Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Similar documents
THE EXPERT IN LEVEL AND FLOW

THE EXPERT IN LEVEL AND FLOW

Magnetically Controlled Level Gauge. Type: ITA

FLOW MEASUREMENT WITH ORIFICES. Types: BLS500 / BLS550

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Instruction Manual Differential Pressure Transmitter

4/2 way Pneumatic Solenoid Valve

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Instruction Manual Differential Pressure Transmitter

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Tightness control TC. Product brochure GB 3 Edition AGA

DK46 - DK800 Supplementary instructions

Measurement of Low GAS & Liquid Flows

Magnetic level switch type MR783 Instruction Manual

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

Instruction Manual Contact Pressure Vacuum Gauge

Inverse Proportional Pressure-Relief Cart., Size 2 4

Pneumatic pressure switch 20DD

2/2-Way Solenoid Control Valve

Orifice Plate Flow Meter

Tightness controls TC 1 3 and TC 4

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Valvex Valves for Mining Applications

Manual Power relay SR853

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

PRAHER PLC-MP AQUASTAR MANAUL 2009

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Peak Pressure Indicator MSI-3

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

II 2G EEx ia IIC T6. Ignition protection class

Level switches Series LD Vibrating fork level switch for liquids and solids

Autocalibration Systems For In Situ Oxygen Analyzers

Operating Instructions Temperature Measuring System MF420-5T-100

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Inverse Proportional Pressure-Relief Cartridge, Size 10

PGN. Application example. Pneumatic 2-Finger Parallel Grippers Universal Grippers. Gripping force 100 N N. Sizes

GA24 Technical Datasheet

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

DPZ-plus. Application example. Pneumatic 3-Finger Centric Grippers Sealed Grippers. Gripping force 520 N N. Sizes

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Instruction Manual BA90 Precision Barometer

Declaration of Conformity as per Directive 97/23/EC

Gripping modules Pneumatic 2-finger parallel gripper Long-stroke gripper for small components Gripping force 120 N..

C-Flow Coriolis Mass Flow Meters

ATM.ECO - Analog Pressure Transmitter

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Mass Flow Controller (MFC) for Gases

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

SPG. Application example. Pneumatic 2-Finger Parallel Gripper Heavy-load Gripper. Weight 35 kg. Stroke per finger 100 mm.

HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

MANUAL KPS Pressure Control Valve

Automatic Control Unit. Controlmatic E. Type Series Booklet

Monitoring device NTS 30

PFH. Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Sizes Gripping force 510 N N

Level transmitter LT 100

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

PSH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Stroke per finger 14 mm.. 64 mm. Sizes

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

OPTIBAR P 1010 C Technical Datasheet

Instruction Manual Contact Pressure Gauge

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

PSH (inch version) Application example. Pneumatic 2-Finger Parallel Grippers Long-stroke Grippers. Stroke per finger 14 mm.. 64 mm. Sizes 22..

Level switches Series LD Vibrating fork level switch for liquids and solids

Compact pressure switches for gas and air

INSTALLATION & MAINTENANCE INSTRUCTIONS

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

VR46.5V(A)/VR86.5V(A) SERIES

VG5 Supplementary instructions

KSB Delta Compact Type Series Booklet

Automatic Control Unit. Controlmatic E.2. Type Series Booklet

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Mass Flow Meter (MFM) for Gases

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Proportional Throttle Cartridges, Size 16

Gas Pressure Regulator HON 502

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Electronic Turbine Meter TERZ 94

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

SPIROVENT VACUUM DEGASSERS

Dual Solenoid Gas Valve Installation

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Bourdon tube pressure gauge for diaphragm seals

DS MB, MBF THREE PORT VALVES

Pressure independent control valve (PICV) FLOWMATIC

DK48 - DK800. Quick Start. Variable area flowmeter

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Transcription:

Air Purge Unit Series: LSP-compact Type: EJG 2-2 (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014 Headquarters Sales Office BENELUX Intra-Automation GmbH B. V. Intra-Automation HTP Otto-Hahn-Str. 20 PO Box 10 41515 Grevenbroich 4731 AA Oudenbosch GERMANY NIEDERLANDE +49 (0) 21 81 75 66 5 0 +31 (0) 165 322 201 +49 (0) 21 81 6 44 92 +31 (0) 165 322 970 info@intra-automation.de www.intra-automation.com info@intra-automation.nl

LSP compact Installation & Operation Manual Intra-Automation GmbH Intra-Automation GmbH Otto-Hahn-Str. 20 41515 Grevenbroich ba_lsp_compact.en Installation & Operation Manual LSP-compact 11/2014 Technical data subject to be changed. - 1 -

Intra-Automation GmbH Installation & Operation Manual LSP-compact Air Purge Unit Series: LSP-compact Type: EJG 2-2 (Controlled with DigiFlow 515) List of contents Chapt. Content Page 1. Safety Instructions 3 2. General Instructions 4 3. Recommended Application 5 4. Design 6 5. Assembly 6 6. Operation 7 7. Technical Data 8 7.1 Type: EJG-21 (Standard Version) 8 7.2 Type: EJG-22 (EEx M-Version) 8-2 -

LSP compact Installation & Operation Manual Intra-Automation GmbH 1. SAFETY INSTRUCTIONS This manual contains instructions you have to take under consideration for your own security and, as well, to avoid damages. The instructions are indicated by a danger sign and according to the grade of risk designed as follows: DANGER means that death, personal injury or high damage to property will happen, if there should be taken no precaution. WARNING means that death, personal injury or high damage to property can happen, if there should be taken no precaution. CAUTION with danger sign means, that only small injuries can happen, if there should be taken no precaution. Limited liability CAUTION without danger sign means, that damage to property can happen, if there should be taken no precaution. ATTENTION highlights actions or procedures which, if not performed correctly, may indirectly affect operation or lead to an instrument response which is not planned. NOTE is an important information about the product itself, the handling of the product or that part of the manual to which special attention is to be drawn. We have checked the contents of this manual in accordance with the hardware. But we cannot guarantee that there will be no differences between the manual and the hardware. The manual will be checked frequently to correct the manual in the following versions. Copyright Intra-Automation GmbH 2010 All rights reserved No part of this manual may be reproduced in any way (printed, photo-copied or by any other method) without prior authorization by Intra-Automation GmbH nor may this catalogue be used, distributed or copied in any electronic format. Intra-Automation GmbH 2010 technical changes are subject to change - 3 -

Intra-Automation GmbH Installation & Operation Manual LSP-compact 2. GENERAL INSTRUCTIONS NOTE For reasons of clarity the manual does not contain detailed information about all types of products and cannot take into account every conceivable case of installation, operation or maintenance. If you require further information or should any problems occur which are not sufficiently explained in the manual, you can consult your local Intra- Automation branch to obtain the necessary information. May we also draw your attention to the fact that the contents of the manual are not part of a previous or existing agreement, approval or legal relationship or an amendment thereof. All obligations of the Intra- Automation GmbH result from the contract of purchase which also contains the full and solely valid warranty agreement. These contractual warranty conditions are neither extended nor restricted by the contents of the manual. The contents reflect the technical state at the time of going to print. They are subject to technical modifications in the course of further development WARNING Intrinsically safe devices lose their license as soon as they are operated on circuits which do not meet the requirements of the EC test certificate. The device may be operated with high pressure and corrosive media. Therefore serious injuries and/or considerable damage cannot be ruled out in the event of improper handling of the device. The perfect and safe operation of this equipment is conditional upon proper transport, proper storage, installation and assembly as well as on careful operation and commissioning. The equipment may only be used for the puposes specified in this instruction manual. Exclusion of liability All modifications to the device require the expressed approval of the manufacturer. For damages due to unauthorized modifications Intra-Automation GmbH declines all reliabilities. - 4 -

LSP compact Installation & Operation Manual Intra-Automation GmbH Qualified Personnel are persons familiar with the installation, assembly commissioning and operation of the product and who have the appropriate qualification for their actions, such as: - training or instruction or authorization ot operate and maintain devices/systems accoding to the standard of safety technology for high pressures and corrosive media. - training or instruction according to the standards of safety engineering in the care and use of suitable safety equipment. - training in first aid. CAUTION! Modules which are sensitive to electrostatic charge may be destroyed by voltages which are far below the human level of perception. These voltages occur already when you touch a component or electrical connections of a module without first discharging yourself electrostatically. The damage incurred by a module as a result of an over voltage is not usually immediately perceptible but only becomes noticeable after a long time in operation. 3. Recommended application On the following solid contents (here: dust) in the fluid (here: gaseous medium) the application of an Air Purge Unit is recommended: Solid content in mg/m³ Recommendation < 140 No Air Purge Unit needed 140 280 Air Purge Unit recommended > 280 Air Purge Unit needed In doubt?: Please ask our consultants for a recommendation. - 5 -

Intra-Automation GmbH Installation & Operation Manual LSP-compact 4. Design Air purge unit air purge block Spülblock air purge connection Luftspülanschluß flow 3-way valve differential pressure transmitter Air purge Flow sensor 3-way-manifold Differential pressure Durchflußsensor 3-Wege- Differenzdructransmitter connection transmitter Ventilblock 5. Assembly The air purge block has to be mounted directly to the differential pressure transmitter (s. Fig. 1) by using the provided screws (M10 x 50mm, DIN 912) and seals (material: PTFE). Differential pressure transmitter LSP compact Vent/Drain screws Fig. 1 The p-transmitter has to be screwed to the air purge block using the provided vent/drain screws (¼ - NPT) (s. Fig. 2). On the opposite side of the p-transmitter you have to connect the pressure drop pipes (s. Fig. 1: Direct mounting IBF with flange plate and 3-way-manifold). This will ensure that both flow sensor and transmitter are purged and cleaned correctly. On the lower side of the purge block you will find the connections for purge air (s. fig. 2). Standard is two ¼ - NPT-F threads (other dimensions on request). - 6 -

70 LSP compact Installation & Operation Manual Intra-Automation GmbH Vent/Drain screws ¼ NPT 40 Fig. 2 Purge-air connections ¼ NPT-F (max. 3,5 bar) Please note the necessary power supply for operating note on the nameplate. ATTENTION Before starting the purge unit please ensure that the supply voltage is in accordance with the data on the nameplate. 228 114 58 solenoid valve solenoid valve Fig. 3 6. Operation LSP-Compact can be controlled by the customer using there own switch devices, i.e. mechanical switches, relays or using his SPS. Customer can also use the DigiFlow for controlling the air purge unit. The solenoid valves MV1 and MV2 of the LSP-Compact can be control by using relay #1 or #2 of the DigiFlow. By controlling the solenoid valves the powered scavenging air gets through the p-transmitter into the flow sensor. Control time t s (purging time), t n (settle time) and t a (cycle time) can be configured in the operating program of the DigiFlow 515 easily (see operation manual of DigiFlow -chap. 1.2, page 35). - 7 -

Intra-Automation GmbH Installation & Operation Manual LSP-compact 7. Technical data 7.1 Type: EJG-21 (Standard version) article-no. : EJG-21.. valve type : 2/2 way, direct controlled medium : air function : In rest position closed pipe connection : 1/4" NPT fitting position : random nominal width : 3 mm Kv flow rate : approx 0.23 m³/h operating pressure : max. 6 bar nominal stroke : 1 mm Leakage rate : no bubble tracking temperature of medium : -10... + 90 C ambient temperature : max. 55 C material of valve body : Anodized aluminium or ST ST material of parts inside : ST ST material of seals : FPM nominal voltage : AC: 24 V, 110 V or 220 V / 50 Hz DC: 24 V protection class : without make time : 100% type of protection : IP 65 electrical connection : acc. DIN 43650 power consumption : 21 VA AC (start up) 12 VA/ 8 W (during working) weight : approx. 2.7 kg 7.2 Type: EJG-22 (EEx M - version) article-no. : EJG-22.. valve type : 2/2 way, direct controlled medium : air function : In rest position closed pipe connection : 1/4" NPT fitting position : random nominal width : 2 mm Kv flow rate : approx. 0.23 m³/h operating pressure : max. 5 bar nominal stroke : 1 mm Leakage rate : no bubble tracking temperature of medium : -10... + 100 C for temperature class T6-30... + 60 C (for single mounting) ambient temperature : max. 135 C material of valve body : Anodized aluminium or ST ST material of parts inside : ST ST material of seals : FPM nominal voltage : UC: 230V / 50Hz protection class : EEx M II 2G/D T4 ; EEx EM II 2G/D T4 (PTB 00 ATEX 2129X) make time : 100% type of protection : IP 65 electrical connection : Pressed-in cable (3000 mm) power consumption : 7 Watt weight : Ca. 2.7 kg - 8 -

LSP compact Installation & Operation Manual Intra-Automation GmbH ROOM FOR YOUR NOTES - 9 -

Intra-Automation GmbH Installation & Operation Manual LSP-compact Besides the products covered by this brochure, Intra-Automation GmbH also manufactures other highquality and high precision instruments for industrial measurement tasks. For more information, please contact us (contact details on the backside of this brochure). Flow measurement Itabar -Flow Sensor IntraSonic IS210 Ultrasonic Flow Meter Level measurement ITA-mag. Level Gauge MAGLINK Level Indicator Other Measurement Tasks: DigiFlow Flow and Level Computers IntraCon Digital Controllers IntraDigit Digital Indicators / Meters - 10 -

LSP compact Installation & Operation Manual Intra-Automation GmbH International Headquarters: Sales Office for the BENELUX: Intra-Automation GmbH B.V. Intra-Automation HTP Otto-Hahn-Str. 20 PO Box 10 41515 Grevenbroich 4731 AA Oudenbosch GERMANY THE NETHERLANDS +49 (0) 21 81 / 7 56 65-0 +31 (0)165 32 22 01 +49 (0) 21 81 / 6 44 92 +31 (0)165 32 29 70 info@intra-automation.de info@intra-automation.nl www.intra-automation.com - 11 -