Evaluation of Hydropath Clearwell Technology On Carbonate Brine Scaling Using Tube Blocking Method

Similar documents
Installation Operation Maintenance

Reverse Osmosis System Installation Guide and Operation Manual.

Fisher DVI Desuperheater Venturi Inline

Joint industry project on foam

HydroPull. Extended-Reach Tool. Applications

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

W I L D W E L L C O N T R O L FLUIDS

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Constant Pressure Inlet (CCN) Operator Manual

John Downs Cabot Specialty Fluids SPE European Formation Damage Conference

PARTICLE PLUGGING APPARATUS TESTING OF BRIDGING MATERIALS IN A CEMENT SLURRY

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

1 Scope... 2 Functions of cementing float equipment... 3 Definitions... 4 Calibration... 5 Test Categories... 6 General...

16. Studio ScaleChem Calculations

Natural Gas Conditioning Skids & Equipments

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

PRODUCT DATA SHEET. Description

AN INNOVATIVE APPROACH TO OPTIMIZE REVERSE OSMOSIS MEMBRANE PERFORMANCE

OLGA. The Dynamic Three Phase Flow Simulator. Input. Output. Mass transfer Momentum transfer Energy transfer. 9 Conservation equations

Chapter 8: Reservoir Mechanics

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Air Operated Hydraulic Pumping Systems to 50,000 psi

Permeability. Darcy's Law

Plunger Fall Velocity Model

1805 Series Relief Valves

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

Lost Circulation Material Evaluation Receiver Instruction Manual

Next Generation Quartz Pressure Gauges

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

Model Series 62 Constant Differential Relay

TECHNICAL BULLETIN CRYOGENIC APPLICATION SERVICES. website:

E NGINEERED C EMENTING S OLUTIONS

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve

Pasquale Imbò e Marco Pelucchi ENI S.pA;

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Drilling Efficiency Utilizing Coriolis Flow Technology

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Calcimeter Instruction Manual

SPE Copyright 2000, Society of Petroleum Engineers Inc.

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Bridge Plugs, Ball Drop & Caged Ball Plugs For Zone Isolation

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Coal Bed Methane (CBM) Permeability Testing

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Technical Topics. Softener Elution Studies TT

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Hydraulic Piston Pump Field Trial

Test Report # Rev 0. Adiabatic Compression With Constant Bleed Valve

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

THE CSIRO S HYDRATES FLOW LOOP AS A TOOL TO INVESTIGATE HYDRATE BEHAVIOUR IN GAS DOMINANT FLOWS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Heat Pump Connections and Interior Piping

OVERVIEW pg 3. Major Points to Consider pg 3 Minor Points to Consider pg 3. INSTRUCTIONS pg 4

PROCEDURE TWO-PLY TESTABLE BELLOWS D 1 OF 5 TWO PLY BELLOWS TEST PROCEDURE

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Flow in a shock tube

WW-730. Pressure Sustaining/Relief Control Valve

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

PH01 Perfusion Cannula Manual

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

MMS Mercury Monitoring System for Natural Gas

Intermittent Gas Lift Utilizing a Pilot Valve

OREGON HEALTH. Systems Public Water Supply Systems Community Water Supply Systems Source Water Protection

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Modeling Case Study: Surge Tanks, Valves, Level sensors, and modeling

SEMATECH Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Instruction Manual Updated 7/26/2011 Ver. 2.2

Memo. Shelley Cohen. From: Bill Dickson CC: Date: February 5, 2015 Re: Editorial Oil & Gas News

1800CPB2 Service Regulators

Experiment 8: Minor Losses

Smart Water Application Technologies (SWAT)

Is Lime Souring Your Valve Operation?

Model 4000 Pressure Controller

TROUBLESHOOT ROD PUMPED WELLS USING TUBING FLUID LEVEL SHOTS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Downhole Diverter Gas Separator

Steam penetration in steam sterilization processes

2.0 INSTALLATION & SERVICE

64 Series Pressure Reducing Regulators

Simposium Nasional dan Kongres X Jakarta, November 2008 Makalah Profesional IATMI

Sandy Hook #1: Produced Water Volume Inversion

Low-Flow Purging Procedure with MicroPurge basics Equipment. MP10 Bladder Pump Controller MP15 Control. MP30 Drawdown Meter.

1805 Series Relief Valves

Materials Performance November Nitrogen generator inhibits corrosion within fire protection systems

HYDROSTATIC LEAK TEST PROCEDURE

FRYSAFE COOKING OIL FILTRATION I&O MANUAL

Pigging as a Flow Assurance Solution Avoiding Slug Catcher Overflow

Water Balance Indexes Revised September 2017

MET 335W Fluid Mechanics Laboratory. Lab 1: Bourdon Tube Calibration. Nick Peak

Use equation for the cylindrical section and equation or for the ends.

CHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS

Pressure Test Tubing for Leak

Plunger Fall Velocity Model

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

HumiSys HF High Flow RH Generator

Transcription:

Flow Assurance R-4-319 November 24 Evaluation of Hydropath Clearwell Technology On Carbonate Brine Scaling Using Tube Blocking Method Final Report Authors: S. Brown & J. Rohan Work By: J. Rohan Westport Technology Center International 67 Portwest Drive Houston, Texas 7724 (713) 479-84 (713) 864-9357 (Fax) www.westport1.com Prepared for Halliburton Energy Services W.O.# Westport Technology Center International makes no representations or warranties, either express or implied, and specifically provides the results of this report "as is" based on the information provided by client.

Table of Contents Page 1. INTRODUCTION 1 2. EXPERIMENTAL PROCEDURE 1 3. MATERIALS 2 4. TEST PROCEDURE 2 5. RESULTS 2 6. CONCLUSIONS AND RECOMMENDATIONS 4 APPENDIX (Diagram of Tube Blocking Apparatus) 1 List of Tables and Figures Page Figure 1, Calcite Scaling Test #1 (Without Clearwell Instrument) 5 Figure 2, Calcite Scaling Test #2 (With Clearwell Instrument) 6 Figure 3, Calcite Scaling Test #3 (With Clearwell Instrument) 7 Figure 4, Calcite Scaling Test #4 (Without Clearwell Instrument) 8 Prepared for Halliburton Energy Services R-4-319 Page i

1. INTRODUCTION Westport Technology Center has been asked to perform a laboratory study evaluating the effectiveness of the Hydropath Clearwell instrument in reducing scale deposition and plugging. Previous industry studies have been performed and give guidance to test methods and the parameters that influence scaling rates in a pipe. Several of these parameters are listed below; Scale frequently appears due to a ph change in the fluid as well as an increase in the saturation index of carbonate minerals, shear force effects scaling rates as fluid velocity increases, and, effect of scale inhibitors. Westport has the capability to perform scaling studies for scale inhibitor evaluation using the tube blocking method. 2. EXPERIMENTAL PROCEDURE Tube Blocking Method for Scale Rates A well-developed method for determining scaling rates is the tube blocking method. This test method is appropriate for evaluating the effectiveness of the Hydropath Clearwell product in the reduction or elimination of scale deposition and plugging. The method uses two fluids; one having anionic scaling ions (e.g. HCO 3 ), and the other containing cationic scaling ions (e.g. Ca 2+ ). Equal amounts of NaCl are added to the test fluids to give them a known salinity. Both fluids are pumped at a constant rate through heated 1/8 OD tube coils inside an oven, which then commingle in a test coil of known length and inside diameter. Pressure drops are recorded on the inlet and outlet of the test coil. A backpressure regulator is used on the outlet of the system to maintain a constant pressure during the test. The duration of the test is based on the amount of time it takes for the test coil to become plugged (not to exceed 24 hours). Our current scale plugging test apparatus can encompass temperatures up to 5 F and pressures up to 75 psig. In published literature, it has been shown that a higher flow velocity can shear scale crystals from the tubing walls and slow down or eliminate scale plugging. Multiple flow rates can be run to determine the effect of flow velocity on scale plugging. Pressure drop data can be used to determine the thickness of the scale layer coating the inside of the tube, if it is assumed that surface coating is uniform. The concentration of scale forming ions as well as the change in the ph of the produced test solution can be monitored throughout the duration of the test if desired, but would require additional apparatus. Prepared for Halliburton Energy Services R-4-319 Page 1

3. MATERIALS Tubing Materials 1/8 Stainless Steel tubing with a.6 ID. Brines Brine A and B compositions listed to produce a calcite scale: Brine A g/kg CaCl 2.2H 2 O 36.87 NaCl 138.9 Brine B g/kg NaHCO 3 1.5 4. TEST PROCEDURES Calcite Scaling Brine 1/8 OD Coils Testing was performed in 1/8 OD stainless steel coils with and without using the Hydropath Clearwell instrument. These tests were performed at approximately 125 F and 18 psig. A.5 ml/min rate of injection of the calcite scaling brines through the 1/8 OD (.6 ID) preheating coils produced a 1. ml/min injection rate through the test coil. The pressure limit on the injection pump was set at 5 psig. Pressure differential was measured across the test coil using a Heise PM1 digital pressure gauge with a pressure limit of 75 psig. Once flow had been initiated through the coils, the test was allowed to run until the test coil plugged or a maximum time of twenty four hours was reached. Upon completion of the initial scaling test without the Hydropath Clearwell instrument, all coils were thoroughly cleaned with 1% HCl to remove any calcite scale that had precipitated. The system was then setup to run the tube plugging test using the Hydropath Clearwell instrument. 5. RESULTS Calcite Scaling Brine 1/8 OD Tubing without Hydropath Clearwell Instrument (Test #1) Complete plugging of the tubing material never took place. However, a significant amount of scale being deposited in the test coil was apparent by the steady increase in differential pressure up to 3 psig. The test was stopped and the system flushed with 1% HCl overnight to ensure the removal of the carbonate scale. Prepared for Halliburton Energy Services R-4-319 Page 2

Results of the initial scale plugging test using calcium scaling brines, conducted without the Hydropath Clearwell instrument, are presented in Figure 1. Calcite Scaling Brine 1/8 OD Tubing with Hydropath Clearwell Instrument (Test #2) A second test was performed using the Hydropath Clearwell instrument to determine the effect it had on scale deposition and plugging. Modifications of the test apparatus were needed to ensure that the stainless steel tubes were not in contact with each other or any grounding source that would inhibit the signal transfer of the instrument. There was a pressure buildup (2psig) and release after about 1 hours followed by a large pressure buildup to 5psig, which caused the injections pumps to shut down. However upon disassembly, it was found that the plugging was in the 1/8 stainless steel cross (mixing head) used to connect the two preheating coils to the test coil. This plugging was theorized to be from the static section of the fitting to which the pressure transducer was connected to (there is no flow through the pressure transducer line or the sensor itself). NOTE: This technology does not stop scale production, but rather causes the scale particles to stay suspended in the flowing media and not adhere to pipe surfaces. The 1/8 OD stainless steel tube was flushed with fresh water using a small pump with a low pressure limit (2 psig) and was found to contain only small crystals that were not significant enough to have caused plugging in the tubing. Modifications of the test rig s plumbing were made to ensure there were no dead areas in the flowing system and a second screening of the Hydropath Clearwell instrument was performed in Test 3. Results of the initial scale plugging test conducted with the Hydropath Clearwell instrument using calcium scaling brines is presented in Figure 2. Calcite Scaling Brine 1/8 OD Tubing with Hydropath Clearwell Instrument (Test #3) Pressure response data from the second screening test using the Hydropath Clearwell instrument indicated only one rapid increase in pressure differential (8 psig) at approximately 6 minutes. This pressure spike could have been from scale crystals becoming trapped in a tight bend of the 1/8 OD tubing or at a small orifice at the outlet of the mixing coil. The pressure increase lasted for approximately 3 minutes before releasing. Once the scale crystals had cleared the tube the pressure differential decreased sharply to 1.78 psig where it remained until the conclusion of the test, 24 hours. Results of the second scale plugging test conducted with the Hydropath Clearwell instrument using calcium scaling brines is presented in Figure 3. Calcite Scaling Brine 1/8 OD Tubing without Hydropath Clearwell Instrument (Test #4) An additional test was performed without the Hydropath Clearwell instrument to ensure plugging of the 1/8 OD coil would occur with the modifications that were made to the test rig after Test #2. Pressure response data from this test indicated an onset of plugging at approximately the same time duration as the initial test without the Hydropath Clearwell instrument. Results of the second scale plugging test conducted without the Hydropath Clearwell instrument are presented in Figure 4. Prepared for Halliburton Energy Services R-4-319 Page 3

6. CONCLUSIONS AND RECOMMENDATIONS This initial screening of the Hydropath Clearwell Technology was performed to rapidly gain information on the ability of the apparatus to prevent scale buildup. The tube plugging test is a very critical test for determination of scaling potential from the commingling of two brines (i.e. injection water and formation brine). Basically, if two brines are incompatible and precipitate scale particles the small ID of the coil will cause a pressure increase and possible total blockage. Total blockage or pressure buildup will occur from a bridging of particles or by a true scale buildup on the inside surface. It was decided that this test procedure would be a quick and effective method to evaluate the effectiveness of the Hydropath Clearwell technology without elaborate large flow loop testing. The results from these initial tests indicate that the Hydropath Clearwell technology does in fact have an effect on precipitated scale and its unimpeded flow through a capillary, or pipe. Although some bridging may have taken place it did break and displace from the system. In larger pipe diameter this would not be a factor of concern. The test results are very promising and warrant further investigation of the Hydropath Clearwell technology for its application and financial impact in the oil industry. It is Westport s recommendation that further study be initiated to fully investigate, but not limited to, the following: It is understood that the Hydropath Clearwell technology does not mitigate scale production, but causes the scale particles to stay suspended in the flowing media and thus not deposit on the pipe wall; larger flow loop tests need to be performed to determine pipe wall scale buildup rates (no possibility of particle bridging) without Clearwell and then with Clearwell Other predominate scale species need to be screened, i.e. irons, sulfates, carbonates The ability to clean up previously deposited scales on internal flow line surfaces The ability to function in commingled production (predominate hydrocarbon phase) Effectiveness as a corrosion inhibiting process Effectiveness of inhibiting other solids inherently present in produced fluids (possibly asphaltenes or hydrates) as flow assurance problems Effectiveness as a bacteria inhibiting process Ultimately field trails will be desired to understand the effectiveness of the technology as it transmits through torturous paths and over long distances. Some opinions (internal Westport) were expressed about the ability to transmit without loss of signal through great water depths or through very saline formations typical of the GoM (brines being very conductive and stealing the signal). Prepared for Halliburton Energy Services R-4-319 Page 4

Figure 1 Calcite Scaling Test #1 (without HydropathClearwell Instrument) 6 16 Differential Pressure (psig) 5 4 3 2 1 14 12 1 8 6 4 2 Cumulative Coil Volume Injected 2 4 6 8 1 12 14 16 Elapsed Time (min) Differential Pressure Coil Volume Produced Prepared for Halliburton Energy Services R-4-319 Page 5

Figure 2 Calcite Scaling Test #2 (with Hydropath Clearwell Instrument) 6 16 Differential Pressure (psig) 5 4 3 2 Automatic Pump Shut-off, 5 psig 14 12 1 8 6 4 Cumulative Coil Volume Injected 1 2 2 4 6 8 1 12 14 16 Elapsed Time (min) Differential Pressure Coil Volume Produced Prepared for Halliburton Energy Services R-4-319 Page 6

Figure 3 Calcite Scaling Test #3 (with Hydropath Clearwell Instrument) 6 16 Differential Pressure (psig) 5 4 3 2 1 14 12 1 8 6 4 2 Cumulative Coil Volume Injected 2 4 6 8 1 12 14 16 Elapsed Time (min) Differential Pressure Coil Volume Produced Prepared for Halliburton Energy Services R-4-319 Page 7

Figure 4 Calcite Scaling Test #4 (without Hydropath Clearwell Instrument) 6 16 Differential Pressure (psig) 5 4 3 2 Clearwell Instrument Turned Off (after 3 min) Automatic Pump Shut-off, 5 psig 14 12 1 8 6 4 Cumulative Coil Volume Injected 1 2 2 4 6 8 1 12 14 16 Elapsed Time (min) Differential Pressure Coil Volume Produced Prepared for Halliburton Energy Services R-4-319 Page 8

APPENDIX Diagram of Tube Blocking Apparatus Prepared for Halliburton Energy Services R-4-319 Page 9

Westport Technology - Scale Tube Blocking Method Setup Date: 11-14-4 Drw by: Jeremy Rohan 6 3 8 4 5 7 9 1 2 14 1 1) Brine 1 Pump 2) Brine 2 Pump 3) Brine 1 pre-mixing coil 4) Brine 2 pre-mixing coil 5) Test coil 6) Heise PM1 Digital Pressure Gauge Test Coil Inlet & Test Coil Outlet 7) Produced fluid accumulator 8) Back pressure regulator 9) Scale and graduated cylinder 1) Data acquisition system Prepared for Halliburton Energy Services R-4-319 Page 1