TECHNICAL INSTRUCTION

Similar documents
TECHNICAL INSTRUCTION

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

OPERATION MANUAL. SRDK Series CRYOCOOLER. For Service Personnel Only. Sumitomo Heavy Industries, Ltd. Cryogenics Division

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

Compressors. Basic Classification and design overview

CH-210 Cold Head. Operating Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

BIMA cryogenics (Dick Plambeck, 18jan2007)

OPERATOR, ORGANIZATIONAL, DIRECT AND GENERAL SUPPORT AND DEPOT MAINTENANCE MANUAL COMPRESSOR, RECIPROCATING, AIR; 15 CFM, 175 PSI;

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

INSTALLATION, OPERATION

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Cryogenic Engineering Prof. M. D. Atrey Department of Mechanical Engineering Indian Institute of Technology, Bombay

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015

Operation Manual Air Saver Unit ASV5000 Series

9600 Compressor Installation, Operation, and Maintenance Instructions Rev. G (1/99)

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

Double Stage Low Pressure Regulator JUMBO KOSAN Type 584

Oxford Instruments Austin, Inc.

CNG FILLING STATIONS

Linde Cryogenics. Helium Recovery Systems.

9600 (High Voltage) Compressor Installation, Operation, and Maintenance Instructions

Investigation of failure in performance of linear compressor & its rectifications

APPS-160 Gen 2 User Manual

Code AWC20HP Air Compressor

Data Sheet Issue A

PART 1: System Instructions

Introduction to Pneumatics

Oxford Instruments Austin, Inc.

LOCK UP VALVES YT-400/405/430/435 SERIES

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

CHAPTER 3 : AIR COMPRESSOR

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

Cryogenic Refrigerator. INSTALLATION, OPERATION and ROUTINE MAINTENANCE MANUAL

Noth American 7347 High Pressure Gas Regulators

HELIX. On-Board IS Cryopump Installation Instructions

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors

Operating Instructions Models and Hydrostatic Test Pumps

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES

3 & 4-Way Mixing & Diverting Valves

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

Storage Systems and Accessories

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

TWO POST RAM PACKAGE 55 GALLON

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

ASSE International Product (Seal) Listing Program

Cryo-Torr Pump Installation, Operation and Maintenance Instructions

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

EXH. Specifications. Descriptions. Min. working pressure MPa

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

RHIC CRYOGENIC SYSTEMS MAINTENANCE PROGRAM

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

Experimental Investigation on Stirling type Thermally Coupled Three Stage Pulse tube Cryocoolers with U type Configuration

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Budget Range Operators Handbook

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Operating Instructions Model and Hydrostatic Test Pump

Development of Large Capacity CO2 Scroll Compressor

Operation & Service Manual

North American 7339 High Pressure Gas Regulators

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES

RhinoPro Cartridge Gun Manual

Proportional Pressure-Relief Cartridge Valve, Size 2...4

NGP-250/500 Nitrogen Generator Quick Start Guide

Full Range Pressure Compensating Variable Flow Control

Gas Hydraulic Valve Operator

CKE2500 HYDRAULIC CRAWLER CRANE GENERAL DIMENSIONS. Max. Lifting Capacity

Series IRV1000/2000/3000

Inert Air (N2) Systems Manual

COMPRESSOR, RECIPROCATING: AIR HANDTRUCK MOUNTED, GASOLINE ENGINE DRIVEN, 8 CFM, 175 PSI (C & H DISTRIBUTORS MODEL ) NSN

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

Development Of The Compressor For Miniature Pulse Tube Cryocooler

ASSE International Product (Seal) Listing Program

Inverse Prop. Pressure-Relief Cart., Size 2 4

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Data Sheet Issue A

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Automatic Non-freeze Valve NF6

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Pilot Check Valve: Metal Body Type

Liquid ring compressors

SANP ACTING RELAYS YT-520/525/530 SERIES

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Nikuni KTM Series Pumps

30T A/Manual Hydraulic Shop Press

CYCLE ANALYSIS OF LINEAR COMPRESSORS USING THREE- DIMENSIONAL CFD

OPERATING AND MAINTENANCE MANUAL

Transcription:

MANUAL NUMBER: CD32ZZ-064D DATE: JUNE 9 / 2003 RDK-408D 4K COLD HEAD For Service Personnel Only Cryogenics Division 2-1-1 Yato-cho, Nishitokyo-City, Tokyo 188-8585, Japan TEL: +81-424-68-4240 FAX: +81-424-68-4219 E-mail: cryo@shi.co.jp URL: http://www.shi.co.jp/cryopage

TABLE OF CONTENTS TABLE OF CONTENTS SECTION ITEM PAGE No. CROSS REFERANCE 1 1 GENERAL INFORMATION 2 1-1 SPECIFICATIONS 3 1-2 CONSTRUCTION 5 2 MAINTENANCE 7 APPENDIX DRAWINGS REVISION CONTROL RDK-408D

CROSS REFERENCE CROSS REFERENCE Thoroughly read this manual and following manuals before using this equipment. MANUAL NAME MANUAL No. OPERATION MANUAL SRDK Series CRYOCOOLER* CD32ZZ-063 OPERATION MANUAL SRDK Series CRYOCOOLER* (for Outdoor used Compressor Unit) CD32ZZ-076 CSA-71A COMPRESSOR UNIT** CD32ZZ-067 CSW-71C COMPRESSOR UNIT** CD32ZZ-068 CSW-71D COMPRESSOR UNIT** CD32ZZ-069 CNA-61C OUTDOOR USED COMPRESSOR UNIT** CNA-61D OUTDOOR USED COMPRESSOR UNIT** * See of Compressor Unit used. ** See of Compressor Unit used. CD32ZZ-077 CD32ZZ-078 RDK-408D 1

1 GENERAL INFORMATION 1 GENERAL INFORMATION The RDK-408D Cold Head is a two-stage GM cycle cryo-refrigerator. The function of the Cold Head is to produce continuous closed-cycle refrigeration at temperatures, depending upon the heat load imposed, in the range of 25 K to 40 K for the first-stage cold station and in the range of 3.5 K to 4.2 K for the secondstage cold station. The Cold Head has three major components: the drive unit; the cylinder; and the displacer-regenerator assembly, which is located inside the cylinder. With newly developed rare earth regenerator material and with very unique structure, the model RDK- 408D Cold Head has its 2nd stage refrigeration capacity of 1W at 4.2K. Functionally, the high-pressure helium gas from the Compressor Unit will be supplied to the Cold Head through the helium gas supply connector. The supply gas will be passed into the displacer-regenerator assembly, come out through the displacer-regenerator assembly to the crankcase through the motor housing, and finally will be returned to the Compressor Unit through the helium gas return connector. The helium gas expansion in the displacer-regenerator assembly will be provided cooling condition for the first and second-stage cold stations. RDK-408D 2

1-1 SPECIFICATIONS 1-1 SPECIFICATIONS The specifications of the RDK-408D Cold Head are summarized in Table 1.1 Figure 1.1 shows the outline view of Cold Head. Table 1.1 RDK-408D COLD HEAD SPECIFICATION Refrigeration Capacity First Stage Second Stage Orientation Ambient Operating Temperature Helium Gas Pressure for Indoor Used Compressor Unit Static Operating (High Side)* for Outdoor Used Compressor Unit Static Operating (High Side)* Pressure Relief Valve Setting Gas Supply Connector Gas Return Connector Dimension Width Length Height Weight 31 / 37 W at 40 K (50 / 60 Hz) 1.0 W at 4.2 K (50 / 60 Hz) Any Capacity Loss: Max. 15% 5 to 28 deg.c (41 to 82.4 deg.f) 28 to 35 deg.c (82.4 to 95 deg.f) with 5% Capacity Loss 1.60-1.65 MPa at 20 deg.c (68 deg.f) (16.3-16.8 kgf/cm 2 G, 232-239 psig) 2.10-2.30 MPa --- approx. (21.4-23.5 kgf/cm 2 G, 304-333 psig) 1.60-1.70 MPa at 20 deg.c (68 deg.f) (16.3-17.3 kgf/cm 2 G, 232-246 psig) 1.90-2.10 MPa --- approx. (19.4-21.4 kgf/cm 2 G, 275-304 psig) 1.86-1.96 MPa (19.0-20.0 kgf/cm 2 G, 270-284 psig) 1/2-inch Coupling 1/2-inch Coupling 180 mm (7.09 ) 294 mm (11.58 ) 557 mm (21.93 ) 18.0 kg (39.6 LBS) --- approx. * The operating pressure varies according to the heat load of cold head and temperature around the equipment. RDK-408D 3

1-1 SPECIFICATIONS Figure 1.1 OUTLINE VIEW OF COLD HEAD MODEL RDK-408D RDK-408D 4

1-2 CONSTRUCTION 1-2 CONSTRUCTION The cross section of the RDK-408D Cold Head is shown in Figure 1.2. It consists of a Cylinder, No. 1 Displacer, No. 2 Displacer, drive mechanism, and Cold Head Drive Motor. No. 1 Displacer is connected to the Scotch Yoke which can be driven by the Cold Head Drive Motor through the Crank with Bush so that the rotation of the Cold Head Drive Motor can be varied to reciprocating motion of Scotch Yoke and Displacers. The Rotary Valve system is furnished to control the helium gas intake and exhaust timing. The Rotary Valve is also coupled to the Cold Head Drive Motor through Crank, so intake and exhaust operation is synchronized with the position of the Displacer. The Displacer is a loose fit in the Cylinder except at the top and where it is equipped with a dynamic(sliding) seal to prevent leakage passed through the clearance between the Displacer and Cylinder. The Displacers consist of regenerator material which cool the gas when passing downwards to the cold space and heats the gas when passing upwards from the cold space. Rear earth regenerator material is used in the 2nd stage Displacer to produce the cooling capacity at the temperature of 4.2K. The pressure above and below the Displacer is the same except for small pressure drops across the regenerator when gas is flowing trough it. Virtually no physical work is required to move the Displacer in the Cylinder. No work is done on the gas and the gas does no work on the Displacer. The pressure in the system is increased or decreased by operation of the inlet or outlet valves. RDK-408D 5

1-2 CONSTRUCTION Figure 1.2 CROSS SECTION OF THE RDK-408D COLD HEAD RDK-408D 6

2 MAINTENANCE 2 MAINTENANCE The RDK-408D Cold Head is to be required to replace the sliding parts inside every 10,000 Hrs. The maintenance work is not a User s maintenance. Replace the Cold Head completely at site and return it to for refurbishment. RDK-408D 7

APPENDIX APPENDIX DRAWINGS No. PART NAME 1 RDK-408D COLD HEAD RDK-408D 8

RDK-408D COLD HEAD

REVISION CONTROL REVISION CONTROL Manual No. CD32ZZ-064 Revision Remarks Date -A Publication of first edition. DEC. 10 / 1999 -B Add the CNA-61C, D Compressor Unit OCT. 2 / 2000 -C Change the SHI address. JAN. 25 / 2001 -D Change the division name. JUNE 9 / 2003 RDK-408D