ASTM E1886 and ASTM E1996 TEST REPORT. Report No.: E Rendered to: 3M COMPANY St. Paul, Minnesota 55144

Similar documents
CYCLIC PERFORMANCE PER ASTM E 330 TEST REPORT. Rendered to: TRUSEAL TECHNOLOGIES, LTD. PRODUCT TYPE: Fixed Window

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A STRUCTURAL PERFORMANCE TEST REPORT SUMMARY RENDERED TO:

PERFORMANCE TEST REPORT FOR AIR LEAKAGE AND DURABILITY OF BARRIER PRODUCTS ASTM E Rendered to: BAUTEX SYSTEMS

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: NORTH EAST WINDOWS, USA, INC.

QUANEX BUILDING PRODUCTS TEST REPORT

1688 Jean-Berchmans-Michaud Drummondville, Quebec. J2C 8E9. Mr. Marc-Etienne Mathieu,ing.

LATICRETE International Inc. One LATICRETE Park North Bethany, CT USA

This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or

SECTION BUTTERFLY VALVES

Code Compliance Research Report CCRR-0145

Code Compliance Research Report CCRR-0145

CONTENTS 1. INTRODUCTION DESCRIPTION OF TEST SAMPLE TEST RIG GENERAL ARRANGEMENT TEST SEQUENCE...7

Perma-Shield Gliding Windows (1971 to 1992)

Perma-Shield Gliding Windows

OS2 F R A M E S E R I E S

Test Report. Test Report Smart Systems Limited Incorporating Smart Extrusions. Page 1 of 78

Bomb Blast Mitigation Test

FEATURES. Welded Sash and Main Frame. Swiggle or DuraSeal Spacer System on Fixed Units. 3-1/4" Frame Depth. True Sloped Sill. Integral J Channel

P STYLE 6 LH 5 RH 4 LRH

Intertek Testing Services Building Products. Enterdoor AB ubv

Area of existing house. Gross Flr. area excluding parking. (+1,657 basement) Gross Flr. area inc. covered parking & accessory bldg.

P STYLE 6 LH 5 RH 4 LRH

Technical Report. Title: Product weathertightness testing of a sample of W.G.Ltd 500 series Curtain Walling for The Window Glass Company Limited

Evidence of Performance. Class 4. Class 5A. Class C5 / B5. Test Report No PR01. ift Rosenheim

500 SERIES. Standard-Duty Grade 3 Surface Applied Closers. Standard Features. 3 hours fire rated. door openings. closing speeds

Mott Manufacturing Limited

Beauty-Line Windows (1957 to 1979)

TO THE DRAWINGS AND THE PROJECT MANUAL

SUMMARY STEPS TO CERTIFY ACOUSTIC DUCT SILENCER PERFORMANCE UNDER AMCA INTERNATIONAL S CERTIFIED RATINGS PROGRAM

24 HOUR CUSTOMER SERVICE

P STYLE 6 LH 5 RH 4 LRH

everest efficiency weather tightness durability er tightness durability energy efficiency royalplast.ca

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

FUME CUPBOARD PERFORMANCE CHECK

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

CRL COMMERCIAL PATCH HARDWARE WEDGE LOCK STYLE FOR 5/8"-3/4" GLASS TYPICAL HURCULITE WEDGE-LOCK GLASS DOOR ELEVATIONS P STYLE

BOTTOM HINGED FLOOD BARRIER

Item 404 Driving Piling

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Committee C21 on Ceramic Whitewares and Related Products Subcommittee C21.06 on Ceramic Tile. Research Report C

The following drawings are concerned of this measure, which will be considered in the next revision of the documents as well as in LogiKal.

Product Guide. Latitude Series High-Performance Exterior Metal Wall Panels for Horizontal and Vertical Concealed Clip Application

Kestrel Aluminium Systems Limited. Product Manual Section 10 Thermal Framing System. Manual Version

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Summit Anchor Company, Inc.

400 Series Circle & Oval Windows (1991 to Present)

6.0 ENGINEERING. Build Anything Better. REPRINTED 2017

CE conform applications according to EN Windows without thermal break Systems Forster presto and Forster norm

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot

Originally Issued: 10/08/2010 Revised: 10/27/2017 Valid Through: 10/31/2018

.223 / 5.56 Penetration Tests vs. .40 S&W and 12 ga. Slug

RESIDENTIAL BUILDING PLAN REVIEW CHECKLIST

WITTICH HALL RENOVATION

Taurus 4250 Series Exceptional quality, uncompromising safety TAURUS COLLECTION. The ultimate choice in efficiency, safety and quality

Tests Completed: Test Date(s): Section Results General Requirements (All Protectors) Impact Protector Requirements (Z87+)

Treated w/ mildew and UV inhibitors to keep its beauty through all seasons

Laboratory Report H

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Consult with manufacturers concerning permeation of the pipe walls, jointing materials, valve seats, etc.

l DESCRIPTION l FEATURES l LIMITATIONS l TYPICAL APPLICATIONS l MATERIAL SPECIFICATIONS TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6

INSTALLATION NOTES HURRICANEFABRIC.COM

DIVISION: 06--WOOD AND PLASTICS SECTION: Wood, Plastic and Composite Fastenings

REPORT HOLDER: FRAMECAD LICENSING LTD. POST OFFICE BOX 1292 AUCKLAND 1140 NEW ZEALAND EVALUATION SUBJECT: COLD FORMED STEEL C SHAPES AND TRACKS

GUARD RAIL HEIGHT 42" STANDARD FIN. FLR. 12" MAX ANCHOR SPACING WILL DEPEND ON MOUNTING SUBSTRATE AND REGION OF PROJECT

Water Management Residential Podium Construction BSC Experts Session Overview. Overview

Damage Control/Luminous Shipboard Markings

PFS Test Report TL-109

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

provides an increased stiffness and strength compared with standard cee studs, resulting in lighter headers which require less labor to install.

Standard Recommended Practice. Field Measurement of Surface Profile of Abrasive Blast-Cleaned Steel Surfaces Using a Replica Tape

UPDATE ARLINGTON COUNTY. Bicycle Parking Standards

STANDARD METHOD OF IMPACT TEST AND PERFORMANCE REQUIREMENTS FOR FOOTBALL FACEGUARDS. NOCSAE DOC ND087-17m17c

SafidDampers. Class 1A & Class 1 Low Leakage Volume Control Damper ( Flange Type ) SPK Standard Construction. Description SPK

IAN BENNIE & ASSOCIATES PTY. LTD.

Originally Issued: 10/08/2010 Revised: 10/30/2015 Valid Through: 10/31/2016

Dean Pump Self-Priming Chemical Process Pumps

Architectural Railing Systems

STANDARD PERFORMANCE SPECIFICATION FOR NEWLY MANUFACTURED BASEBALL/SOFTBALL CATCHER S HELMETS WITH FACEGUARD NOCSAE DOC (ND)

STANDARD PERFORMANCE SPECIFICATION FOR NEWLY MANUFACTURED BASEBALL/SOFTBALL CATCHER S HELMETS WITH FACEGUARD. NOCSAE DOC (ND) m14

Mott Manufacturing Limited

Minnesota Park and Sports Turf Managers Association. November 16, 2016

DNVGL-CP-0187 Edition March 2016

REPORT NUMBER: G COQ-004 rev 1 ORIGINAL ISSUE DATE: May 18, 2010 REVISION DATE: June 7, 2010

CTG Certification Protocol -- Version 3.0 SUMMARY

Football Equipment. 5 9/16" Gooseneck Goalposts

Procedia Engineering Procedia Engineering 2 (2010)

AIR VENT HEADS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2008

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

"STEEL FRAMED" ALUMINUM PANEL SHIELDS

Wind action on small sky observatory ScopeDome

ICE PROTECTION - PROPELLER

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

PEAK ALUMINUM FENCING AQUATINE Review for compliance with 2015 International Swimming Pool and Spa Code

ETEM S.A. LIGHT METALS COMPANY 1, IROON POLYTEHNIOU STR. GR MAGOULA ATTIKIS GREECE

HARDWARE. Push / Pulls... A Pivots... A Hinges, Locks and Cylinders... A Handles, Locks and Accessories... A4...

Intertek Testing Services Taiwan Ltd.

PROVIDING QUALITY SOLUTIONS FOR THE AUDIOMETRIC INDUSTRY

PERFORMANCE SPECIFICATION SHEET MICROPHONE ASSEMBLY, M-169A/AIC

2016 GPCOG CULVERT PIPE - BID RESULTS

Transcription:

ASTM E1886 and ASTM E1996 TEST REPORT Report No.: E6587.01 201 44 Rendered to: 3M COMPANY St. Paul, Minnesota 55144 PRODUCT TYPE: Safety and Security Window Film SERIES/MODEL: 3M Safety and Security Film Ultra Prestige with 3M Impact Protection Adhesive Test Date: 08/18/15 Test Record Retention End Date: 11/18/19

Page 1 of 9 1.0 Report Issued To: 3M Company Renewable Energy Division St. Paul, Minnesota 55114 2.0 Test Laboratory: Architectural Testing, Inc., an Intertek company ("Intertek ATI") 849 Western Avenue North St. Paul, Minnesota 55117 651 636 3835 3.0 Project Summary: 3.1 Product Type: Safety and Security Window Film 3.2 Series/Model: 3M Safety and Security Film Ultra Prestige with 3M Impact Protection Adhesive 3.3 Compliance Statement: Results obtained are tested values and were secured by using the designated test methods. The specimens tested met the performance requirements set forth in the referenced test procedures for a ±3360 Pa (±70.0 psf) Design Pressure with missile impacts corresponding to Missile Level A and Wind Zone 4. 3.4 Test Dates: 11/18/15 3.5 Test Record Retention End Date: All test records for this report will be retained until August 18, 2019. 3.6 Test Location: Intertek ATI test facility in St. Paul, Minnesota. 3.7 Test Specimen Source: The test specimens were provided by the client. Representative samples of the test specimens will be retained by Intertek ATI for a minimum of four years from the test completion date. 3.8 Drawing Reference: The test specimen drawings have been reviewed by Intertek ATI and are representative of the test specimens reported herein. Test specimen construction was verified by Intertek ATI per the drawings located in Appendix A. Any deviations are documented herein or on the drawings.

Page 2 of 9 3.0 Project Summary: (Continued) 3.9 List of Official Observers: Name Paul Neumann Eric J. Schoenthaler Company 3M Company Intertek ATI 4.0 Test Specifications: ASTM E1886 05, Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials ASTM E1996 12, Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes 5.0 Test Specimen Description: 5.1 Product Sizes: Overall Area: Width Height 2.2 m² (24.0 ft 2 ) millimeters inches millimeters inches Overall size 1219 48 1829 72 5.2 Frame Construction: Frame Member Material Description All Aluminum Hollow extruded aluminum tube. Joinery Type Detail All corners Butt Secured with a corner key and screws. 5.3 Reinforcement: No reinforcement was utilized. 5.4 Weatherstripping: No weatherstripping was utilized.

Page 3 of 9 5.0 Test Specimen Description: (Continued) 5.5 Glazing: No conclusions of any kind regarding the adequacy or inadequacy of the glass in any glazed test specimen(s) can be made. Glass Type Glazing Glazing Method Ultra Prestige 1/4" tempered glazing laminated with 3M Ultra Prestige Sealed against a vinyl gasket and secured on the interior with a vinyl wedge gasket. The filmed glass was anchored to the interior part of the frame using 3M Impact Protection Adhesive overlapping the frame (reference Drawing ASSY_WINDOW_48x72). Daylight Opening Location Quantity millimeters inches Frame 1 1127 x 1737 44 3/8 x 68 3/8 Glass Bite 13 mm (1/2") 5.6 Drainage: No drainage was utilized. 5.7 Hardware: No hardware was utilized. 6.0 Installation: The specimen was installed into a Spruce Pine Fir wood buck. The rough opening allowed for a 6 mm (1/4") shim space. The exterior perimeter of the window was sealed with sealant. Location Anchor Description Anchor Location Frame perimeter #10 x 3" screws Through the frame 152 mm (6") from each corner and spaced 610 mm (24") on center.

Page 4 of 9 7.0 Test Results: The results are tabulated as follows: ASTM E1886, Small Missile Impact Conditioning Temperature: 24 C (76 F) Missile Weight: 2.0 g Muzzle Distance from Test Specimen: 1.8 m (6' 0") Test Unit #1: Orientation within ±5 of horizontal Impact #1: Missile Velocity: 41.8 m/s (137.1 fps) Impact Area: Upper right glazing corner Impact #2: Missile Velocity: 43.6 m/s (143.0 fps) Impact Area: On the glazing located at the midspan of the left jamb, 275 mm (11") from the left jamb. Impact #3: Missile Velocity: 41.8 m/s (137.1 fps) Impact Area: Lower right glazing corner Test Unit #2: Orientation within ±5 of horizontal Impact #1: Missile Velocity: 41.5 m/s (136.2 fps) Impact Area: Lower left glazing corner Impact #2: Missile Velocity: 42.4 m/s (139.0 fps) Impact Area: Upper left glazing corner

Page 5 of 9 7.0 Test Results: (Continued) ASTM E1886, Small Missile Impact Conditioning Temperature: 24 C (76 F) Missile Weight: 2.0 g Muzzle Distance from Test Specimen: 1.8 m (6' 0") Test Unit #2: (Continued) Impact #3: Missile Velocity: 396 m/s (130.0 fps) Impact Area: On the glazing located at the midspan of the right jamb, 275 mm (11") from the right jamb. Test Unit #3: Orientation within ±5 of horizontal Impact #1: Missile Velocity: 39.9 m/s (130.9 fps) Impact Area: On the glazing located at the midspan of top rail, 275 mm (11") from the top rail Impact #2: Missile Velocity: 40.1 m/s (131.7 fps) Impact Area: Center of glazing Impact #3: Missile Velocity: 43.0 m/s (141.0 fps) Impact Area: On the glazing located at the midspan of the sill, 275 mm (11") from the sill.

Page 6 of 9 7.0 Test Results: (Continued) ASTM E1886, Air Pressure Cycling Test Unit #1 Design Pressure: ±3360 Pa (±70.0 psf) Pressure Range Pa (psf) 675 to 1680 (14.0 to 35.0) 0 to 2105 (0 to 42.0) 1680 to 2685 (35.0 to 56.0) 1010 to 3360 (21.0 to 70.0) Number of Cycles POSITIVE PRESSURE Average Cycle Time (seconds) Observations 3500 1.97 No rips, tears or penetrations. 300 2.50 No rips, tears or penetrations. 600 2.01 No rips, tears or penetrations. 100 2.37 No rips, tears or penetrations. Pressure Range Pa (psf) 1010 to 3360 (21.0 to 70.0) 1680 to 2685 (35.0 to 56.0) 0 to 2105 (0 to 42.0) 675 to 1680 (14.0 to 35.0) Number of Cycles NEGATIVE PRESSURE Average Cycle Time (seconds) Observations 50 2.38 No rips, tears or penetrations. 1050 1.75 No rips, tears or penetrations. 50 2.66 No rips, tears or penetrations. 3350 1.77 No rips, tears or penetrations. Result: Pass

Page 7 of 9 7.0 Test Results: (Continued) ASTM E1886, Air Pressure Cycling Test Unit #2 Design Pressure: ±3360 Pa (±70.0 psf) Pressure Range Pa (psf) 675 to 1680 (14.0 to 35.0) 0 to 2105 (0 to 42.0) 1680 to 2685 (35.0 to 56.0) 1010 to 3360 (21.0 to 70.0) Number of Cycles POSITIVE PRESSURE Average Cycle Time (seconds) Observations 3500 2.72 No rips, tears or penetrations. 300 3.25 No rips, tears or penetrations. 600 2.00 No rips, tears or penetrations. 100 2.66 No rips, tears or penetrations. Pressure Range Pa (psf) 1010 to 3360 (21.0 to 70.0) 1680 to 2685 (35.0 to 56.0) 0 to 2105 (0 to 42.0) 675 to 1680 (14.0 to 35.0) Number of Cycles NEGATIVE PRESSURE Average Cycle Time (seconds) Observations 50 3.03 No rips, tears or penetrations. 1050 2.17 No rips, tears or penetrations. 50 2.65 No rips, tears or penetrations. 3350 2.26 No rips, tears or penetrations. Result: Pass Note: Test Specimens #2 and #3 were cycled in a common chamber.

Page 8 of 9 7.0 Test Results: (Continued) ASTM E1886, Air Pressure Cycling Test Unit #3 Design Pressure: ±3360 Pa (±70.0 psf) Pressure Range Pa (psf) 675 to 1680 (14.0 to 35.0) 0 to 2105 (0 to 42.0) 1680 to 2685 (35.0 to 56.0) 1010 to 3360 (21.0 to 70.0) Number of Cycles POSITIVE PRESSURE Average Cycle Time (seconds) Observations 3500 2.72 No rips, tears or penetrations. 300 3.25 No rips, tears or penetrations. 600 2.00 No rips, tears or penetrations. 100 2.66 No rips, tears or penetrations. Pressure Range Pa (psf) 1010 to 3360 (21.0 to 70.0) 1680 to 2685 (35.0 to 56.0) 0 to 2105 (0 to 42.0) 675 to 1680 (14.0 to 35.0) Number of Cycles NEGATIVE PRESSURE Average Cycle Time (seconds) Observations 50 3.03 No rips, tears or penetrations. 1050 2.17 No rips, tears or penetrations. 50 2.65 No rips, tears or penetrations. 3350 2.26 No rips, tears or penetrations. Result: Pass Note: Test Specimens #2 and #3 were cycled in a common chamber.

Page 9 of 9 General Note: Upon completion of testing, the specimens met the requirements of Section 7 of ASTM E1996. 8.0 Test Equipment: Cannon: Constructed from steel piping utilizing compressed air to propel the missile Missile: 8 mm (5/16") diameter ball bearings Timing Device: Electronic Beam Type Cycling Mechanism: measuring device Computer controlled centrifugal blower with electronic pressure Tape and film were not used to seal against air leakage during structural testing. Intertek ATI will service this report for the entire test record retention period. Test records such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation, will be retained by Intertek ATI for the entire test record retention period. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimens tested. This report may not be reproduced, except in full, without the written approval of Intertek ATI. For INTERTEK ATI: Eric J. Schoenthaler Project Manager Daniel A. Johnson Director Regional Operations EJS/jb Attachments (pages): This report is complete only when all attachments listed are included. Appendix A: Drawings (6) This report produced from controlled document template ATI 00498, revised 06/19/15.

Appendix A Drawings