London Underground - Section 12 approved Switch Disconnectors

Similar documents
ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

SAFETY QUALITY TECHNOLOGY. Guidance on Safe Isolation Procedures

CMC Series Moulded Case Circuit Breaker Cielo Electric

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Circuit breakers PR 60

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

CATALOGUE EXTRACT SIRCO PV. Disconnect switches for photovoltaic applications From 100 to 2000 A, up to 1500 VDC UL 98B & IEC

Differential pressure controls, Type MP 54, 55 and 55A

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

PSSI 3 High Voltage Metal-Enclosed Switchgear

OTL Universal terminals

Pressure switch KP-E. Data sheet

NEW TYPE M PRESSURE RELIEF DEVICE

Meta-MEC Manual Motor Starters

Position switches FP series

Protection of motor circuits

enclosed product catalogue 2010 isolating switches main/emergency off switches changeover switches insulated stainless steel mild steel

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Manual Power relay SR853

EU Declaration of Conformity

Installation, use and maintenance instructions. Gas burner (5)

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Prewired position switches FA series

Electromechanical pressure switches

Electromechanical pressure switches

ServicePlus S21R & S27R Series 2 Installation Instructions

EU Declaration of Conformity

Inspection Recommendations

SM6. instructions for use. connection with compartment for incoming cable from the top. MV distribution factory built assemblies at your service

Isolation of power supplies

Pressure switches for air and water CS

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

Alhambra Arabic design, British engineering

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

GAS INSULATED SWITCHGEAR

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

VERTICAL AIR COMPRESSORS

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

VERTICAL AIR COMPRESSORS

INSTRUCTION MANUAL Pressure Relief Device LPT

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

MaxSB - Low Voltage Switchboard

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

Prewired position switches FA series

Pneumatic valve islands

Arran LED Floodlight Luminaire

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

TeSys protection components

In Ground Buried Uplights

IECEx Certificate of Conformity Annexe

MSA Latchways Ladder System

Zelio Relays RSL Slim Interface Plug-In Relays

Selection of Electrical PPE Tables

Pneumatic spool valve islands

Technical Specification for Pole Mounted Three (3) Phase Gas Insulated Load Break Switches

Types and approvals. Page 1/6. Data Sheet

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

CALEFFI. Ball zone valves. series /03 GB

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

Pressure controls for hydro carbons, zone II applications, Type KPE

(1) Warranty Certificate 01. (2) About the use of Traction Machine 03. (3) General Instructions 03. EMC Directive 03. Copy Right Low 03.

EU Declaration of Conformity

EX-RECESSED CEILING LIGHT FITTINGS

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers.

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Actuating elements for ComEx

Pressure Switches Application Guideline

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X

DX 3 RCDs. Technical data Nature and consequences of electrical risks Direct and indirect contact. Direct contacts

TECHNICAL CHARACTERSTICS

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Operating Instructions

Operating Instructions

PERIODIC INSPECTION REPORT FOR AN ELECTRICAL INSTALLATION

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Operating Instructions

Installation. S&C Vista Underground Distribution Switchgear. UnderCover, Vault-Mounted, and Pad-Mounted Styles. Instruction Sheet

Appendix A: Energized Work Permit

CFSW. Hinges with built-in safety multiple switch

C I R E D 18 th International Conference on Electricity Distribution Turin, 6 th to 9 th June 2005

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

RP series Rotor Pumps

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES

Installation & Operation Manual Proven Quality since 1892

Low Voltage Electricity System Safety Rules & Associated Safety Guidance

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Junction Boxes Series 8118

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

Transcription:

Introduction Following the Kings Cross fire of 1987, the resulting Fennell enquiry prompted the introduction of additional fire precautions for Sub-surface Railway Stations. These additional requirements were introduced under section 12 of the Fire Precautions Act 1971, and since then have been known simply as Section 12 regs. The forensic report on the fire sited several instances of a flash over effect caused by materials and paint finishes being ignitable. Exacerbating the conditions underground were toxic fumes given off by certain materials being excessively heated. Although the new regulations dealt with all aspects of fire prevention such as the removal of wooden escalators, the installation of heat detectors, improved staff training etc, as far as actual equipment supplied for underground use, the overriding emphasis was on materials and paint finishes. With this isolation range, the overall consideration has been to meet, and where possible exceed, the Section 12 requirements. This has been achieved by the careful selection of individual component materials and the use of only recognised and approved paint finishes. Applicable Regulations/Specifications Section 12 of the Fire Precautions Act 1971 The Fire Precautions (Sub-surface Railway Stations) Regulations 2009 BS EN 60947-3 Low voltage switchgear and controlgear. Switches, disconnectors, switch-disconnectors and fuse-combination units. BS HD 60269-2:2013, BS88-2:2013 Low Voltage Fuses. Equipment Switch disconnector assemblies in the range 40A - 400A are all supplied housed in one of five sizes of sheet steel enclosures. The interior assemblies are all supplied in three pole + switched neutral form. The all metal operating handles are supplied in two sizes across the range, and are lockable in the Off position as standard, with an option to enable locking in the On position. The IP65 sealed enclosures are generously proportioned to allow simple cable connection, with removable gland plates on both top and bottom faces. All external surfaces are finished with a 3M ScotchKote EA9WB approved paint system. Enclosures are finished red or grey and handle assemblies red. The Castell lock option and its operation is shown in detail in appendix A. The lock code must be advised and one key is supplied as standard with each unit. Catalogue Numbers Catalogue Number BS EN 60947-3 Low -voltage switchgear. BS EN 60529 Degrees of protection provided by enclosures (IP code) Catalogue Number (With Castell Lock) Rating Finished Grey Finished Red Finished Grey Finished Red Enclosure Size* 40A DCG0403LUL DCR0403LUL DCG0403LUL/CL DCR0403LUL/CL 1 63A DCG0633LUL DCR0633LUL DCG0633LUL/CL DCR0633LUL/CL 1 80A DCG0803LUL DCR0803LUL DCG0803LUL/CL DCR0803LUL/CL 2 100A DCG1003LUL DCR1003LUL DCG1003LUL/CL DCR1003LUL/CL 2 125A DCG1253LUL DCR1253LUL DCG1253LUL/CL DCR1253LUL/CL 2A 160A DCG1603LUL DCR1603LUL DCG1603LUL/CL DCR1603LUL/CL 2A 200A DCG2003LUL DCR2003LUL DCG2003LUL/CL DCR2003LUL/CL 3 250A DCG2503LUL DCR2503LUL DCG2503LUL/CL DCR2503LUL/CL 3 315A DCG3153LUL DCR3153LUL DCG3153LUL/CL DCR3153LUL/CL 4 400A DCG4003LUL DCR4003LUL DCG4003LUL/CL DCR4003LUL/CL 4 London Underground Standards:- 1-085 Fire Safety Performance of Materials. S1913 Common and General Requirements for Fixed Installation Power Supply Equipment. Approval :- Product Registration Certificate No. 3062 (26th Feb 2015) Status - Authorised for use. (See page 6) Typical Assembly with a Castell lock *See page 2 To call for padlocking in both Off & On positions, add suffix 10 to the catalogue numbers as shown above. - e.g. DCG2003LUL10 Typical Assembly with a grey Copon finished enclosure Interior assembly (100A) Page 1 e: sales@

Technical Specification (To BS EN 60947-3) Application Sym. Unit Category Rating (A) 40 63 80 100 125 160 200 250 315 400 Rated thermal current I th A 40 63 80 100 125 160 200 250 315 400 Rated Insulation voltage U i V 690 690 690 690 800 800 800 800 1000 1000 Rated impulse voltage U imp kv 6.0 6.0 6.0 6.0 8.0 8.0 8.0 8.0 12.0 12.0 Rated operational current (AC) I e A Rated operational power (Frequent operation) Fuse protected short-circuit characteristics Overload capacity Mechanical endurance P e I cw kw ka (rms) 400V - AC22A/AC22B 40/40 63/63 80/80 100/100 125/125 160/160 200/200 250/250 315/315 400/400 400V - AC23A/AC23B 40/40 50/63 80/80 80/100 125/125 160/160 200/200 250/250 315/315 400/400 690V - AC22A/AC22B 32/32 32/32 50/50 50/50 125/125 125/125 125/160 125/160 250/315 250/315 690V - AC23A/AC23B 25/25 25/25 40/40 40/40 63/80 63/80 80/100 100/125 160/200 160/200 3x400V - AC23A 18.5 25 40 40 63 80 100 132 160 220 3x690V - AC23A 22 22 33 33 55 55 75 90 150 150 Prospective shortcircuit current 100 100 100 70 100 100 80 50 100 100 A Associated fuse rating 40 63 80 100 125 160 200 250 315 400 ka (Peak) ka (rms) Rated peak withstand current Rated short time withstand current ( 1S) 12 12 12 12 20 20 30 30 45 45 2.5 2.5 2.5 2.5 7 7 9 9 13 13 Cycles 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 5,000 5,000 - Terminal type Connecting capacity mm 2 Cable section (Min/Max) 4/16 10/16 16/35 25/35 35/50 50/95 70/95 95/150 150/240 185/240 mm Maximum busbar width - - 15 15 25 25 32 32 40 40 Nm Min. Tightening torque 4 4 5 5 9 9 20 20 20 20 Dimensions CASTELL LOCK POSITI Enclosure finished with an approved paint system and sealed to IP65 Page 2 e: sales@

Dimensions Continued Locking system allows several individual padlocks to be inserted in both Off & On positions Page 3 e: sales@

Step 1a Installation Step 1b Installation Interlock Key Key Trapped Castell Lock Appendix A - Castell Interlock Operation Interlock Disc Mounted on Switch Operating Shaft Door Interlocked Handle Assembly Switch Operating Shaft When the unit is supplied the switch disconnector will be in the position, the Castell lock is in the non interlocked position and the key is trapped in the Castell lock. Step 2 Switching On Key Trapped Key Free To open the door of the enclosure for fitting and cabling. The Castell lock key must be turned 90 degrees anti-clockwise which interlocks the Castell lock to the switch mechanism, thus allowing the Castell lock key to be removed and allowing the enclosure door to be opened. Step 3 Locking On Key Free Following fitting, cabling and closing of the enclosure door, the Castell lock key must be reinserted into the Castell lock and turned 90 degress clockwise, this will disengage the interlock from the disc allowing the switch disconnector to be switched to the position. With the switch in the On position, the Castell lock key must be turned 90 degrees anti-clockwise which interlocks the Castell lock to the switch mechanism, thus allowing the Castell lock key to be removed and kept by the responsible person. Page 4 e: sales@

Step 4a Switching Off Step 4b Locking Off Key Trapped Key Free Appendix A - Castell Interlock Operation The responsible person must insert the Castell Lock key and turn 90 degrees clockwise this will disengage the interlock from the switch mechanism allowing the switch disconnector to be switched to the position. Key trapped & interlocking bolt in the withdrawn position To lock the switch the Castell lock key is turned 90 degrees anti-clockwise which interlocks the Castell lock to the switch mechanism, thus allowing the Castell lock key to be removed and kept by the responsible person. Key free & interlocking bolt in the extended position The Castell lock as shown would be mounted on a secure frameword inside the enclosure providing security against tampering. The key barrel protrudes through an aperture in the enclosure lid. Page 5 e: sales@

Page 6 R5