Proportional Pressure-Relief Cartridge Valve, Size 2...4

Similar documents
Inverse Proportional Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cartridge, Size 10

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Proportional Throttle Cartridges, Size 16

Electrically Operated Pressure-Relief Cartridge, Size 10

3-Way Pressure-Reducing Cartridge, Size 2 4

Pressure-Relief Cartridge Valve, Size 4

Cooler-Bypass Thermostat Valve, Size 16

Double Pilot Operated Cartridge Check Valve, Size 8

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Leak-Free Load-Control Valve SAE ½ psi flange

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Leak free Pipe Rupture Valve for Excavators

3-Way Safety Block DSV

Safety and Shut-off Block SAF/DSV

Pressure reducing valve, direct operated

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

Leak-Free Load-Control Valve, Size 20

Safety and Shut-off Block SAF/DSV

Pressure reducing valve, pilot operated

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Safety and Shut-off Block SAF/DSV

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Intrinsically safe solenoid valves on/off controls - ATEX certification

D62 - D63 Directional Control Valve l/min

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Fixed Displacement Motor A4FM

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Proportional Directional Valve System

Check valve hydraulically pilot operated

Pressure reducing valve, direct operated

Pressure reducing valve, pilot operated, Model 3DR

PRESSURE COMPENSATORS TECNORD

Safety and Shut-off Block SAF/DSV

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

The Size 16 Product Range

Solenoid valves VZWF, force pilot operated

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

SPCH/ Blowing block

Safety and Shut-off Block SAF/DSV

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Pressure relief valve, direct operated

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

Pressure relief valve, direct operated Type DBD

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10

[Instruments for vacuum measurement, checking and adjustment] 3

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Directional Controls

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Pressure relief valve, direct operated

Series K Air service units G 1/8, G 1/4

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

4/2 way Pneumatic Solenoid Valve

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Air service units series K G1/8, G1/4

Proportional pressure regulators VPPE

Fixed Displacement Plug-In Motor A2FE

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

Fixed Displacement Motor A4FM

PRESSURE SEQUENCE VALVE TYPE UZK

SDM to 8 sections monoblock valve D1WWDA02A

Cover headline. Cover subheadline. Check Valves

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

Applications. What moves your world

Directional Valves. Hydraulic Operated Directional Valves

Pneumatic valve islands

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:

Direct Operated Precision Regulator Modular Style. Standard Specifications

Air preparation units

Chapter 10: Bidirectional Flow Controls

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Axial Piston Variable Pump A10V(S)O (US-Version)

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Axial piston pumps type PVC

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Axial piston pumps type PVC

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Cartridge Valves Technical Information Proportional Valves Quick Reference

VSD03M DIRECTIONAL CONTROL VALVES

Type 4708 Supply Pressure Regulator

Transcription:

Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges of sliding-spool design with a 3/-16 UNF mounting thread. With these pressure-relief cartridges, the relief pressure is dependent on the electrical control signal and can be continuously varied. When the solenoid is de-energised (initial position), connection 1 is open and the minimum pressure (free flow) depends on the flow rate. Any pressure at port 1 is additive to the valve setting at port, therefore port 1 should preferably be connected directly to tank. In control mode, the relief pressure is proportional to the change in the required value (amplifier output current). In order to obtain precise pressure settings over the whole of the required pressure range (optimum resolution), the pressure relief cartridges are available in six Compact construction for cavity type AL 3/-16 UNF Operated by a proportional solenoid In a power failure, the pressure setting drops to the minimum value 6 pressure ranges available All exposed parts with zinc-nickel plating High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available With integral manual pressure setting Can be fitted in a line-mounting body spring ranges. If a proportional solenoid is faulty, for example, the integral manual pressure setting enables the required pressure to be set mechanically. Proportional pressure-relief cartridges are predominantly used in mobile and industrial applications to allow a pressure in hydraulic installations to be limited electro-proportionally. All external parts of the cartridge are zinc-nickel plated to DIN 979 and are thus suitable for use in the harshest operating environments. The slip-on coils can be replaced without opening the hydraulic envelope and can be positioned at any angle through 3. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol 1 3 Technical data General characteristics Designation Design Mounting method Tightening torque Size Weight proportional pressure-relief cartridge direct acting, electrically operated screw-in cartridge 3/-16 UNF Nm ± 1 % nominal size..., cavity type AL.5 kg Reference: -P-58531-EN-3 Issue: 11.18 1/6

General characteristics Mounting attitude Ambient temperature range unrestricted (preferably vertical, coil down) -5 C + C Hydraulic characteristics Maximum operating pressure - main port - port 1 3 bar bar 1) Maximum flow rate l/min ) Nominal pressure ranges Leakage flow rate 1 Flow direction 18 bar, 5 bar, 7 bar, 11 bar, 1 bar, bar 3).1 l/min = pressure range 18 bar / 5 bar.15 l/min = pressure range 7 bar. l/min = pressure range 11 bar.5 l/min = pressure range 1 bar / bar 1 see symbols Hydraulic fluid HL and HLP mineral oil to DIN 51 5; for other fluids, please contact BUCHER Hydraulic fluid temperature range Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 6 : 1999-5 C +7 C 15 38 mm /s (cst), recommended...13 mm /s (cst) class 18/16/13 1) To prevent any pressure surges, port 1 must be routed to tank with the least possible back-pressure. Any tank pressure acting at port 1 is additive to the pressure setting at the main port. ) Depending on the nominal pressure stage. 3) F or higher pressure to 3 bar can be used DBDTC. Electrical characteristics Supply voltage Control current Power consumption at max. control current Coil resistance R - cold value at C - max. warm value Recommended PWM frequency (dither) Hysteresis with PWM Reversal error with PWM Sensitivity with PWM Reproducibility with PWM 1 V DC, V DC 1 V = 1 ma, V = 7 ma max. 19 W 1 V = 5.8 / V = 1 1 V = 8.6 / V = 3 Hz % I N % I N < 1 % I N < % Switching time ms (Solenoid ON) 6 ms (Solenoid OFF) These times are strongly influenced by fluid pressure, flow rate and viscosity, as well as by the dwell time under pressure. Relative duty cycle Protection class to ISO 653 / EN 59 Electrical connection % IP 65 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) DIN EN 17531-83, 3-pin P+E (standard) for other connectors, see Ordering code /6 -P-58531-EN-3/11.18

Performance graphs measured with oil viscosity 33 mm /s (cst) p = f (I) Pressure adjustment characteristic (Q = 1 l/min) p 8 P16.ai p = f (I) Pressure adjustment characteristic (Q = 1 l/min) p P17.ai bar 5bar 18 bar 1bar 11bar 7 bar 3 7 I [ma] 8 1 p = f (Q) Pressure - Flow rate characteristic = 18 bar p 5 P16.ai 3 7 I [ma] 8 1 p = f (Q) Pressure - Flow rate characteristic = 5 bar p P165.ai 15 1 3 5 1 8 1 16 Q [l/min] 8 1 16 18 Q [l/min] p = f (Q) Pressure - Flow rate characteristic = 7 bar p 8 P166.ai p = f (Q) Pressure - Flow rate characteristic = 11 bar p 1 P167.ai 9 3 6 8 1 1 1 15 Q [l/min] p = f (Q) Pressure - Flow rate characteristic = 1 bar p P168.ai 6 8 1 1 13 Q [l/min] p = f (Q) Pressure - Flow rate characteristic = bar p 3 P169.ai 6 8 9 Q [l/min] 1 3 5 6 Q [l/min] -P-58531-EN-3/11.18 3/6

5 Dimensions & sectional view 3 8 1 5 3/ 16 UNF M A = [Nm] ±1 % 1 Ø 36 66. 17. 135. B M A =.7 [Nm] 1 % 13 M A = 1 [Nm] ±1 % A M A = 1 [Nm] ±1% 5.5 7.5 Seal kit NBR no. DS-8-N 1) Item Qty. Description 1 1 O-ring 18. x. FKM Integral air-bleeding If necessary, air can be purged from these proportional pressure-relief cartridges by using the integral air-bleed screw (Item B). The procedure is as follows: 1 O-ring no. 17 17.17 x 1.78 N9 3 1 O-ring no. 1 1. x 1.78 N9 O-ring 16. x. FKM A B Protective cap Air-bleed screw 5 1 Backup ring 1.7 x 1.5 x 1. FI751 IMPORTANT! 1) Seal kit with FKM (Viton) seals no. DS-8-V Steps: Remove the protective cap. Slacken the air-bleed screw approx. turns. Switch the pressure-relief cartridge ON/OFF several times until no more air bubbles escape. Tighten the air-bleed screw (Ma = 1 Nm 1%). Fit the protective cap. /6 -P-58531-EN-3/11.18

6 Installation information IMPORTANT! To achieve the proportional pressure-relief cartridge's maximum performance rating, fit the solenoid coil as shown (plug socket downwards or to the valve end). When fitting the cartridges, note the mounting attitude (preferably vertical, with coil down " automatic air bleed) and use the specified tightening torque. No adjustments are necessary, since the cartridges are set in the factory. Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. To prevent any pressure surges, port 1 must be routed to tank with the least possible back-pressure. Any tank pressure acting at port 1 is additive to the pressure setting at the main port. 7 Manual pressure setting The proportional pressure relief cartridges are equipped with manual emergency pressure adjustment as standard. This allows the desired pressure value to be set mechanically, e.g. in the event of failure of the electrical control or the proportional solenoid. The emergency pressure setting is not intended for adjusting pressure values in solenoid operation and must then be reset to the factrory setting. IMPORTANT! Any changes to the manual emergency pressure setting have a direct effect on the factory settings. E D 13 M A = 1 [Nm] ± 1 % C Setting the pressure manually Steps: Remove the protective cap. Slacken the lock nut (13 A/F). Screw in (turn to right) the adjusting spindle ( A/F) until the required pressure is set. Tighten the lock nut (13 A/F). Fit the protective cap. To reset the inverse proportional pressure-relief cartridges to their initial position (the factory setting), a constant flow rate and a pressure gauge that measures the pressure in the main port are needed. Restoring the factory settings Steps: Solenoid de-energised. Remove the protective cap. C D E Protective cap Lock nut (13 A/F) Adjusting spindle for pressure setting Slacken the lock nut (13 A/F). Unscrew the adjusting spindle ( A/F) to its end-stop, then screw it in until the pressure on the gauge just starts to rise. Unscrew the spindle again by: bar = 1/ of a turn 1, 11, 7 bar = 1/ of a turn 5, 18 bar = 3/ of a turn Tighten the lock nut (13 A/F). Fit the protective cap. -P-58531-EN-3/11.18 5/6

8 Ordering code D B D S B - 1 L - - _ - 3 D _ D = pressure control valve B = pressure relief function D = direct acting S = standard solenoid (proportional) B... Q = standard model - see relevant data sheets Z... R = special features - please consult BUCHER 1 = pressure function 1 L = cavity type AL = pressure range bar 1) 1 = pressure range 1 bar 11 = pressure range 11 bar 7 = pressure range 7 bar 5 = pressure range 5 bar 18 = pressure range 18 bar = nominal size for pressure ranges and 1 3 = nominal size 3 for pressure ranges 11 and 7 = nominal size for pressure ranges 5 and 18 (blank) = NBR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please contact BUCHER) 1... 9 = design stage (omit when ordering new units)... = voltage e.g. ( V) D = current DC (blank) = DIN EN 17531-83 connection with mating plug (standard, IP 65) M = DIN EN 17531-83 connection without mating plug C = Kostal plug connection (IP 65) JT = Junior Timer radial plug connection (with protection diode, IP65) IT = Junior Timer axial plug connection (with protection diode, IP65) D = Deutsch plug connection DT-P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT-P (with protection diode, IP 67/69K) S = AMP Superseal 1.5 (IP67) / Metri-Pack (IP65) plug connection F = flying leads ( mm) 1) for higher pressure to 3 bar can be used the valve DBDTC. 9 Related data sheets Reference (Old no.) Description -P-11 (i-3) The form-tool hire programme -P-171 Cavity type AL -P-111 (W-.11) Coils for screw-in cartridge valves -P-5111 -P-585111 -P-711 info.ch@bucherhydraulics.com Amplifier unit for proportional valves (1-channel) PBS - 3A Prop. Pressure-Relief Cartridge Valve, Size.., type DBDTC-1L Line-mounting body, type GALA (G 3/ ) www.bucherhydraulics.com 18 by Bucher Hydraulics AG Frutigen, CH-371 Frutigen All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 3.35.3.35.35.31 6/6 -P-58531-EN-3/11.18