Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Similar documents
INSTALLING THE ECHO SOUNDER TRANSDUCER CHANGING THE OPERATING CONFIGURATION

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

Depth transducer TH 52

Methylethycetone (MEC) - PMS 60 polyurethane glue - Grease - White silicone

Panoptix PS51-TH FrontVü/LiveVü Thruhull

Underwater Fiber-Optic Plane Irradiance Collector

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

RAI-M series RUDDER ANGLE INDICATOR SYSTEM

FIREFIGHTING EQUIPMENT

INSTALLATION AND USER INSTRUCTIONS for TARGET 2 LOG, DEPTH & WIND MARINE INSTRUMENTS

Pressure Dump Valve Service Kit for Series 2300 Units

STARLOG. Capacitive Water Depth Probe

Pneumatic spool valve islands

PAPR Flow Tester. instructions. part no WARNING

Quick Installation Guide Doc nr.: C Date:

Model PSI Compressor with 3-Gallon Air Tank 12VDC

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

CLIPPER DUET M P H DEPTH F E E T SPEED TOTAL TRIP ILLUM. Duet COMBINED LOG AND ECHO SOUNDER

Paddle Bar Replacement

Lectric Cycles Mid-Drive Electric Motor Installation

Air Differentail Pressure Switch

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

QUICK START GUIDE CB-450 DATA BUOY PLATFORM

2012-June-12 SECOND DRAFT Hobie Getaway Spinnaker Installation Instructions

Pre-Paint>Fuselage>Empennage>Fit vertical tail fin. Objectives of this task: Materials and equipment required: Fit the spar extender

Pressure Dump Valve Service Kit for Series 3000 Units

A. TO PREPARE THE MACHINE FOR USE.

Model VR6 System. Installation, Operation & Maintenance

ASSEMBLY MANUAL HOBIE CATSY

DESIGNED AND MANUFACTURED IN ENGLAND CLIPPER DEPTH DEPTH METRES ECHO SOUNDER.

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

Santa Fe Cycles Assembly Guide Introduction

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

PURA. Pure Gas Dewpoint Transmitter. Users Guide

INSTRUCTION MANUAL. January 23, 2003, Revision 0

QUICK START GUIDE CB-150 DATA BUOY PLATFORM

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

SECTION 2 RING MOUNT

ACV-10 Automatic Control Valve

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

SR MARINER DIGITAL DEPTH METER DDM- 1 DDM- 2 INSTALLATION INSTRUCTIONS

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

You have decided to buy an LP 10 E by STEYR SPORTWAFFEN the new dimension of match air pistols!

1.0 - OPENING AND CLOSING THE DOOR

Met One E-BAM Particulate Monitor

DM-RD (English) Dealer s Manual. ROAD Rear Derailleur RD-9000 RD-6800 RD-5800 RD-4700

User Manual. MEGP 25 Electric Gripper. Document version: 1.1

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

Bolt. enmey Body Assembly. Bolt Sleeve. Bolt Stop. enmey TM PARTS GUIDE Rev 1.3 Page 2. OM7010 Bolt Tail O-rings

STEYR evo 10 E STEYR evo 10 E Compact

1200B2 Series Service Regulators. Instruction Manual

DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D

UsER manual for Watersens ph -REDOX

Agilent 1220 Infinity II LC Mobile Upgrade Kit

IP65 Air Differential Pressure Switch

HALYARD EXITS, CLEATS, CLUTCHES, WINCH PADS, HANDLE POCKET

CHAPTER 2 MAINTENANCE

Maintenance Manual. Note: This document is broken up into the following 6 sections of prescribed maintenance.

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Installation Instructions

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

User s Manual. Revision 1.0. Copyright 2011 Maretron, LLP All Rights Reserved

2-jaw self-centering pneumatic parallel gripper (series SX)

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

User s Guide. Pressure Controller for liquid delivery systems

Wellhead Mast. Installation and Operation Guide. Nanometrics Inc. Kanata, Ontario Canada

User s Guide. Vacuum Controller for liquid delivery systems

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

INSTALLATION INSTRUCTIONS

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

AREA VALVE SERVICE UNITS

Variable Area Flow Meters

C-Flow Coriolis Mass Flow Meters

SHEET 2: VERTICAL INSTALLATION

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

Plankton pump Model ,2 KWatt. Manual. KC Denmark. Research Equipment Limnology Oceanography Hydrobiology

Installation and Maintenance Manual. Compact Medical Gas Outlets

Unisense In Situ UniAmp Connector System

Installation and Training Manual

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE

USER INSTRUCTIONS. NAF Duball DL Ball Valves. Installation Operation Maintenance. Experience In Motion. flowserve.com

444C DUAL PERFORMANCE VALUE PACK

Gripping rotary modules

4400 TwinHybrid Gas Seal

Type PRX/120, PRX/125, PRX-AP/120, PRX-AP/125, PRX/181, PRX/182, PRX/131 and PRX-AP/131 Pilots

Mass Flow Meter (MFM) for Gases

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

DM-RARD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Rear Derailleur DURA-ACE RD-R9100 ULTEGRA RD-R8000

Transcription:

Depth sensor Product reference : 90-60-456 REV 1 USER GUIDE and INSTALLATION GUIDE nke Sailing competition Z.I. Kerandré Rue Gutenberg 56700 HENNEBONT- FRANCE http://www.nke.fr After sale service n 33 297 365 685

TABLE OF CONTENTS 1 USING... 3 1.1 PRESENTATION... 3 1.2 LIST OF CHANNELS DISPLAYED... 4 1.3 ALARMS SETTING... 4 1.4 FILTERING OF THE CHANNELS... 4 1.5 CHOICE OF THE UNIT... 4 1.6 TECHNICAL SPECIFICATIONS... 5 2 SENSOR CALIBRATION... 5 2.1 PRINCIPLE OF CALIBRATION :... 5 2.2 OFFSET SETTING PROCEDURE (BY DEFAULT THE OFFSET VALUE IS 0.00) :... 5 3 INSTALLATION... 6 3.1 PACKING LIST... 6 3.2 LIST OF ACCESSORIES... 6 3.3 SPECIFIC TOOLS REQUIRED FOR THE INSTALLATION... 6 3.4 CHOICE OF THE LOCATION... 6 3.5 INSTALLATION OF THE THROUGH-HULL... 9 3.6 INSTALLATION OF THE DEPTH-FINDER SENSOR... 10 3.7 INSTALLATION OF THE SAFETY WIRE... 10 3.8 ELECTRICAL CONNECTION... 11 4 MAINTENANCE... 11 4.1 RECOMMENDATIONS... 11 4.2 AT PORT, HOW TO REMOVE THE SENSOR FROM THE THROUGH-HULL?... 11-2 - Depth sensor guide 33-60-012-001

1 USING 1.1 Presentation The depth-finder sensor is fitted via a through-hull. It can be removed via the through-hull. It is connected to the depth-finder log interface of your TOPLINE installation. This sensor provides the information on depth. Architecture of the installation TL 25 BOAT SPEED 16.85 KNOTS APP WIND A 105- DEGRES 10.50 DEPTH METERS nke input NMEA NMEA + NMEA - Cable TOPLINE 20-61-001 GND DATA black 12VDC white log depth interface 90-60-450 connecting box 90-60-417 Figure 1 log depth speedomètre IMPORTANT - Some products, for cleaning, painting or other, contain powerful solvents, which can severely damage the plastics and O-rings of the sensors. - Plastic through-hulls are recommended for assembly on hulls made of fibre, aluminium or metal. For assembly on a wood hull, use a bronze through-hull. - The sensor is equipped with a 6 meter cable, with a moulded waterproof connector at its end : do not cut this cable, as this would reduce the characteristics and reliability of the sensor. - For channels settings, please refer to the guide of your TOPLINE display. - 3 - Depth sensor guide 33-60-012-001

1.2 List of channels displayed The depth-finder sensor, connected to the TOPLINE bus of your installation, automatically creates the channels below. They are accessible using the displays of the TOPLINE range. Channel Display Unit Depth Depth 10.0M meter or foot 1.3 Alarms setting The setting of an alarm enables you to monitor the value of a channel. When the preset threshold is exceeded, a warning message is displayed and an audible alarm is activated. For example, you can set an upper threshold and a lower threshold on the depth channel. The upper alarm is activated when the display is higher than the programmed threshold. The lower alarm is activated when the display is lower than the programmed threshold. To cancel the alarm of a channel, enter the value 0 in the upper alarm and the lower alarm. Thus, the setting of an alarm on the depth channel will allow you to monitor the water depth effectively. To activate alarms, please refer to the user guide of your display. 1.4 Filtering of the channels The level of filtering of a channel determines the frequency of update of the data displayed. Filtering is adjustable between 1 and 32, and the default value is 8. The lower this value, the higher the frequency of update. Please refer to the user guide of your display to carry out the filter setting. 1.5 Choice of the unit You have the option to choose the following display units : - Depth : in meters or in feet. Please refer to the user guide of your display to carry out this change of units. - 4 - Depth sensor guide 33-60-012-001

1.6 Technical specifications - Tightness of the sensor : IP67-6 meter cable fitted with a moulded connector. - Weight : 700 g - Operating temperature : -10 C to +50 C - Storage temperature : -20 C to +60 C - Depth range : controlled up to 50 meters 2 SENSOR CALIBRATION Every nke sensor is adjusted at the factory. However, a calibration is required to adapt to the specificities of your ship and to obtain an optimum measurement accuracy. Follow the calibration procedure below, by visualising the settings on a display. To perform these settings, please refer to the user guide of your display. 2.1 Principle of calibration : By default, the depth-finder indicates the height of water between the sensor and the seabed. You can also adjust the offset of your depth-finder to display the depth : A B Figure 2 Either between the water surface and the seabed. Or between the bottom of the keel and the seabed. 2.2 Offset setting procedure (by default the offset value is 0.00) : 1. Select the sub-channel offset calib of the channel surface speed, 2. enter a negative offset A, to display the depth beneath the keel, 3. or enter a positive offset B, to display the depth in relation to the water surface. 4. validate by pressing the enter key. The new setting will be saved to the memory. - 5 - Depth sensor guide 33-60-012-001

3 INSTALLATION 3.1 Packing list The installation kit includes : - the sensor, equipped with a 6 meter cable and a waterproof connector, - the through-hull fitting and its nut, - one seal, - one stopper, - one tube of silicon grease and one safety wire. 3.2 List of accessories - Depth-finder sensor only : 90-60-462 - Depth-finder through-hull fitting kit, stopper and tube of silicon grease : 31-35-002 3.3 Specific tools required for the installation The drilling of the hole for the through-hull fitting is performed using a Ø 51mm crown saw drill bit fitted with a guide pin. 3.4 Choice of the location The choice for the location of the depth-finder sensor is crucial to achieve optimal performances. Turbulences caused by the water flow under the ship can significantly disrupt the operation of the depth-finder. The sensor must be : - as vertical as possible, not more than 10 off th e vertical, - as close as possible to the axis of the ship, - sufficiently far from the keel, - always immersed, no matter what the heel, - away from any source of electrical disturbance, - accessible so it can be cleaned from the inside of the ship. It is imperative that the water streams get to the sensor unperturbed. On a sailing boat : the ideal position of the sensor is in front of the keel, along the axis of the ship. - 6 - Depth sensor guide 33-60-012-001

The depth sensor results can be disturbed by the keel of the boat. Install the sensor at a distance higher than half the height of the keel. Sensor D L Location of the sensor 3 Distance D (metre) 2,5 2 1,5 1 0,5 0 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 Length of the keel (metre) Figure 3 : recommended location - 7 - Depth sensor guide 33-60-012-001

On a motorboat : the sensor must be approximately 50 cm back from the squat limit. It may be necessary to prepare a 10 to 15 mm streamlined plate so that the sensor is located beyond the turbulent water layers. Figure 4-8 - Depth sensor guide 33-60-012-001

3.5 Installation of the through-hull Once the location of the sensor is determined, follow the procedure below : - From the inside of the ship, drill the pre-drilling hole, then from the outside, drill a 51 mm diameter hole using the crown saw. - Degrease the hull. - Coat the flange of the through-hull fitting with sealing paste. Place the through-hull in position. - Inside the ship, lay some sealing paste around the through-hull. - Position the though-hull fitting by orienting the fool proofing notch towards the bow of the ship (see figure 4). Similarly, on the outside of the through-hull fitting, an arrow indicates the orientation : position this arrow towards the bow of the ship. - Screw the nut and tighten moderately. - Grease the stopper and screw it onto the through-hull fitting. - Leave to dry for over 12 hours. Paddlewheel Cap nut Housing Safety wire Washer Hull Marine sealant Figure 5 Note : a flat joint is delivered with the through-hull fitting, to ensure the watertightness between the hull and the through-hull fitting. However, mounting this joint is not compulsory. For a more reliable watertightness with time, we recommend you use sealing paste only. - 9 - Depth sensor guide 33-60-012-001

Caution : in case a triducer sensor (log and depth finder in one single sensor) is used at a later stage, the axis of the through-hull must imperatively be parallel to the lubber line of the ship. Through hull axle Boat axle Figure 6 3.6 Installation of the depth-finder sensor - Grease the two O-rings of the sensor with the silicon lubricant. - Introduce the sensor in the through-hull. - Tighten the sensor nut slightly. - Then rotate the body of the sensor to position the fool proofing notch in its slot. - Manually tighten the nut, to the thread root. Antifouling : the immersed surfaces of the depth-finder sensor will rapidly become covered with algae and seashells. Protect these surfaces using a thin coat of antifouling to guarantee the performance of your instruments. Caution : - Do not introduce the sensor in the through-hull without lubrication, as it may damage the seals. 3.7 Installation of the safety wire The safety wire allows to block the nut of the sensor in rotation. Install the safety wire according to the indications on figure 5. - 10 - Depth sensor guide 33-60-012-001

3.8 Electrical connection The sensor is equipped with a 6 meter cable and a moulded waterproof connector. You will connect the depth-finder sensor onto the depth sensor connector socket of the depth-finder log interface housing. Caution : - To guarantee the watertightness of the connectors, make sure they are properly screwed onto their connector socket. - The connection of the sensors must be performed with the installation power switched off. 4 MAINTENANCE 4.1 Recommendations - The sensor is coated with silicon grease. It is however recommended to lubricate it regularly (silicone grease only) in order to avoid locking in the through-hull. - The immersed surfaces of the depth-finder sensor will rapidly become covered with algae and seashells. Periodically clean the immersed surface of the sensor. If you do not use your instruments for a long period of time, remove the sensor from the through-hull and place a stopper. 4.2 At port, how to remove the sensor from the through-hull? To perform maintenance and cleaning operations, it is necessary to remove the sensor from the through-hull, when the ship is afloat. The sensor must be retrieved, then the hole of the through-hull must be blocked with the stopper. This operation may seem difficult, because water comes into the ship. However, with a bit of method and organisation, it can be performed easily. Only a few decilitres of water will come inside the ship. Procedure : 1. Clear the area around the sensor. 2. Lubricate the stopper and keep it within your reach. 3. Unscrew the sensor nut entirely. 4. Progressively retrieve the sensor, and be ready to block the through-hull with the stopper. 5. As soon as the sensor is removed, block the hole of the through-hull with the stopper, and screw. 6. Only a few decilitres of water will come inside the ship. - 11 - Depth sensor guide 33-60-012-001

NOTES - 12 - Depth sensor guide 33-60-012-001

NOTES - 13 - Depth sensor guide 33-60-012-001