Title: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS

Similar documents
20. Technical Equipment. Archived. This section applies to all equipment used in forensic examinations, such as

OPERATING PROCEDURE. Number: V2. Authors. Approvals

Technical Procedure for Instrument Calibration and Maintenance

SKSTEX36(SQA Unit Code-H7C9 04) Calibrate textile production equipment

Miris Ultrasonic Processor

STD-3-V1M4_1.7.1_AND_ /15/2015 page 1 of 6. TNI Standard. EL-V1M4 Sections and September 2015

INTERNATIONAL STANDARD

Standard Operating Procedure Measuring & Testing Equipment

ali-q TM Gravimetric Verification Procedure

This document is a preview generated by EVS

Instrument Installation and Performance Verification

Technical Procedure for General Laboratory Equipment

Mechanical Qualification (MQ) for Apparatus 1 and 2. Oct 10th, 2008

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

TEXAS DEPARTMENT OF PUBLIC SAFETY Breath Alcohol Laboratory

Digital Melting Point Apparatus

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)

PIQCS HACCP Minimum Certification Standards

BSR GPTC Z TR GM References and Reporting Page 1 of 8

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

SOP-I-101 Operation and Calibration of the Analytical Balance

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

ACCREDITATION OF ON-LINE LEAK SEAL ORGANIZATIONS

Requirements for Reduced Supervision of Power Plants, Thermal Liquid Heating Systems, and Heating Plants

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 2: 2018

E2.14 Control of Hazardous Energy. Effective Date: 03/01/2018

1. The Middletown Public Schools will have defibrillators in each school building.

Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)

SFHGEN77 - SQA Code HD48 04 Perform first line calibration on clinical equipment to ensure it is fit for use

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Protective equipment for use in ice hockey. Part 5: Neck laceration protectors for ice hockey players

ASME and PED Requirements for Drum Level Instrumentation. Presented by: Amir Hedayatnia Clark-Reliance Corp.

Secondary Aluminum NESHAP 40 CFR Part 63 Subpart RRR. Example Malfunction Plan for Plant ABC

Changes to the Gas. (Safety and Measurement) Regulations. effective 1 July 2013

This document is a preview generated by EVS

Specialty Gases + World-Class Performance

Significant Change to Dairy Heat Treatment Equipment and Systems

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration

IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS

Purpose. Scope. Process flow OPERATING PROCEDURE 07: HAZARD LOG MANAGEMENT

ISO 6406 INTERNATIONAL STANDARD. Gas cylinders Seamless steel gas cylinders Periodic inspection and testing

UNIVERSITY OF TENNESSEE HEALTH SCIENCE CENTER INSTITUTIONAL REVIEW BOARD CONTINUING REVIEW OF RESEARCH

This document is a preview generated by EVS

Food and Drug Administration Division of Pharmaceutical Analysis. Mechanical Qualification of Dissolution Apparatus 1 and 2

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Pressure Vessel Program

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

ISO Vacuum gauges Calibration by direct comparison with a reference gauge

MET-101 Introduction to Metrology

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration

CTG Certification Protocol -- Version 3.0 SUMMARY

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

PRESSURE SYSTEMS POLICY

Procedure: Pressure equipment safety

Document Control Summary Status: Replacement for Electricity High Voltage SOP v1.0 Version: V1.1 Date: July 2017 Author/Title: Owner/Title:

EN ISO/IEC Technical Requirements

First edition

1811G/H PITOT-STATIC TEST SET

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

This document is a preview generated by EVS

Accreditation for In-Service Inspection of Pressure Systems/Equipment

02 November, 2017 Moderated by Bryan Crist Agilent Technologies

1. Introduction. The Easy Guide to TMV3 Approval

Installation Procedure Esco Miri Multi-Room Incubator

This document is a preview generated by EVS

CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No

New ANSI Fall Protection Standards

Service Calibration are you doing it properly?

Title: Pressure Relieving and Venting Devices Function: Ecology & Safety No.: BC Page: 1 of 7 Reviewed: 6/30/12 Effective: 7/1/12 (Rev.

The University of Georgia Automated External Defibrillator (AED) Program Guidelines

Maximum precision for quantifiable success.

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

This document is a preview generated by EVS

Annex 1 to Decision 2009/007/R

ANNEX 4 ALTERNATIVE TEXT FOR OPERATIONAL GUIDELINES FOR VERIFICATION OF DAMAGE STABILITY REQUIREMENTS FOR TANKERS

Standard Procedure. for using ConfiRM with the SoloVPE. Slope

Regulated Oil and Gas Companies under National Energy Board Jurisdiction

ENGINEERING TECHNICAL REPORT

Calibration Requirements for Direct Reading Confined Space Gas Detectors

ISO 6406 INTERNATIONAL STANDARD. Gas cylinders Seamless steel gas cylinders Periodic inspection and testing

STANDARD OPERATING PROCEDURE FOR MAINTENANCE AND CLEANING OF PULMONARY FUNCTION LABORATORY AND EQUIPMENT

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves

Sr. No. General points CPCB Comments 1. Print option, acknowledgement of submission for CPCB OCEMS Protocol

SOP GEN-007X Crane and Winch Operations

IN-PLACE DENSITY AND MOISTURE CONTENT OF SOIL AND SOIL- AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) FOP FOR AASHTO T 310

Durometer. SHT Series. Instruction Manual SHTD. Valid as of: Please keep the manual for future reference!

Fall Protection. ANSI-What is it, Why is it important? Craig Firl. March 5 th, Company Private

This document is a preview generated by EVS

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

INSPECTION, TESTING AND CERTIFICATION OF GASFITTING WORK DONE UNDER SUPERVISION

Recreational diving services Requirements for the training of recreational scuba divers. Part 1: Level 1 Supervised diver

Transcription:

Page 1 of 7 Sections Included in this Document and Document History 1. Purpose 2. Scope 3. Responsibilities 4. Background 5. References/(Deleted date) 6. Procedure 7. Definitions 8. Records 9. Supporting Documents/(Title of Lab Manual corrected) 10. Document History 1. Purpose 2. Scope 3. Responsibilities This procedure provides guidance for the International Organization for Standardization (ISO) 17025 documentation requirements for laboratory testing equipment in the /Office of Regulatory Affairs (FDA/ORA) laboratories. These procedures apply to equipment maintenance, performance checks, calibration, and verification documentation of the FDA/ORA laboratories. ORA laboratories ensure that laboratory testing equipment is maintained, monitored, calibrated, and verified properly before use. 4. Background ISO/IEC17025 requires laboratory equipment documentation. Although not required, it is often convenient to maintain these documents and records in a logbook. FDA/ORA laboratories may elect to maintain the records otherwise, or use a combination of logbooks and other kinds of document files. It is suggested if some of the records are maintained outside a logbook, the logbook contain a reference to their location. The term logbook is used throughout this procedure. Logbook refers to the documents and records under discussion, regardless of whether they are compiled in a single book. The logbooks include instrument related information such as descriptions of operation, preventive maintenance, repairs, calibrations and verifications. Volume II, Section 2, ORA-LAB.5.5 Equipment provides guidelines on instrument and equipment performance measures and maintenance.

Page 2 of 7 Periodic review of the logbooks, included as part of the laboratory s audit procedure, is essential. 5. References 6. Procedure International Organization for Standardization and International Electrotechnical Commission. International Standard (ISO/IEC) 17025 General requirements for the competence of testing and calibration laboratories (Section 5.5 Equipment). Geneva, Switzerland: ISO Committee on Conformity Assessment. A. Overview 1. The instrument or equipment logbook is compiled, required information maintained in a readily accessible manner. Although the term logbook is used throughout this procedure, each laboratory can establish their own record system to contain all needed information. There is no requirement that the records be kept in a bound notebook or binder. Records may be kept electronically. For electronic records, local work instructions state where these records are located, how they can be accessed, and authorized personnel. 2. The logbooks are kept in a secure, accessible place in the laboratory. 3. The logbooks may contain tabbed sections for ease of use. Not all of the sections found in Part 6., Procedures B. are necessary. At the discretion of the laboratory, the logbook sections may be combined, subdivided, or moved to a different section if it is more convenient. The logbook sections may be arranged in any order and a table of contents may precede them. 4. The records for similar instruments may be kept in the same logbook if they are clearly identified and separated. For example, multiple balances may share a single logbook. 5. The records are maintained for a period determined in each laboratory s record and data management procedure. B. Logbook Sections 1. The following records may be included in the logbook sections, equipment records containing:

Page 3 of 7 description of the instrument, critical accessories and software; manufacturer's name, type identification and serial number; FDA number; installation qualification (IQ) and operational qualification (OQ) records obtained from the installer or manufacturer; and other related material such as instrument service and repair, warranty information, service contract conditions and specifications, and equipment manufacturer representatives names and telephone numbers. 2. Operating Instructions Each instrument or piece of equipment has step-by-step operating instructions, including starting and shutting down the instrument. This may be addressed in manufacturer s manuals or per laboratory procedure. 3. Calibration and Verification a. Each instrument has an established schedule specifying performance checks, including the testing frequency and acceptable performance specifications. These performance checks ensure the instrument is operating properly and consistently prior to analysis. b. Instruments may have peripheral equipment that affect their performance. In these cases, systematic checks are also specified to ensure that the peripheral equipment is functioning properly. For example, tests of voltage regulators ensure voltage stability of automatic samplers for consistent sample delivery. c. The performance check includes a description of the

Page 4 of 7 performance check, the date and analyst name, the determined value compared to a target value or specification, and any information to aid in instrument assessment. Each laboratory may develop forms capturing this information for each instrument. d. For equipment that has scheduled daily or with-use verifications, the records may be maintained on a log sheet kept with the equipment. These log sheets, as well as calibration and verification records, control charts, and other records associated with an instrument may be attached to the logbook when they are complete. e. Quality control procedures monitoring test validity and calibrations connected to a particular sample are generally recorded on the worksheet, and do not need to be retained in the logbook. For example, system suitability test results performed as part of sample analysis are submitted with the worksheet. f. For instrument performance checks where traceability to primary standards is needed, a certificate or documentation establishing traceability or information about the properties or characteristics of the reference material is kept on file. g. When contract calibration or verification services are used, the vendor should provide the following information (if not proprietary): Description of work performed, Test method, Test data, Traceability of standards used, Date vendors test equipment or standards were last certified,

Page 5 of 7 C. Maintenance Performance versus the acceptance criteria, and Certificate of conformance. 1. Service contract or in-house preventive maintenance is documented. This documentation is required for annual maintenance. Maintenance performed at other times, with the exception of routine cleaning, is documented. 2. The documentation includes: D. Repair description of the maintenance; date it was done; and name of the service representative and company, or name of the analyst if maintenance provided internally. 1. Instrument and equipment repairs are documented. 2. The documentation includes: initials of the analyst, and the date the problem was observed, description of the problem; date and initials of the analyst or service representative performing the repair; synopsis of the repair; and cost of repair, copy of the invoice and any additional information (not required). E. Non-Conformances 1. If limits or specifications are exceeded, explanatory documentation is required. Documentation includes the limit of specification that was exceeded, and the probable cause and

Page 6 of 7 resolution. 2. Non-conformances are handled by the laboratory s corrective action procedure, See Volume II, Section 1, ORA-LAB.4.10 Corrective Action Procedure. F. Software Record and Calibration Software calibration certificates provided by the manufacturer are kept on file by the laboratory. G. Manufacturer's Instructions Manuals provided by the equipment manufacturer may be included in the logbook if they are very brief, significant, and readily accessible. 7. Definitions 8. Records None Laboratory equipment records for maintenance, performance checks, calibration and verification Laboratory equipment service and repair records Installation qualification (IQ) and operational qualification (OQ) records obtained from the manufacturer Primary standard certificates Software calibration records 9. Supporting Documents ORA laboratory manual of quality policies and procedures, Volume II, Section 2, ORA-LAB.5.5 Equipment Laboratory record and data management procedure Laboratory corrective action procedure

Page 7 of 7 Document History Version Status Date Location of Name & Title No. (I, R, C) Approved Change History Author Approving Official 1.2 R 11/16/05 In Document LMEB LMEB Approving Official s signature: Date: