GENO -Flushing Compressor Product Data Sheet F 02

Similar documents
GENO -flushing compressor 1988 K operation manual

Installation and commissioning instructions 255 series and 256 series

3-Way Safety Block DSV

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

SIHI LPH-X - Liquid Ring Compressors

BY GREGGERSEN CATA LOG

Hot Water Stationary Unit

ELADOS EDP L Diaphragm Metering Pump Type

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

HERZ-Motorised flow controler

ScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Armatures for analytical probes

Operation manual Euro system separator GENO -DK 2 Euro system separator GENO -DK 2-Maxi Euro system separator GENO -DK-Maxi

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

14. Exploded View. Page 68

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

11. Spare Parts. applications since applications since

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

swimming pool technology

Compressed Airline Breathing Apparatus

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Full-Vacuum Chlorinator C 2212 MB / 1

4/2 way Pneumatic Solenoid Valve

Pressure and Flow Control Valves DBGM, German and European Patents

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Instructions for SILEX 1C Mixed bed cartridge filter

Type 4708 Supply Pressure Regulator

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Type 4708 Supply Pressure Regulator

Vaccuperm accessories

OPERATING INSTRUCTIONS

Inverse Proportional Pressure-Relief Cart., Size 2 4

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

GAS PRESSURE CONTROL UNIT TYPE 132

Inverse Proportional Pressure-Relief Cart., Size 2 4

Pressure reducing valves Index

Change-Over Pressure Filter DFDK

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Jet Swim Installation instruction

Gas Pressure Regulator HON 300

VB85/ Pressure regulating valve (Unloader)

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

B74G - EXCELON Modular System General purpose filter/regulator

System Pressure Manager Standard & System Pressure Manager Plus

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

InnoVfoam B.V. InnovDos Foam Proportioning System

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Pressure Reducing Valve DMV 750

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

VACCUPERM Vacuum chlorine gas dosing systems

CI-SfB 732 (5-1) x. - laboratory fittings

safety Shut-Off Valve HON 721

Inverse Prop. Pressure-Relief Cart., Size 2 4

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Old documentation - Only for your information! Product is not available anymore!

Type 4708 Supply Pressure Regulator

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Tightness control TC. Product brochure GB 3 Edition AGA

Model MTB-ASME Vertical Bladder Tanks

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Diaphragm pumps. Krautzberger GmbH / Subject to change

OWNER S TECHNICAL MANUAL

InnovDos Foam proportioning system

Compressed Air Conditioning Catalog Chapter I

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Proportional Pressure-Relief Cartridge Valve, Size 2...4

B84G - Excelon Plus Modular System General purpose filter/regulator

V5434T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION

TECHNICAL ACCESSORIES

Remeha Quinta Cascade guide

KSB Delta Compact Type Series Booklet

Siphon vessel / Priming aid

Self-operated Pressure Regulators for special applications

safety shut-off Valve HON 703 / HON 704

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Vertical Bladder Tanks

Water Safety Shut-off Valve HON 790

PULSAR4 Pressure regulating valve (Unloader)

Tightness controls TC 1 3 and TC 4

Model MTB-ASME Horizontal Bladder Tanks

Pressure reducing valves Series DRV/DRVM - DRVN/DRVMN

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Transcription:

GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up of drinking water installations as per DIN EN 806-4 and DVGW worksheet W 557, at a recommended minimum flow velocity of 0.5 m/s is possible up to DN 50: if one flushing compressor is used, DN 65 and DN 80: if two flushing compressors are connected in parallel, prior to the disinfection of drinking water installations as per DIN EN 806-4 and DVGW worksheet 557, prior to the dosing of mineral-based agents in case of corroded or silted pipes, at a recommended minimum flow velocity of 1.5 m/s up to DN 32: if one flushing compressor is used, DN 40 and DN 50: if two flushing compressors are connected in parallel, System disinfection* Disinfection of drinking water installations according to DIN EN 806-4 and DVGW worksheet 557 with GENO - Chlor A or GENO -perox by means of the optional dosing system GENODOS DM-SK. Design The GENO -flushing compressor 1988 K is a mobile, electronically controlled device in compact design, mainly consisting of: Carriage with closed, surrounding frame for easy transportation Oil-free compressor aggregate suitable for continuous operation Pressure tank with pressure switch and pressure indication Connection with quick-acting coupling for compressed air Pressure regulating unit for flushing air with filter, pressure indication and dosing unit for air pulses Water flow fitting with non-return valve, contact water meter and connection for air dosing Controller with program selector switch, LED display for continuous flow, air and dosing pulses. Function The following four functions may be selected at the controller of the flushing compressor: Flushing with water and air for the flushing of pipes with a water/air mix. is flown through by water provided by others on site. Volume-controlled addition of compressed air in periodic pulses in order to increase the flushing efficiency. The flushing air pressure automatically adjusts to a value which exceeds the existing water pressure. The water flow is indicated in the LED display in m³/h. Flushing with disinfection* For system disinfection (disinfection of a drinking water installation) with GENO -Chlor A or GENO -perox by means of the optional dosing system GENODOS DM-SK. is flown through by water provided by others on site. The disinfectant is added volume-proportionally into the dosing connection at the flushing compressor. The dosing pump is controlled by the controller of the flushing compressor and the dosing pulses are indicated at the LED display (for dosing systems and disinfectants, please refer to Accessories). If the disinfectant GENO -Baktox (chlorine dioxide) is going to be used, the separate and independent dosing system MOBIdos (without flushing compressor) must be used. Continuous air blast This function can be activated in order to increase the cleaning effect, e. g. in case of sanitation flushing. Compressed air In order to be able to supply compressed air, the GENO -flushing compressor1988 K features a standard connection for compressed air including a quick-acting coupling. Scope of supply GENO -flushing compressor 1988 K, complete and packed in cardboard box, with operation manual and 2 flexible connection hoses DN 25 (1 union nut), each 1.5 m long, with spare O-rings. * Note: For system disinfection we recommend the independent and mobile MOBIdos dosing system (order no. 160 150) which is fully equipped with a system separator and is suited for all three disinfectants GENO -perox (hydrogen peroxide), GENO -Baktox (chlorine dioxide) and GENO - Chlor A (sodium hypochlorite resp. chlorine) listed in the DVGW worksheet 577. Edition: 26.04.13 We reserve the right to modifications! Page 1 of 5 Supersedes: 17.01.13 Edited by: KONS/gmei-mrie g:\ PDB-F02-INTER_SPÜLKOMPRESSOR_1988K.DOC

Accessories Conversion kit for GENO -flushing compressors 1988 K up to year of construction 2011. To adapt a GEKA connection to the current connection technology with 2 flexible connection hoses. Order no. 151 850 Adjusting pieces For installation downstream of the initial filter at the entry of the water supply pipe into the house, e. g. to connect a flushing compressor, a dosing system, a softener or as an intermediate component to flush long pipes (screw connections and seals are included in the scope of supply). Adjusting piece 1" 190 mm Order no. 128 001 Adjusting piece 1 1/4" 190 mm Order no. 128 401 Adjusting piece 1 1/2" 330 mm Order no. 128 402 Adjusting piece 2" 330 mm Order no. 128 403 Case with connection fittings 3/4", 1", 1¼", 1½", 2" To connect a flushing compressor to the pipe, e. g. where the existing filter, adjusting piece, water softener or dosing system is located. Connection fittings for 1, 1¼, 1½, 2, e. g. for installation at the location of the adjusting piece (variable installation length, starting from approx. 175 mm), 2 transition pieces with seals for each nominal diameter. Connection fittings for installation at the location of a filter with an installation length of 100 mm, one flushing adapter ¾, 1, 1 ¼ each (fixed installation length, 100 mm). BOXER K fine filter with connection set for installation of the filter at the inlet of the flushing compressor. Connection set for system separator to install an optional system separator DN 25 at the inlet of the flushing compressor. 2 connection angles, 4 spare O- rings. Mounting instructions. Order no. 151 070 Case with connection fittings 1½", 2", DN 65, DN 80 To install two - in case of DN 80 up to three - flushing compressors in parallel in the pipe, e. g. at the location of an existing filter, adjusting piece, water softener or dosing system. Connection fittings for 1 ½, 2, 65, DN 80 (variable installation length, starting from approx. 190 mm), 2 transition pieces resp. transition flanges with seals for each nominal diameter 2 blind caps 6 connection angles, 4 spare O-rings Mounting instructions Order no. 151 080 Hose extension set for flushing compressor and MOBIdos dosing system 2 flexible connection hoses of 1.5 m each 2 coupling pieces 4 spare O-rings packed in cardboard box Order no. 151 820 Dosing system GENODOS DM-SK As accessory to the flushing compressor, for the disinfection of pipes with GENO -Chlor A or GENO -perox. Dosing pump GP 10/40, selfdeaerating, for degassing media, controlled via contact water meter of flushing compressor, power supply 230 V, 50-60 Hz. Dosing line with dosing valve for connection at the flushing compressor. Suction lance with empty signal and pre-alarm, suitable for 10 kg or 20 kg transport canisters. Water test kit for chlorine, 10-160 mg/l (20 analyses). Completely packed in cardboard box. Order no. 160 442 Euro system separator GENO -DK 2, 1 Order no. 132 530 Dosing solutions GENO -Chlor A (25 kg) Order no. 210 012 GENO -perox (1 litre) Order no. 170 320 GENO -perox (10 kg) Order no. 170 325 Water test kits Chlorine 10-160 mg/l (20 analyses) Order no. 170 138 Chlorine 0.1-2.0 mg/l and ph value 6.9-8.2 (150 analyses) Order no. 170 128 Peroxide 100-1,000 mg/l (100 analyses) Order no. 170 167 Peroxide 0.5-25 mg/l (100 analyses) Order no. 170 136 Edition: 26.04.13 We reserve the right to modifications! Page 2 of 5 Supersedes: 17.01.13 Edited by: KONS/gmei-mrie g:\ PDB-F02-INTER_SPÜLKOMPRESSOR_1988K.DOC

Case with closing plugs, 60 closing plugs ½ Case with flushing fittings, 20 flushing fittings with accessories Flushing water relief tank Closing plugs for implementation at withdrawal points, also suitable for leakage tests and to deaerate the drinking water installation. The closing plug can be equipped with an optional flushing fitting (see case with flushing fittings) to perform the flushing. The closing plugs consist of 2 parts, the basic body and screw cap, both parts are made of brass and are coated with stain-resistant plastic. Due to the small diameter of only 35 mm without fins, it is possible to lay the tiles without dismantling the plug and furthermore, only small holes are required in the tiles. 60 closing plugs 20 spare O-rings 1 bag of drying agent Mounting instructions. suitable for Sortimo in-vehicle equipment. Order no. 151 160 Set of closing plugs 20 closing plugs 1/2" in cardboard box incl. 20 spare O-rings Order no. 151 170 In order to use these flushing fittings, the above mentioned closing plugs are needed. See case with closing plugs or set of closing plugs. In order to flush the pipes, the flushing fitting is connected to the closing plug and thus discharges the flushing water to the drain during the flushing of the pipes. Furthermore, it can be used to withdraw construction water, to fill bath and shower tubs and to bridge pipes (to do so, use pressure-resistant hose). The flushing fittings consist of two parts, the ball-type shut-off valve and a removable hose connection, both made of chrome-plated brass. Thanks to the balltype shut-off valve, a large and free cross section for the flushing is available. Due to the removable hose connection, the hose may remain connected to the hose nozzle. As the closing plug and the flushing fitting are two separate entities, only the closing plug remains behind at the construction site for the time between installation and start-up. The flushing fitting on the other hand can be used at several construction sites - just like a tool. Furthermore, the introduction of impurities due to unauthorised access is prevented. 20 flushing fittings 20 hose clamps 1 roll of hose, 15 m Mounting instructions Order no. 151 180 Hose for flushing fittings 50 m roll Order no. 151 648e In the flushing of drinking water installations, the flushing water relief tank ensures the draining of the settled flushing water into a floor drain or a toilet bowl. According to the DVGW worksheet W 557, the withdrawal points must be equipped with corresponding devices to separate the air from the flushing water if the flushing is performed with a water/air mix. Up to 6 flushing hoses for a total of 5 m³/h can be fastened securely at the flushing water relief tank. Thanks to the integrated free outlet, the separation of drinking water installations and the drain is ensured and back- suction is prevented reliably. Furthermore, persons within the perimeter of the withdrawal points are protected from aerosols and the settled water calmly flows to the drain. The discharge of impurities and turbidities can easily be detected in the flushing water. A lower box is included in the scope of supply in case the water is discharged into a into a toilet bowl. This box also serves as transport box for various connection pieces. Flow rate Qmax 5 m³/h Inlet connection 6 x Schlauchtülle13 mm (union nut 3/4") Outlet connection HT-pipe DN 100 Dimensions (without connections) (w x d) 400 x 300 mm Height (with/without lower box) 340/660 mm. Height of outlet connection (with/without lower box) 175/498 mm Order no. 151 020 Edition: 26.04.13 We reserve the right to modifications! Page 3 of 5 Supersedes: 17.01.13 Edited by: KONS/gmei-mrie g:\ PDB-F02-INTER_SPÜLKOMPRESSOR_1988K.DOC

1 Drinking water filter, e. g. BOXER KD (to be provided by others) 4 Dosing system GENODOS DM-SK (accessories) 2 Connection pieces (accessory case with connection fittings ¾ -2 ) 5 System separator GENO -DK 2, 1 (accessories) 3 Dosing solution (accessories) Fig. 2: Installation example GENO -flushing compressor 1988 K Fig. 3: Installation example flushing water relief tank with floor drain Fig. 4: Installation example flushing water relief tank with toilet bowl Edition: 26.04.13 We reserve the right to modifications! Page 4 of 5 Supersedes: 17.01.13 Edited by: KONS/gmei-mrie g:\ PDB-F02-INTER_SPÜLKOMPRESSOR_1988K.DOC

Table technical specifications GENO -flushing compressor 1988 K Connection data Power supply [V]/[Hz] 230/50 Protection/protection class IP 20/I Flushing connections 1" male thread Max. water flow [m³/h] 5 Max. water pressure (recommended) [bar] 7 (4-5) Connection for compressed air Quick-acting coupling connector Nominal pressure PN 10 Performance data Compressor aggregate [bar] 8 (oil-free) Max. power input [kw] 1.5 Operating mode S1 (suitable for continuous operation) Air suction capacity [l/min] 200 Volume of pressure tank [litres] 10 Dimensions and weights A Width of flushing compressor [mm] 390 B Height of flushing compressor [mm] 625 C Depth of flushing compressor [mm] 330 Operating weight without accessories [kg] 21.8 Shipping weight, completely packed [kg] 25.2 General Water temperature [ C] 5-30 Ambient temperature [ C] 5-35 Order no. 151 200 * Water supply provided by others on site Fig. 3: Dimensional drawing of GENO -flushing compressor 1988 K Edition: 26.04.13 We reserve the right to modifications! Page 5 of 5 Supersedes: 17.01.13 Edited by: KONS/gmei-mrie g:\ PDB-F02-INTER_SPÜLKOMPRESSOR_1988K.DOC