Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Similar documents
Operating and maintenance manual Filter and reducing station Series / 1.0

Innovative Vacuum-for Automation. Operating instructions SCPSb-2. Eco-Nozzle Technology

Instruction Manual Contact Pressure Vacuum Gauge

Installation and Maintenance Instruction Manual

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Operating Instruction English. Revision A Date author NH This operating instruction is not subject to updating. Airgun

)RU FHUWLILHG FRPSDQLHV ROTEX 509 +HDWLQJ FLUFXLW GLVWULEXWRU 2SHUDWLQJ LQVWUXFWLRQV

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Siphon vessel / Priming aid

OPERATING INSTRUCTIONS

PRAHER PLC-MP AQUASTAR MANAUL 2009

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Installation and Maintenance Instruction Manual

Pressure maintenance valve SDV-P / SDV-P-E

Instructions for Use

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Budget Range Operators Handbook

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

VACUUM REGULATORS CONTENTS

Safety. Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve VMV DANGER. Contents WARNING CAUTION

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

REMS Swing INSTRUCTION MANUAL SINGLE-HAND TUBE BENDER SWING ANCRA

2 Sentry MCL Installation, Operation & Maintenance

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Operating instructions Way valve DR4

Instructions for SILEX 1C Mixed bed cartridge filter

Operating manual for Material pressure tanks Vol./1 and Vol./2

VERTICAL AIR COMPRESSORS

Type 4708 Supply Pressure Regulator

Flowmeter. Original operating manual DFM

Installation and Operating Instructions Bypass Flow Meter DST

User Manual. Quantos Automated Dosing Liquid Module

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

Gas Pressure Regulator HON 300

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Original. Installation and operating instructions. Safety unit 16569

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

Actuating elements for ComEx

3:1 High Ratio Oil Pump W. Extn. Kit

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Operating manual SV120

Installation and Maintenance Instructions for F5509/F6509 Differential Pressure Gauges

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Series IRV1000/2000/3000

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Interface Devices, Inc. Hydraulic Mini Mule

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

MonoControl CS. Operating instructions To be kept in the vehicle! Page 2

Instruction Manual EMA 84 Digital Pressure Gauge

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Operating Instructions SKYJET Compact Sub-distributor

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

FMMP. FluidMonitoring Module Pressure. Operating and Maintenance Instructions. English (Translation of original manual) Documentation no.

Waste Oil Extraction Unit

AIR COMPRESSOR MANUAL INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Operating instructions Diaphragm pump MP-520. Article No Original operating instructions. T-Dok-397-EN-Rev.0web

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

SILENTAIRE TECHNOLOGY

INTENDED USE TECHNICAL SPECIFICATIONS

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

User Manual MFCS TM -EZ

Operation Manual ARTICEL SunSun CUF SunSun CUF SunSun CUF-6000

SUPERIOR PERFORMANCE

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

MANUAL. Sesame. Thermoplastic Tank Technologies

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Instruction Manual Contact Pressure Gauge

original operating manual Operating manual TankQuick 100 F2 Translation of the Item-No.:

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

Instruction Manual Differential Pressure Transmitter

Type 4708 Supply Pressure Regulator

CUT OFF TOOL MODEL: CAT113

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

SILENTAIRE TECHNOLOGY

Product Safety Information

Transcription:

Innovative Vacuum for Automation EN Operating Instructions Dust Filter STF P / STF-D P 30.30.01.00059/02 11.2014 www.schmalz.com

Note These operating instructions were written in the German language. This document should be kept in a safe place for future reference. The right to make technical changes is reserved. No responsibility is taken for printing errors or other types of errors. Publisher J. Schmalz GmbH, 11.2014 This document is protected by copyright. J. Schmalz GmbH retains the rights established thereby. Reproduction of the contents, in full or in part, is only permitted within the limits of the legal provisions of copyright law. Any modifications to or abridgments of the document are prohibited without explicit written agreement from J. Schmalz GmbH. Contact J. Schmalz GmbH Aacher Straße 29 D-72293 Glatten Tel. +49 (0)7443 2403-0 Fax +49 (0)7443 2403-259 schmalz@schmalz.de www.schmalz.com Contact information for the Schmalz companies and trading partners, see www.schmalz.com/vertriebsnetz www.schmalz.com

Contents Dust Filter STF P / STF-D P 1 Basic Safety Notes... 4 1.1 Classification of Safety notes... 4 1.2 Warnings... 5 1.3 Signs... 5 1.4 General Safety Notes... 6 1.5 Intended use... 6 1.6 Requirements for the user... 7 2 Product Description... 8 2.1 Versions... 8 2.2 Dust filter with differential pressure monitoring STF-D P... 9 2.2.1 Technical Data differential pressure monitor... 9 2.2.2 Principle of operation... 9 3 Installation and Operation... 11 3.1 General operation instructions...11 3.2 Installation position...11 3.3 Installation in the bracket...11 3.4 Mounting the hoses...12 4 Maintainance... 12 4.1 Removing and cleaning filter inserts...12 4.2 Installing the filter cartridge...13 4.3 Spare and wearing parts...13 4.4 Put out of operation...13 www.schmalz.com

BASIC SAFETY NOTES 1 Basic Safety Notes 1.1 Classification of Safety notes Danger This warning informs the user of a risk that will result in death or serious injury if it is not avoided. DANGER Type and source of the Danger Consequence Remedial action Warning This warning informs the user of a risk that could result in death or serious injury if it is not avoided. WARNING Type and source of the Danger Consequence Remedial action Caution This warning informs the user of a risk that could result injury if it is not avoided. CAUTION Type and source of the Danger Consequence Remedial action Important This warning informs the user of a risk that could result damage to property if it is not avoided. IMPORTANT Type and source of the Danger Consequence Remedial action Notice This symbol is used when important notes and information regarding use of the machine/the system/the device are provided. Information on the use 4 EN www.schmalz.com 30.30.01.00059/02

BASIC SAFETY NOTES 1.2 Warnings Explanation of the warning symbols used in the operating instructions. Warnings Description Warnings Description General warning sign Danger due to flying parts Warning against electric shock Warning to overpressure Warning about dust generation 1.3 Signs Explanation of the mandatory symbols used in the operating instructions. Signs Description Signs Description Wear a mask Use protective glasses Disconnect before servicing or repair 30.30.01.00059/02 www.schmalz.com EN 5

BASIC SAFETY NOTES 1.4 General Safety Notes WARNING Ignoring the general safety guidelines Personal injuries / damage to plants / systems The operating instructions contain important information on using the dust filter. Read the operating instructions thoroughly and keep them for later reference. Do not connect the filter or start operations until after you have read andunderstood the operating instructions fully. Use only the connections, mounting holes and attachment materials that have been provided. Carry out mounting or removal only when the device is in an idle, depressurized state. Only qualified specialist personnel, mechanics and electricians may perform the installation. Qualified specialist personnel are persons who have received technical training and have the knowledge and experience including knowledge of corresponding regulations necessary to enable him or her to recognize possible dangers and implement the appropriate safety measures while performing tasks. The same applies to maintenance! General safety regulations, European standards and VDE guidelines must be observed and complied with. It is not permitted to make changes to system components. Protect the components from damage of any kind. 1.5 Intended use This dust filter is intended solely for filtering mechanical components in air. This device must not be used to filter other media or liquids. The vacuum must not exceed -500 mbar. Overpressure is not permissible. WARNING Transport or through-suction of liquids or bulk material Personal injury and/or damage to property Do not transport or suck through liquids or bulk material CAUTION Pressure can cause closed devices to explode Personal injury and/or damage to property Wear protective glasses 6 EN www.schmalz.com 30.30.01.00059/02

BASIC SAFETY NOTES 1.6 Requirements for the user All personnel working with the product must be familiar with basic mechanical and pneumatic principles as well as the appropriate technical terminology. To ensure safe operation, this work may only be performed by qualified personnel or trained persons working under the supervision of qualified personnel. A qualified employee is defined as an employee who has received technical training and has the knowledge and experience including knowledge of corresponding regulations necessary to enable him or her to recognize possible dangers and implement the appropriate safety measures while performing tasks. Qualified personnel must observe the pertinent industry-specific rules and regulations. 30.30.01.00059/02 www.schmalz.com EN 7

PRODUCT DESCRIPTION 2 Product Description 2.1 Versions The dust filters are available in the basic version STF P and in the version with differential pressure switch STF-D P. STF P STF-D P Pos. Designation 1 Air inlet connection (suction pad) 2 Air outlet connection (vacuum generator) 3 Upper housing section 4 Lower housing section (dust collecting pan) 5 Filter insert 6 Bracket with locking clip 7 Clamp 8 Differential pressure monitor, adjustable 8 EN www.schmalz.com 30.30.01.00059/02

PRODUCT DESCRIPTION 2.2 Dust filter with differential pressure monitoring STF-D P DANGER Electric shock Fatal injury Disconnect the system from the power supply when connecting or setting the differential pressure monitor. Only operate the system when the differential pressure monitor is properly fitted with a protective cap. 8.5 8.3 8.4 8.2 Pos. Designation 8.1 Dust filter STF-D... 8.2 Differential pressure monitor 8.3 Plug in screw union STV 1/8-6/4 8.4 Hose 8.5 Hose 8.1 2.2.1 Technical Data differential pressure monitor Differential pressure range 10 50 mbar Contact arrangement Accuracy 10% Hysteresis 5 mbar Maximum operating pressure Contact switching capacity 100 mbar 250 V AC / 6 A 24 V DC / 1 A Elektrical connections AMP-Flachstecker 6,3 mm x 0,8 mm nach DIN 46244 Approval VDE 0630 2.2.2 Principle of operation The differential-pressure monitor (Pos. 2) continuously measures the pressure drop across the dust filter. This pressure drop increases as the filter becomes dirty. The limit value for the differential pressure can be adjusted with a knurled knob to any desired value between 10 and 50 mbar. When this limit value is exceeded, contact of the differential-pressure monitor is actuated. Thereby, the cleaning of the dust filter can be signaled. 30.30.01.00059/02 www.schmalz.com EN 9

PRODUCT DESCRIPTION Configuration without indicator lamp The switching signal (normally open or normally closed) initiates signal processing provided by the customer. This signal disappears again when the pressure drops below the limit value (for example, after cleaning or replacement of the filter cartridge). Configuration with indicator lamp The differential-pressure monitor switches on the indicator lamp when the pressure drop across the filter exceeds the limit value. The lamp is switched off again when the pressure drops below the limit value (for example, after cleaning or replacement of the filter cartridge). The indicator lamp indicates that the cleaning/replacement of the filter cartridge is recommended. 10 EN www.schmalz.com 30.30.01.00059/02

INSTALLATION AND OPERATION 3 Installation and Operation 3.1 General operation instructions The temperature must be between -40 C and +80 C The filter must be watertight Warm air should not be drawn in The unit must be easily accessible. (checks, cleaning and replacing the filter insert) With the Jumbo hose lifter, holes for mounting the filter are located on the components used for blower attachment. 3.2 Installation position The bracket is attached using 2 screws. The dust filter can be installed vertically or horizontally. When mounting the unit vertically, note that the dust collecting system [4] must be at the bottom Incorrect installation means that the dust filter and vacuum generator are no longer under warranty. 3.3 Installation in the bracket Place the filter in the bracket [6] and turn or slide in to the desired installation position. Close and lock the locking clip When mounting the unit horizontally, make sure that the "Oben / Top" marking is at the top (+/- 15 deviation is permissible) If necessary, remove the lower housing section, turn it and reattach. 30.30.01.00059/02 www.schmalz.com EN 11

MAINTAINANCE 3.4 Mounting the hoses Filter connections are optimised for the inner diameter of the vacuum hoses. Hoses are attached using the SSD hose clamps included in the delivery 4 Maintainance DANGER Damage from vacuum generator that has not been switched off Personal injury Switch the vacuum generator (e.g. blower, pump) off when performing cleaning, maintenance and repair work. Component Task Time of maintenance Filter insert Connection hoses Plastic housing and bracket Clean and check for damage Replace Check for damage and leaks Check for damage and tears According to the operating instructions of the connected devices At least once after 5 cleanings or at least once every 2 years Monthly or after repairs have been conducted Check when performing filter maintenance 4.1 Removing and cleaning filter inserts WARNING Whirling dust particles Damage to eyes and respiratory tract Wear protective glasses Wear respiratory protection Open the housing using the clamp [7]. The dust collecting pan [4] has to be at the bottom. Remove the filter insert [5] from the housing. Do not wash or brush the filter insert, blow it. Make sure that no dust can get into the inside of the filter insert during blowing. For cleaning, attach a compressed-air pistol with an attached pipe, the end of which is bent approx. 90. It must be long enough to reach the bottom of the insert. Inserts must be blown from the inside out using dry pressurised air (max. 5 bar) long enough to prevent dust formation. 12 EN www.schmalz.com 30.30.01.00059/02

MAINTAINANCE 4.2 Installing the filter cartridge Before installation, the clean filter cartridge must be checked for damage to the paper bellows and the rubber gaskets. Damaged filter inserts must not be re-used. In case of doubt, install a new filter insert. Insert the filter insert and close the housing using the clamp [7]. 4.3 Spare and wearing parts We accept liability for this unit pursuant to our General Terms and Conditions of Sale and Delivery. The same applies for spare parts, provided that these are original parts supplied by us. We fully exclude liability for any damages arising from use of spare parts or accessories that are not original parts of accessories. Designation Use Art.-No. Legende Jumbo Filter insert Jumbo hose lifter 11.04.03.10086 W Filter insert 4.5 STF 4.5 10.07.01.00060 W Filter insert 6.0 STF 6.0 10.07.01.00054 W Filter insert 8.0 STF 8.0 10.07.01.00079 W Filter insert 24.0 STF 24.0 10.07.01.00083 W Hose clamp SSD60 STF 4.5 / STF 6.0 10.07.10.00017 S Hose clamp SSD76 STF 8.0 10.07.10.00037 S Hose clamp SSD125 STF 24.0 10.07.10.00052 S Differential pressure monitor STF-D F 21.01.06.00011 S S= Spare part, W= Wearing part 4.4 Put out of operation The system, replaced components or assemblies must be disposed after the exchange or the shut down, according to national guidelines. IMPORTANT Incorrect disposal of the dust filter Environmental damage Disposal according to country-specific guidelines 30.30.01.00059/02 www.schmalz.com EN 13

Welt der Vakuum-Technologie Schmalz Services Global contact Our sales network of local field representatives, international subsidiaries and trade partners ensures quick and competent information and advice in more than 50 countries worldwide. www.schmalz.com/vertriebsnetz Online dokumentation Conveniently download catalogs, operating instructions and CAD data and get comprehensive information about our products and services. www.schmalz.com/dokumentationen How-to videos In short, easy-to-understand videos we explain the comprehensive functions offered by our products. Take a look, it s worth it! www.schmalz.com/gewusst-wie Other services from consulting to training, see www.schmalz.com/services 30.30.01.00059/02 11.2014 J. Schmalz GmbH Aacher Strasse 29 D-72293 Glatten Tel. +49 (0)7443 2403-0 Fax +49 (0)7443 2403-259 schmalz@schmalz.de www.schmalz.com www.schmalz.com