LDO II AQ 2/2014, Edition 1.5

Similar documents
Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

User Manual Pocket Pro + Multi 1

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Oxygen Measurement Systems High Reliability and Wide Application Coverage

RAM 4021 Operation Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

Norrsken Family Booklet

Accu-Tab Systems 2000 P Series by Axiall Corporation

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

CP10 Sensor Installation and Maintenance Instructions

Fish Farming Water Quality Test Kit

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Royce Interface Level Analyzer and Sensors

Precision pressure sensor Basic version Model CPT6020

4-in-1 Professional Inflator Kit

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

FPD20 Series. Gear wheel flow sensor

Optical Dissolved Oxygen Meter

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

RGC-IR Remote Gas Calibrator for IR400

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

ATS430 turbidity sensor Retractable insertion assembly

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Dissolved Oxygen OPERATING INSTRUCTIONS

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Digital Melting Point Apparatus

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

OPERATION AND INSTRUCTION MANUAL

Modbus Submersible Level Transducer

Accu-Tab Systems 1000 Series by Axiall Corporation

Operator s Manual 701 Test Kit for Static Control Surfaces (Megohmmeter)

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

DTG - LCD Digital Temperature Gauge USER MANUAL

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Optical Dissolved Oxygen Meter

Oxymax COS61/COS61D. Technical Information

INSTALLATION & MAINTENANCE INSTRUCTIONS

OPERATION AND INSTRUCTION MANUAL ROLLER SLING Model: IN106.3FT & IN106.2FT

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

SITRANS P measuring instruments for pressure

All Purpose AP-Series Operation Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

DEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

DK46 - DK800 Supplementary instructions

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Peak Pressure Indicator MSI-3

HI 2314 HI 2315 HI 23151

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Your safety and the safety of others are very important.

RAM Operation Manual

INSTRUCTIONS PARTS LIST

GILMONT ACCUCAL FLOWMETERS

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

ENVIRONMENTAL INSTRUMENTS, LLC

NOVALYNX CORPORATION MODEL BAROMETRIC PRESSURE SENSOR PCB MODEL BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL

Product Manual (Revision C) Original Instructions. Overspeed Dump Valve. Operation Manual

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

SDX Submersible Depth Transmitter User Manual

Instrument Operating Manual

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

! Warning, refer to accompanying documents.

RAM 4021-DPX Operation Manual

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWY100N

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Dissolved Oxygen Sensor

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

with O 2 Controller Instruction Manual

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S

User s Guide Temperature Sensor Converter TSC-599

INSTRUCTIONS. VP-100 Ion Pump. Model / R001

RDO Optical Dissolved Oxygen Sensor

Pressure Automated Calibration Equipment

USER'S GUIDE. Vaisala CARBOCAP Carbon Dioxide Calibrator for the GMP220 series probes GM K220 U421EN-1.1

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

Installation and Maintenance Instruction Manual

OWNER S MANUAL NMB SERIES

Transcription:

9623800 LDO II AQ 2/2014, Edition 1.5 USER MANUAL

Table of Contents Specifications on page 2 General information on page 3 Product overview on page 4 Installation on page 5 Operation on page 7 Maintenance on page 8 Replacement parts and accessories on page 9 Specifications Specifications are subject to change without notice. Specification Wetted materials (probe body) Details CPVC, sensor end and cable end Polyurethane, over-molding on cable end and cable jacket 316 stainless steel body and screws Viton, O-ring Noryl, nut on the cable end IP classification Wetted materials (sensor cap) Measurement range (dissolved oxygen) IP68 Acrylic 0 to 20 ppm (0 to 20 mg/l) 0 to 200% saturation Measurement accuracy (dissolved oxygen) Below 5 ppm: ± 0.1 ppm Above 5 ppm: ± 0.2 ppm Repeatability (dissolved oxygen) Response time (dissolved oxygen) 0.1 ppm (mg/l) T 90 <40 seconds T 95 <60 seconds Resolution, sensor (dissolved oxygen) Measurement range (temperature) Measurement accuracy (temperature) 0.01 ppm (mg/l); 0.1% saturation. 0 to 50 C (32 to 122 F) ± 0.2 C (± 0.36 F) Interferences No interferences from the following: H 2 S, ph, K +, Na +, Mg 2+, Ca 2+, NH 4 +, Al 3+, Pb 2+, Cd 2+, Zn 2+, Cr (total), Fe 2+, Fe 3+, Mn 2+, Cu 2+, Ni 2+, Co 2+, CN, NO 3, SO 4 2, S 2, PO 4 3, Cl, Anion Active Tensides, Crude Oils, Cl 2 < 4 ppm Storage temperature Maximum ambient temperature 20 to 70 C ( 4 to 158 F) 60 C (140 F). Suitable for use in water up to 50 C (122 F) Minimum flow rate Not required English 2

Specification Sensor cable Details 10 m (30 ft) integral cable with quick disconnect plug (all sensor types) Probe weight 1.0 kg (2 lb, 3 oz) Probe dimensions Diameter x length: 49.3 x 255.7 mm (1.9 x 10.1 in.) Power requirements Warranty 12 VDC, 0.25 A, 3 W Probe: 3 years against manufacturing defects Sensor cap: 2 years against manufacturing defects General information In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential damages resulting from any defect or omission in this manual. The manufacturer reserves the right to make changes in this manual and the products it describes at any time, without notice or obligation. Revised editions are found on the manufacturer s website. Safety information N O T I C E The manufacturer is not responsible for any damages due to misapplication or misuse of this product including, without limitation, direct, incidental and consequential damages, and disclaims such damages to the full extent permitted under applicable law. The user is solely responsible to identify critical application risks and install appropriate mechanisms to protect processes during a possible equipment malfunction. Please read this entire manual before unpacking, setting up or operating this equipment. Pay attention to all danger and caution statements. Failure to do so could result in serious injury to the operator or damage to the equipment. Make sure that the protection provided by this equipment is not impaired. Do not use or install this equipment in any manner other than that specified in this manual. Use of hazard information Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury. W A R N I N G Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or serious injury. C A U T I O N Indicates a potentially hazardous situation that may result in minor or moderate injury. 3 English

N O T I C E Indicates a situation which, if not avoided, may cause damage to the instrument. Information that requires special emphasis. Precautionary labels Read all labels and tags attached to the instrument. Personal injury or damage to the instrument could occur if not observed. A symbol on the instrument is referenced in the manual with a precautionary statement. This is the safety alert symbol. Obey all safety messages that follow this symbol to avoid potential injury. If on the instrument, refer to the instruction manual for operation or safety information. This symbol indicates the presence of a light source that may have the potential to cause minor eye injury. Obey all messages that follow this symbol to avoid potential eye injury. This symbol indicates the presence of devices sensitive to Electro-static Discharge (ESD) and indicated that care must be taken to prevent damage with the equipment. Electrical equipment marked with this symbol may not be disposed of in European public disposal systems after 12 August of 2005. In conformity with European local and national regulations (EU Directive 2002/98/EC), European electrical equipment users must now return old or end-of-life equipment to the Producer for disposal at no charge to the user. Note: For return for recycling, please contact the equipment producer or supplier for instructions on how to return endof-life equipment, producer-supplied electrical accessories, and all auxillary items for proper disposal. Product overview Chemical or biological hazards. If this instrument is used to monitor a treatment process and/or chemical feed system for whic h there are regulatory limits and monitoring requirements related to public health, public safety, food or beverage manufacture or processing, it is the responsibility of the user of this instrument to know and abide by any applicable regulation and to have sufficient and appropriate mechanisms in place for compliance with applicable regulations in the event of malfunction of the instrument. This sensor is designed to work with a controller for data collection and operation. The sensor can be used with several controllers. The primary applications for this sensor are municipal and industrial wastewater applications. LDO sensor technology does not consume oxygen, and can measure DO concentration in low or no-flow applications. Refer to Figure 1. Figure 1 LDO sensor English 4

1 Sensor cap 3 1-inch NPT 2 Temperature sensor 4 Connector, quick-connect (standard) LDO Sensor component list Make sure that all components shown in Figure 2 have been received. If any items are missing or damaged, contact the manufacturer or a sales representative immediately. Refer to Figure 2. Figure 2 Sensor component list 1 LDO sensor 1 1 Included user manual is not shown. Installation W A R N I N G Risk of personal injury. The work described here in the manual can be done only by qualified professional Not connect the sensor in a hazardous location Explosion hazard. This equipment is not suitable for use in hazardous locations or Class 1, Division 2, Groups A, B, C, D Hazardous Locations. Explosion hazard. Do not connect or disconnect electrical components or circuits to the equipment unless power has been removed. Meanwhile, be sure that the area is known to be non-hazardous. English 5

Sensor installation options The installation and accessory options available for the LDO sensor are supplied with installation instructions in the hardware kit. Figure 3 shows several installation options. To order installation hardware, refer to Replacement parts and accessories on page 9. N O T I C E If user cuts off the cable of probe for connecting controller, in order to keep moisture from entering into probe, the cable section must be sealed with epoxy. If using epoxy to seal is not convenient, users are proposed to purchase connector suitable for cable. The connector of HACH company (China factory P/N 3674020 ) meets this requirement. Figure 3 Installation options 1 Rail mount 4 Chain mount 2 Float mount 5 Union mount 3 Air blast system mount 6 English

Modbus Register Modbus Register list can be used by network communication. Modbus communication parameters of LDO II AQ are as follows: Modbus address: 247 Communication mode: RTU(Zf) Baud rate: 19.2Kbps. Parameters: 8 data bits, no parity bit, 1 stop bit Modbus Register list of LDO II AQ is as follows: Register number Name Date type Variable length (unit: )double byte Read-write operation Description 40001 Dissolved Oxygen Unsigned int 1 Read The latest measurements * 1000 Example:8082 means 8.082mg/L 40002 Temperature Unsigned int 1 Read The latest temperature * 100 Example:2641 meads 26.41 40003 Software version Unsigned int 1 Read Edition number * 100 Example:456 means edition 4.56 40004 Batch number Unsigned int 1 Read Example:13136 means the 136th batch in 2013 40005 Serial number Unsigned int 6 Read Hexadecimal code number stored by ASCII code Example:Register40005~400 10 that are respectively "3133","3132", "3330", "3030", "3030","3937" are respectively translated into ASCII code:"13","12","30", "00","97", then the result combined together by Hexadecimal is 13123000007 In terms of theory problem of dissolved oxygen detection, please refer to: * Standard Methods for the Examiniation of Water and Wastewater, 20th Edition. Editors Lenore S. Clesceri, Arnold E. Greenberg and Andrew D. Eaton, p. 2-48-2-29 (1998). The relationship between Chlorinity and Oxygen Solubitity is provided in the same reference in 4500-O:I p. 4-131. English 7

Maintenance Multiple hazards. Only qualified personnel must conduct the tasks described in this section of the document. Explosion hazard. Do not connect or disconnect electrical components or circuits to the equipment unless power has been switched off. Meanwhile, be sure the area is known to be non-hazardous. Maintenance schedule The maintenance schedule shows minimum intervals for regular maintenance tasks. Perform maintenance tasks more frequently for applications that cause electrode fouling. Note: Do not disassemble the probe for maintenance or cleaning. Maintenance task Clean the sensor Inspect the sensor for damage Recommended minimum frequency 90 days 90 days Clean the sensor Clean the exterior of the sensor with a soft, wet cloth. Note: If the sensor cap must be removed for cleaning, do not expose the interior of the cap to direct sunlight for extended periods of time. Set or change the clean interval Application conditions may need shorter or longer durations between manual sensor cleanings. The default clean interval is 0 days. To change the interval, refer to the steps in this procedure. Change the sensor cap W A R N I N G Potential explosion hazard. The sensor setup cap is not rated for hazardous location use. Replacement sensor caps and setup caps are shipped with installation instructions. Refer to the included instructions to change the cap. For best performance and accuracy, replace the sensor cap: Every two years When routine inspection shows significant erosion of the sensor cap 8 English

Replacement parts and accessories Replacement items Description Item no. (US / EU) LDO Probe, with one sensor cap and 2 calibration bags 9020000 Sensor cap, replacement (includes the sensor setup cap, which is not rated for use in Class 1, Division 2 hazardous locations) 9021100 / 9021150 Accessories Description Item no. (US / EU) Calibration package(1x) 5796600/5796600 Cable, sensor extension, non-hazardous location, 7.7 m (25 ft) 1 Hardware kit for pipe mount (PVC) Hardware kit for float mount (PVC) Hardware kit for air blast mount Hardware kit for chain mount (stainless steel) US: 5796000, 7.7 m (25 ft) EU: LZX849, 10 m (33 ft) 9253000 / LZY714.99.21810 9253100 / LZX914.99.42200 9253500 / LZY812 / LZX914.99.11200 Hardware kit for union mount 9257000 / 9257000 HQd meter with LDO rugged probe (not rated for use in hazardous locations) 8505200 / HQ40D.99.310.000 1 15 m (49 ft) and 30 m (98 ft) also available English 9