EXPLOSION - PROOF PRESSURE TRANSMITTER

Similar documents
800 Series. 800 Series INDICATING TEMPERATURE CONTROLS AND THERMOMETERS FEATURES

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

55 Series. 55 Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL FEATURES. Single or Dual 15 A Switch Output. Panel or Surface Mount

J21K Series DIFFERENTIAL PRESSURE SWITCH. features

features Fixed range or field-adjustable 4-20 ma, 1-5 or 0-10 VDC output 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure

10 Series PRESSURE SWITCH. features

55 Series Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL. features. Single or Dual 15 A Switch Output. Panel or Surface Mount

W Series. W Series HIGH PURITY PRESSURE SWITCHES FOR CLEAN GAS APPLICATIONS FEATURES

55 Series Series REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL. features. Single or Dual 15 A Switch Output. Panel or Surface Mount

REMOTE MOUNTING TEMPERATURE SWITCH AND CONTROL

features 4-20 ma, HART 7 communication protocol 0.25% accuracy Compact, 316 stainless steel, hermetically sealed enclosure

Pressure, Vacuum & differential pressure

PRESSURE, VACUUM AND TEMPERATURE

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

120 Series Explosion-Proof Pressure and Differential Pressure Switches

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Part I - Installation

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, TEMPERATURE

PRESSURE, VACUUM AND TEMPERATURE

Part I - Installation

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES

Pressure, Vacuum, Differential Pressure

9700 Transmitter Submersible hydrostatic level transmitter

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Pressure, Vacuum, Differential Pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

High-performance submersible pressure transmitter For level measurement Model LH-10

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

PRESSURE SWITCH. features

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

ASDX Series Silicon Pressure Sensors

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

Electro-Pneumatic Converter YT-940 SERIES

OPTIBAR P 1010 C Technical Datasheet

SITRANS P measuring instruments for pressure

P499 Heavy Duty Pressure Transducer

Pressure, Vacuum, Differential Pressure

EXPLOSION-PROOF PRESSURE, VACUUM,

High-performance submersible pressure transmitter For level measurement Model LH-10

P900. P900, Datenblatt Seite 1 DESCRIPTION

Deep Submersible Level Transducer Series 300DS

Installation and Operation Manual

Instruction Manual for Intrinsically Safe - Reed Switches

EXPLOSION-PROOF PRESSURE, VACUUM, DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES

Pressure Measurement Single-range transmitters for general applications

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

High-performance submersible pressure transmitter For level measurement Model LH-20

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

780S Ultra High Purity Series

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

INSTALLATION & MAINTENANCE INSTRUCTIONS

Wing Union/Hammer Union Pressure Sensors. Datasheet. Models 435/437

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

! Unique Cable Seal System! Fully Temperature Compensated! Datalogger Compatible

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

ellison sensors international

High-performance submersible pressure transmitter For level measurement Model LH-20

T EK-SUB 4800C 19 mm Submersible Level Transmitter

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Pressure Measurement Single-range transmitters for general applications

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Dynisco SPX Industrial (2280/2281) Series

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

DPC-30 DPC-100. Reference Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

PM105 PRESSURE METER USER S MANUAL

American Sensor Technologies. Your Sensor Business Partner...

High-performance submersible pressure transmitter For level measurement Model LH-20

SDX Submersible Depth Transmitter User Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Differential Pressure Transmiter

RoHS. 100 Series. 100 Series. Pressure, Vacuum, Differential Pressure. features. Certified for use in SIL2 functional safety systems.

Technical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?

American Sensor Technologies. Your Sensor Business Partner...

Type S-10, S-11 General Purpose Pressure Transmitters

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Design Features. General Description

ASIC-Based Small Bore Submersible Level Transducer

Precision pressure sensor Basic version Model CPT6020

overview Temperature model (Local, Remote sensing also available) 2 U N I T E D E L E C T R I C C O N T R O L S One Series-B-02

I/P Transducer Positioner Module

User s Guide Temperature Sensor Converter TSC-599

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Level transmitter LT 100

GasSense NDIR User Manual

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

How to specify a product. Process Sensors and Mechanical Instruments

CSA Sample Draw Aspirator Adapter Operator s Manual

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Relative pressure transmitter type 520

EXPLOSION-PROOF PRESSURE, VACUUM, differential PRESSURE and TEMPERATURE SWITCHES

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Transcription:

EXPLOSION - PROOF PRESSURE TRANSMITTER FEATURES Fixed range or field-adjustable Pressure Transmitter 4-20 ma or 1-5 VDC output 0.25% accuracy Compact, 316 Stainless Steel, hermetically sealed enclosure culus & ATEX approved for hazardous locations worldwide Pressure Ranges up to 25,000 psi (1723,7) U N I T E D E L E C T R I C C O N T R O L S T X 2 0 0 - B - 0 1

overview features United Electric s TX200 is a compact, rugged pressure transmitter designed for process control industries worldwide, and ideally suited for petrochemical and offshore platform applications. All welded, 316 stainless steel hermetic construction provides airtight and watertight protection in the harshest environments. A bonded foil strain gage sensor provides reliability and durability. Explosion Proof Enclosure type 4X Welded stainless steel wetted material Submersible to 100 feet Autoclave pressure connection for high pressure applications Non-interactive zero and span adjustment 5:1 pressure range turndown Adjustable version may be calibrated in-place Model TX200A is field adjustable for zero and span using external stainless steel control buttons. Each control button is 316 stainless steel, and magnetically coupled through the hermetically sealed enclosure. For ease of calibration, the transmitter does not require a calibrated pressure source and can be calibrated in-place. Model TX200A span control allows a 5:1 pressure range turndown. Protective Shield. Affixed to the TX200 is a 316 stainless steel, rotatable protective cover, which helps protect product markings, and adjustment buttons (TX200A) from the elements and tampering. Model TX200B is a fixed range transmitter providing a 4-20 ma or (optional) 1-5 VDC signal over the full pressure range. For applications where the process is consistent and field adjustability is not required or desired, model TX200B is a cost-effective transmitter versus other conventional process transmitters. 2 U N I T E D E L E C T R I C C O N T R O L S T X 2 0 0 - B - 0 1

Applications culus and ATEX approvals assure most worldwide hazardous location requirements are met. TX200 pressure transmitters are used to monitor pressures up to 25,000 psi on applications involving: Offshore oil rigs Blow Out Preventors (BOP) Well head monitoring Tubing and casing pressures Gas pipelines, gas flow measurement RTU s and SCADA packages Petroleum refining Rotating equipment Water and wastewater treatment Process monitoring Offshore and Onshore Exploration and Production Instrument Panels Pipelines Refineries TECHNOLOGY Pressure transmitters convert applied pressure to an electronic signal through various technologies. The TX200 pressure transmitter features bonded foil strain gage technology, considered one of the most durable and abuseresistant technologies available. It can be used in ultra high pressure applications and it s durability makes it suitable for applications that experience pressure cycling, shock, and vibration. The bonded foil strain gage measures pressure when a fluid or gas is introduced into a simple low volume chamber (port), where it acts against the diaphragm. Strain gage resistance changes, proportional to the applied pressure, are sensed and conditioned by internal electronics to produce the transmitters output. The output can be specified as either a 4-20 ma or (optional) 1-5 VDC signal. T X 2 0 0 - B - 0 1 U N I T E D E L E C T R I C C O N T R O L S 3

SPECIFICATIONS Performance Full Scale Pressure Range (FSPR): Non-linearity (L): 0 to 100 (0 to 6,9 bar) through 0 to 25,000 psi (0 to 1723,7 bar) 0 to 100 (0 to 6,9 bar) through 0 to 250 psi (0 to 17,2 bar) typical @ 0.2% FSO 0 to 500 (0 to 34,5 bar) through 0 to 25,000 psi (0 to 1723,7 bar) typical @ 0.1% FSO Hysteresis (H) and Repeatability (R): ±0.1% FSO Accuracy (L, H, R): 0.25% Full Scale Output (FSO): 16 ma (4-20 ma) or optional 4 VDC (1-5 VDC) Resolution: Infinite Zero Balance: ± 0.5% (FSO) Temperature Effect on Zero: ±0.5% per 100 F (38 C) Temperature Effect on Span: ±0.5% per 100 F (38 C) Compensated Temperature Range: 0 F to + 176 F (-18 C to 80 C) Operating Temperature: -40 F to 185 F (-40 C to 85 C) per UL, cul -40 F to 176 F (-40 C to 80 C) per ATEX Storage Temperature Range: -65 F to + 250 F (-54 C to 121 C) Electrical Supply Voltage: 10 to 36 VDC for 4-20 ma output 10 to 30 VDC for 1-5 VDC output Output Signal: 4-20 ma or 1-5 VDC (Option M204) Load Impedance: 4-20 ma output: 1300 ohms max. at 36 VDC or 700 ohms max. at 24 VDC 1-5 VDC output: 2000 ohms min. Circuit Protection: The TX200 input is protected against transient surges using both varistor and TVS (transient voltage suppressor) technology, and is reverse polarity protected. Electrical Connection: 1/2 NPT (male), 72 18 AWG, color coded leadwires Wiring: 4-20 ma Output 1-5 VDC Output Red: +VDC +VDC Black: -VDC -VDC Green: Earth Ground Earth Ground Blue: N/A 1-5 V Output Range Adjustment/Calibration (TX200A only) Span Adjustment: Rangeable down 5:1 FSPR Range Calibration Signal: Nominal 20% of FSPR, externally switched Calibration Signal Accuracy: ±1.0% FSO. A calibration certificate with the exact signal to pressure correlation is provided with each unit. Mechanical Pressure Connections: Proof Pressure: Burst Pressure: Enclosure Metals: Wetted Materials: Enclosure Classification: Weight: 1/4 NPT (female), Autoclave Type F-250-C 10,000 psi (689,5 bar) 3 times FSPR; 15,000 psi (1034,2 bar) 2 times FSPR 100 to 2000 psi (6,9 to 137,9 bar) 10 times FSPR; 2500 to 6000 psi (172,4 to 413,7 bar) 8 times FSPR or 30,000 psi, whichever is less; 7500 to 25,000 psi (517,1 to 1723,7 bar) 4 times FSPR or 90,000 whichever is less 316 Stainless steel 316, 15-5 Stainless steel Welded, Hermetically Sealed, Enclosure Type 4X. Certified to IP66 requirements TX200A: 1.5 lbs (.68 kg), TX200B: 1.3 lbs (.59 kg) 4 U N I T E D E L E C T R I C C O N T R O L S T X 2 0 0 - B - 0 1

approvals UNITED STATES AND CANADA Class I, Division 1 & 2, Groups A, B, C & D Class II, Division 1 & 2, Groups E, F & G Class III Class I, Zone 1, Group IIC Enclosure Type 4X UL Listed, cul Certified UL 698, 1203, 61010-1; CSA No. 25, 30, 61010-1 - File # E226592 EUROPE ATEX Directive (94/9 EC) II 2 G EEx d IIC T5, II 2 D T + 90 C Tamb = -40 C to +80 C (-40 F to +176 F) IP 66 EN 50014, 50018, 50281 UL International DEMKO A/S (N.B.# 0539) Certificate #DEMKO 04 ATEX 045830X Pressure Equipment Directive (PED) (97/23/EC) Sound Engineering Practice (SEP) Electromagnetic Compatibility Directive (EMC) (89/336/EEC, 92/31/EEC & 93/68/EEC) UL International EMC Services Certificate File # NC4525 EN 55011, 61000-6-4, 61000-6-2, 61326 pressure model chart Model Pressure Range Proof Pressure** Burst Pressure*** psi bar psi bar psi bar Welded 15-5 stainless steel diaphragm with 316 stainless steel 1/4 NPT (female) pressure connection 06 0-100 0-6,9 300 20,7 1000 68,9 07 0-250 0-17,2 750 51,7 2500 172,4 08 0-500 0-34,5 1500 103,4 5000 344,7 09 0-1000 0-68,9 3000 206,8 10,000 689,5 17 0-1500 0-103,4 4500 310,3 15,000 1034,2 18 0-2000 0-137,9 6000 413,7 20,000 1379,0 10 0-2500 0-172,4 7500 517,1 20,000 1379,0 19 0-3000 0-206,8 9000 620,5 25,000 1723,7 11 0-5000 0-344,7 15,000 1034,2 25,000 1723,7 20 0-6000 0-413,7 18,000 1241,1 30,000 2068,4 12 0-7500 0-517,1 22,500 1551,3 30,000 2068,4 13 0-10,000 0-689,5 30,000 2068,4 40,000 2757,9 14 0-15,000 0-1034,2 30,000 2068,4 60,000 4136,9 Welded 15-5 stainless steel diaphragm with 316 stainless steel Autoclave type F-250-C pressure connection 15 0-20,000 0-1379,0 40,000 2757,9 80,000 5515,8 16 0-25,000 0-1723,7 50,000 3447,4 90,000 6205,3 ** Proof Pressure: The maximum pressure to which a pressure sensor may be occasionally subjected (e.g., start-up, testing), which causes no permanent damage. The unit may require re-calibration if subjected to pressure above proof. ***Burst Pressure: Pressure which may cause failure of the pressure element, resulting in permanent damage. T X 2 0 0 - B - 0 1 U N I T E D E L E C T R I C C O N T R O L S 5

how to order Select letter or number codes to make up part number. PART # TX200 A 09 S 1 M446 Type Enclosure Models, Pressure Pressure Options Range Reference Connection CODE DESCRIPTION ENCLOSURE DESIGNATION A B MODELS, RANGE Field-adjustable Transmitter Fixed range Transmitter 06-20 See model chart for range specifications PRESSURE REFERENCE S psi (sealed gage) PRESSURE CONNECTION 1 1/4 NPT (female); not available on pressure ranges 15-16 (above 15,000 psi) 4 Autoclave Type F-250-C OPTIONS M204 1-5 VDC output; available on TX200B models only M276 Pressure range markings in bar M277 Pressure range markings in kpa M278 Pressure range markings in Kg/cm 2 M423 ATEX flameproof compliant metallic junction box, pre-wired (not UL approved) M444 Paper ID tag M446 Stainless steel ID tag and wire M460 External ground screw; required by ATEX for non-metallic conduit systems M513 UL approved junction box, pre-wired (not approved for ATEX or as Enclosure Type 4X) M550 Oxygen Service Cleaning 6 U N I T E D E L E C T R I C C O N T R O L S T X 2 0 0 - B - 0 1

dimensional drawings FIELD ADJUSTABLE TRANSMITTER (ENCLOSURE A) Pressure Port (A) Model/Range 1/4 NPT (female) 06-14, 17-20 F-250-C Autoclave 06-20 FIXED RANGE TRANSMITTER (ENCLOSURE B) T X 2 0 0 - B - 0 1 U N I T E D E L E C T R I C C O N T R O L S 7

RECOMMENDED PRACTICES AND WARNINGS Company recommends careful consideration of the following factors when specifying and installing UE pressure transmitters. Before installing a unit, the Installation and Maintenance instructions provided with unit must be read and understood. To avoid damaging unit, proof pressure and maximum temperature limits stated in literature and on nameplates must never be exceeded, even by surges in the system. Operation of the unit up to maximum pressure or temperature is acceptable on a limited basis (i.e., start-up, testing) but continuous operation must be restricted to the designated adjustable range. Excessive cycling at maximum pressure or temperature limits could reduce sensor life. A back-up unit is necessary for applications where damage to a primary unit could endanger life, limb or property. A high or low limit switch is necessary for applications where a dangerous runaway condition could result. Install unit where shock, vibration and ambient temperature fluctuations will not damage unit or affect operation. When applicable, orient unit so that moisture does not enter the enclosure via the electrical connection. When appropriate, this entry point should be sealed to prevent moisture entry. Unit must not be altered or modified after shipment. Consult UE if modification is necessary. Monitor operation to observe warning signs of possible damage to unit, such as drift. Check unit immediately. Preventative maintenance and periodic testing is necessary for critical applications where damage could endanger property or personnel. Supply voltage stated in literature and on nameplate must not be exceeded. Overload on a transmitter can cause damage, even on the first cycle. Wire unit according to local and national electrical codes, using wire size recommended in installation sheet. Do not mount unit in ambient temp. exceeding published limits. LIMITED WARRANTY Seller warrants that the product hereby purchased is, upon delivery, free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or material will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); provided, however, that this warranty applies only to equipment found to be so defective within a period of 36 months from the date of manufacture by the Seller. Seller shall not be obligated under this warranty for alleged defects which examination discloses are due to tampering, misuse, neglect, improper storage, and in any case where products are disassembled by anyone other than authorized Seller s representatives. EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. LIMITATION OF SELLER S LIABILITY SELLER S LIABILITY TO BUYER FOR ANY LOSS OR CLAIM, INCLUDING LIABILITY INCURRED IN CONNECTION WITH (I) BREACH OF ANY WARRANTY WHATSOEVER, EXPRESSED OR IMPLIED, (II) A BREACH OF CONTRACT, (III) A NEGLIGENT ACT OR ACTS (OR NEGLIGENT FAILURE TO ACT) COMMITTED BY SELLER, OR (IV) AN ACT FOR WHICH STRICT LIABILITY WILL BE INPUTTED TO SELLER, IS LIMITED TO THE LIMITED WARRANTY OF REPAIR AND/OR REPLACEMENT AS SO STATED IN OUR WARRANTY OF PRODUCT. IN NO EVENT SHALL THE SELLER BE LIABLE FOR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR OTHER DAMAGES OF A LIKE GENERAL NATURE, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS OR PRODUCTION, OR LOSS OR EXPENSES OF ANY NATURE INCURRED BY THE BUYER OR ANY THIRD PARTY. UE specifications subject to change without notice. U.S. SALES OFFICES 32 Highland Rd. South Hampton, NH 03827 Phone: 603-394-0078 FAX: 603-394-0175 28 N. Wise Ave. Freeport, IL 61032 Phone: 815-235-3501 FAX: 815-235-3847 1022 Vineyard Drive Conyers, GA 30013 Phone: 770-483-8400 FAX: 770-929-8716 5829 Grazing Court Mason, OH 45040 Phone: 513-398-3175 FAX: 513-398-3076 102 Salazar Court Clayton, CA 94517 Phone: 925-524-0210 FAX: 925-524-0210 27 Summit Terrace Sparta, NJ 07871 Phone: 973-271-2550 FAX: 973-729-6099 12630 Summerwood Glen Houston, TX 77041 Phone: 832-243-0119 FAX: 832-243-0140 CANADA EASTERN 68 Mosley Crescent Brampton, Ontario Canada L6Y 5C8 Phone: 905-455-5131 FAX: 905-455-5131 U N I T E D E L E C T R I C C O N T R O L S INTERNATIONAL OFFICES 180 Dexter Avenue, P.O. Box 9143 Watertown, MA 02471-9143 USA Telephone: 617 926-1000 Fax: 617 926-2568 http://www.ueonline.com BELGIUM -Europe G. Van Gervenstraat 19A B-9120 Beveren-Waas, Belgium Phone: 32-37554-383 FAX: 32-37552-747 CHINA Room 1114, No. 511 Shenshi Building Weihai Road Shanghai 200041, P.R. China Phone: +8621-6255 8059 FAX: +8621-6255 8349 GERMANY An Der Zentlinde 21 D-64711 Erbach, Germany Phone: 496-062-7400 FAX: 496-062-7501 MALAYSIA, Far East No. 1-2-2, 2nd Floor Jalan 4/101C Cheras Business Centre Batu 5, Jalan Cheras 56100 Kuala Lumpur, Malaysia Phone: 603-9133-4122 FAX: 603-9133-4155 MEXICO Andador Austria 102 Fracc. Petroquimica CP 89365 Tampico, Tamaulipas Mexico Phone: 833-132-3726 FAX: 833-132-3726 RUSSIA, Moscow Kuusinena str., 19A, Office 310 Moscow, 125252, Russia Phone: +7 (095) 792-88-06 FAX: +7 (095) 258-92-12 WESTERN 148 Silver Ridge Close N.W. Calgary, Alberta Canada T3B 3T4 Phone: 403-247-3724 FAX: 403-247-3724 FGS2500805