Flow control valves Series RFU - RFO 2/

Similar documents
Coding of banjo flow controllers. Actuation M = Manual S = Screwdriver

F l o w c o n T R o l v a l v E S

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Series MX pressure regulators 3/

SOLENOID VALVES AND PNEUMATIC VALVES

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

SOLENOID VALVES AND PNEUMATIC VALVES

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

Piloted Non-Return Valves

Wide opening parallel grippers Series CGLN

Description Pressure range Connection thread Device Page

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Microregulator 039 1/8-1/4

Precision and Instrument Regulators 1/4" port size

Pressure-Relief Cartridge Valve, Size 4

Pilot Check Valve: Metal Body Type

Bores: ø 10, 16, 20, 25, 32 mm

Panel-mounted valves Series T, Ø 22.5 mm

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

Complementary valves: shuttle, quick exhaust and check valves

EXH. Specifications. Descriptions. Min. working pressure MPa

seriesek Spool valves pilot and solenoid actuated G 1/8 - G 1/4 - G 1/2 DESCRIPTION Spool valves series EK 2.43 MATERIALS TECHNICAL DATA SPARE PARTS

3-Way Pressure-Reducing Cartridge, Size 2 4

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

4/2 way Pneumatic Solenoid Valve

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Bladder Accumulators High pressure

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

Air Operated Hydraulic Pumping Systems to 50,000 psi

Compressed Air Conditioning Catalog Chapter I

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Hand lever valves VHER

Cooler-Bypass Thermostat Valve, Size 16

Spectrotec. Pressure regulators for acetylene

Exhaust air flow control valves

Direct Operated Precision Regulator Modular Style. Standard Specifications

Air Saving Valve. Pressure Valve Flow Valve

filtered air without lubricant. If lubricated air is used, it is recommended to use ISOVG32 oil and to never interrupt lubrication.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Leak free Pipe Rupture Valve for Excavators

Leak-Free Load-Control Valve SAE ½ psi flange

ALUMINIUM TANK AND COMPENSATOR - SERIES 09

Technical Information Cleanfit CUA451

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

VACUUM REGULATORS CONTENTS

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Safety Relief Valve HON 835

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

Safety and Shut-off Block SAF/DSV

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

Pressure regulators Manually operated Fine setting valves. Brochure

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Pressure relief valve, direct operated Type DBD

2-port seat valves PN25 with externally threaded connections

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

Pneumatic valve islands

Self-operated Pressure Regulators for special applications

SPCH/ Blowing block

4MyCycle Mini Bike Pump. Useful Details for Owners regarding Presta & Schrader Configurations

Conductor Bushings Series 8174

Double Stage Low Pressure Regulator JUMBO KOSAN Type 584

FULL FLOW GAS BALL VALVES: LONDON EN 331 APPROVED. GAS BALL VALVES

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

SYSTEM REGULATING VALVES PRESSURE RELIEF VALVE - SRV BRASS & S/STEEL ADJUSTABLE

MEDICAL GAS OUTLETS & PROBES

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

3-Way Safety Block DSV

Leak-Free Load-Control Valve, Size 20

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Directional Valves. Hydraulic Operated Directional Valves

Precision pressure regulators LRP/LRPS

ALF400 to 900, ALT-5/-9

Pressure relief valve, direct operated

Product Sheet Spraymist Unit

Pressure reducing valve, direct operated

09 - Choosing /sizing a cylinder and valve

Pressure regulator for water

Transcription:

CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5 mm; G1/8 = and 3 mm; G1/4 = 4 and 6 mm; G3/8 and G1/ = 7 mm»» Series RFU: unidirectional flow control valves for the speed regulation of a cylinder»» Series RFO: bidirectional flow control valves for the air flow regulation in both directions and for the pressurization or depressurization of a container. The unidirectional flow controllers are equipped with M5, G1/8, G1/4, G3/8 and G1/ ports. G1/8 and G1/4 ports are available with two different types of adjustment (see diagrams), whereas M5, G3/8 and G1/ ports have just one type of adjustment. All models can be panel or wall mounted or they can be mounted on cylinders, as required. To choose the most suitable model, it is recommended to: 1. calculate the quantity of air in Nl/min (see the cylinders tables in the catalogue appendix);. determine the stroke time of the cylinder; 3. check the flow diagrams (see pages /7.0.03 and /7.0.04). GENERAL DATA Construction Valve group Materials Mounting needle-type unidirectional and bidirectional controller AL body - brass needle (not nickel-plated) - NBR seals with screws in the holes of the valve body or panel mounted Threaded ports M5 - G1/8 - G1/4 - G3/8 - G1/ Installation Operating temperature Operating pressure Nominal pressure Nominal flow Nominal diameter Fluid as required 0 C 80 C (with dry air - 0 C) 1 10 bar (for models with M5 - G1/8 - G1/4 ports) 10 bar (for models with G3/8 - G1/ ports) 6 bar see graph M5 = 1,5 - G1/8 = or 3 mm - G1/4 = 4 or 6 mm - G3/8 and G1/ = 7 mm filtered air /7.0.01

> Valves Series RFU - RFO CATALOGUE > Release 8.5 CODING EXAMPLE RF U4 8 RF SERIES: RF U4 FUNCTION: U4 = unidirectional O3 = bidirectional 8 PORTS: 8 = G1/8 4 = G1/4 5 = M5 6 = G3/8 7 = G1/ FLOW RANGE: = ø max 3 = ø 3 max 4 = ø 4 max 6 = ø 6 max 7 = ø 7 max 651 EXAMPLES OF VALVES SERIES RFO - RFU ASSEMBLY ASSEMBLY EXAMPLES /7.0.0

CATALOGUE > Release 8.5 > Valves Series RFU - RFO FLOW DIAGRAMS (1 ) - VALVES SERIES RFU / RFO - M5 PORTS RFU 45-M5: flow from 1 needle type OPEN = 55 Nl/min CLOSED = 41 Nl/min RFO 35-M5 FLOW DIAGRAMS (1 ) - VALVES SERIES RFU / RFO - G1/8 PORTS RFU 48-1/8: flow from 1 needle type OPEN = 149 Nl/min CLOSED = 130,5 Nl/min RFU 483-1/8: flow from 1 needle type OPEN = 180 Nl/min CLOSED = 140 Nl/min RFO 38-1/8 - RFO 383-1/8 /7.0.03

> Valves Series RFU - RFO CATALOGUE > Release 8.5 FLOW DIAGRAMS (1 ) - VALVES SERIES RFU / RFO - G1/4 PORTS RFU 444-1/4: flow from 1 needle type OPEN = 680 Nl/min CLOSED = 534 Nl/min RFU 446-1/4: flow from 1 needle type OPEN = 680 Nl/min CLOSED = 534 Nl/min RFO 344-1/4 - RFO 346-1/4. FLOW DIAGRAMS (1 ) - VALVES SERIES RFU / RFO - G3/8, G1/ PORTS RFU 467-3/8: flow from 1 needle type OPEN = 1700 Nl/min CLOSED = 1700 Nl/min RFU 477-1/: flow from 1 needle type OPEN = 1700 Nl/min CLOSED = 1700 Nl/min RFO 367-3/8 - RFO 377-1/ /7.0.04

CATALOGUE > Release 8.5 > Valves Series RFU - RFO Unidirectional flow control valves Series RFU To regulate the cylinder speed, the discharging chamber air flow has to be controlled. Therefore, it is recommended to connect the valve threaded outlet 1 to the cylinder inlet and the outlet to the valve user port. TABLE NOTE: * knurled ring nut DIMENSIONS Mod. N Ø A B D F G L M1 M M3 M4 T Z S Max SW SW1 SW RFU 45-M5 1,5 M10x1 M5 4, 14 16 6 18,5 13, 7 13, 39 44,5 3 1 14 8 RFU 48-1/8 M1x1 G1/8 4,5 16 1 34 4,5 16,5 8 16,5 46 51 4 14 17 9 RFU 483-1/8 3 M1x1 G1/8 4,5 16 1 34 4,5 16,5 8 16,5 46 51 4 14 17 9 RFU 444-1/4 4 M0x1,5 G1/4 6,5 5 30 5 35 4 1 4 60 69 7 4 14 RFU 446-1/4 6 M0x1,5 G1/4 6,5 5 30 5 35 4 1 4 60 69 7 4 14 RFU 467-3/8 7 M18x1 G3/8 6,5 7 4 56 43 34,5 8 7,5 75 85 8 * RFU 477-1/ 7 M18x1 G1/ 6,5 7 4 56 43 34,5 8 7,5 75 85 8 * Bidirectional flow control valves Series RFO TABLE NOTE: * knurled ring nut DIMENSIONS Mod. N Ø A B D F G L M1 M M3 M4 T Z S Max SW SW1 SW RFO 35-M5 1,5 M10x1 M5 4, 14 16 6 18,5 13, 7 13, 39 44,5 3 1 14 8 RFO 38-1/8 M1x1 G1/8 4, 16 1 34 4,5 16,5 8 16,5 46 51 4 14 17 9 RFO 383-1/8 3 M1x1 G1/8 4,5 16 1 34 4,5 16,5 8 16,5 46 51 4 14 17 9 RFO 344-1/4 4 M0x1,5 G1/4 6,5 5 30 5 35 4 1 4 60 69 7 4 14 RFO 346-1/4 6 M0x1,5 G1/4 6,5 5 30 5 35 4 1 4 60 69 7 4 14 RFO 367-3/8 7 M18x1 G3/8 6,5 7 4 56 43 34,5 8 7,5 75 85 8 * RFO 377-1/ 7 M18x1 G1/ 6,5 7 4 56 43 34,5 8 7,5 75 85 8 * /7.0.05