RS(H)20, 25 USER MANUAL

Similar documents
RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

RHPS Series PRV 2 all types of connections User Manual

LRS(H)4 Pressure-Reducing Regulator User Manual

RHPS Series PRV 6 User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Tank Blanketing Pressure Regulators RHPS Series

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

MEGR-1627 Instruction Manual

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Operation Manual Piston Sensed Gas Pressure Regulators

Installation Troubleshooting Maintenance Instructions Installation / Start-up

WW-720. Pressure Reducing Control Valve

MEGR-1912 Instruction Manual

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

WW-720. Pressure Reducing Control Valve

Self Control Valves. User s Manual. Pressure Reducing Type (V182,V82) Pressure Relief Type (V185) Pressure Retaining Type (V186)

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

64 Series Pressure Reducing Regulators

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

1800C and 1800C-HC Series Service Regulators

THE HF-210 SERIES. Operating and Service Manual. Series includes all variants of HF-210/211. Issue A October 2014 *Section 6.

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Service and Repair Manual

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

1200B2 Series Service Regulators. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Model: 43T. Bermad Pressure Relief Valve

Propor tional Re lief Valve s

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

Bermad Pressure Reducing. Model: 42T

Types S100K and S102K Pressure Regulators

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

WW-730. Pressure Sustaining/Relief Control Valve

Models: C62/63/64-A/D

Type CT88 Backpressure Regulator

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Proportional Relief Valves

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

Anderson Greenwood Series 400 Diaphragm Pilot Operated Safety Relief Valves. Installation and Maintenance Instructions for

Operating instruction

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Installation, Operation, and Maintenance Manual

OPERATING AND MAINTENANCE MANUAL

Mooney* FlowMax* Regulator

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Helium-Oxygen Blender

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

Booster Pump PB4-60 Replacement Kits

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Type OS2 Slam-Shut Device

DS05C,D,G Dial Set Pressure Regulating Valves

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Pressure Regulators. Operating Instructions. Instrumentation

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

RG1200 Service and Repair Manual

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

WHEATLEY Series 500 Swing Check Valve

D05T Compact Design Pressure Regulating Valves

Type FL Pressure Reducing Regulators

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

D05 Pressure Regulating Valves

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Smooth Vent Valve XVD. Series

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Model VR6 System. Installation, Operation & Maintenance

VALVES & MEASUREMENT

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Installation Instructions, Pressure Regulator Series

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Smooth Vent Valve. XVD Series

Transcription:

RS(H)20, 25 USER MANUAL Read the complete manual before installing and using the regulator.

WARNING Before removing a regulator from the system for service, you must depressurize system purge the system to remove any residual system media left in the regulator. CONTENTS Introduction... 3 Installation... 4 Operation... 5 Maintenance... 6 Testing... 6 Troubleshooting... 7 2

Introduction Representative drawing of a standard RS20 1 body 13 valve spring 24 springguide 2 springhousing assembly 14 conical spring 25 3 bodyplug 15 26 set spring 5 valve assembly 16 diaphragm 27 setscrew 7 bodyplate 18 28 nut 8 diaphragm plate 19 29 socket head cap screw 9 bottom springguide 20 o-ring 30 ring 10 seat 21 o-ring 11 22 12 retaining ring 23 ball 3

Installation WARNING When installing a Swagelok self-venting regulator, position the vent connection or line away from operating personnel. Operating personnel must protect themselves from exposure to system fluids. CAUTION Do not use the regulators as a shutoff device The preferred mounting position of the regulator is horizontal with the spring housing facing upwards. The standard connection of the RS(H)20 is 1" bspp parallel female. To get a proper sealing across the thread, Swagelok recommends using bonded seal rings. If earthing is required, connect an earth wire under a spring housing bolt. 4

Operation Note: All handle directions are when viewed from above. Outlet and control pressure settings are obtained by adjusting the set screw with a 19 mm open end wrench. To increase the outlet or control pressure, rotate the set screw clockwise. To decrease the outlet or control pressure, rotate the set screw counter-clockwise and vent the downstream side of the regulator. Make the final setting in the direction of increasing pressure to obtain the most accurate set points. Once fluid is flowing through the system, fine tuning may be required. Icing of the regulator at high flow rates or high pressure drops may occur if the gaseous media or atmosphere contains moisture. An auxiliary upstream filter is recommended for use in all but the cleanest of media. Installation of a downstream pressure relief is recommended for regulator and system protection. If the shut-off valve at the outlet side is closed after changing the set pressure, the outlet pressure will rise a little because of the closing force required for bubble-tight closing of the regulator. This phenomenon is usually referred to as the lock-up and does not indicate a problem with the regulator. A decrease in the flow will result in a rise of the outlet pressure. An increase in the flow will result in a fall of the outlet pressure and is usually referred to as the droop. This phenomenon does not indicate a problem with the regulator. A decrease of the inlet pressure will result in a rise of the outlet pressure. An increase of the inlet pressure will result in a fall of the outlet pressure. This phenomenon is usually referred to as the dependency or supply pressure effect and does not indicate a problem with the regulator. CAUTION When using the RSH(F)20, 25 with an inlet pressure higher than 200 bar, a safety valve must be installed in the outlet line, because the outlet pressure may not exceed 200 bar. 5

Maintenance Required tools for maintenance a vice to fasten the regulator pincers to take out the o-rings a pair of tongs for a retaining ring 70 mm (RS20) a torque wrench a torque wrench hexagon head key 10 mm a torque wrench open end insert tool, 46 mm an open end wrench, 18 mm media and temperature compatible lubricant for reassembling threaded parts media and temperature compatible lubricant for o-rings Snoop liquid leak detector Disassembly instructions Loosen the hexagon socket head screws and remove the spring housing, set spring, bottom springguide. For diaphragm sensing versions the diaphragm and diaphragm plate can be removed. For piston sensing versions, the piston plate and the piston can be removed. Loosen the bodyplug and remove the valve, valve spring and seat. Inspection of disassembled parts Check all parts for abnormal wear. Replace parts in case of doubt. Points of attention before assembly All parts must be clean and undamaged before starting assembly. Swagelok recommends replacing all o-rings and the diaphragm before assembly. All threaded parts must be lightly lubricated before assembly, this to avoid galling of threads. All o-rings need to be lightly lubricated to improve the lifetime of the o-ring and the performance of the regulator. Assembly instructions Follow the points for disassembly in reverse order to assemble the regulator. Recommended torques Hexagon socket head screws M12 80 N m (707 in. lb) Bodyplug 50 N m (442 in. lb) Testing Check the regulator for leakage across the seat, with low- and high inlet pressure. Check the regulator for leakage across the diaphragm/piston, with low- and high outlet pressure. Check the required outlet pressure range. A well performing RS(H)20, 25 is 100% bubble tight. If there is a leakage across the seat or the diaphragm/piston, the damaged parts must be replaced. 6

Troubleshooting The outlet pressure creeps up, without turning the set screw. A damaged valve and/or seat. Replace the valve and/or the seat. Leakage around the bodyplug. A damaged o-ring or insufficient torque on the bodyplug. Replace the o-ring or tighten the bodyplug according to the torque specifications. Leakage between the body and the spring housing or through the relief hole at the side of the spring housing. A damaged diaphragm/piston o-ring or insufficient torque on the bolts. Replace the diaphragm/piston o-ring or tighten the bolts according to the torque specifications. Controlled pressure drops off sharply even when the flow is within regulator capabilities. The system filter element is clogged. Replace the system filter element. The required outlet pressure can not be reached. The inlet pressure is not high enough. Make sure that the inlet pressure is sufficient. The outlet pressure rises too much when going from a dynamic to a static situation. There is too much flow in the dynamic situation. A larger regulator is required. Check the specific application data with the flow curves in our documentation, if available. The outlet pressure does not drop if the set screw is turned counterclockwise. The regulator is non-venting. A shut-off valve in the outlet line must be opened to reduce the outlet pressure. The outlet pressure has changed without turning the set screw. Changes to the inlet pressure will result in changes to the outlet pressure. A decrease of the inlet pressure will result in a rise of the outlet pressure. An increase of the inlet pressure will result in a fall of the outlet pressure. Maintain a constant inlet pressure to the regulator. See section operation about dependency. 7

Warranty Information Swagelok products are backed by The Swagelok Limited Lifetime Warranty. For a copy, visit swagelok.com or contact your authorized Swagelok representative. For additional information, see www.swagelok.com. Caution: Do not mix or interchange parts with those of other manufacturers. Swagelok, Snoop Swagelok Company 2010, 2011 Swagelok Company January 2011, R1 MS-CRD-0189