Exekon. Nuclear. ý C)C) ý. May 9, 2001 SVP U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.

Similar documents
Effects of Delayed RCP Trip during SBLOCA in PWR

An Improved Modeling Method for ISLOCA for RI-ISI and Other Risk Informed Applications

Verification and validation of computer codes Exercise

MDEP Common Position No AP

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

The Nitrogen Threat. The simple answer to a serious problem. 1. Why nitrogen is a risky threat to our reactors? 2. Current strategies to deal with it.

REGULATORY OBSERVATION

Safety Analysis: Event Classification

ON TRANSIENTS IN PUMA

DDnmm,-- SEP U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Mail Stop OP1-17 Washington, D. C

Loss of Normal Feedwater Analysis by RELAP5/MOD3.3 in Support to Human Reliability Analysis

EXPERIMENTAL SUPPORT OF THE BLEED AND FEED ACCIDENT MANAGEMENT MEASURES FOR VVER-440/213 TYPE REACTORS

Nuclear Grade Air Trap and Gas Void Management

"0/ UNITED STATES. Docket No

Field Evaluation of ASTM E in Relation to Control Room Habitability Testing and Boundary Maintenance in Nuclear Power Plants.

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Profile LFR-43 HELENA ITALY. Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone, Italy

Implementing IEC Standards for Safety Instrumented Systems

International Agreement Report

TEST BENCH FOR SAFETY VALVES

Workshop Information IAEA Workshop

HEALTH AND SAFETY EXECUTIVE HM NUCLEAR INSTALLATIONS INSPECTORATE

Regulatory requirements with respect to Spent Fuel Pool Cooling

Table 6: Schedule of Operational Commitments

Custom-Engineered Solutions for the Nuclear Power Industry from SOR

Technical Specification Bases Update to the NRC for Period Dated

Inspection Credit for PWSCC Mitigation via Peening Surface Stress Improvement

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

IAEA Headquarters in Vienna, Austria 6 to 9 June 2017 Ref No.: CN-251. Ivica Bašić, Ivan Vrbanić APoSS d.o.o.

Nuclear safety Lecture 4. The accident of the TMI-2 (1979)

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

Review and Assessment of Engineering Factors

August 31, CFR CFR ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C.

NE 405/505 Exam 2 Spring 2015

Accident Management Strategies for Mark I and Mark III BWRs

Extensive Damage Mitigation Guidelines (EDMG)

DETAILS OF THE ACCIDENT PROGRESSION IN 1F1

International Agreement Report

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

ASVAD THE SIMPLE ANSWER TO A SERIOUS PROBLEM. Automatic Safety Valve for Accumulator Depressurization. (p.p.)

PVS EVALUATING AOV AND MOV PERFORMANCE

ACCIDENT MANAGEMENT AND EPR AT DUKOVANY NPP

COMMERCIAL ITEM DESCRIPTION NITROGEN, TECHNICAL

DISTRIBUTION LIST. Preliminary Safety Report Chapter 19 Internal Hazards UK HPR1000 GDA. GNS Executive. GNS all staff. GNS and BRB all staff CGN EDF

Tools and Methods for Assessing the Risk Associated with Consequential Steam Generator Tube Rupture

Guidelines for Inservice Testing at Nuclear Power Plants

Analysis of Halden overpressure tests using the FALCON code

EMERGENCY CORE COOLING SYSTEM SIMPLIFICATION

Instrumentation systems of BWR

ICONE ASSESSMENT OF THE TRACE REACTOR ANALYSIS CODE AGAINST SELECTED PANDA TRANSIENT DATA

RISKAUDIT GRS - IRSN Safety assessment of the BELENE NPP

THE CANDU 9 DISTRffiUTED CONTROL SYSTEM DESIGN PROCESS

EUROPEAN COMMISSION 5th EURATOM FRAMEWORK PROGRAMME KEY ACTION: NUCLEAR FISSION

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Infiltration and Air Pressure Build-up

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

V.H. Sanchez Espinoza and I. Gómez-García-Toraño

PRA Methodology Overview

Committee on NFPA 85

Commandant United States Coast Guard

Comparison of MARS-KS to SPACE for counter current flow limitation model

Transient Analyses In Relief Systems

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER P: REFERENCE OPERATING CONDITION STUDIES (PCC)

~...,.. ~~-s_a_re_ty_c_o_m_m_is_s_io_n~-de~su_re_te_ n_u_c_lea_i_re~~~~~~~~~~~~~~~~~~-~ '

GUIDE YVL 3.7 / 26 Se p t e m b e r 2008

Every things under control High-Integrity Pressure Protection System (HIPPS)

SHUTDOWN SYSTEMS: SDS1 AND SDS2

Free Surface Flow Simulation with ACUSIM in the Water Industry

Assessment of Internal Hazards

Start-up of the Three-shaft Closed Loop

DRAFT REGULATORY GUIDE DG-1074

MELCOR code application to VVER440/V213 analyses

Assessing Combinations of Hazards in a Probabilistic Safety Analysis

Fukushima: Outside the Imagination and Lack of Preparation. Benefit of PST (Partial Stroke Test)

Classical Event Tree Analysis and Dynamic Event Tree Analysis for High Pressure Core Melt Accidents in a German PWR

Systems of Accounting for and Control of Nuclear Material

Research Article Remarks on Consistent Development of Plant Nodalizations: An Example of Application to the ROSA Integral Test Facility

Comparison of the partner s approaches for physical phenomena assessment in level 2 PSA

* William A. Sala, Jr. John A. Roscher. Columbia Gas Transmission, LLC * Sorana Linder 700 Louisiana Street, Suite 700 Director, Regulated Services

(C) Anton Setzer 2003 (except for pictures) A2. Hazard Analysis

-. 30ýv. Entergy ARKANSAS NUCLEAR ONE - UNIT I IMPROVED TECHNICAL SPECIFICATIONS SUBMITTAL. 05/01101 Supplement Volume 2 of 2. (Sections 3.7 and 3.

OIL AND GAS INDUSTRY

Experiment 8: Minor Losses

PI MODERN RELIABILITY TECHNIQUES OBJECTIVES. 5.1 Describe each of the following reliability assessment techniques by:

CONTENTS OF THE PCSR CHAPTER 1 - INTRODUCTION AND GENERAL DESCRIPTION

WHITE PAPER. SmartPlant P&ID Engineering Integrity 10 Example Rules

MADILL 24.7" 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Valve Sizing Considerations. Steven Hocurscak Metso Automation

Numerical simulation of the ALBA s synchrotron cooling system response to pump start-up and shut-down Page 1

THE NITROGEN INJECTION THREAT IN PWR REACTORS

Safety and efficiency go hand in hand at MVM Paks NPP

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

The Discussion of this exercise covers the following points:

HYDRAULIC JUMP AND WEIR FLOW

Unit 24: Applications of Pneumatics and Hydraulics

TRAFFIC IMPACT STUDY CRITERIA

Technical Support Note

Transcription:

Exelon Generation Ouad Cities Generating Station 22710 206th Avenue North Cordova, I L 61242-9740 Tel 309-654-2241 May 9, 2001 www.exelon corp.com Exekon. Nuclear SVP-01-059 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Quad Cities Nuclear Power Station, Units 1 and 2 Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265 Subject: Transmittal of 10 CFR 50.46, "Acceptance criteria for emergency core cooling systems for light water nuclear power reactors," Annual Report for Quad Cities Units 1 and 2 The purpose of this letter is to satisfy the annual reporting requirement for 10 CFR 50.46, "Acceptance criteria for emergency core cooling systems for light water nuclear power reactors," for the Quad Cities Nuclear Power Station. The attachments describe all changes in accumulated peak cladding temperature (PCT) since the last annual submittal. Should you have any questions concerning this letter, please contact Mr. Wally Beck at (309) 654-2241, extension 3609. Respectfully, Timothy J. Tulon Site Vice President Quad Cities Nuclear Power Station Attachments: Attachment A: Quad Cities Unit 1, 10 CFR 50.46 Report (GE Fuel) Attachment B: Quad Cities Unit 1, 10 CFR 50.46 Report (Framatone ANP Fuel) Attachment C: Quad Cities Unit 2, 10 CFR 50.46 Report (GE Fuel) Attachment D: Quad Cities Unit 2, 10 CFR 50.46 Report (Framatone ANP Fuel) Attachment E: Quad Cities Units 1 and 2, 10 CFR.46 PCT Assessment Notes ý C)C) ý cc: Regional Administrator- NRC Region III NRC Senior Resident Inspector - Quad Cities Nuclear Power Station

Attachment A Quad Cities Unit 1, 10 CFR 50.46 Report (GE Fuel) Page 1 of 2 PLANT NAME: ECCS EVALUATION MODEL: REPORT REVISION DATE: CURRENT OPERATING CYCLE: Quad Cities Unit 1 SAFER/GESTR-LOCA 5/11/01 17 ANALYSIS OF RECORD ECCS Evaluation Model: SAFER/GESTR-LOCA, NEDE-2401 1-P-A-8-US, May 1986 Calculation: General Electric document NEDC-31345P, Revision 2, dated July 1989 Fuel: P8x8R/BP8x8R, which bounds GE8, GE9 and GEI0 Limiting Fuel Type: P8x8R/BP8x8R, which bounds GE8, GE9 and GE10 Limiting Single Failure: Battery Failure Limiting Break Size and Location: 1.0 Double Ended Guillotine Recirculation Suction Line Break (on the following page)

Attachment A Quad Cities Unit 1, 10 CFR 50.46 Report (GE Fuel) Page 2 of 2 Reference PCT PCT= 1382 F A. PRIOR LOCA MODEL ASSESSMENTS Reported to USNRC on 11/8/99 2000 Annual 10 CFR 50.46 Report dated 5/12/00 Prior Assessments PCT +468 F PCT= 185 B. CURRENT LOCA MODEL ASSESSMENTS SAFER ECCS Leakage Flow Model Error (see Note 1) SAFER Time Step Change (See Note 2) Total PCT Change from Current Assessments Cumulative PCT Change from Current Assessments SAPCT = I APCTI = 0OF -5 0 F -5 0 F 5 0 F NET PCT PCT= 1845 F

Attachment B Quad Cities Unit 1, 10 CFR 50.46 Report (Framatome ANP Fuel) Page 1 of 2 PLANT NAME: ECCS EVALUATION MODEL: REPORT REVISION DATE: CURRENT OPERATING CYCLE: Quad Cities Unit 1 EXEM BWR 5/11/01 17 ANALYSIS OF RECORD Evaluation Model: Advanced Nuclear Fuels Corporation Methodology for Boiling Water Reactors EXEM BWR Evaluation Model, ANF-91-048(P)(A), dated January, 1993. Calculations: 1. "Quad Cities LOCA-ECCS Analysis MAPLHGR Limits for ATRIUMTM 9B Fuel," EMF-2348(P), Revision 0, Siemens Power Corporation, dated February 2000. 2. "LOCA Break Spectrum Analysis for Quad Cities Units 1 and 2," EMF-96-184(P), Siemens Power Corporation, dated December 1996. Fuel: ATRIUMTM-9B Limiting Fuel Type: ATRIUM T M-9B Limiting Single Failure: LPCI Injection Valve Limiting Break Size and Location: 1.0 (DEG) Double-Ended Guillotine in a Recirculation Suction Pipe (on the following page)

Attachment B Quad Cities Unit 1, 10 CFR 50.46 Report (Framatome ANP Fuel) Page 2 of 2 Reference PCT PCT = 1952 F A. PRIOR LOCA MODEL ASSESSMENTS 2000 Annual 10 CFR 50.46 Report dated 5/12/00 Prior Assessments PCT PCT= 1952 0 F B. CURRENT LOCA MODEL ASSESSMENTS Q1C17 Reload Fuel Assessment* Incorrect Wilson Bubble Rise Model in FLEX (see Note 3) Incorrect Momentum Equation in FLEX (see Note 4) Impact of FLEX Code Changes Due to Validation and Verification Activities (see Note 5) +3 0 F Total PCT Change from Current Assessments Cumulative PCT Change from Current Assessments SAPCT = SIArPCTI = +3 0 F 3 0 F NET PCT PCT= 1955 F * Quad Cities Unit 1 Cycle 17 Reload Analysis, EMF-2416, Rev. 0, dated August 2000.

Attachment C Quad Cities Unit 2, 10 CFR 50.46 Report (GE Fuel) Page 1 of 2 PLANT NAME: ECCS EVALUATION MODEL: REPORT REVISION DATE: CURRENT OPERATING CYCLE: Quad Cities Unit 2 SAFER/GESTR-LOCA 5/11/01 16 ANALYSIS OF RECORD ECCS Evaluation Model: SAFER/GESTR-LOCA, NEDE-2401 1-P-A-8-US, May 1986 Calculation: General Electric document NEDC-31345P, Revision 2, dated July 1989 Fuel: P8x8RJBP8x8R, which bounds GE8, GE9 and GEl0 Limiting Fuel Type: P8x8R/BP8x8R, which bounds GE8, GE9 and GE10 Limiting Single Failure: Battery Failure Limiting Break Size and Location: 1.0 Double Ended Guillotine Recirculation Suction Line Break (on the following page)

Attachment C Quad Cities Unit 2, 10 CFR 50.46 Report (GE Fuel) Page 2 of 2 Reference PCT PCT= 1382 F A. PRIOR LOCA MODEL ASSESSMENTS Reported to USNRC on 11/8/99 2000 Annual 10 CFR 50.46 Report dated 5/12/00 APCT= +468 F Prior Assessments PCT PCT= 1850'F B. CURRENT LOCA MODEL ASSESSMENTS SAFER ECCS Leakage Flow Model Error (see Note 1) SAFER Time Step Change (See Note 2) -5 0 F Total PCT Change from Current Assessments Cumulative PCT Change from Current Assessments APCT = I APCTI = -5 0 F 5 0 F NET PCT PCT = 1845 F

Attachment D Quad Cities Unit 2, 10 CFR 50.46 Report (Framatome ANP Fuel) Page 1 of 2 PLANT NAME: ECCS EVALUATION MODEL: REPORT REVISION DATE: CURRENT OPERATING CYCLE: Quad Cities Unit 2 EXEM BWR 5/11/01 16 ANALYSIS OF RECORD Evaluation Model: Advanced Nuclear Fuels Corporation Methodology for Boiling Water Reactors EXEM BWR Evaluation Model, ANF-91-048(P)(A), dated January, 1993. Calculations: 1. "Quad Cities LOCA-ECCS Analysis MAPLHGR Limits for ATRIUM TM_ 9B Fuel," EMF-2348(P), Revision 0, Siemens Power Corporation, dated February 2000. 2. "LOCA Break Spectrum Analysis for Quad Cities Units 1 and 2," EMF-96 184(P), Siemens Power Corporation, dated December 1996. Fuel: ATRIUMTM-9B Limiting Fuel Type: ATRIUMTM-9B Limiting Single Failure: LPCI Injection Valve Limiting Break Size and Location: 1.0 (DEG) Double-Ended Guillotine in a Recirculation Suction Pipe (on the following page)

Attachment D Quad Cities Unit 2, 10 CFR 50.46 Report (Framatome ANP Fuel) Page 2 of 2 Reference PCT PCT= 1952 F C. PRIOR LOCA MODEL ASSESSMENTS 2000 Annual 10 CFR 50.46 Report dated 5/12/00 OF Prior Assessments PCT PCT= 1952 F D. CURRENT LOCA MODEL ASSESSMENTS Q2C16 Reload Fuel Assessment* Incorrect Wilson Bubble Rise Model in FLEX (see Note 3) Incorrect Momentum Equation in FLEX (see Note 4) Impact of FLEX Code Changes Due to Validation and Verification Activities (see Note 5) Total PCT Change from Current Assessments Cumulative PCT Change from Current Assessments SAPCT = II APCTI = +3 0 F +3 0 F 3 0 F NET PCT PCT = 1955 F * In February 2000, Siemens reanalyzed ATRIUM-9B fuel with corrections made for all known computer code errors and modeling assessments previously reported. This provided a new analysis of record for Q2C16 as reported in the 2000 annual 10 CFR 50.46 report.

Attachment E Quad Cities Units 1 and 2, 10 CFR 50.46 PCT Assessment Notes Page 1 of 1 1. SAFER ECCS Leakage Flow Model In the GENE's SAFER LOCA analyses for some plants, the ECCS leakage flows had not been subtracted from the ECCS system flows. An evaluation was performed to determine the impact of the ECCS leakage on the PCT for the affected plant analyses. The Quad Cities units are not affected by this error. Reference: "10 CFR 50.46 Error Report - ECCS Leakage Flows in SAFER analysis", GE Letter, dated 9/15/00. 2. SAFER Time Step Change Per a recommendation of the BWROG audit of GENE's SAFER LOCA analysis process and methodology, an evaluation was performed to determine the impact of the time step size on LOCA calculations performed with SAFER04V. Smaller hydraulic and conduction time step sizes were recommended in the SAFER analyses for all plant types. The result is a decrease in PCT of 5 0 F for the Quad Cities Units 1 and 2. Reference: GE Letter, "Impact of SAFER Time Step Size on the Peak Clad Temperature (PCT) for Jet Pump Plant Analyses", dated 1118/00. 3. Incorrect Wilson Bubble Rise Model in FLEX The Wilson Bubble Rise model was implemented with an incorrect region slope in FLEX code. The calculated bubble rise velocity was affected and FLEX would produce less level swell during a transient. Quad Cities units were reevaluated using a version of FLEX with a correct transition point. There is no PCT (0 OF) impact for the Quad Cities units. References: 1. "10 CFR 50.46 PCT Reporting for Quad Cities Units", SPC Letter, D. Garber to R. J. Chin, DEG:00:208, dated 8/31/00. 2. 'FLEX V&V Findings", FANP Condition Report CR7806, Rev. 2, dated 10/2/00. 4. Incorrect Momentum Equation in FLEX The momentum equation for pipe geometry adjacent to the break is missing an area divider in the injection flow term in FLEX code. Quad Cities units were not affected by the error and there is no PCT (0 OF) impact. 1. "10 CFR 50.46 PCT Reporting for Quad Cities Units", SPC Letter, D. Garber to R. J. Chin, DEG:00:208, dated 8/31/00. 2. "FLEX V&V Findings", FANP Condition Report CR7806, Rev. 2, dated 10/2/00. 5. Validation and Verification Activities of FLEX Code Changes All the errors/deviations and code cleanup items in the reporting period were corrected and implemented and the V&V have been completed. Quad Cities units were reevaluated using the corrected version of FLEX. The result is an increase in PCT of 3 0 F for Quad Cities Units 1 and 2. 1. "10 CFR 50.46 PCT Reporting for Quad Cities Units", SPC Letter, D. Garber to R. J. Chin, DEG:00:208, dated 8131/00. 2. "FLEX V&V Findings", FANP Condition Report CR7806, Rev. 2, dated 10/2/00.