ShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual

Similar documents
200 PSI HIGH-FLOW AIR SOURCE KIT

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

200 PSI FAST-FILL AIR SOURCE KIT

Operation Manual Air Saver Unit ASV5000 Series

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

400C & 450C DUAL PERFORMANCE VALUE PACKS

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

444C DUAL PERFORMANCE VALUE PACK

VERTICAL AIR COMPRESSORS

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

VERTICAL AIR COMPRESSORS

accidents which arise due to non-observance of these instructions and the safety information herein.

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

RAM 4021 Operation Manual

1 DRIVE INDUSTRIAL IMPACT WRENCH

Code AWC20HP Air Compressor

100C Air Compressor Kit

200 PSI COMPRESSORS - MODEL NUMBERS

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

IMPORTANT SAFETY INSTRUCTIONS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Budget Range Operators Handbook

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Yoke Block Instruction Manual

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

AIR INLINE METAL SHEAR

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Service and Repair Manual

User Instruction Manual

Model PSI Compressor with 3-Gallon Air Tank 12VDC

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Installation of Your SprayMaster System

VACUUM REGULATORS CONTENTS

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

OPERATION MANUAL NTF-60 Plus

Hercules Space Saver Sole Press series

Instruction Manual Updated 7/26/2011 Ver. 2.2

COMPRESSOR MANUAL. (888)

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

SOTR Special Operations Tactical Respirator

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

SILENTAIRE TECHNOLOGY

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

OPERATION MANUAL NTF-15

Welcome to the Specialized Medical Services Respiratory training webinar series!

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Yoke Block Instruction Manual

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

USER GUIDE TO POWER ASSISTED BIKES

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

RC 195 Receiver-Controller

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Model 130M Pneumatic Controller

user manual .68 CALIBER ELECTRONIC PAINTBALL MARKER Meets or exceeds ASTM standards.

CART FOR CENTURION 1500+

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Operator s Manual. The Bullet Blender Gold BB24-AU, BB5E-AU

Installation and Use Manual

SILENTAIRE TECHNOLOGY

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

WARNING TABLE OF CONTENTS:

RAM 4021-DPX Operation Manual

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

Squeegee Unit for MRS Multi-Recovery System

O P E R A T O R S M A N U A O P E R A T O R S M A N U A L L

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

TECHNICAL DATA. Q = C v P S

DS05C,D,G Dial Set Pressure Regulating Valves

WARNING. Paintball Pistol. Paintball Pistol

Portable Oil Lube Air Compressors

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

MANUAL BE SERIES Test Benches

User Manual for the Mars Calibration Bench

PC1131 Electric Air Compressor

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

! WARNING! IMPORTANT HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES ! WARNING! IMPORTANT SAFETY INSTRUCTION AND GUIDELINES

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Installation and User Manual

DUAL 444C ONBOARD AIR SYSTEM

4 ANGLE GRINDER MODEL NO: CAT 52 PART

30T A/Manual Hydraulic Shop Press

Hydraulic Punch Drivers

MODEL NUMBER: AS18-2 USER GUIDE

Transcription:

ShellPa Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual To operate the system properly and safely, read the manual before using ShellPa. This system is not a medical device. For RESEARCH USE ONLY Manufactured by:

Table of Contents 1. Introduction...2 2. ShellPa Components..2 3. Component Description.. 4 4. Set Up and Shut Down of Air Compressor and ShellPa.6 5. Operation of ShellPa.12 6. Coating and Seeding Chambers.14 7. Stretch Programs...15 8. Troubleshooting. 16 9. Warranty..17 Safety Precautions In case of misuse of ShellPa, it may lead to a risk of severe injury and/or breakdown of the system. Only use ShellPa with the an air compressor Turn OFF power when not in use Read the entire ShellPa manual before assembling and using the instrument Read the operating manual for JUN-AIR air compressor as well. Only use the designated air pressure. Using other values may lead to damaging the instrument. Keep away from flammable agents Do not touch with wet hands Instrument and air compressor should not be operated in standing water - 1 -

1. Introduction ShellPa was designed to replicate the dynamic cellular environment of the body by applying mechanical strain to cultured cells. Physiological cell response to mechanical stress is a more realistic model than conventional static cell culture. 2.ShellPa Components Main Unit Controller Air compressor (with BMF integrator/mist filter and 2 nd air pressure regulator attached) Intake air filter BMF Integrator/Mist Filter and 2 nd Air Pressure Regulator - 2 -

Red and Blue Air Tubes Black Air Tube with air cock valve White Air Tube (Exhaust tube) with noise suppressor AC Adapter (Model: US301210), AC100-240V 50/60Hz 0.3AOP: DC12V Air cock valve Transformer For air compressor AC Adapter Noise suppressor Plastic Square Dish For seeding cells in stretch chambers and covering chambers in Main Unit Disposable Stretch Chamber, SC4B Plasma treated - 3 -

3. Component Descriptions Main Unit Offset Knob For putting in or taking out Chamber Holder Plastic Square Petri Dish to seed cells in the stretch chambers and cover chambers in Main Unit. Chamber Holder Holds 1-6 stretch chambers Button to open cover Stretch Ratio Adjuster Controller Read out of experimental conditions Control Dial Turn dial to set stretch frequency. Range is 1 cycle/min to 120 cycles/min. The default value is 60 cycles /min. Start/Stop Switch - 4 -

Back panel of Controller Connecting Port for AC Adapter Black Connecting Port Black tubing with air cock valve connects to air compressor Blue & Red Connecting Port Blue & Red tubing connects to Main Unit Power Button White Connecting Port White tubing with noise suppressor JUN-AIR 3-4 MC Air Compressor 2 nd Air Pressure Regulator (gauge and valve) Power Switch BMF Integrator/Mist Filter (5 μ, 1 μ) Connect to Controller via Black tubing with air cock valve 1 st Air Pressure Regulator (gauge and valve) Single Phase 100V 0.15Kw Tank 4L Working Pressure: 0.5MPa Switchback Pressure: 0.7MPa - 5 -

4. Set Up and Shut Down of Air Compressor and ShellPa AT THE POINT OF PURCHASE, THE CHAMBER HOLDER IS LOADED ON THE MAIN UNIT. THE MAIN UNIT MUST BE PRESSURIZED TO UNLOAD THE CHAMBER HOLDER. READ THE ENTIRE USER MANUAL BEFORE USING SHELLPA OR ATTEMPTING TO ASSEMBLE OR DISASSEMBLE THE INSTRUMENT. Set up air compressor: 1. Take off the yellow and black protective cap on the side of the air compressor and replace it with the intake air filter. 2. Screw the BMF Integrator/Mist Filter-2 nd Air Pressure Regulator into the 1 st Air Pressure Regulator. Tighten the adjoining screw. 1 st air pressure regulator valve BMF Integrator/Mist Filter 2nd air pressure regulator valve 3. Make sure all the valves are in the CLOSED position a. First air pressure regulator: turn CLOCKWISE to close b. Second air pressure regulator: pull up knob, turn COUNTER CLOCKWISE to close, push down knob to lock position c. Waste valve: turn CLOCKWISE to close - 6 - Waste value

4. Make sure both drain tubes (thick yellow tube and black tubing) drain into a waste container. The small black tubing may already be connected to a plastic bottle. Waste tubes 5. Check oil level in the Air Compressor. If oil is below the minimum (MIN) level, add SJ-27 oil through the oil inlet Oil inlet 6. THE COMPRESSOR IS MADE FOR 110 VOLTS AND NEEDS A STEP DOWN TRANSFORMER IF USING A 220/240 VOLTS POWER SOURCE. PLUG THE AIR COMPRESSOR INTO AN ELECTRICAL TRANSFORMER. INCLUDED WITH THE TRANSFORMER IS A PLUG ADAPTER. - 7 -

Set up Main Unit and Controller: Depending on the ShellPa model, the location and orientation of the ports (blue, red, white, black) may be different than the image below. For all models, the color of the port corresponds to the color tubing it connects to. Back panel of Controller Back or side panel of Main Unit 1. Use the Blue and Red tubing to connect the Main Unit to the Controller by gently pushing the tubing into the same color port. To release the tube from the port, push in the grey plastic washer surrounding the tubing, then pull out the tubing. 2. Connect the White tubing with the noise suppressor to the White port on the back panel of the Controller. 3. Connect the Black tubing with air cock value to the Controller. The air cock valve should be closer to the Controller and not the air compressor. The air cock valve should be in the CLOSED position (+). Attach the other end of the tubing to the BMJ Integrator/Mist Filter on the air compressor. Air cock valve Side view of BMJ Integrator/Mist Filter Air flow Open Closed Attach Black tubing to BMJ - 8 -

4. Plug the AC Adapter into the Controller. The AC Adapter is made for both 110 and 240 volts therefore no transformer is needed. Plug the transformer (with air compressor) and AC Adapter into a 240 volt power source. Turn ON Air Compressor and ShellPa: CAUTION: This system is pneumatic. The misuse of the system may lead to a risk of breakdown. Incomplete connections may cause an air leakage. Be sure to confirm the proper connections before operating the system. 1. Turn ON Air Compressor Power Switch. The green light next to intake air filter will illuminate. 2. OPEN the valve of 1 st regulator by turning the valve COUNTER CLOCKWISE. The pressure will build to 7 Bar on the regulator. When the pressure reaches 7 Bar, the compressor will automatically turn off and the green light will also turn off. a. The regulator will indicate pressure regardless of the valve being open or closed. Therefore the measurement of pressure in the regulator is not necessarily an indication that the valve is open. 1 st regulator at 7 Bar - 9 -

3. OPEN the 2 nd regulator by lifting the knob up then turning it CLOCKWISE. Continue to turn the knob until the regulator reaches 3-4 Bars. 4. Once 2 nd regulator reaches the desired pressure, lock the position by pushing down on the knob. 2 nd regulator at 3 Bar 5. OPEN air cock valve (-) on black tubing leading to Controller. This will pressurize the ShellPa. 6. When the air pressure in the 1 st regulator lowers to 5 Bar, the compressor will automatically turn on until it pressurizes to 7 Bar, then the compressor will turn off. 7. Turn ON the Controller using the toggle switch on the back panel. 8. Turn the knob on the Controller to adjust frequency. Press the START/STOP button to start or stop a run. a. The Controller must read STOP to change the frequency. Default setting is 60 cycles/minute. b. Turning the knob during a Run will change the display. The knob will toggle between current run and total run time. 9. Routine checking of air pressure is highly recommended during operation. 10. Guidelines Valves Open Closed Working Pressure 1 st regulator Counter clockwise Clockwise 7 Bar Lift up, turn Lift up, turn 2 nd regulator Clockwise, Push down Counter clockwise, Push down 3 4 Bar* Air cock valve Counter clockwise Clockwise - Waste valve yellow tube Counter clockwise Clockwise - *2 nd Regulator: DO NOT pressurize over 5 Bar for safe use - 10 -

When operating the Main Unit for long periods of time at frequencies of 60 cycles/minute (1Hz) or faster, lower the pressure to 2 Bar to reduce load on the air compressor Turn OFF Air Compressor and ShellPa: 1. Turn OFF the Controller using the toggle switch 2. CLOSE the air cock valve (+) on the black tubing. 3. Remove the BLACK tubing from the Controller by pushing in the grey plastic washer surrounding the tubing. This will release the tube. 4. CLOSE the 1 st regulator by turning the valve CLOCKWISE 5. OPEN the air cock valve (-) on black tubing to release pressure. Decrease in pressure will be indicated by the 2 nd regulator. 6. CLOSE the 2 nd regulator by lifting up the knob, turn COUNTER CLOCKWISE until it stops turning, push down to lock position. 7. Release pressure from the air compressor tank by OPENING the waste valve. Turn the valve COUNTER CLOCKWISE. Pressure will decrease in 1 st regulator. The air compressor motor may automatically turn on. Leave the motor ON until the fluid collected in the air pressure tank is flushed out the waste tubing. a. The air compressor compresses the atmospheric air and absorbs the moisture in the air that causes the fluid to pool in the tank. A periodical fluid removal from the tank drain and mist filters is required. In case of interfusion of such a fluid into the main unit or/and controller may lead to a risk of breakdown of the system. 8. Once pressure in 1 st regulator reads zero and waste fluid is expelled, turn OFF motor 9. Blot the bottom of the BMJ filters with an adsorbent towel. 10. CLOSE the waste valve by turning CLOCKWISE 11. Unplug the Controller and air compressor from the power source 12. Unplug the tubes (red, blue, white, and black with air cock valve) from the Main Unit, Controller, and air compressor by pushing in the grey washer which will release its grip on the tubing. - 11 -

13. When transporting the air compressor or if not using for extended period of time, replace the intake air filter with the yellow protective cap to prevent oil leakage and dust interfusion. 5. Operation of ShellPa: DISINFECT THE SHELLPA WITH 70% ETHANOL WIPES. ALL SURFACES THAT POTENTIALLY CAN HARBOR CONTAMINANTS SHOULD BE CLEANED PRIOR TO USE. 1. After the ShellPa is properly pressurized, turn the knob on the Controller to adjust frequency from 1 120 cycles/minute. The Controller must read STOP to change the frequency. The default setting is 60 cycles/minute. 2. Press the START/STOP button to start or stop a run. Turning the knob during a Run will change the display to show either time of current run or total time of run. The current time is reset every time the run is STOP. The total time will reset to zero when the power switch on the back panel of the Controller is turned OFF. 3. In the Main Unit, turn the Offset Screw CLOCKWISE to properly align chamber holder with support arms. Depress the Unload levers on each side of the holder, and then lift the chamber holder out of the Main Unit. a. Depending on the ShellPa model, some models need to be pressurized (connected to air compressor) to be able to unload/load the chamber holder from the Main Unit. Pins to hold stretch chambers Offset screw Four holes to align chamber holder with support arms of Main Unit Stretch Ratio Adjuster Four Unload/Load levers - 12 -

4. Place the chamber holder in a sterile biological safety cabinet. Select the desired stretch ratio using the Stretch Ratio Adjuster. Refer to Stretch Programs for details. 5. To load the seeded stretch chambers onto the chamber holder, turn Offset Screw COUNTER CLOCKWISE, to release tension and allow the chambers to easily slide on and off the metal pins. Once 6 chambers are all set, turn the Offset Screw CLOCKWISE to put holding tension on the chambers. 6. Use the plastic square dish (lid or bottom) to protect the chambers. The lid is held in place by the 4 fixed pins toward the bottom edge of the chamber holder. Push the edge of the lid between the 4 pins. 4 fixed pins to hold plastic dish 7. Load the chamber holder back into the Main Unit. - 13 -

8. The entire Main Unit can be placed in a cell culture incubator during use. THE MAIN UNIT CAN BE PLACE IN INCUBATORS WITH TEMPERATURES RANGING FROM 10-40 C AT 95% HUMIDITY. THE CONTROLLER SHOULD REMAIN ON THE OUTSIDE OF THE INCUBATOR IN A DRY, CLEAN ENVIRONMENT. THE AIR COMPRESSOR SHOULD BE OPERATED IN A DRY, CLEAN ENVIRONMENT AND ON A LEVEL AND STRONG PLATFORM (OR FLOOR) 6. Coating and Seeding Chambers 1. Stretch Chambers are disposable and are sold ready to use. They are ethylene oxide gas sterilized. 2. Chambers should be coated with an extracellular matrix, like fibronectin, prior to seeding with cells. Example coating procedure: A. Dilute fibronectin to a final concentration of 2-20μg/mL in Phosphate Buffered Saline (PBS). B. Place the stretch chambers on the square plastic dish and pour fibronectin solution into the stretch chambers so that the bottom of the chamber is covered with fibronectin solution. C. Incubate at 37 C for at least 30 minutes or up to 2 hours. D. Aspirate the fibronectin solution. The chambers are ready to seed with cells. 3. Coated chambers are ready to be seeded with cells. Incubate the seeded chambers overnight. The next day, check cells for attachment to the chamber. 4. Place the chambers into ShellPa. Allow the cells to stretch a few minutes. Check the cells to confirm cell attachment is maintained. - 14 -

7. Stretch Programs Main Unit Stretch Ratio Adjuster % Stretch Distance Lock 0% 0 mm 2 2% 0.4 mm 4 4% 0.8 mm 5 5% 1.0 mm 6 6% 1.2 mm 8 8% 1.6 mm 10 10% 2.0 mm 12 12% 2.4 mm 15 15% 3.0 mm 20 20% 4.0 mm Controller Program Run Stop Default Range Pattern Knob Function Toggles between time of current run and total time Adjust frequency Frequency 60 cycles/minute 1-120 cycles/minute Square - 15 -

8. Trouble Shooting: If system is not stretching, check the following items: All tubings and cables connected Air valve cock open First air pressure regulator valve is open Both the first and second air pressure regulators reading the correct pressure Both the Controller and air compressor are turned on and plugged into an appropriate power source. Power source on Stretch Ratio Adjuster is not in the lock position (0% stretch) - 16 -

Warranty Model No NNMS001 1. The warranty is for one year, commencing the date the customer receives the product and includes the instrument casing, and non-wearable parts. The stretch chambers are considered consumables and are only replaced if received damaged or found defective. 2. The warranty does not cover damage to the instrument that is a result of the following circumstances: 1 Damage caused by dropping, or other impact. 2 Damage caused by inappropriate operation of the instrument. 3 Damage resulting from an attempted repair or modification of the instrument by the user. 4 Damage caused by unavoidable external causes such as earthquakes, lightening, fire, flood, gas leak, power surges, or other acts of providence. 3. is free from any responsibility for effects or loss or damages arising from the result of the machine operation. This warranty assures that will repair our product free of charge as stipulated in our warranty policy. Any shipping charges will be born by buyer. 20813 Stevens Creek Blvd., Suite 200 Cupertino, CA 95014, USA Phone: +1-408-252-6200 Fax: +1-408-252-6220 email: customersupport@b-bridge.com The information contained herein such as specification, configuration, and data or alike in part or in whole may be subject to change without notice. - 17 -