Operating Instructions DB41

Similar documents
The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

Instruction Manual SB02, SB03, SB04 All metal flow limiter

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Mass Flow Controller (MFC) for Gases

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

Mass Flow Meter (MFM) for Gases

Mass Flow Controller (MFC) for Gases

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

analytical bulk flow distance FLOW level pressure temperature industrial communication

C-Flow Coriolis Mass Flow Meters

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

deltaflowc deltaflowc Venturi or Probe

Model 601CV. Mass Flow Controller. Product Features:

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Pro-V Multivariable Flowmeter

Mass Flow Meter (MFM) for gases

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Features. Description

SITRANS P measuring instruments for pressure

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SCHMIDT Flow Sensor SS Instructions for Use

780S Ultra High Purity Series

MANUAL KPS Pressure Control Valve

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

Mass Flow Controller (MFC) for Gases

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Flow metering in gases Introduction to COMBIMASS family

Mass Flowmeters. Mass Flowmeters for Gases

Design Features. General Description

Thermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

Model PDT Dewpoint Transmitter

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Technical Data Sheet MF010-O-LC

TH-1800-T TRX-700-CNG Converter

Instruction Manual Contact Pressure Vacuum Gauge

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

INSTALLATION & MAINTENANCE INSTRUCTIONS

DTG - LCD Digital Temperature Gauge USER MANUAL

T EK-COR 1100A Coriolis Mass Flowmeter

Mass Flow Controller (MFC) for Gases

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

Precision pressure sensor Basic version Model CPT6020

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Pressure transmitter PASCAL Ci4

better measurement Simply a question of

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

Transmitter CS 21 Operation Manual

SonoMeter 30 Energy Meters

Mass Flow Controller (MFC) for Gases

Ultra High Purity Model 780S

Mass Flow Controllers

Columbus Instruments

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Automatic Isokinetic Sampler. ST5 Evo

Compressed Air Counter testo 6440

Digital Mass Flow Meters and Controllers for Gases

TF- & DM-Series. Turbineflowmeter

For Multi-Parameter Meters see mvx

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Instruction and Maintenance Manual

Instruction Manual Dräger MSI P7 and MSI P7 plus

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

FAS-W. Features. Applications. Automatic condensation hygrometer

OPTIBAR P 1010 C Technical Datasheet

Precision Mass Flow Meters / Controllers for Liquids and Gases

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Integral type Differential pressure flowmeter VNT Series

GasSense NDIR User Manual

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

EPP4 Pressure Regulator Basic G 1/4"

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

2/2-Way Solenoid Control Valve

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

P900. P900, Datenblatt Seite 1 DESCRIPTION

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Self-operated Pressure Regulators for special applications

GA24 Technical Datasheet

VA40 - VA45 Technical Datasheet

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Transcription:

PKP Process Instruments Inc. 10 Brent Drive Hudson, MA 01749 Tel: +1-978-212-0006 Fax: +1-978-568-0060 PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating Instructions DB41 Thermal mass flowmeter and counter for gasses

FUNCTIONS Page Safety instructions 3 Instruments description 4 Installation description 4 Technical data 5 Pulse signals/pulse lengths 6 Measuring ranges 6 Drawing of the instrument/instruments dimensions 7-9 Service information 10 Display functions 11-12 Warranty 13 Ordering data 13 2 V2-02-2008

SAFETY INSTRUCTIONS Please read carefully before starting the device!! Warning: Do not exceed the pressure range of 16 bar! Observe the measuring range of the sensor! Always observe the direction of flow when positioning the sensor! The screwed fixture must be pressure tight. It is absolutely necessary to avoid condensation on the sensor element or water drops in the measuring air as they may cause faulty measuring results. The manufacturer cannot be held liable for any damage which occurs as a result of nonobservance or non-compliance with these instructions. Should the device be tampered with in any manner other than a procedure which is described and specified in the manual, the warranty is cancelled and the manufacturer is exempt from liability. The device is destined exclusively for the described application. We offer no guarantee for the suitability for any other purpose and is not liable for errors which may have slipped into this operation manual. We are also not liable for consequential damage resulting from the delivery, capability or use of this device. We offer you to take back the instruments of the instruments family VA 410 which you would like to dispose of. Adjustments and calibrations should only be carried out by qualified employees from the measurement and control technology branch. 3 V2-02-2008

The DB41 is a compact consumption counter for compressed air and gases. Special features: INSTRUMENTS DESCRIPTION - Optimum accuracy due to compact design - Integrated in- and outlet section - Less flow due to measuring section - Indication of the current value in l/min, m³/h, m³/min, l/s, ft/min, cfm and of the counter in m³ resp. l Programming via SFA software. - Analogue output 4...20 ma scalable - Switching of the units between m³/h, m³/min, ft/min, l/min, l/s, cfm, m/s - Reading out the service data INSTALLATION DESCRIPTON The following table shows the additionally required inlet and outlet sections depending on the existing flow Table of additionally required inlet and outlet sections Flow obstruction in front of the measuring section 2 90 bends on one level 2 90 bends 3-dimensional change of direction Minimum length inlet section (L1) Minimum length outlet section (L2) 20 x D 5 x D 35 x D 5 x D Shut-off valve 45 x D 5 x D The respective minimum values required are indicated here. If it is not possible to observe the stipulated equalising sections, considerable deviations in the measuring results must be expected. 4 V2-02-2008

TECHNICAL DATA Measured variables: Principle of measurement: Sensor: Measuring medium: Operating temperature: Operating pressure: Analogue output: l/min m³/h (standard: DIN 1945, ISO 1217 bei 20 C and 1000 mbar) mass flow rate on request (kg/s, kg/min, kg/h) calorimetric measurement Pt45, Pt1000 air, gases -30... 140 C probe tube -30... 80 C housing up to 16 bar 4... 20 ma (please see table in the following) max. burden < 500 Ohm order no description analogue output DB41.08 VA 410 with integrated 1/4" meas. section 4 20 ma = 0... 90 l/min DB41.15 VA 410 with integrated 1/2" meas. section 4 20 ma = 0 80 m³/h DB41.20 VA 410 with integrated 3/4" meas. section 4 20 ma = 0... 140 m³/h DB41.25 VA 410 with integrated 1" meas. section 4 20 ma = 0... 240 m³/h DB41.40 VA 410 with integrated 1 1/2" meas. section 4 20 ma = 0 400 m³/h Pulse output: 1 pulse per m³ resp. l (see pulse diagram on page 6), Power supply: 12 to 30 VDC smoothed ± 15% Power input: max. 80 ma at 24 VDC Accuracy: ± 3% m. v. ± 2% m. v. (option via 5 point ISO precision calibration) Display: Flow in m³/h (1/2 bis 1 1/2 ), l/min (1/4 ) Counter in m³ (1/2 bis 1 1/2 ), resp. l (1/4 ) Measured values max. 6 digits, counter max. up to 99,999,999 l resp. m³, then drops back to 0 Units: m³/h resp. l/min (standard factory settings) Further units selectable via software: m³/min, l/s, ft/min, cfm Mounting thread: 1/4", 1/2", 3/4", 1", 1 1/2" Material Measuring section: Stainless steel 1,4301 5 V2-02-2008

PULSE SIGNALS/PULSE LENGTHS Pulse output signal indication Pulse output: max. voltage pulse +P = +VB (12.. 30 VDC), active signal max. current I = 10 ma Internal pulse receiver: The numbers of m³ per second are summed up and indicated after one second. Consumption-depending pulse lengths flow [m³/sec] pulse length [msec] max. consumption [m³/min] max. consumption [m³/h] up to 3 120 180 10800 from 3 60 480 28800 from 8 30 960 57600 MEASURING RANGES Flow measuring ranges inner diameter VA 410 inch mm meas. ranges from...to 1/4 8,8 DN 10 0.8... 90 l/min 1/2 16.1 DN 15 0.2 80 m³/h 3/4 21.7 DN 20 0.2... 140 m³/h 1 27.3 DN 25 0.2... 240 m³/h 1 1/2" 41.8 DN 40 1.8 400 m³/h Consumption Standard setting l m³ m³ m³ m³ 6 V2-02-2008

DRAWING OF THE INSTRUMENT/INSTRUMENTS DIMENSIONS Connector plug A Connector plug B DB41 1/4" - Connector plug A - Connector plug B DB41 1/2" 7 V2-02-2008

DRAWING OF THE INSTRUMENT/INSTRUMENTS DIMENSIONS - Connector plug A - Connector plug B DB41 3/4" - Connector plug A - Connector plug B DB41 1" 8 V2-02-2008

DRAWING OF THE INSTRUMENT/INSTRUMENTS DIMENSIONS - Connector plug A - Connector plug B DB41 1 1/2" DB41 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Connector A SDI -VB +VB +I 4 20 ma Connection cable A 0554.0104 (5 m) 0554.0105 (10 m) +P Impuls brown white blue black grey Connector B* NC NC NC NC NC SDI -VB Digital signal (inernal data transfer) Negative supply voltage 0 V * Connector plug B without any function! Just for internal use! +VB Positive supply voltage 12...30 VDC smoothed +I Positive 4...20 ma signal +P Impuls Pulse output +VB see page 7 NC Not connected If no connection cable ( 0553 0104, 0553 0105 ) is ordered the sensor will be supplied with a M12 connector plug. the user can connect the supply and signal cables as indicated in the connection diagram. M12 connector plug Connector plug 9 V2-02-2008

SERVICE INFORMATION Maintenance The sensor head should be checked regularly for dirt and cleaned if necessary. Should dirt, dust or oil accumulate on the sensor element, a deviation will occur in the measuring value. An annual check is recommended. Should the compressed air be heavily soiled this interval must be shortened. Cleaning of the sensor head The sensor head can be cleaned by carefully moving it to and fro in warm water with a small amount of washing-up liquid. Avoid physical intervention on the sensor (e. g. using a sponge or brush). If soiling cannot be removed, service and maintenance must be carried out by the manufacturer. Re-calibration If no customer specifications are given then we recommend to carry out calibration every 12 months. For this purpose the sensor must be sent to the manufacturer. Spare parts and repair For reasons of measuring accuracy spare parts are not available. If parts are faulty they must be sent to the supplier for repair. If the measuring device is used in important company installations we recommend to keep a spare measuring system ready. Calibration certificates Calibration certificates are issued by the manufacturer on request. This is a fee-paying service. Precision is tested with PTB (German National Metrology Institute) volume flow nozzles. 10 V2-02-2008

DISPLAY FUNCTION Up/Down ( ) Enter ( ) Lift the rubber cover on top of the DB41 to access the keys. Normal display function Reset Initialization... After power on, the display will go through an initialisation procedure and will show finally the actual on-line values. 2 Sek. Software: 1.20 Hardware: 1.1 DB41 2 Sek. 3457 m3/h Ex factory the DB41 is programmed to show volume flow and total consumption. Via the configuration menu up to 3 channels can be configured for on-line display. The DB41 will toggle between the channels every 2 seconds 11 V2-02-2008

DISPLAY FUNCTION Configuration setting The DB41 is usually configured ex factory according to the customer settings ordered. In case settings have to be changed, the user has to keep the Enter key ( ) pressed while powering up the device. IS DS 300 connected? Yes / No Enter Yes if there is a DS 300 connected to the DB41, otherwise "No". Confirm setting with Enter key ( ). Display 1 Volume flow The DB41 can display up to 3 channels, which are volumetric flow or mass flow, velocity and total consumption. Use the Up/down key ( ) to select the desired channel. If no further channel is wanted, please select nothing. The channels are toggled during normal operation mode very 2 seconds. Consumption 3457 In this step the total consumption counter can be reset to zero. Contrast setting Up change Enter OK Display contrast can be adjusted. Save changes No Yes Press Enter key ( ) to confirm the setting changes or press Up/down key ( ) to discard all changes. 12 V2-02-2008

WARRANTY If you have reason for complaint we will of course repair any faults free of charge if it can be proven that they are manufacturing faults. The fault should be reported immediately after it has been found and within the warranty time guaranteed by us. Excluded from this warranty is damage caused by improper use and non adherence to the instruction manual. The warranty is also cancelled once the instrument has been opened - as far as this has not been mentioned in the instruction manual for maintenance purposes - or if the serial number in the instrument has been changed, damaged or removed. The warranty time for the DB41 is 12 months. If no other definitions are given the accessory parts have a warranty time of 6 months. Warranty services do not extend the warranty time. If in addition to the warranty service necessary repairs, adjustments or similar are carried out the warranty services are free of charge but there is a charge for other services such as transport and packaging costs. Other claims, especially those for damage occurring outside the instrument, are not included unless responsibility is legally binding. After sales service after the warranty time has elapsed We are of course there for you even after the warranty time has elapsed. In case of malfunctions please send us the instrument with a short-form description of the fault. Please do not forget to indicate your telephone number so that we can call you in case of any questions. ORDERING DATA Order no. DB41.08 DB41.15 DB41.20 DB41.25 DB41.40 DB41-Z.L5 DB41-Z.L10 DB41.xx.K Description DB41 consumption counter with integrated 1/4" measuring section DB41 consumption counter with integrated 1/2" measuring section DB41 consumption counter with integrated 3/4" measuring section DB41 consumption counter with integrated 1" measuring section DB41 consumption counter with integrated 1 1/2" measuring section Connection cable, 5 m, with M12 plug Connection cable, 10 m, with M12 plug 5 point precision calibration DB41-Z.N Mains adapter in wall housing 230 VAC/24 VDC 13 V2-02-2008

Flow Metering and Monitoring Systems DB41 Compact thermal mass flow meter and counter for compressed air and non-aggressive gases integrated upstream and downstream pipe runs for high levels of accuracy available for ¼" to 1 ½" pipe sizes measuring ranges: 0.8 90 Nl/min to 1.8 400 Nm³/h local LCD display for flow rate and total output signals: 4 to 20 ma for flow rate, pulses for totalization Description: Model DB41 thermal mass flow meters and counters report and measure mass flow rates and totals of non-aggressive gases, regardless of gas pressure and temperature. Process gas flows around a heated temperature sensor that is encapsulated in glass. As a result, the sensor dissipates heat which an electronics module returns to the sensor to maintain it at a constant temperature. The dissipated heat energy is proportional to the mass flow rate of the gas and is displayed by the electronic analyzer utilizing calibration curves and process parameters stored in the instrument. A 4 to 20 ma signal outputs the flow rate to secondary evaluation devices and a pulse output with a predefined pulse value provides a totalizing function. High levels of accuracy are obtained by means of upstream and downstream pipe runs integrated in the instrument which ensure that the flow stream is laminar. Typical Applications: Series DB41 thermal mass flow meters and counters provide flow measurement of non-aggressive gases in ¼" to 1 ½" pipe systems. Their rugged, heavy-duty design and easy handling and operation make them the right choice for measuring and monitoring compressed air consumption. They also provide measurements of other suitable gases such as: nitrogen oxygen, argon, helium and carbon dioxide. PKP Process Instruments Inc. 10 Brent Drive Hudson, MA 01749 S +1-978-212-0006 T +1-978-568-0060 Email: info@pkp.eu Internet: www.pkp.eu PKP Prozessmesstechnik GmbH Borsigstraße 24 D-65205 Wiesbaden S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50 Email: info@pkp.de Internet: www.pkp.de 6/09

Models: DB41 : Thermal mass flow meters and counters for gases with integrated upstream and downstream pipe runs made of stainless steel 1.4301 Ordering Code: Order Number: DB41. G. 15. L. 0 Thermal mass flow meters and counters for gases with integral upstream and downstream pipe runs Measuring ranges: Process connection (G or NPT) ¼" ½" ¾" 1" 1 ½" Dimensions: Pipe ID (mm) 8.8 16.1 21.7 27.3 41.8 Measuring range 0.8 to 90 Nl/min 0.2 to 80 Nm 3 /h 0.2 to 140 Nm 3 /h 0.2 to 240 Nm 3 /h 1.8 to 400 Nm 3 /h Length of device pipe section (mm) 194 324 439 549 839 Model: G = G male thread N = NPT male thread Measuring range and pipe size: 08 = 0.8 to 90 Nl/min, 1/4 15 = 0.2 to 80 Nm³/h, 1/2 20 = 0.2 to 140 Nm³/h, 3/4 25 = 0.2 to 240 Nm³/h, 1 40 = 1.8 to 400 Nm³/h, 1 ½ Process gas: L = air N = nitrogen A = argon H = helium C = carbon dioxide S = oxygen Options: 0 = none 9 = please specify in writing Accessories : DB41-Z.L5 DB41-Z.L10 DB41-Z.N1 DB41-Z.N2 DB41-Z.K5 5 m cable with matching plug 10 m cable with matching plug Wall mounted power supply, 100-240 VAC, 10 VA on 24 VDC, 0.35 A plug-in power supply, 100-240 VAC on 24 VDC, 0.35 A, with 2 m cable factory calibration, 5 measuring points Pipe size (D) 1/4" 1/2" 3/4" 1" 1 ½" Technical Specifications: Height (H) (mm) Electrical Connection: 129 136 143 151 171 max. pressure: 16 bar Process gas temperature: -30 to +80 C Measurement ± 3% of measured value uncertainty: (± 2% with factory calibration) Measuring ranges and nominal sizes: refer to Ordering Code section Mounting position: any Voltage supply: 24 VDC Outputs : 4 to 20 ma (max. load 500 ohm), pulses (1 pulse/l for DB41...08 or 1 pulse/m³ for DB41...15 to 40, other pulse values available on request) Display : LCD, for flow rate and total (Nl/min for DB41...08 or Nm³/h for DB41...15 to 40, other units available on request) Electrical protection: IP65 PKP Prozessmesstechnik GmbH Borsigstraße 24 D-65205 Wiesbaden S +49 (0) 6122-7055-0 T +49 (0) 6122-7055-50 Email: info@pkp.de Internet: www.pkp.de PKP Process Instruments Inc. 10 Brent Drive Hudson, MA 01749 S +1-978-212-0006 T +1-978-568-0060 Email: info@pkp.eu Internet: www.pkp.eu