 30 21 350-20 +50 QTi 2x28/54/35/49 GII 4008321383419 6300 68 0.31 0.96 93 360 30 21 350-20 +50 QTi 1x35/49/80 GII 4008321383372 3150 36 0.16 0.96 88 360 30 21 350-20 +50 QTi 2x35/49/80 GII 4008321174291 6300 70 0.33 0.97 90 425 30 21 415-20 +50 QTi 1x14/24/21/39 GII 4008321383334 3150 36 0.16 0.96 88 360 30 21 350-20 +50 QTi 2x14/24/21/39 GII 4008321383396 6300 68 0.31 0.96 93 360 30 21 350-20 +50 QTP5 1x14-35 4008321329035 3100 34 0.15 0.97 91 280 30 21 270-20 +50 QTP5 2x14-35 4008321329073 6200 68 0.30 0.98 91 360 30 21 350-20 +50 QTi-DP 1x28/35/LED 4008321646521 2900 36 0.16 0.98 81 423 30 21 415-20 +50 T a [ C] For more information on ECG refer to http://www.osram.com/ecg For more information on Guarantee refer to http://www.osram.com/guarantee In case of lamp breakage: www.osram.com/brokenlamp For more information technical Information see Technical guide. Free download at www.osram.com TECHNICAL INFORMATION 07