SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Similar documents
CCT-7320/ROC-2313 Reverse Osmosis Controller

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

Reverse Osmosis System Installation Guide and Operation Manual.

Autocalibration Systems For In Situ Oxygen Analyzers

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

Electronic gas volume corrector model DGVC-04

DTG - LCD Digital Temperature Gauge USER MANUAL

Best Practice Guide, Servomex 2700

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

TH-1800-T TRX-700-CNG Converter

EC214 EC215 - EC215R Bench Conductivity Meters

Autocalibration Systems for In Situ Oxygen Analyzers

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

SonoMeter 30 Energy Meters

Best Practice for Calibrating LTH Conductivity Instruments

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

HI 2314 HI 2315 HI 23151

Highest Quality. Gas Chlorination Systems

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Integral type Differential pressure flowmeter VNT Series

Columbus Instruments

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

6200 Isoperibol Calorimeter Model Number: 6200

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

ACV-10 Automatic Control Valve

Transmitter CS 21 Operation Manual

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Analytical Transmitters

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HumiSys HF High Flow RH Generator

Expert Hydrostatic Level Transmitters

analytical bulk flow distance FLOW level pressure temperature industrial communication

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

780S Ultra High Purity Series

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

BI-680 Online Dissolved Oxygen Controller Instruction Manual

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Pro-V Multivariable Flowmeter

Ultrasonic level transmitter and indicator

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Manual of SF6 Comprehensive Tester

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Operating Instructions Part No

CONTROL and INSTRUMENTATION

MODEL 269DF-LCF-LCF/WS FILLING SYSTEM

GAS FUEL VALVE FORM AGV5 OM 8-03

Automatic Isokinetic Sampler. ST5 Evo

Softmaster ROE 2. Microprocessor controllers for reverse osmosis plants. Operating instructions

Flamco Flamco-Fill STA Flamco-Fill STM

INTERPLANT STANDARD - STEEL INDUSTRY

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Flamco Flexcon M-P Pump automat

Tightness controls TC 1 3 and TC 4

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Operating Instructions Part No

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Zirconia Oxygen Analyzer Systems

AMT-Ex Dewpoint Transmitter

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

C-Flow Coriolis Mass Flow Meters

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

INSTALLATION & MAINTENANCE INSTRUCTIONS

AutoChanger Installation & User Guide Issue 2

Swell UK. The UK's leading online aquatic retailer.

Transmitter CS 21 Operation Manual

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Technical Information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

Features. Description

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Accelerated Corrosion Test Chambers

We measure it. For gas and water installers. testo hpa. bar

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

SINGLE VALVE WITH LOW-FLOW BYPASS

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Speed Controller ADR 40 Condensing pressure controller SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP

Pneumatic Target Transfer System Model PT01

Aquavar SOLO 2 Frequently Asked Questions

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

Model PDT Dewpoint Transmitter

Differential Pressure Transmiter

Quick Installation Guide Doc nr.: C Date:

RAM 4021-DPX Operation Manual

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

THERMAL MASS FLOW MEASUREMENT FOR GASES

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

RCD - Ultra-Rugged Differential Pressure Flowmeter

Installation and Operating Instructions for Blow Down Controller Type LRR 1-12

Transcription:

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE 1

TABLE OF CONTENTS 1. PURPOSE OF SUPPLY... 3 2. SYSTEM FUNCTIONING... 3 3. SYSTEM COMPONENTS... 4 4. BATTERY LIMITATIONS... 6 5. DOCUMENTATION... 6 6. GUARANTEE... 6 2

1. PURPOSE OF SUPPLY SWT-AP AUTOMATIC PURGE WATER TRATMENT SYSTEM can be considered as a starting point of the water treatment, but not less effective than more complex treatments. It has been planned according to the installation needs of the cooling towers, by basing on our many years experience and on the feedbacks received from our clients in their application fields. The system is composed essentially of a panel set up for the conductivity measurement and the purge automatic control (and optionally of the SWT1 products dosage part) consisting of : N 1 PE plate panel to be fixed to the wall; N 1 measurement system SCAM WATER CONTROL (SCAM/WCNT) equipped with conductivity analysis probe for the control of an automatic power-driven valve of purge on the tower water conductivity; N 1 set of hydraulic components (PVC pipe, manual spherical valves of interception, sample taking) pre-installed conductivity probe mount; N 1 supply switchboard with protection thermal magnet; N 1 spherical two-ways solenoid (of purge). 2. SYSTEM FUNCTIONING IN THE SWT-AP WATER TREATMENT SYSTEM the water coming from the spillage on the tower circuit (pos.1) passes through the PVC manual valve of the panel on the left side. Immediately it reaches a probe holding well where there is the conductivity meter. The conductivity probe, equipped with compensation temperature sensor, measures the conductivity value of the circulating water and compares this to the limit value set by the user (set-point). If the measurement exceeds the said set-point, the panel proceeds with the opening of the solenoid on the tower purge drain (pos.2) in order to also drain the satured water. The water flowing out the probe well passes through a sample taking, before overcoming a PVC manual valve, and then introduced one again in the recycling circuit of the cooling tower (pos.3). 3

Figure 1 Schematic representation of SWT- AP system. 3. SYSTEM COMPONENTS In SWT-AP system, the measurement and control electronic instrument SCAM WATER CONTROL SCAM/WCNT, specifically designed to be applied on cooling towers, provides the conductivity measurement by means of a conductive probe through a 4 20 ma signal, by which it automatically activates a purge solenoid. A backilluminated matrix LCD indicator allows the visualization of the process signal value and the different parameters by means of three led indicating the system operating steps (on, off, error). The instrument operates through a conductivity electrode which integrates a temperature sensor (Pt100 sensor) for the temperature compensation. Among the main functions it is possible to set an alarm on the maximum opening time of the drain valve. 4

Table 1 - Technical characteristics of the SCAM WATER CONTROL device Conductivity entry Measuring range 0,0 500/2000/5000 µs/cm 20 ms/cm Cell constant 0,006...12 cm-1 Accuracy 0,5% of the measuring range Resolution 0,0625% of the measuring range Input / Output Current output Single relay output Overall dimensions External dimensions Protection class Installation type Display type Power supply 4,00...20,00 ma programmable and proportional to the cond. contact 3A/250V for solenoid command 189x200x76H mm IP65 (for environments having an high humidity content) to a wall Illuminated with key protected access 230VAC / 50/60Hz Table 2 - Technical characteristics of the conductivity probe Measurement scale 0,1 20 ms/cm Cell constant 1 cm-1 ± 5% Temperature sensor Pt100 Max. temperature 70 C Max. pressure 16 bar (@ 50 C) Electrodes / body Steel 1.4571 / PP materials For the plant proper functioning is provided a power-driven purge valve which has to be properly installed hydraulically on the plant by the client and electrically wired (already predisposed) to the electrical panel of SCAM/ SWT- AP system. The purge valve will be not equipped with electric connection cables, meanwhile the conductivity probe will be already pre-wired to our electric panel, that the client will have to electrically supply. 5

4. BATTERY LIMITS The SCAM T.P.E. SRL supply limitations regarding SWT-AP @ AUTOMATIC PURGE system are the following: The flanges on the aspiration and supply pipe on the panel. The terminal glands on the control electrical cabinet. EXCLUSIONS FROM THE SUPPLY PURPOSE Structure of support to the panel and any civil work. Provision & installation of all the components on site. Wiring of electrical supply connections. Signal cables of the purge valve. 5. DOCUMENTATION The documentation that will be furnished to the client, will include the use and maintenance manuals of the instruments and purge valve. 6. GUARANTEE The contractual guarantee starts from the materials availability up to 24 months for all the electronic parts; up to 12 months for all hydraulic parts. The guarantee doesn t cover damages due to force majeur, neither damages against third parties and/or suppliers. The guarantee doesn t cover transport and onsite workforce costs. For a specific quote, please contact SCAM T.P.E. S.r.l. Commercial Department. 6