Flow and check valves Supplementary products Shuttle valves (OR) Brochure

Similar documents
Flow and check valves Non-return valves Series NR02. Brochure

Pressure regulators Pressure relief valves Safety valves. Brochure

Flow and check valves Logic valves series 551. Brochure

Pressure regulators Manually operated Fine setting valves. Brochure

Directional valves Pneumatically operated Series CD07. Brochure

Pneumatic connection technologies Fitting accessories Blanking screws and connectors. Brochure

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

Air-service devices, Series MU1

Compressed Air Conditioning Catalog Chapter I

Pressure reducing valve, direct operated

Type 4708 Supply Pressure Regulator

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Type 4708 Supply Pressure Regulator

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Type 4708 Supply Pressure Regulator

Pressure relief valve, direct operated

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Diaphragm Accumulators

1 0,1 0,1-70 0, , , , Cylinder bore <

Air preparation units

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

EXH. Specifications. Descriptions. Min. working pressure MPa

Pressure reducing valve, direct operated

Hand slide valves W/VBOH

AVP-F. p setting range (bar) Code No. 003H6200

4/2 way Pneumatic Solenoid Valve

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Dynamic Pneumatics Regulating with

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

Diaphragm Accumulators

Check valve hydraulically pilot operated

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Instruction Manual SB02, SB03, SB04 All metal flow limiter

PARTICULATE FILTER/REGULATOR

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

2/2-Way Solenoid Control Valve

Pressure reducing valve, pilot operated

AIR SUPPLY MANAGEMENT AN OVERVIEW OF COMPRESSED AIR PREPARATION AND ACCESSORIES

2/2-Way Proportional Valve (motor-driven)

Expansion Thermometers Stainless Steel Series, Model 70

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Self-operated Pressure Regulators for special applications

Solenoid valves VZWF, force pilot operated

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SITRANS P measuring instruments for pressure

BULLETIN E485B. Poppet Valve Construction Customized Solutions Plug-and-Play Design. Subject to technical modifications.

3-Way Safety Block DSV

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Diaphragm Accumulators

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Controllers DR, DP, FR and DFR

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Air service units series Y G1/4 to G1

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Preliminary filter Precision measurement chamber Flow meter Instruction manual

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

SPCH/ Blowing block

D62 - D63 Directional Control Valve l/min

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

Bladder Accumulators High pressure

Pressure relief valve, direct operated

Valve Proving System VDK 200 A S06*

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Air service units series K G1/8, G1/4

INSTRUCTION MANUAL LOW PRESSURE CALIBRATION PUMP MODEL PGL

Pressure Relief Valves. SPV, SPVF direct operated

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Safety Manual VEGAVIB series 60

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Pressure maintenance valve SDV-P / SDV-P-E

Series K Air service units G 1/8, G 1/4

GAS PRESSURE CONTROL UNIT TYPE 132

Proportional pressure regulators VPPE

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Hand slide valves W/VBOH

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

Transcription:

Flow and check valves Shuttle valves (OR) Brochure

2 Flow and check valves Shuttle valves (OR) Compressed air connection input: M5 - G 1/4 compressed air connection output: M5 - G 1/4 3 Qn = 80-6100 l/min pipe connection Compressed air connection input: M5 - G 1 compressed air connection output: M5 - G 1 5

Flow and check valves 3 Compressed air connection input: M5 - G 1/4 compressed air connection output: M5 - G 1/4 Version Poppet valve Sealing principle Soft sealing Working pressure min./max. Ambient temperature min./max. -20 C / +70 C Medium temperature min./max. -20 C / +70 C Medium Compressed air Max. particle size 5 µm Oil content of compressed air 0 mg/m³ - 1 mg/m³ P534_200 Materials: Housing Seals Threaded bushing Acrylonitrile Butadiene Rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS, see chapter Technical information. Housing material: Aluminum Material Threaded bushing: Aluminum Nominal flow Qn at 6 bar and Δp = 1 bar Compressed air connection Nominal width Working pressure min./max. Weight Fig. Part No. Input Output [bar] [kg] M5 M5 2 1 / 10 0.015 Fig. 1 5342000000 G 1/8 G 1/8 4 0.5 / 10 0.12 Fig. 2 5342010100 Ø6x1 Ø6x1 4 0.5 / 10 0.12 Fig. 3 5342010200 G 1/4 G 1/4 5 0.3 / 10 0.13 Fig. 4 5340170100 Fig. 1 D534_200_a

4 Flow and check valves Compressed air connection input: M5 - G 1/4 compressed air connection output: M5 - G 1/4 Fig. 2 D534_200_b Fig. 3 D534_200_c Fig. 4 D534_200_d

Flow and check valves Qn = 80-6100 l/min pipe connection Compressed air connection input: M5 - G 1 compressed air connection output: M5 - G 1 5 00108480 Version Poppet valve Logic function Sealing principle Soft sealing Working pressure min./max. 1 bar / 10 bar Ambient temperature min./max. +0 C / +80 C Medium temperature min./max. +0 C / +80 C Medium Compressed air Max. particle size 5 µm Oil content of compressed air 0 mg/m³ - 1 mg/m³ Materials: Housing Seals Threaded bushing Acrylonitrile Butadiene Rubber Technical Remarks The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS, see chapter Technical information. 1) Housing material: Polyamide 2) Housing material: Aluminum 3) Material Threaded bushing: Brass 4) Material Threaded bushing: Aluminum; Steel 5) Material Threaded bushing: Aluminum Nominal flow Qn at 6 bar and Δp = 1 bar Compressed air connection Qn Weight Fig. Note Part No. Input Output [l/min] [kg] M5 M5 80 0.011 Fig. 1 1); 3) 0821000004 G 1/8 G 1/8 640 0.038 Fig. 2 2); 4) 0821000002 G 1/4 G 1/4 1550 0.12 Fig. 2 2); 4) 0821000003 G 3/8 G 3/8 2150 0.4 Fig. 3 2); 5) 0821000010 G 1/2 G 1/2 2300 0.36 Fig. 3 2); 5) 0821000011 G 3/4 G 3/4 4800 0.51 Fig. 4 2); 5) 0821000014 G 1 G 1 6100 0.46 Fig. 4 2); 5) 0821000015

6 Flow and check valves Qn = 80-6100 l/min pipe connection Compressed air connection input: M5 - G 1 compressed air connection output: M5 - G 1 Fig. 1 L3 L1 B1 D1 L2 H3 2 H1 H2 1 1 B2 R1 00109111 Part No. R1 D1 L1 L2 L3 L4 H1 H2 H3 B1 SW * 0821000004 M5 4.3 26 16 15 26 13 5 14 5 * = depth of thread Fig. 2 00109112 Part No. R1 D1 L1 L2 L3 L4 H1 H2 H3 B1 SW * 0821000002 G 1/8 4.3 42 32 25 3.5 25 21 8.5 16 14 8 0821000003 G 1/4 5.5 67.5 55 38 8.5 36.2 30.2 13.2 25 22 12 * = depth of thread

Flow and check valves Qn = 80-6100 l/min pipe connection Compressed air connection input: M5 - G 1 compressed air connection output: M5 - G 1 7 Fig. 3 00109113 Part No. R1 R2 D1 D2 L1 L2 L3 H1 H2 H3 B1 B2 0821000010 G 3/8 G 3/8 34 4.5 72 44 18 72 30 15 35 17.5 0821000011 G 1/2 G 1/2 34 4.5 72 44 18 72 30 15 35 17.5 Fig. 4 00109116 Part No. R1 R2 D1 D2 L1 L2 L3 H1 H2 H3 B1 B3 0821000014 G 3/4 G 3/4 44 100 51 107 41 20.5 50 25 0821000015 G 1 G 1 44 100 51 107 41 20.5 50 25

AVENTICS GmbH Ulmer Straße 4 30880 Laatzen Phone +49 511 2136-0 Fax +49 511 2136-269 www.aventics.com info@aventics.com Find more contact information at www.aventics.com/contact Only use the AVENTICS products shown in industrial applications. Read the product documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When integrating the product into applications, note the system manufacturer s specifications for safe use of the product. The data specified only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that the products are subject to a natural process of wear and aging. 09-03-2015 An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. AVENTICS S.à.r.l.. This document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS S.a.r.l.. It may not be reproduced or given to third parties without its consent. PDF online