Double throttle/check valve, Type Z2FS Series 30 Huade América 1

Similar documents
Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Size 6 up to 31.5MPa 1) up to 25 L/min

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Meter-in pressure compensator, direct operatedtype ZDC

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, direct operated

PRESSURE SEQUENCE VALVE TYPE UZK

Pressure reducing valve, direct operated

Check valve hydraulically pilot operated

Pressure reducing valve, pilot operated

2-way flow control valve Model 2FRM 6

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Pressure reducing/relief valve, pilot operated type UZCP10

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

Leak free Pipe Rupture Valve for Excavators

Pressure relief valve, direct operated Type DBD

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Pressure relief valves

Pressure relief valve, direct operated

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

FLOW CONTROL VALVES FLOW CONTROL VALVE HF WITH PRESSURE COMPENSATION SIZE 01 E 4. Description of the model designation. Outside dimensions

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

Power Valve: Precision Regulator. High precision, large capacity relief regulator

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

Pressure-Relief Cartridge Valve, Size 4

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Directional spool valves type WE6 electrically. operated type WE6 series 32

Axial piston pumps type PVC

Axial piston pumps type PVC

Pressure relief valve, direct operated

Cooler-Bypass Thermostat Valve, Size 16

Directional Valves. Hydraulic Operated Directional Valves

Digital directional & flow control valves D-DF(R)G

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

Intrinsically safe solenoid valves on/off controls - ATEX certification

Proportional Throttle Cartridges, Size 16

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Inverse Proportional Pressure-Relief Cart., Size 2 4

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Directional Controls

Change-Over Pressure Filter DFDK

Priority (Swing) Motors Data and Specifications

Proportional Pressure-Relief Cartridge Valve, Size 2...4

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

Inverse Proportional Pressure-Relief Cart., Size 2 4

SDM to 8 sections monoblock valve D1WWDA02A

Inverse Prop. Pressure-Relief Cart., Size 2 4

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Proportional Pressure-Relief Cartridge Valve, Size 2...4

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

Electrically Operated Pressure-Relief Cartridge, Size 10

Fixed Displacement Plug-In Motor A2FE

* Different spooltypes up to 120 l/min. in combination with simultaneously control.

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Double Pilot Operated Cartridge Check Valve, Size 8

3-Way Pressure-Reducing Cartridge, Size 2 4

Directional Controls

3-Way Safety Block DSV

Hand & mechanical directional valves

Flow control valves Series RFU - RFO 2/

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

005 Series Modular Valves

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Inverse Proportional Pressure-Relief Cartridge, Size 10

Monoblock directional control valves ML - Directional control valve

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

SystemStak Valves. ISO4401 Size 02

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

Digital relief valves D-CG

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

WW-720. Pressure Reducing Control Valve

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Fixed Displacement Motor A4FM

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

SOLENOID VALVES AND PNEUMATIC VALVES

Monoblock Directional Control Valve RMB 202

Technical Data Sheet TI-F50 Locking Units series KFH

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Pressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:

Flow rates to 200 l/min

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

EXH. Specifications. Descriptions. Min. working pressure MPa

Transcription:

Double throttle/check valve, Type Z2FS Series 30 Huade América 1

BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Double throttle/check valve, Type Z2FS Series 30 Sizes 6 16 22 up to 31.5MPa up to 350 L/min RE:27505/12.2004 Replaces RE27505/5.2001 Features: - Sandwich plate design - Porting pattern to DIN 24 340, from A,ISO 4401 and CETOP-RP 121H - Limiting of main or pilot flow with two service ports, - Meter-in or meter-out control. Functional, Section Valves type Z 2 FS are double throttle/check valves in sandwich plate design.they are used to limit main or pilot oil flow at one or two service ports.two symmetrically arranged throttle/check valves limit flow (by means of adjustable throttle spools) in one direction and permit free return flow in the other direction. Main flow limiting The double throttle/check valve is fitted between the directional valve and the subplate to change the speed of an actuator (main flow limiting). Pilot flow limiting In the case of pilot operated directional valves, the double throttle/check valve may be used as a pilot choke adjustment (pilot flow limiting). In this case, it is fitted between the main valve and the pilot valve. Double throttle/check valve, Type Z2FS6 Meter-in control S Meter-out control S2 A Meter-out control B Meter-in control:s3 A Meter-in control B Meter-out control:s4 Huade América 2

Principle of Hydraulic systems Meter-in control S Meter-out control S2 Meter-out control on port A Meter-in control:s3 on potr B Meter-in control on port A Meter-out control:s on port B Ordering details Z2FS -30 B / * Double throttle/check valve Further details in clear text Nominal size 6 = 6 Nominal size 16 = 16 Nominal size 22 = 22 Series 30 to 39 =30 (30 to 39: unchanged installation and connection dimensions) Technology of Beijing Huade Hydraulic =B No code= Mineral oil V= Phospate ester No code = (With two throttle/check valves) S = Meter-in S2 = Meter-out S3 = Meter-out on port A, meter-in on port B S4 = Meter-in on port A, meter-out on port B Technical data (for applications outside these parameters, please consult us!) Size 6 16 22 Maximum flow (L/min) 80 250 350 Maximum working pressure (MPa) 31.5 35 Pressure fluid Mineral oil (for NBR seal) or Phospate ester (for FPM seal) Viscosity range (mm 2 /s) 10 to 800 Fluid temperature range ( ) -30 to +80 Huade América 3

Characteristic curves (measured at v = 41 mm 2 /s and t = 50 p in relationship to the flow q V via the check valve (throttle closed) Z2FS6 Z2FS16 Z2FS22 p in relationship to the flow q V at a constant throttle setting. Z2FS6 Z2FS16 in MPa Throttle setting in turns in MPa Throttle setting in turns in MPa in MPa in MPa Huade América 4

Characteristic curves (measured at v = 41 mm 2 /s and t = 50 p in relation to the flow q V at constant throttle setting Z2FS22 in MPa Throttle setting in turns Unit dimensions (Dimensions in mm) Type Z2FS6: 1 Name plate 2 Setting screw for alteration of flow cross section 3 Turn anti-clockwise = increases flow turn clockwise = decreases flow 4 Valve fixing holes 5 Ports A, B, P, T 6 O-ring plate 7 To change from meter-in to meter-out,rotate the unit about the "X"-"X" axis Huade América 5

Unit dimensions (Dimensions in mm) Type Z2FS16: ~ééêçñk=ã~ñ=ovq ~ééêçñk=ã~ñ=oqs Type Z2FS22 ~ééêçñk=ã~ñ=pom ~ééêçñk=ã~ñ=osu 1 Name plate 2 Setting screw for alteration of flow cross section 3 Turn anti-clockwise = increases flow turn clockwise = decreases flow 4 2 two locating pins 5 2 two locating pins holes 6 6 Valve fixing holes 7 O-ring for ports A, B, P, T 8 O-ring for ports X, Y, L Huade América 6

Notice 1. The fluid must be filtered. Minimum filter fineness is 20 μm. 2. The tank must be sealing up and an air filter must be installed on air entrance. 3. Products without subplate when leaving factory, if need them, please ordering specially. 4. Valve fixing screws must be high intensity level (class 10.9). Please select and use them according to the parameter listed in the sample book. 5. Roughness of surface linked with the valve is required to. 6. Surface finish of mating piece is required to 0.01/100mm. Huade América 7