Carbon dioxide absorption in a membrane contactor

Similar documents
CO2 absorption at elevated pressures using a hollow fiber membrane contactor Dindore, V.Y.; Brilman, D.W.F.; Feron, P.H.M.

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Ch. 11 Mass transfer principles

MASS TRANSFER LAB. Make & Model. S. No. Equipment

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Manual for continuous distillation

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Applied Fluid Mechanics

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Winery Trials on Gas Control Using 3M Liqui-Cel. 3M Separation & Purification Sciences Erwin Ona, Senior Applications Engr

Cover Page for Lab Report Group Portion. Pump Performance

EDUCTOR. principle of operation

Gas Absorption Column CAG

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

maintaining storage tank dissolved oxygen levels utilizing gas transfer membranes

Fast. Efficient. Precise control. 3M Liqui-Cel Membrane Contactors. Dissolved gas control solutions for the beverage industry

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Workshop 302-compressor-anti-surge

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

Armfield Distillation Column Operation Guidelines

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

The Discussion of this exercise covers the following points:

Gas Absorption Draft Standard Operating Procedure

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Optimizing Effective Absorption during Wet Natural Gas Dehydration by Tri Ethylene Glycol

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Concentration and diafiltration of viral antigens with SmartFlow TFF

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Flow transients in multiphase pipelines

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

MODEL PREDICTIVE CONTROL OF INTEGRATED UNIT OPERATIONS CONTROL OF A DIVIDED WALL COLUMN

Gerald D. Anderson. Education Technical Specialist

DISTILLATION POINTS TO REMEMBER

The University of Hong Kong Department of Physics Experimental Physics Laboratory

A numerical Euler-Lagrange method for bubble tower CO2 dissolution modeling

Diffusivity in Gases Experiment ver 5.10b

Operating Guidelines for PermSelect Modules Liquid Contacting

Lab #4 Pipe Flow, Minor and Major Losses, and Walking in Osborne Reynolds Shoes CEE 331 Fall 2006

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

PEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review

PREPARING SOLUBILITY DATA FOR USE UPDATING KEY RESOURCES BY THE GAS PROCESSING INDUSTRY:

Series Environmental Chambers

Flow and Mixing in the Liquid between Bubbles

Laboratory Experiments No 1: Measuring the Number Distribution

Generating Calibration Gas Standards

NEULOG OXYGEN LOGGER SENSOR GUIDE

CDI Blood Parameter Monitoring System 500 A New Tool for the Clinical Perfusionist

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

UNIVERSITY OF WATERLOO

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

THE GUIDE TO MEMBRANE NITROGEN GENERATORS

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

Basic Autoclave #1 Ideal Gas Law, Inert Gas

PTRT 2470: Petroleum Data Management 3 - Facilities Test 4 (Spring 2017)

living with the lab control of salinity 2012 David Hall

Drilling Efficiency Utilizing Coriolis Flow Technology

Chapter 10 Gases. Characteristics of Gases. Pressure. The Gas Laws. The Ideal-Gas Equation. Applications of the Ideal-Gas Equation

Name Chemistry Pre-AP

Introductory Lab: Vacuum Methods

Customer Responsibilities

The Gas Laws: Boyle's Law and Charles Law

PHASE EQUILIBRIA: HOW TO CALCULATE OXYGEN SOLUBILITY IN CELL CULTURE MEDIUM

HPFM GEN3 - High Pressure Flow Meter

Operating Instructions

USER MANUAL. For the lab scale MINILOOP

Physical Analysis Model Report

The Study of Bubbly Gas-Water Flow Using

Retention Time Locking: Concepts and Applications. Application

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

HYDRAULICS. H89.8D - Hydraulic Bench

DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS. Nanofiltration

1. Study the performance of a binary distillation column operated in batch mode.

Free Surface Flow Simulation with ACUSIM in the Water Industry

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Modeling Diffusion Rates of a Gas in an Enclosed Space

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Countercurrent Stagewise Operations Equilibrium Stage Number of Actual Stages Definition of The Design Problem...

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

Automatic Isokinetic Sampler. ST5 Evo

Development of High-speed Gas Dissolution Device

Energy and mass transfer in gas-liquid reactors.

Hydronic Systems Balance

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Kyoung-Su Im, Z.-C Zhang, and Grant Cook, Jr. LSTC, Livermore, CA USA. 06/14/2016, Dearborn, MI

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Automatic Isokinetic Sampler. ST5 Evo

CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM

Natural Gas Desulfurization Process By MEA Amine: The preferable Engineering Design Procedure

Diffusivity in Gases Experiment ver 05.10a

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Transcription:

FellesLab Aug-Nov 2018 p. 1 of 5 Carbon dioide absorption in a membrane contactor Mahdi Ahmadi Department of Chemical Engineering, NTNU 13. August 2018 Abstract The objective of this laboratory eperiment is to determine carbon dioide absorption rate as a function of the liquid velocity in a hollow fiber membrane contactor. The eperimentally measured absorption rate is to be compared with an absorption rate predicted by a model. The applicability of the model is then to be critically analyzed. Is the provided model a good model for describing this process? 1 Introduction Liquid/liquid or gas/liquid interphase interactions are traditionally carried out using a column, a tower or a mier. All these designs require that the two phases are in direct contact. This direct contact could lead to unwanted phenomena such as foaming, flooding and formation of emulsions, that will reduce the efficiency of the process (1). An alternative for overcoming these complications are the use of non-dispersive contact using a microporous membrane, which also gives a large interfacial area. This eperiment introduces a membrane contracting process, which is a hybrid of gas absorption and membrane separation process (2) and use it to study the absorption of CO 2 from a gas stream into a liquid solvent. 2 Theoretical background A membrane contactor is a device where the mass transfer occurs between two phases without dispersion of one phase within another. That mass transfer is diffusive transport and by assuming steady-state conditions the molar absorption rate is described by Fick s first law, defined by eq. (1). ( ) µa J A = D A (1) J A is the flu of a component A across a surface, D A the diffusion coefficient of the component, the distance and µ A is the chemical potential. The absorption rate, which is the same as the flu, is then driven by the difference in chemical potential across the interface and will have a continuous profile as shown in fig. 1. µ A Phase α Membrane Phase β Figure 1: Illustration of chemical potential profile across the membrane and the two phases. To simplify the calculation, we split the diffusion into three segments. The first segment is from the gas phase into the membrane surface (Phase α), the second segment is the membrane, and the last segment is from the membrane surface at into the liquid bulk (Phase β). For the two first segments, the mass transport rate is fast (3). We, therefore, simplify by assuming very fast diffusion from the gas phase into the interphase at the boundary between the membrane and the liquid phase. The flu is then limited by the solubility of CO 2 in water. By doing the assumption of fast transport into membrane limited by the solubility, the flu can then be described by eq. (2), which will be used for comparison in this eperiment. ( J A = k L C i A CA b ) (2) Where, k L, represents the average liquid phase mass transfer coefficient, CA i is the interface concentration as given by Henry s law, and the liquid bulk concentration is represented by CA b. The mass transfer mahdi.ahmadi@ntnu.no

p. 2 of 5 ST8: Membrane Contactor FellesLab coefficient can be estimated using the Sherwood number, which describes the ratio between convective and diffusive mass transport, defined by eq. (3). Sh = k Ld D A (3) Sh is the Sherwood number, d is diameter and D A is the diffusion coefficient. The Sherwood number can be estimated using the analogy of Leveque s solution for heat transfer (4). For Gz < 10, Sh = 3.67 (4) For Gz > 20, Sh = 1.62 (Gz) 1 3 (5) For the intermediate range of Graetz numbers the Sherwood number can be estimated using the definition defined by eq. (6). Sh = ( 3.67 3 + 1.62 3 Gz ) 1 3 (6) With Gz representing the Graetz number defined by eq. (7). Gz = v L d 2 D A L (7) Where, v L is the liquid velocity and L is the length of the fiber. By assuming laminar flow of liquid and a fully developed velocity profile through the hollow fiber, the bulk concentration in the liquid at any aial distance, z, is given by (5) as defined in??. C b A = CA i z [ ( 1 ep 4k )] Lz v L d (8) Where v is the liquid velocity and d is the diameter of the pipe. The average bulk concentration in the fiber, to be used in eq. (2), can be obtained from the integration of CA b over the length of the fiber, L, as defined in eq. (9). C b A = 1 L L 0 C b A dz (9) The model defined by eq. (2) is valid only for physical absorption of gas with constant gas-liquid interface conditions. This is not the case in this eperiment. A high partial pressure would impose a high absorption rate, which will reduce the total pressure in the gas phase. This will lead to a significant drop in the partial pressure in the gas phase, and therefore a lower concentration at the gas-liquid interface across the length of the fiber. In this situation, high deviations may occur between the flu predicted by the model and eperimentally measured flu, particularly at high liquid flow rates, when the absorption is higher. 3 Set-up and eeperimental procedure The eperimental set-up is illustrated in fig. 2 with the corresponding symbol eplanations included in table 1. Table 1: Unit descriptions for of the membrane contactor rig in illustrated in fig. 2. Symbol IR Set-up description Description Check valve Controlled valve Humidifier IR-sensor Manually operated 3-way valve Mass flow Measurement of variable Membrane contactor module Pump Reservoir Safety valve The setup is designed for having a miture of CO 2 and N 2 in contact with a solvent, which will be water for this eperiment, using a membrane contactor. This facilitate for absorption of components between the contacting phases. The membrane contactor module used in this eperiment consists of two membrane contactors coupled in parallel, doubling the total capacity. Each of the two membrane contactors contains thousands of small tubes densely packed together with a diameter of each tube in the scale of µm. The result is that the relative surface area is very large compared to total volume. The walls of these tubes are the membrane fiber. The solvent will be in inside the tubes and the gas will be on the outside. Physical parameters on the membrane are available either in data sheets located in the lab or measurable. The letters in the measurements are P for pressure, H for humidity, F for flow, T for temperature. The controllers also have an information bubble, and the C stands for controller. Set-points for the controllers are manipulated via the software. The raw data from the IR-sensor is a number between 0 and 2 16, which you have to calibrate to a number that corresponds to the concentration before you can start the eperiment. More information on the manipulation of the set-points for the controller and the calibration of the IR sensor is given below.

FellesLab Aug-Nov 2018 p. 3 of 5 FC HT P P PC B N 2 IR Gas FC CO 2 P P PC H 2 O Liq Figure 2: This figure illustrates the eperimental setup for the membrane contactor rig. The units are eplained in table 1. Eperimental A summary of the eperimental procedure is given below. i Fill 25 liters of distilled water into the feeding tank and add a small amount of dissolved BTB (Bromothymol blue). ii Add the required amount of NaOH 0.01 M into the feeding tank. iii Give the controllers the selected set-points. More information on the controllers below. iv Calibrate the IR sensor in the region you epect to operate. More information on how to preform the calibration below. v Start the eperiment by pumping the feeding water into the lumen of the hollow fibers. Start with a low pump velocity. Before you start taking measurements, make sure that there is no air in the liquid feeding hose. vi When the concentration of CO 2 stabilizes, determine the liquid flow rate by measuring the time necessary to collect a given volume of liquid. This have be done manually using a measuring cylinder and a stop watch. Record gas temperatures, flow rates of CO 2 and N 2 in the gas inlet, pressures in liquid and gas phases in both inlet and outlet and composition of the outlet gas stream. This is handled by the software. To start the measuring press "Start". Stop the measuring by pressing "Stop Sampling". vii Repeat the two previous point with an increasing liquid flow rate by increasing the pump speed. Collect data for ten different flow rates. As the eperiment progresses, you should be able to observe a color change from blue to yellow. viii After the ten eperiments, re-set the controllers, transfer your data and clean up. Table 2: Controllers in the membrane contactor rig. The setpoints for the flow controllers will be decided by you. The total flow in the gas phase should not eceed 0.5 L/min. Note that the pressure in the gas phase is given in absolute pressure, while the pressure in the liquid phase uses relative pressure. Controller Description Set-point Units CO 2 Flow controller for pure CO 2 in - l min (ST P ) N 2 Flow controller for pure N 2 in - l min (ST P ) p g Pressure controller for the gas outlet 17 psia p l Pressure controller for the liquid outlet 3 psig

p. 4 of 5 ST8: Membrane Contactor FellesLab Setup of controllers There are in total four controllers that require a given set-point. These controllers are listed and specified in table 2. Note that pressure controller for the gas phase operates with absolute pressure, while the pressure controller for the liquid phase uses relative pressure. The set-point for the flow controllers will be decided by you, but the total amount of gas should not eceed 0.5 [ L min]. The flow rates for the flow controllers are set in SLPM 1. Calibration of the IR-sensor The IR-sensor is used to measure content of CO 2 in the retentate. It has to be calibrated before usage. The measurement read an analog signal in the range from 4mA 20mA, which is translated 16-bit number before it is available to us. This means that we get a number between 0 and 2 16 which we have to translate to a percentage. You have to perform a regression in the lab similar to the illustration included in fig. 3. i Bypass the membrane unit by selecting the bypass using the 3-way valve. ii Set the controllers to the setpoints. iii Read the 16-bit number when the number is stable. iv Reduce the amount of CO 2 by setting a lower set-point for that flow controller and take new measurements when stable. Repeat this a couple of times. v Make your regression and put it into the software. vi Set the controllers back to the point before calibration and lead the gas flow into the membrane unit using the 3-way valve. y y = a + b 4 Data treatment You will use eq. (2) as comparison to your eperimental results. The computer is not connected to the Internet, so please bring a USB-stick to transfer the measurements. Make sure that you read the risk a assessment before you do the eperiment. Work plan In addition to the tasks described in the guideline for work plans for the Felleslab, some more specific information for the this eperiment is given here. Read the comments on what to include in the report, so that you prepare to preform the eperiment in such a way that you will be able to answer the questions raised there. Based on what you shall do in the eperiment, the following should be included in the work plan: Some background and theory: Write a short theory summary that includes the equations required for the calculations. This can be included in the final report. How to prepare a 25 liter solution of ph 7.5 from a 0.01 M solution of NaOH. What is purpose of the first humidifier included in the eperiment? How can you determine the absorption rate from the available measurements? Prepare how to do a linear regression for the calibration of the IR-sensor in the lab. Procedure: A description of what you will do in the eperiment and operating procedure. Name the measurements you have to take and the parameters you require to do the calculations. HSE: Name the possible risks. According to your opinion, what is the largest risk with the eperiment? What will you do to avoid or reduce this risk? Figure 3: Eample of a linear calibration curve. The is the bit reading measured, which have to be translated to a percentage, y, using regression. The work plan is to be handed in no later than two working days before lab day. It has to be approved by your supervisor before you can gain access to the lab. As this might mean you need to revise it, you are adviced to deliver at your earliest convenience. 1 Standard Litres Per Minute, 0 C, 14.6959 psia

FellesLab Aug-Nov 2018 p. 5 of 5 Report The report should follow the guideline for report for the Felleslab, some more specific information for this eperiment is given here. Plot the flu of CO 2 as a function of the liquid velocity. Plot both the measured flu and the theoretical flu you have estimated from your model eq. (2). Data for solubility and diffusivity input parameters can be found in (6) and membrane parameters is available in the lab. Compare your results with the model at different flowrates. Comment on the change in composition of the gas phase, throughout the eperiment, and how this affects the results. Also comment on the applicability of the model in this eperiment. You will get alot of data after you have carried out your eperiment. Filter out the measurements you require to do your calculations and any measurements relevant in your discussion and place them in the appendi. You are also required to do sample calculations with numbers and units for one run. It is sufficient to refer to the equation in your theory section and write it out with numbers and units in the appendi. The calibration of the IR-sensor is also to be included in the appendi. Bibliography [1] Alan Gabelman and Sun-Tak Hwang. Hollow fiber membrane contactors. Journal of Membrane Science, 159(1 2):61 106, 1999. [2] Supakorn Atchariyawut, Ratana Jiraratananon, and Rong Wang. Mass transfer study and modeling of gas liquid membrane contacting process by multistage cascade model for CO2 absorption. Separation and Purification Technology, 63(1):15 22, 2008. [3] H. Kreulen, C.A. Smolders, G.F. Versteeg, and W.P.M. van Swaaij. Microporous hollow fibre membrane modules as gas-liquid contactors Part 2. Mass transfer with chemical reaction. Journal of Membrane Science, 78(3):217 238, apr 1993. [4] M.A. Leveque. Transmission de chaleur par convection. Les lois de la transmission, page 204, 1928. [5] V.Y. Dindore, D.W.F. Brilman, and G.F. Versteeg. Hollow fiber membrane contactor as a gas liquid model contactor. Chemical Engineering Science, 60(2):467 479, jan 2005. [6] Geert F Versteeg and Wlm Van Swaalj. Solubility and diffusivity of acid gases (carbon dioide, nitrous oide) in aqueous alkanolamine solutions. Journal of Chemical & Engineering Data, 33(1):29 34, 1988.