THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Similar documents
THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-210 SERIES. Operating and Service Manual. Series includes all variants of HF-210/211. Issue A October 2014 *Section 6.

Operation Manual Piston Sensed Gas Pressure Regulators

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Engineering Data Sheet

LRS(H)4 Pressure-Reducing Regulator User Manual

MEGR-1627 Instruction Manual

RS(H)20, 25 USER MANUAL

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

RD(H)20/25 Pressure-Reducing Regulator User Manual

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Models: C62/63/64-A/D

Installation, Operation and Maintenance Manual for Back Pressure Regulator

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

1305 Series Pressure Reducing Regulators

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

64 Series Pressure Reducing Regulators

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

MEGR-1912 Instruction Manual

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

756 Safety Relief Valves

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

776 Cryogenic Safety Valve

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

WHEATLEY Series 500 Swing Check Valve

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

1805 Series Relief Valves

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

RHPS Series PRV 2 all types of connections User Manual

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

FLANGED MULTI-PORT BALL VALVES

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Anti-flood device Model B-1

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

1200B2 Series Service Regulators. Instruction Manual

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

CAST IRON SAFETY VALVE TYPE 6301

OPERATING AND MAINTENANCE MANUAL

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

TECHNICAL DATA. Q= Cv S

Combination Air Valve

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA. Q = C v P S

Types PT and ETP Dome-Loaded Pressure Regulator Valves

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

RHPS Series PRV 6 User Manual

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

2.0 INSTALLATION & SERVICE

Regulator from 1800 B series

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

453 Series Steam Heated Vaporizing Regulator

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

// ADapters GUIDelines

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Type ACE97 Pad-Depad Valve

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

INSTRUMENTATION VALVES

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

SINGLE STAGE ULTRA-HIGH PRESSURE REDUCING REGULATOR INSTALLATION AND OPERATION INSTRUCTIONS. Certified ISO 9001

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Types S100K and S102K Pressure Regulators

Installation, Operation, and Maintenance Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

1.0 - OPENING AND CLOSING THE DOOR

Anderson Greenwood Series 400 Diaphragm Pilot Operated Safety Relief Valves. Installation and Maintenance Instructions for

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Installation, Operation and Maintenance

Pressure Regulators. Operating Instructions. Instrumentation

WHEATLEY Series 822/820 Swing Check Valve

6301 TYPE CAST IRON SAFETY VALVES

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

MODELS 1500, 1520, 1530, 1560

TECHNICAL DATA. Page 1 of 12

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Transcription:

THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1

TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special Conditions for Safe Use... 5 5. Hazardous Location Usage... 5 6. Servicing and Maintenance... 5 6.1. Servicing the BP-LF691 (High Pressure 10mm Sensor Assembly)... 6 6.1.1. Accessing the Main Valve Assembly... 6 6.1.2. Reassembly... 7 6.1.3. Figure 1 Sectional View of the BP-LF691... 8 6.2. Servicing the BP-MF690... 9 6.2.1. Accessing the Main Valve Assembly... 9 6.2.2. Reassembly... 10 6.2.3. Figure 2 Sectional View of the BP-MF690... 11 7. Technical Data... 12 8. Warranty Statement... 12 2

1. Description The BP-690 is a piston sensed Back Pressure Regulator which can be used as a precision relief valve to maintain a constant set pressure within gas or hydraulic systems. The BP-690 series has options for both low flow (LF) and medium flow (MF) rate applications. The housing has been machined from 316 SS to ensure maximum protection against the media on which it will be used, and the environment in which it will be placed. The BP-LF690 regulator incorporates a 2.5mm diameter seat which provides a Cv capacity of 0.1 and the BP-MF690 regulator incorporates a 4.5mm diameter seat which provides a Cv capacity of 0.5. The regulators accurately control inlet pressures of up to 414 bar (6000 Psi) and vent excess pressure back via the outlet connection port. The control on the regulator is set via compression of an adjustable spring. The Model number will contain a G for Gas or an H for Hydraulic depending upon the type of service. As standard the BP-LF690H and BP-MF690H are fitted with 316SS and Hastelloy seats respectively. The BP-LF690H also has an option for ceramic seating which provides ultimate protection against cavitation and erosion on aggressive application media such as water glycol and methanol. For gas applications, PEEK seats are fitted to the BP-LF690G and BP-MF690G as standard. Other seat materials are available for both gas and hydraulic service*. The BP-LF/MF691 option incorporates a specific sensor assembly design which allows for an increased maximum working pressure of 1034 bar (15000 Psi) and greater inlet control pressure of up to 900 bar (13000 Psi). *Please contact the office for further information. 2. Installation Before system start-up, it is recommended that all systems be pressure tested, leak tested and purged with an inert gas such as nitrogen. Check the model number reference to ensure that the pressure range complies with the installation requirements. Visually inspect the regulator for any signs of damage or contamination. If any foreign materials are present and cannot be removed from the regulator, or if the threads on the regulator appear to be damaged, please contact the office immediately to arrange for the regulator to be returned for service. 3

The Inlet and Outlet ports are clearly marked. Select the correct size and type of connection fittings for these ports which are indicated in the regulators part number. Both British Standard Pipe (BSPP) B and National Pipe Thread (NPT) N options are available on this regulator. Use the correct dowty or bonded seal for BSPP connections, self centering seals are recommended. For NPT threads, ensure that PTFE tape is applied correctly to the fittings, applying two overlapping layers in the direction of the thread, taking care that the tape does not come into contact with the first thread. The media supplied to the regulator must be clean. Contamination can damage the seat which may cause the regulator to fail. Filtration suited to the application is recommended upstream of the regulator. Should further assistance or information be required in relation to installation of any Pressure Tech regulator please contact the office, giving reference to the regulators part number and/or serial number. 3. Operation Adjusting the loading spring sets the controlled inlet pressure to the regulator. Pressure exceeding this set value allows the main valve to open and vent off the excess pressure through the seat orifice - until the inlet pressure is equivalent to the loading force set by spring against the pressure sensing element, at which point the Main Valve closes the flow through the seat. Compressing the spring increases the pressure at which the regulator will relieve excess pressure. The BP-690 series may be offered with pressure limiting, pressure locking or pre-set pressure options: Pressure limited regulators are fitted with locknuts on the adjusting mechanism in order to limit the maximum allowable control pressure. Regulators fitted with pressure limiting locknuts will state the limited pressure on the regulator label and this will also be indicated in the part number. Pressure locking regulators are fitted with a locking cap which may be set (when specified) to pre-determined requirements. It is secured in place by three M5 grub screws which lock against the bonnet of the regulator creating an anti-tamper device to ensure the pressure cannot be adjusted accidentally. Pre-set pressure regulators are adjusted (factory set) to specified customer requirements within a given pressure range. Both pressure locking and pre-set pressure regulators will be fully adjustable through a given pressure range and the maximum allowable working pressures will be indicated on the regulator label and in the part number. *Note: A table is available on request defining allowable tolerances for set points within a given pressure range. 4

4. Special Conditions for Safe Use The BP-690 series of regulators are classed as Pressure Accessories and not Safety Accessories under the European Directive 97/23/EC, and as such, should be installed with a relief valve to protect the users system from over pressurisation. 5. Hazardous Location Usage This equipment has not been manufactured specifically for use in potentially explosive atmospheres and as such an ignition hazard assessment has not been carried out on this product. If the user should wish to use this product in such an environment where there may be a potentially explosive atmosphere then it is the responsibility of the user to conduct an ignition hazard assessment against 99/92/EC. 6. Servicing and Maintenance Servicing and maintenance work on the BP-690 regulators should only be performed after fully reading and understanding the Operating and Servicing Manual. Due to the typical nature of the gases the regulator can be used with, the operator should not endanger himself/herself or others by working on this regulator without prior knowledge on the Health and Safety concerns relating to handling of technical gases. Any uncertainty should be clarified with Pressure Tech before working on the regulator. Pressure Tech Ltd recommends the use of Krytox GPL 205 during servicing. Prior to commencing service, please ensure that: - The equipment has been de-pressurised - The load spring has been de-compressed by turning the adjusting mechanism fully anti-clockwise - Applications involving toxic, flammable or corrosive media have been fully purged To ensure the best possible results from servicing, when re-assembling the regulator and any assemblies within it, ensure that all areas of the components and the regulator body are cleaned and free from contaminants which may result in failure of the regulator. 5

6.1. Servicing the BP-LF691 (High Pressure 10mm Sensor Assembly) *Note: fig 1 should be used as a reference for the following set of instructions 6.1.1. Accessing the Main Valve Assembly i. Remove the securing grub screw (2) from the regulator body (14). ii. Unscrew the pan screw (3) and remove the name plate (23) from the hand wheel (22). iii. Unscrew the locknut (26) and remove the hand wheel (22) from the adjusting screw (19). iv. With the regulator secured up-right in a vice, remove the bonnet (17) by using a torque wrench or equivalent with 47mm open end. v. Un-screw and lift the top works from the assembly, inclusive of the bonnet (17), load spring (18), adjusting mechanism (1, 19, 20 and 21) and spring rest (11). vi. The sensor assembly (8, 9, 10a, 10b and 15) can be removed from the body by using pliers*. *An M5 mounting point is located in the sensor holder (15) which can be used along with an appropriate screw to remove the assembly to avoid causing any damage to the sensor (10b). vii. Remove the sensor (10a, 10b) from the sensor holder (15) and inspect and replace the o-rings (6, 7, 24 and 25) as required. viii. Secure the flats on the sensor (10b) in a vice (with the main valve (8) pointing upwards) and using a 17mm long socket, open ended spanner or adjustable, loosen the main valve retainer (10a) from the sensor (10b) and remove together with the main valve (8). ix. Inspect the main valve (8) for any defects or damage to the sealing edge and replace as required. x. Using a 22mm socket, remove the seat retainer (13) from the regulator body (14) and remove the seat (12) and o-ring (5). xi. Inspect the seat (12) for any defects or damage to the sealing edge and replace the seat (12) and o-ring (5) as required. 6

6.1.2. Reassembly i. Place the o-ring (5) into the bore in the bottom of the regulator body (14). ii. Position the seat (12) into the same bore ensuring that the o-ring groove on the outer diameter of the seat is facing downwards towards the o-ring (5). iii. Screw the seat retainer (13) into the regulator body (14) and tighten to 20Nm to secure the seat (12) using a torque wrench and 22mm socket. iv. Place the main valve (8) into the main valve retainer (10a) and position the main valve spring (9) onto the valve stem. v. With these parts in place, screw the sensor (10b) into the main valve retainer (10a). To tighten, secure the flats on the sensor (10b) in a vice and use a 17mm long socket, open ended spanner or adjustable on the main valve retainer (10a). vi. Locate the sensor (10b) into the sensor holder (15) and then place the sensor assembly into the regulator body (14) ensuring that the main valve (8) locates into the seat retainer (13). vii. Where necessary, reassemble the top works by placing the adjusting mechanism (1, 19, 20 and 21), load spring (18) and spring rest (11) into the bonnet (17). viii. Screw the bonnet with top works into the regulator body (14) and using a 47mm torque wrench, tighten the bonnet to approximately 90 100 Nm. ix. Fit the M3 grub screw (2) to secure the bonnet (17). x. Place the hand wheel (22) onto the adjusting screw (19) and screw and tighten the lock nut (26). xi. Secure the nameplate (23) with the M3 pan screw (3). To ensure that the main valve assembly has been correctly and effectively installed it may be required to perform the appropriate seat leak test as per ANSI/FCI 70-2. 7

20 (180) SECTION A-A 6.1.3. Figure 1 Sectional View of the BP-LF691 Ø75 54 23 22 18 17 C INLET OUTLET C 3 26 1 21 20 19 ITEM 1 2 3 4 5 6 7 8 9 10 a 10 b 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 PARTS LIST PART NUMBER DESCRIPTION BEAR-51103-SS 51105 SS BEARING FIT-M3-06-A4-SKT-CON-SET SET SCREW FIT-M3-08-A4-70.0-SKT-BTN SCREW OR-0350-20 OR-0090-10 OR-0096-24 OR-0420-20 PT-BP-550-003-002 MAIN VALVE PT-BP-550-004 MAIN VALVE SPRING PT-BP-691-002 MAIN VALVE RETAINER PT-BP-691-001 10mm SENSOR PT-C-095-001 SPRING REST - DOME PT-BP-550-002-008 SS316 SEAT PT-BP-550-001 RETAINING SEAT NUT PT-BP-691-N-LF-03A-001 BODY - N PORTING PT-BP-691-003 10mm SENSOR HOLDER PT-BP-550-022 SLIDE RING PT-C-040 BONNET SPR-G40X51 LOAD SPRING PT-C-043-004 ADJUSTING SCREW PT-C-045 ADJUSTING NUT PT-C-046 SCREW PT-C-048-001 LARGE NYLON HAND WHEEL PT-C-049 NAMEPLATE ORB-PT-C-207 PTFE BACK UP RING ORB-PT-C-139 PTFE BACK UP RING PT-C-132 LOCK NUT Ø65 11 4 B 2 10 b 16 DETAIL B SCALE NTS 24 DETAIL C SCALE NTS 7 25 9 6 14 C 15 13 10 a 8 12 5 Ø95 50 A/F 8 Copyright of Pressure Tech Ltd

6.2. Servicing the BP-MF690 *Note: fig 2 should be used as a reference for the following set of instructions 6.2.1. Accessing the Main Valve Assembly i. Remove the securing grub screw (2) from the regulator body (14). ii. Unscrew the pan screw (3) and remove the name plate (23) from the hand wheel (22). iii. Unscrew the locknut (26) and remove the hand wheel (22) from the adjusting screw (19). iv. With the regulator secured up-right in a vice, remove the bonnet (17) by using a torque wrench or equivalent with 47mm open end. v. Un-screw and lift the top works from the assembly, inclusive of the bonnet (17), load spring (18) and adjusting mechanism (1, 19, 20 and 21). vi. The sensor assembly (8, 9, 10a, 10b, 11 and 15) can be removed from the body by using pliers. vii. Secure the spring rest (11) in a vice (with the main valve (8) pointing upwards) and using a 16/20mm open ended spanner (assembly dependant) or adjustable, loosen from the sensor (10) but do not remove completely. viii. Take the sensor assembly from the vice and with the main valve (8) pointing downwards, remove the spring rest (11) from the assembly. ix. Inspect and replace the o-ring (4) from around the spring rest (11) as required. x. The main valve (8) and valve spring (9) can now be removed from the sensor (10). xi. Remove the sensor (10) from the sensor holder (15) and inspect and replace the o-rings (6, 7, 24 and 25) as required. xii. Inspect the main valve (8) for any defects or damage to the sealing edge and replace as required. xiii. Using a 22mm socket, remove the seat retainer (13) from the regulator body (14) and remove the seat (12) and o-ring (5). xiv. Inspect the seat (12) for any defects or damage to the sealing edge and replace the seat (12) and o-ring (5) as required. 9

6.2.2. Reassembly i. Place the o-ring (5) into the bore in the bottom of the regulator body (14). ii. Position the seat (12) into the same bore ensuring that the o-ring groove on the outer diameter of the seat is facing downwards towards the o-ring (5). iii. Screw the seat retainer (13) into the regulator body (14) and tighten to 20Nm to secure the seat (12) using a torque wrench and 22mm socket. iv. Locate the sensor (10) into the sensor holder (15). v. Place the main valve (8) into the sensor (10) and position the main valve spring (9) onto the valve stem. vi. Screw the spring rest (11) into the sensor (10), secure the flats of the spring rest in a vice and tighten using a 16/20mm open ended spanner or adjustable. vii. Place the sensor assembly into the regulator body (14) ensuring that the main valve (8) locates into the seat retainer (13). viii. Place the load spring (18) on the spring rest (11). ix. Screw the bonnet with top works into the regulator body (14) and using a 47mm torque wrench, tighten the bonnet to approximately 90 100 Nm. x. Fit the M3 grub screw (2) to secure the bonnet (17). xi. Place the hand wheel (22) onto the adjusting screw (19) and screw and tighten the lock nut (26). xii. Secure the nameplate (23) with the M3 pan screw (3). To ensure that the main valve assembly has been correctly and effectively installed it may be required to perform the appropriate seat leak test as per ANSI/FCI 70-2. 10

31 (195) SECTION A-A 6.2.3. Figure 2 Sectional View of the BP-MF690 Ø75 23 A INLET OUTLET A 3 26 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27* PARTS LIST PART NUMBER DESCRIPTION BEAR-51103-SS 51105 SS BEARING FIT-M3-06-A4-SKT-CON-SET SET SCREW FIT-M3-08-A4-70.0-SKT-BTN SCREW OR-0070-10 OR-0100-10 OR-0120-20 OR-0460-20 PT-BP-550-003-002 MAIN VALVE PT-BP-550-004 VALVE SPRING PT-BP-550-005-002 SENSOR PT-BP-550-007-005 SPRING REST PT-BP-550-010-001 HASTELLOY SEAT PT-BP-550-011-001 SEAT NUT PT-BP-MF690-05-N-08N-D PT-C-032-007 PT-C-037 PT-C-040-009 PT-C-041-004 PT-C-043-004 PT-C-045 PT-C-046 PT-C-048-001 PT-C-049 PT-C-051 PT-C-115 PT-C-132 PT-C-180 BODY - N PORTING SENSOR HOLDER SLIDE RING BONNET LOAD SPRING ADJUSTING SCREW ADJUSTING NUT SCREW LARGE NYLON HAND WHEEL NAMEPLATE BACK UP RING BACK UP RING LOCK NUT PROTECTIVE SLEEVE 22 1 * SOLD AND ORDERED SEPARATELY 21 DETAIL B SCALE NTS Ø54 18 27* 20 19 16 4 17 24 2 6 9 11 10 Ø65 25 8 7 14 B 15 DETAIL C SCALE NTS C 13 8 12 5 Ø65 80 A/F 11 Copyright of Pressure Tech Ltd

7. Technical Data Fluid Media: Max Inlet Pressure: Pressure Control Range: Operating Temperature: Materials: Flow Capacity (Cv): Leakage: All gases and liquids compatible with materials of construction 550 bar (BP-690) 1034 bar (BP-691) 5-414 bar (BP-690) 5-900 bar (BP-691) -20 C to +80 C Body and Trim: 316 SS Seat Gas: PEEK Seat Hydraulic: 316SS/Hastelloy/Ceramic Main Valve: 718 Alloy 0.1 (BP-LF690/691) 0.5 (BP-MF690/691) Gas: Bubble tight Hydraulic: Zero drops of water at max inlet 8. Warranty Statement Pressure Tech Ltd guarantee all products correspond with their specification at the time of delivery and, with exception to wear and tear, wilful damage, negligence, and abnormal working conditions, will be free from defects for a period of 12 months from date of delivery. 12