Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges of sliding-spool design with a 3/-16 UNF mounting thread. With these pressure-relief cartridges, the relief pressure is dependent on the electrical control signal and can be continuously varied. When the solenoid is de-energised (initial position), connection 1 is open and the minimum pressure (free flow) depends on the flow rate. Any pressure at port 1 is additive to the valve setting at port, therefore port 1 should preferably be connected directly to tank. In control mode, the relief pressure is proportional to the change in the required value (amplifier output current). In order to obtain precise pressure settings over the whole of the required pressure range (optimum resolution), the pressure relief cartridges are available in six Compact construction for cavity type AL 3/-16 UNF Operated by a proportional solenoid In a power failure, the pressure setting drops to the minimum value 6 pressure ranges available All exposed parts with zinc-nickel plating High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Various plug-connector systems and voltages are available With integral manual pressure setting Can be fitted in a line-mounting body spring ranges. If a proportional solenoid is faulty, for example, the integral manual pressure setting enables the required pressure to be set mechanically. Proportional pressure-relief cartridges are predominantly used in mobile and industrial applications to allow a pressure in hydraulic installations to be limited electro-proportionally. All external parts of the cartridge are zinc-nickel plated to DIN 979 and are thus suitable for use in the harshest operating environments. The slip-on coils can be replaced without opening the hydraulic envelope and can be positioned at any angle through 3. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol 1 3 Technical data General characteristics Designation Design Mounting method Tightening torque Size Weight proportional pressure-relief cartridge direct acting, electrically operated screw-in cartridge 3/-16 UNF Nm ± 1 % nominal size..., cavity type AL.5 kg Reference: -P-58531-EN-3 Issue: 11.18 1/6
General characteristics Mounting attitude Ambient temperature range unrestricted (preferably vertical, coil down) -5 C + C Hydraulic characteristics Maximum operating pressure - main port - port 1 3 bar bar 1) Maximum flow rate l/min ) Nominal pressure ranges Leakage flow rate 1 Flow direction 18 bar, 5 bar, 7 bar, 11 bar, 1 bar, bar 3).1 l/min = pressure range 18 bar / 5 bar.15 l/min = pressure range 7 bar. l/min = pressure range 11 bar.5 l/min = pressure range 1 bar / bar 1 see symbols Hydraulic fluid HL and HLP mineral oil to DIN 51 5; for other fluids, please contact BUCHER Hydraulic fluid temperature range Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 6 : 1999-5 C +7 C 15 38 mm /s (cst), recommended...13 mm /s (cst) class 18/16/13 1) To prevent any pressure surges, port 1 must be routed to tank with the least possible back-pressure. Any tank pressure acting at port 1 is additive to the pressure setting at the main port. ) Depending on the nominal pressure stage. 3) F or higher pressure to 3 bar can be used DBDTC. Electrical characteristics Supply voltage Control current Power consumption at max. control current Coil resistance R - cold value at C - max. warm value Recommended PWM frequency (dither) Hysteresis with PWM Reversal error with PWM Sensitivity with PWM Reproducibility with PWM 1 V DC, V DC 1 V = 1 ma, V = 7 ma max. 19 W 1 V = 5.8 / V = 1 1 V = 8.6 / V = 3 Hz % I N % I N < 1 % I N < % Switching time ms (Solenoid ON) 6 ms (Solenoid OFF) These times are strongly influenced by fluid pressure, flow rate and viscosity, as well as by the dwell time under pressure. Relative duty cycle Protection class to ISO 653 / EN 59 Electrical connection % IP 65 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) DIN EN 17531-83, 3-pin P+E (standard) for other connectors, see Ordering code /6 -P-58531-EN-3/11.18
Performance graphs measured with oil viscosity 33 mm /s (cst) p = f (I) Pressure adjustment characteristic (Q = 1 l/min) p 8 P16.ai p = f (I) Pressure adjustment characteristic (Q = 1 l/min) p P17.ai bar 5bar 18 bar 1bar 11bar 7 bar 3 7 I [ma] 8 1 p = f (Q) Pressure - Flow rate characteristic = 18 bar p 5 P16.ai 3 7 I [ma] 8 1 p = f (Q) Pressure - Flow rate characteristic = 5 bar p P165.ai 15 1 3 5 1 8 1 16 Q [l/min] 8 1 16 18 Q [l/min] p = f (Q) Pressure - Flow rate characteristic = 7 bar p 8 P166.ai p = f (Q) Pressure - Flow rate characteristic = 11 bar p 1 P167.ai 9 3 6 8 1 1 1 15 Q [l/min] p = f (Q) Pressure - Flow rate characteristic = 1 bar p P168.ai 6 8 1 1 13 Q [l/min] p = f (Q) Pressure - Flow rate characteristic = bar p 3 P169.ai 6 8 9 Q [l/min] 1 3 5 6 Q [l/min] -P-58531-EN-3/11.18 3/6
5 Dimensions & sectional view 3 8 1 5 3/ 16 UNF M A = [Nm] ±1 % 1 Ø 36 66. 17. 135. B M A =.7 [Nm] 1 % 13 M A = 1 [Nm] ±1 % A M A = 1 [Nm] ±1% 5.5 7.5 Seal kit NBR no. DS-8-N 1) Item Qty. Description 1 1 O-ring 18. x. FKM Integral air-bleeding If necessary, air can be purged from these proportional pressure-relief cartridges by using the integral air-bleed screw (Item B). The procedure is as follows: 1 O-ring no. 17 17.17 x 1.78 N9 3 1 O-ring no. 1 1. x 1.78 N9 O-ring 16. x. FKM A B Protective cap Air-bleed screw 5 1 Backup ring 1.7 x 1.5 x 1. FI751 IMPORTANT! 1) Seal kit with FKM (Viton) seals no. DS-8-V Steps: Remove the protective cap. Slacken the air-bleed screw approx. turns. Switch the pressure-relief cartridge ON/OFF several times until no more air bubbles escape. Tighten the air-bleed screw (Ma = 1 Nm 1%). Fit the protective cap. /6 -P-58531-EN-3/11.18
6 Installation information IMPORTANT! To achieve the proportional pressure-relief cartridge's maximum performance rating, fit the solenoid coil as shown (plug socket downwards or to the valve end). When fitting the cartridges, note the mounting attitude (preferably vertical, with coil down " automatic air bleed) and use the specified tightening torque. No adjustments are necessary, since the cartridges are set in the factory. Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. To prevent any pressure surges, port 1 must be routed to tank with the least possible back-pressure. Any tank pressure acting at port 1 is additive to the pressure setting at the main port. 7 Manual pressure setting The proportional pressure relief cartridges are equipped with manual emergency pressure adjustment as standard. This allows the desired pressure value to be set mechanically, e.g. in the event of failure of the electrical control or the proportional solenoid. The emergency pressure setting is not intended for adjusting pressure values in solenoid operation and must then be reset to the factrory setting. IMPORTANT! Any changes to the manual emergency pressure setting have a direct effect on the factory settings. E D 13 M A = 1 [Nm] ± 1 % C Setting the pressure manually Steps: Remove the protective cap. Slacken the lock nut (13 A/F). Screw in (turn to right) the adjusting spindle ( A/F) until the required pressure is set. Tighten the lock nut (13 A/F). Fit the protective cap. To reset the inverse proportional pressure-relief cartridges to their initial position (the factory setting), a constant flow rate and a pressure gauge that measures the pressure in the main port are needed. Restoring the factory settings Steps: Solenoid de-energised. Remove the protective cap. C D E Protective cap Lock nut (13 A/F) Adjusting spindle for pressure setting Slacken the lock nut (13 A/F). Unscrew the adjusting spindle ( A/F) to its end-stop, then screw it in until the pressure on the gauge just starts to rise. Unscrew the spindle again by: bar = 1/ of a turn 1, 11, 7 bar = 1/ of a turn 5, 18 bar = 3/ of a turn Tighten the lock nut (13 A/F). Fit the protective cap. -P-58531-EN-3/11.18 5/6
8 Ordering code D B D S B - 1 L - - _ - 3 D _ D = pressure control valve B = pressure relief function D = direct acting S = standard solenoid (proportional) B... Q = standard model - see relevant data sheets Z... R = special features - please consult BUCHER 1 = pressure function 1 L = cavity type AL = pressure range bar 1) 1 = pressure range 1 bar 11 = pressure range 11 bar 7 = pressure range 7 bar 5 = pressure range 5 bar 18 = pressure range 18 bar = nominal size for pressure ranges and 1 3 = nominal size 3 for pressure ranges 11 and 7 = nominal size for pressure ranges 5 and 18 (blank) = NBR (Nitrile) seals (standard) V = FKM (Viton) seals (special seals - please contact BUCHER) 1... 9 = design stage (omit when ordering new units)... = voltage e.g. ( V) D = current DC (blank) = DIN EN 17531-83 connection with mating plug (standard, IP 65) M = DIN EN 17531-83 connection without mating plug C = Kostal plug connection (IP 65) JT = Junior Timer radial plug connection (with protection diode, IP65) IT = Junior Timer axial plug connection (with protection diode, IP65) D = Deutsch plug connection DT-P (IP 67/69K) mating plug not supplied DT = Deutsch plug connection DT-P (with protection diode, IP 67/69K) S = AMP Superseal 1.5 (IP67) / Metri-Pack (IP65) plug connection F = flying leads ( mm) 1) for higher pressure to 3 bar can be used the valve DBDTC. 9 Related data sheets Reference (Old no.) Description -P-11 (i-3) The form-tool hire programme -P-171 Cavity type AL -P-111 (W-.11) Coils for screw-in cartridge valves -P-5111 -P-585111 -P-711 info.ch@bucherhydraulics.com Amplifier unit for proportional valves (1-channel) PBS - 3A Prop. Pressure-Relief Cartridge Valve, Size.., type DBDTC-1L Line-mounting body, type GALA (G 3/ ) www.bucherhydraulics.com 18 by Bucher Hydraulics AG Frutigen, CH-371 Frutigen All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 3.35.3.35.35.31 6/6 -P-58531-EN-3/11.18